CS Paper Radar

State Estimation as In-context Tabular Prediction

Ayushi Jolotia, Parikshit Pareek

eess.SY cs.LG ·submitted 2026-10-23 11:04 UTC · v1

Abstract

This letter poses state estimation (SE) as an in-context tabular prediction (ICTP) problem. The key idea is a tabular arrangement in which historical measurement vectors and corresponding state estimates serve as the context, and a new measurement vector forms the query for which we predict a state vector. We propose to use tabular foundation models (TFMs), pretrained on synthetic data, whose weights are never updated, so power system data is needed only as context. With frozen TFM weights we estimate the state of 14-, 30-, 33-, 70-, and 118-bus transmission and distribution networks, and do so where weighted least squares (WLS) fails or degrades, under low observability and with bad data. ICTP errors are 11 to 57$\times$ below the per-bus average of the context at full metering, and 1.3 to 4.0$\times$ below it with only 5% of measurements available. With measurements at six buses biased by 8$σ$, the ICTP angle error rises 1.8 to 5.0$\times$ over its bias-free value against 2.5 to 12.7$\times$ for WLS with bad-data detection. Without retraining, ICTP has lower voltage error than DSS$^2$ on both of its feeders, and lower than a retrained TAPINE on two of three reconfiguration sets.

Comment
3 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Learning by Examples: Power Grid Steady State Analysis with a Tabular Foundation Model

cs.LG ·2026-10-14 ·Olayiwola Arowolo, Oluwadara Adedeji, Peter Palensky, Jochen L. Cremer
similarity 0.64
Abstract · 12 pages, 8 figures, under review

Foundation models have shown strong generalization across scientific domains, but their use in power systems remains largely task-specific. We investigate whether a pretrained tabular foundation model (TFM), TabPFN, can serve as a general-purpose neural solver for power grid steady-state analysis. We evaluate the TFM on three tasks: power flow (PF) prediction, N-k contingency screening (NCS), and voltage stability margin (VSM) prediction. We performed experiments on 118- and 2000-bus systems, comparing the TFM against task-specific neural baselines. Without retraining or fine-tuning, the TFM matches or outperforms the best task-specific model in several settings across the three tasks. For 118-bus PF prediction, a variant of the TFM achieves errors of $1\times 10^{-3}$ pu for voltage magnitudes and $0.30^\circ$ for voltage angles, outperforming all baselines. On unseen N-1 contingency and close-to-infeasible PF cases, the TFM is competitive with the DCPF approximation. For millions of unseen N-2 contingencies, the TFM achieves AUCs of 0.92 and 0.95 for branch and voltage violation screening, respectively. The TFM also attains accurate VSM prediction performance for the 2000-bus system with limited labelled data. The TFM attains strong results across the tested tasks despite pretraining without any power-system-specific dataset and requiring no fine-tuning step. These results offer a glimpse into the potential of pretrained TFMs as a neural solver for a range of power grid analysis tasks.

0.15

Bayesian Distribution System State Estimation with Flow Matching

cs.LG cs.AIeess.SP ·2026-10-29 ·Nan Lin, Peter Palensky, Pedro Vergara Barrios
similarity 0.56
Abstract · 10 pages

Medium-voltage feeders have few real-time measurements, so distribution system state estimation (DSSE) rests on pseudo-measurements of the secondary substations, a prior in Bayesian terms. Weighted least squares keeps the power flow exact but reduces this prior to a mean and variance, while supervised deep learning estimators also learn the power flow and are tied to one measurement set. We propose PoSE (posterior sampling for state estimation), which keeps the Bayesian structure of DSSE and learns only what the distribution system operator does not know, namely the distribution of substation injections, modelled by a neural network trained with flow matching on historical data. The power flow equations, grid topology and measurements enter only at sampling, through a noise-aware Kalman-type correction. The neural network therefore never approximates the power flow, but every posterior sample is a physically consistent operating point, and one trained prior serves any measurement set, noise level and topology. On the IEEE 33-bus feeder, PoSE lowers the probabilistic injection error (CRPS) by 6.7-7.5% against a full-covariance Gaussian prior in all 12 tested settings. It provides reliable uncertainty: the 90% intervals contain the true injection almost exactly as often as exact posterior samples would, whereas those of supervised estimators contain it in only 37-78% of cases. On the 240-bus unbalanced three-phase Iowa feeder, it gives the lowest injection, voltage and branch-current errors of all estimators. A fast variant matches this accuracy at 0.2-0.6s per snapshot and, without retraining, beats Gaussian priors and retrained supervised estimators on seven reconfigured topologies.

