Asset-Normalized Distribution Reliability Budget Optimization Using Historical Outage Benefits and Work-Type Learning

Hritik Gopal Shah, Catherine Tajmajer

eess.SY ·submitted 2026-10-22 18:07 UTC · v1

Abstract

Reliability investments compete for constrained capital but are often evaluated in separate programs. This paper presents a data-driven framework that translates historical work orders, geographic asset records, outage events, and costs into comparable customer-minute and customer-interruption benefits at the circuit-zone level. A normalization process maps historical device names and non-isolating assets to current automaticisolating-device zones and links investments to pre- and postconstruction outage histories. Utility data covering more than $250 million in investments completed from 2010 to 2020 are used to estimate benefit factors for seven work types. Those factors feed a mixed-integer portfolio model that selects at most one applicable action per zone under a capital budget. Observed reductions range from 32% to 94% for customer-minutes interrupted and from 43% to 93% for customer interruptions. The framework provides a traceable path from heterogeneous utility records to zone-level reliability investment decisions

Closest papers

Nearest neighbours by meaning across the whole index.

Long-Term Operational Planning Using Scenario-Based System Load Forecasting

cs.CR ·2026-09-28 ·Akash Debnath, Shiuli Subhra Ghosh, Jaime De La Ree, Alex Freeman, Kavin D Jones
similarity 0.54
Abstract

The rapid expansion of hyperscale data centers is significantly increasing electricity demand in Northern Virginia. Dominion Energy, the region's primary electric utility, must reinforce its transmission network to support this growth. These projects require planned outages that must be evaluated months in advance to support construction planning and outage coordination while meeting NERC and PJM N-1 reliability requirements. Long-term outage studies are commonly performed day by day using monthly or seasonal peak-load assumptions. Although this approach simplifies analysis, it can be overly conservative because it does not capture granular load variability. Consequently, short-duration outages that may be feasible under realistic loading conditions are often postponed or denied, delaying critical transmission expansion and grid modernization projects. This paper evaluates the operational value of incorporating realistic multigranular load forecasts into long-term, contingency-based outage assessments and compares the results with conventional peak-based methods. Daily, weekly, and monthly forecasts are developed using statistical and machine-learning models, including SARIMA, Prophet, Gradient Boosting, and Random Forest, followed by bottom-up temporal reconciliation to maintain consistency across forecast horizons. Results show that granular load forecasts reduce unnecessary conservatism and improve outage accommodation, particularly for short-duration requests, without changing existing reliability criteria. The proposed approach can strengthen long-term outage coordination and support timely transmission reinforcement and grid modernization.

0.20

Multi-Appliance Non-Intrusive Load Monitoring via Label-Preserving Aggregate Recomposition and Prediction Consistency

cs.LG ·2026-09-16 ·Jiangfeng Liu, Yanfang Fan
similarity 0.53
Abstract

Non-intrusive load monitoring (NILM) estimates appliance power sequences from aggregate power, but models trained on source households commonly lose accuracy in unseen households. Aggregate power also contains loads from other appliances and measurement error, so predictions may depend on the residual background that co-occurs with source-household targets. Time-aligned submetered measurements and the additive decomposition of aggregate power expose a relation unused by window-wise supervision: an aggregate window can be recomposed by replacing only its residual background while preserving all modeled target-appliance power sequences pointwise. We combine label-preserving aggregate recomposition with prediction consistency. Both windows receive complete power and operating-state supervision. For each appliance, disagreement between the two power predictions is penalized only when both satisfy a fixed reliability criterion and only to the extent that it exceeds a fixed margin. The proposed method is implemented using a multi-appliance architecture with two-stage shared-to-specific mixture-of-experts routing. On REDD, UK-DALE, and REFIT, the proposed method lowers appliance-averaged mean absolute error relative to single-window training from 14.75 to 13.14 W, from 8.88 to 8.51 W, and from 15.83 to 14.55 W. Label-preserving aggregate recomposition and prediction consistency are used only during training, and add no inference-time module or parameter.

