CS Paper Radar

RAISE-Vision: An Automated Contact Angle Measurement Platform for Contact Lens Wettability Characterization

Erin Ng, Mohammad Nazeri, Julie S Liu, Tithi Choksi, Lyndon Jones, Frank Gu

cs.RO ·submitted 2026-10-23 05:34 UTC · v1
code/dataunusual

Abstract

Contact angle (CA) is a common parameter measured in the development of novel contact lens materials and surface coating technologies. Existing literature on in vitro CA of contact lenses via the sessile drop method is hindered in repeatability, reliability, and comparability due to inter-laboratory and inter-operator protocol variation. In this work, the Robotic Autonomous Imaging Surface Evaluator for vision applications (RAISE-Vision) is introduced as an automated platform for CA measurement on curved hydrogel surfaces, with specific application to in vitro contact lens wettability analysis throughout air exposure. Customized 3D printed hardware, such as lens mounts, camera holders and drying apparatuses, was designed to facilitate an automated repeated sessile drop workflow within a liquid handler. Collected images were directly fed to a custom open-source image processing script for CA determination on a curved surface that combines the elliptical fit and tangent methods to allow for variations in droplet shape. The CA of senofilcon A contact lenses measured using the RAISE-Vision platform increased from $62.6 \pm 5.5^\circ$ to $83.4 \pm 2.1^\circ$ over 10 sequential measurements in air and was able to replicate results obtained using an analogous manual protocol ($p = 0.470$). The custom image processing script was also separately demonstrated to generate comparable results to a commercially available CA determination software ($p = 0.343$). Aside from minimizing operator variability for CA measurement, RAISE-Vision provides a platform for standardized in vitro contact lens wettability analysis and understanding of surface wetting behaviour during air exposure.

Comment
27 pages, 7 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Tactile Reconstruction of Contact Task Frames and Forces for Hybrid Force/Motion Control

cs.RO ·2026-10-07 ·Antonio Rapuano, Simone Orelli, Barbara Bazzana, Antonio Franchi, Alessandro De Luca
similarity 0.52
Abstract · 14 pages, 9 figures, 7 tables. Video: https://youtube.com/playlist?list=PLejKMZmW8AvI. Dataset: https://doi.org/10.5281/zenodo.23209032

Hybrid force/motion control requires knowledge of the interaction force and of a task frame defining the force- and motion-controlled directions. These quantities are usually obtained from force/torque sensing or model-based residuals, often assuming also a nominal environment model. This work addresses the online estimation of the contact force and a possibly time-varying task frame using only soft optical tactile sensing, under the assumption of locally planar contact with a negligible contact moment. The proposed method maps a single image of the deformed elastomer of a soft optical tactile sensor to observable contact variables: indentation depth, two surface-to-sensor tilt angles, and 3D contact force, each with a per-sample uncertainty estimate. The mapping is learned through a self-labeling acquisition procedure, in which a manipulator imposes controlled contacts while an auxiliary Force/Torque sensor is used offline to provide ground-truth labels. The tactile measurement is then fused with robot proprioceptive data in an Extended Kalman Filter, producing a continuously updated estimate of the contact task frame and of the interaction force. Control experiments with a DigiTac sensor mounted on a UR10 manipulator demonstrate closed-loop contact force regulation against a flat rigid board in linear and angular motion by a human operator, with touch as the only exteroceptive feedback.

0.23

TacClip: a clip-on sensor measures dynamic contact forces without covering the fingerpads

cs.RO ·2026-09-08 ·Yuqian Ye, Hao Li, Jingxi Xu, Haojun Feng, Seongheon Hong +1 more
similarity 0.51
Abstract

TacClip is a minimally encumbering wearable device for recording fingertip deformation caused by contact forces and vibrations. It can be combined with vision- or glove-based hand tracking systems that leave the fingertips uncovered and provides a measure of dynamic contact interactions, while leaving the finger pads exposed so that the user retains natural sensitivity to texture, friction, temperature, and fine surface features. The signal is produced by a Fiber Bragg Grating (FBG) embedded on a small plastic clip mounted over the fingernail. Optionally, for use with vision-based tracking, additional FBGs on polyimide strips can complement camera-based pose estimation. In finger pressing tests, TacClip estimates the force magnitude with typical errors below $0.5~\mathrm{N}$ over a $0$--$8~\mathrm{N}$ range. In tests of cloth handling and tape edge finding, we show that it captures the vibrations and dynamic events generated during exploratory sliding. With no electronics, TacClip can also be used submerged in water, while preserving bare finger contact.