0.25

A multi-stage probabilistic framework to estimate gas-fired generator performance during extreme winter weather

cs.LG stat.ML ·2026-10-03 ·Sajjad Uddin Mahmud, Anamika Dubey
similarity 0.53
Abstract

Extreme winter weather has repeatedly disrupted gas-fired power generation in the United States, yet the plant-level data needed to systematically quantify outage risk remain proprietary. Using publicly available weather and electricity demand data together with anonymized generator contingency records from the North American Electric Reliability Corporation (NERC), we develop a three-stage Bayesian probabilistic framework for estimating winter-driven generator performance. Applied to New York State (2013--2022), the framework sequentially estimates: the hourly probability of a generator contingency event, the expected net available capacity conditioned on an event occurring, and the event duration. Colder conditions and higher electricity demand are associated with higher failure probability, lower retained capacity, and longer event duration. Under the most severe observed stress conditions, estimated mean hourly event probability reaches 24\% , while expected mean net available capacity falls to 13\% of nameplate rating. Full outage events have a median duration of 12.7 hours, while partial derating event duration increases from 2.4 to 7.1 hours with capacity loss severity. The proposed framework establishes a transferable baseline that utilities with access to plant-level records can directly extend to obtain more precise reliability estimates for operational planning and resource adequacy assessment.

0.24

ReCo: When to Relocate Sensor Kits under Deployment Constraints -- A NILM Case Study

cs.LG ·2026-09-28 ·Haokun Chen, Yu Tong, Yehai Chen
similarity 0.53
Abstract · 8 pages, 3 figures, 6 tables

Many sensing tasks obtain training labels only by deploying instruments in the field. With a limited number of sensor kits, a collection deadline, and measurement downtime at every move, the collector must repeatedly decide whether to stay at the current site or relocate. We study this decision in non-intrusive load monitoring (NILM), which estimates the power drawn by individual appliances from a home's main meter and is trained on data from homes temporarily fitted with appliance-level sub-meters. In NILM, appliance usage varies with the appliance, season and climate, and the value of new data depends on how diverse the combinations of target operation and background load are. To address this, we propose a constraint-based relocation framework and instantiate it for NILM as ReCo (Relocation by Coverage gain). ReCo counts new operating regimes in a joint target-background feature space, forecasts each home's future gain from the data collected so far, and each night weighs the gain of staying against the gain of moving elsewhere after the downtime. In replayed deployments on the Plegma dataset under two kit counts and two downtime costs, ReCo outperforms fixed-dwell and count-based schedules and a threshold rule using the same metric in every setting. Its advantage is not explained by collecting more days alone and reflects allocating the days to more valuable homes and periods.

0.18

LoaDiff: Conditional Generation of Electricity Consumption Time Series for Energy Analytics

cs.LG cs.AIeess.SP ·2026-09-10 ·Mariia Baranova, Adrien Petralia, Etienne Le Naour, Nathan Etourneau, Guillaume Hofmann +1 more
top venue similarity 0.53
Abstract · 10 pages, 5 figures. This paper appeared in IEEE ICDM 2026

The energy transition is reshaping residential electricity consumption through the increasing adoption of distributed generation, electrified appliances, and demand-response programs. Understanding these evolving behaviors requires access to granular smart-meter data for applications such as load forecasting, appliance detection, and demand-side flexibility analysis. However, such data are subject to strict access restrictions and data-protection regulations. Thus, realistic synthetic alternatives are necessary. In this paper, we introduce LoaDiff, a diffusion-based generative model for year-long, sub-hourly smart-meter load curves. LoaDiff supports flexible conditioning on static household attributes, such as appliance ownership, and dynamic contextual variables, including calendar information and outdoor temperature. We evaluate the model against multiple generative baselines on three residential electricity-consumption datasets. Our experiments assess four complementary dimensions: fidelity and diversity, training-record memorization risk, downstream utility for load forecasting and appliance detection, and conditional controllability under alternative temperature conditions. The results show that LoaDiff generates realistic and diverse load profiles, achieves a favorable trade-off between generation quality and limited evidence of memorization, preserves information useful for downstream energy applications, and responds coherently to changes in conditioning variables.

0.44

State-of-Charge Targets for Storage Participation in Two-Settlement Markets: Reliability, Price, and Compensation Impacts

eess.SY ·2026-11-13 ·Yichen Li, Alexandre Moreira, Ruiwei Jiang, Miguel Heleno, Julie Mulvaney-Kemp
hot direction similarity 0.52
Abstract

As energy storage assumes a larger role in electricity systems, market operation must coordinate its use across time to support reliability during periods of system stress. Minimum state-of-charge (SOC) targets provide a means of preserving energy for these periods, but their design shapes reliability, operating efficiency, and storage compensation. This paper evaluates alternative SOC target designs in a California-based day-ahead and real-time electricity market model. The comparison examines targets based on day-ahead schedules or rolling centralized dispatch, enforced at the individual-resource or system level, across seasons, stress conditions, and participant information settings. The results show that retaining more energy does not necessarily reduce load shedding: targets that restrict discharge can limit storage support during shortages. Under critical summer conditions, individual targets derived from rolling centralized dispatch reduce weekly load shedding by approximately 83--84\% relative to operation without targets. Lower RT clearing costs and average prices can coexist with higher storage compensation, reflecting the role of day-ahead positions and real-time deviations in determining settlement outcomes. These findings highlight the importance of coordinating energy retention with timely discharge and network deliverability when designing SOC requirements for storage participation in electricity markets.

0.25

From Shared Demand Patterns to Local Uncertainty: Probabilistic Load Forecasting by Mixing Compact Adaptations

cs.LG cs.AI ·2026-10-06 ·Haoran Li, Zhe Cheng, Yang Weng
similarity 0.52
Abstract

Probabilistic load forecasting has been widely studied for power-system operation and planning, but customer- and transformer-level forecasting introduces a distinct scalability challenge. At these levels, load uncertainty is strongly affected by customer behavior, weather, and mixed load composition, making it difficult for a single shared model to capture heterogeneous patterns. Using separate probabilistic models can improve local accuracy, but becomes costly to train, store, update, and validate at scale. To address this challenge, we develop a scalable customer-aware forecasting framework that learns common demand behavior through a shared model while adapting only a compact subset of parameters. Rather than using an independent model for each load or assigning each load to a specialized model, the proposed design learns a small bank of low-dimensional adaptation components and allows each load to combine them according to its forecasting characteristics. This preserves shared knowledge across customers while providing sufficient flexibility for heterogeneous and mixed load compositions. Experiments on 590 load profiles from the SMART-DS dataset show consistent improvements in deterministic accuracy and probabilistic quality over statistical, neural-network, Transformer-based, and pretrained time-series baselines, while retaining low storage and inference costs.

0.12

Cost-Informed Learning for Aggregating Building HVAC Flexibility

eess.SY ·2026-09-22 ·Jingguan Liu, Cong Chen, Xiaomeng Ai, Jiakun Fang, Jinsong Wang +1 more
benchmark similarity 0.52
Abstract · 11 pages, 14 figures

This paper develops a cost-informed aggregation framework that learns an aggregate flexibility set of building heating, ventilation, and air-conditioning (HVAC) loads to minimize the aggregator's dispatch cost. Existing aggregation methods mainly use volume-oriented objectives and treat flexibility aggregation and downstream utilization as separate stages. Consequently, the resulting aggregate set may fail to preserve the flexibility most valuable for reducing downstream dispatch costs. To address this limitation, we represent aggregate HVAC flexibility using a parameterized storage-form surrogate and jointly learn the surrogate parameters and the inner-approximation objective from downstream dispatch-cost feedback. This cost-informed feedback allocates the surrogate's limited representation capacity to cost-relevant regions of the aggregate flexibility set. To account for electricity-price uncertainty, we formulate a distributionally robust conditional value-at-risk (DR-CVaR) downstream problem that captures both distributional ambiguity and tail risk. For efficient learning, we reformulate the DR-CVaR problem as a convex second-order cone program. We estimate cost gradients using randomized smoothing and a score-function estimator, avoiding differentiation through large-scale building-level optimization problems. Case studies using NYISO price data show that the proposed framework reduces dispatch costs relative to a volume-oriented aggregation benchmark and that suitable risk and ambiguity settings can lower the out-of-sample CVaR of dispatch costs.

0.22