0.14

A Durable Vision-Based Tactile Fingertip for Robotic Manipulation

cs.RO ·2026-08-25 ·F. Richard Cottrell, Megha H. Tippur, Edward H. Adelson
similarity 0.50
Abstract · 22 pages, 20 figures

Currently available commercial vision-based tactile sensors provide rich contact information but remain vulnerable to abrasion and repeated concentrated loading, limiting their use in demanding robotic applications. This work presents a durable tactile fingertip comprising a soft silicone gel with a nonpigmented, textured, thin thermoplastic-polyurethane protective film and a replaceable sensing cartridge. Durability was evaluated using two accelerated laboratory procedures: a rotating-drum sanding test and a repetitive probe test applying 39.2 N (4.0 kgf) at 45 cycles per minute. Under the defined sanding conditions, the developed sensor reached the protective-film rupture endpoint after approximately 2-3 hours. During repetitive probe testing, all nine developed sensors remained functionally usable when testing was discontinued: seven after 5 days, one after 6 days, and one after 8 days. Commercial GelSight Mini and DIGIT specimens exhibited initial surface-film rupture after approximately 24-30 seconds of sanding and 25-35 minutes of repetitive loading. Damage to the developed sensor progressed gradually and produced little interference with tactile imaging at the test endpoints. These observations establish durability improvements of more than two orders of magnitude under the defined accelerated conditions. Combining increased durability, gradual degradation, and rapid cartridge replacement offers a practical approach to maintainable vision-based tactile sensing for demanding robotic applications.

0.27

Effect of Twisted-Yarn Architecture on Pressure and Proximity Sensing Characteristics of Textile Capacitive Sensors for Robotic Skin

cs.RO physics.ins-det ·2026-08-14 ·Ishtia Zahir, Eslam Saleh, Maryam Rezayati, Güunter Grabher, Gaffar Hossain
similarity 0.48
Abstract · 10 pages. Submitted to IEEE Transactions on Instrumentation and Measurement

Textile-integrated capacitive sensors offer flexible and conformable tactile sensing for wearable electronics and human-robot interaction; however, the influence of yarn-level architecture on capacitive transduction characteristics remains insufficiently quantified. This work presents a textile capacitive sensing platform based on silver-coated yarns coated with polydimethylsiloxane and assembled into one-, two-, and four-layer twisted configurations. The influence of effective electrode overlap area and inter-fiber separation on the capacitive response is systematically investigated, enabling architecture-dependent tuning of pressure and proximity sensing characteristics. Pressure was calculated using the localized single-fiber contact area, corresponding to stresses of 0.4-3.9 MPa. Increasing the layer number improved mechanical strength and sensing performance: elongation at break increased from 37.5% to 62.5% and 85.0%, while the maximum load increased from 23.3 to 42.7 and 89.7 N. Sensitivity increased with layer number and frequency, reaching 0.1331 MPa$^{-1}$ for the four-layer sensor at 100 kHz. The four-layer configuration also exhibited low hysteresis, minimal thermal drift from 25 to 90 $^\circ$C, and stable operation over 15,000 cycles. Proximity detection ranges of 60, 50, and 40 mm were obtained for the one-, two-, and four-layer sensors, respectively, revealing an architecture-dependent sensitivity-range trade-off. A 4$\times$4 textile sensing array enabled spatial contact mapping, while robotic-arm integration demonstrated real-time touch and proximity detection with an end-to-end robotic system latency (from detection to robot reaction) of 403 ms. The results establish yarn architecture as a tunable design parameter governing the measurement characteristics of textile-integrated capacitive sensing systems.

0.12

A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device

cs.RO cs.HC ·2026-09-08 ·Korab Hoxha, Mirza Imamovic, Angelo Henriques, M. Ali Nasseri
similarity 0.48
Abstract · This work has been submitted to IEEE Access for possible publication

Input devices for robotic microsurgery are frequently described as preserving the surgeon's trained technique, but the claim is rarely measured. We compared manual and teleoperated intraocular instrument motion with the trocar constraint, the instrument, the eye model and the tracking source common to both conditions, so that the control interface was the only factor varied. Prior comparisons cannot hold the instrument fixed, because a robotic instrument is not the tool used manually. Sixteen participants performed a navigation task on a commercial ophthalmic simulator by hand and through a three-degree-of-freedom input device commanding a five-joint robot. Task outcome was equal but at ceiling: every participant acquired all five targets under both interfaces with no retinal or lens injury. Execution differed on every measure. Teleoperated trials took three times as long at a quarter of the median speed, covered less than half the angular working range, and were broken into 3.5 times as many separate movements. Completion time and movement fragmentation improved substantially across four trials of practice and had not plateaued; the measures set by the configured rate ceiling and joint limit changed the least. Finger activity doubled and pinch variability tripled, so reducing instrument degrees of freedom redistributed manual effort rather than reducing it. The interface preserves the outcome and reshapes the execution.

0.30

LUMO: Designing Luminous Contact Morphology for Repeatable Whole-Finger Contact Observation

cs.RO ·2026-09-16 ·Dong Ho Kang, Youngsu Ko, Luis Sentis
similarity 0.48
Abstract

A low-impedance robot finger reports through joint torque how strongly it is loaded, but the same torque can arise from a small force near the fingertip or a large force near the joint. Resolving the force therefore requires knowing where along the finger contact occurred. LUMO makes that location externally observable. Embedded LEDs illuminate a compliant silicone pad, and contact deforms the pad so that light emerging from the finger's side changes in a pattern set by where the load acts. Because the same structure also carries the contact load, we optimize its cross-section, including the pad profile, rigid carrier, and lateral void, for two behaviors at once. Mechanically, the pad conforms under low preload while the carrier increasingly restricts further deformation as load rises. Optically, different contact locations produce separated responses on the finger's side. The search uses rigid--soft contact simulation, ray tracing, and multi-objective Bayesian optimization. Across two silicones, six contact locations, and 10- and 30-mm spherical indenters, the optimized morphologies improve neighboring-location separation relative to variation from re-establishing contact by \(15\)--\(59\%\). Estimating contact location from the optical response using the known LED spacing and combining it with joint torque gives \(1.44~\mathrm{N}\) normal-force MAE over 931 samples. In a two-finger hand, localized side responses appear on several links simultaneously during grasps.

0.26

GlowTact: Simple and Compact Vision-Based Tactile Sensing with High Sensitivity and Spatial Resolution

cs.RO ·2026-09-26 ·Yuxiang Ma, Megha Tippur, Pengfei Ye, Sandra Q. Liu, Haonan Chen +2 more
similarity 0.48
Abstract · Project webiste: https://glowtact.github.io/

Vision-based tactile sensors (VBTS) provide rich contact information for robotic manipulation, but existing designs can be hard to simplify and adapt to the size and constraints of humanoid fingertips. We introduce \textbf{GlowTact}, a pressure-responsive vision-based tactile sensing mechanism that directly visualizes contact pressure. \textbf{GlowTact} requires only single-color, non-directional illumination, and the raw tactile image directly represents the pressure distribution without explicit geometry reconstruction. This simple sensing principle enables compact, customizable tactile sensors while preserving high sensitivity and rich spatial detail. We demonstrate gram-scale contact detection, accurate normal-force estimation, and reconstruction of fine contact geometry, including M1 screw threads. These results establish \textbf{GlowTact} as a practical new sensing technology for compact humanoid fingertips, combining a durable nitrile membrane and simple optical design with sensitive and information-rich tactile perception.

0.29

An Automated Thickness Evaluation Procedure Using an Integrated Structured Light 3D Camera in a Robotic Bioprinting Framework

cs.RO ·2026-09-10 ·Ehsan Zobeidi, Omid Rezayof, Farshid Alambeigi
published similarity 0.47
Abstract · This paper has been accepted for publication at the 2026 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2026)

Bioprinting is emerging as a tissue engineering technique to replace common treatment methods for large scale injuries. While thickness of the BioPrinted Constructs (BPCs) have shown to be of importance in the cell maturation and integration, the literature lacks a robust, automated, and quantitative method for measuring these metrics. In this paper, we propose a fully automated vision-based method for measuring the thickness of the BPCs with complex geometries. Leveraging the point cloud and RGB images of a structured light 3D camera, our proposed method performs an image-based segmentation for delineating the BPCs from the RGB images, accompanied by novel geometry-based thickness measurement algorithms performed on the point cloud scans. These algorithms combine the segmentation mask with the robot's forward kinematics data and a 3D point cloud scan to precisely measure the aforementioned metrics for complex-shaped BPCs. The proposed method was evaluated in simulation and experimental studies. In simulation studies, the algorithms were used to measure the thickness of some virtually created BPCs with known thickness. The comparison between the measured and true thicknesses demonstrates the high accuracy of the proposed method, achieving mean absolute errors between 0.025 mm and 0.057 mm in simulation at a spatial resolution of 0.1 mm x 0.1 mm per pixel. Furthermore, we successfully deployed the algorithms on our robotic bioprinting setup utilizing a structure light 3D camera, where complex patterns were printed and the developed methods utilized to accurately measure the thickness of printed BPCs.

0.58