0.17

Machine Learning-Based State Estimation for an Actual Transmission System Using Field PMU Data

eess.SY ·2026-09-22 ·Shiva Moshtagh, Nihar Thakkar, Anamitra Pal, Evangelos Farantatos
published similarity 0.56
Abstract · Accepted for presentation at the 60th Hawaii International Conference on System Sciences (HICSS-60), 2027

Time-synchronized state estimation (SE) plays a critical role in ensuring real-time situational awareness in modern power systems. However, achieving full system observability using phasor measurement units (PMUs) is often impractical due to cost and deployment constraints. Moreover, SE operation at PMU timescales imposes stringent requirements on latency, robustness, and reliability that are difficult to satisfy using conventional iterative hybrid SE techniques under incomplete observability by PMUs. This paper evaluates the feasibility of deploying deep neural networks for PMU-timescale, time-synchronized SE in real-world PMU-unobservable transmission systems using actual data from a US power utility. Key contributions include a systematic assessment of estimation accuracy, scalability, and computational performance under realistic operating conditions.

0.34

Dynamic State Estimation from Sparse PMUs via Physics-Informed Graph Neural Operators

cs.LG eess.SY ·2026-11-07 ·Huy Hoang Le, Haoguang Wang, Christian Moya, Marcos Netto, Guang Lin
benchmark similarity 0.55
Abstract · 10 pages, 10 figures, 4 tables

This paper proposes a physics-informed graph neural operator for power system dynamic state estimation. From a sparse, intermittent measurement window at a few generator buses, the operator estimates the rotor-angle and speed trajectories of all machines, unmeasured ones included, in one forward pass. A graph-attention encoder processes the measurements, and the swing equations are imposed as a hard constraint or as a soft one with a learned correction that absorbs model errors. It is trained on simulated measurements, without state labels. With several phasor measurement units, masked training hides one from the input but keeps it in the loss. On four transmission systems, simulations show that the operator is the most accurate estimator that neither optimizes per scenario nor uses state labels, except on the smallest system at large model errors, where tuned Kalman smoothers are better. Networks trained on simulated states are more accurate on the two smallest systems but not on the 118-bus system, where the operator is faster and more accurate than hard-constrained moving-horizon estimation. Under model errors, it matches or outperforms an optimization-based benchmark at a fraction of its cost. The results hold for a detailed machine model with exact parameters seen only through voltage phasors.

0.31

Learning-Based Power Flow Estimation with Sparse PMU Deployment in Power Systems

eess.SY ·2026-10-09 ·Van-Hai Bui, Quang Manh Hoang, Akhtar Hussain, Wencong Su
similarity 0.54
Abstract · 14

Accurate monitoring of power flow is fundamental to the secure and reliable operation of modern power systems. Existing data-driven power flow estimation methods typically assume that synchronized measurements are available at every bus, requiring extensive deployment of phasor measurement units (PMUs). Such dense sensing infrastructures substantially increase installation, communication, and maintenance costs. This paper proposes a learning-based framework that minimizes the number of installed PMUs while maintaining high-accuracy systemwide power flow estimation. Instead of relying on measurements from all buses, the proposed method identifies an informative subset of buses whose synchronized measurements are sufficient to accurately reconstruct branch power flow across the network. To this end, a neural network is developed to learn the nonlinear relationship between PMU measurements and system-wide power flows, and multiple PMU deployment scenarios are evaluated to quantify the trade-off between measurement availability and estimation accuracy. The results enable utilities to identify cost-effective PMU placement strategies that balance deployment cost and prediction performance. Case studies on the IEEE 30-bus test system demonstrate that the proposed framework significantly reduces the number of required PMUs while maintaining accurate power flow estimation.

0.18

Benchmarking a Grid Foundation Model for AC Optimal Power Flow: Feasibility and Warm-Start Results on Synthetic Texas and South Carolina Grids

eess.SY ·2026-11-17 ·Tam Kemabonta, Brighton Ombuki, Vladimir Abdelnour
similarity 0.53
Abstract · 5 pages, 3 figures, 2 tables. Submitted to the 2027 IEEE PES General Meeting

Learning-based surrogates for alternating-current optimal power flow (AC-OPF) are often judged by the gap between their objective value and that of a nonlinear solver, which does not show that a prediction satisfies power balance and network limits. This paper tests whether predictions from the pretrained foundation model GridSFM-Open 1.1.0, recently released by Microsoft, are feasible AC-OPF operating points and whether they are useful initial values for a nonlinear solver. The model was evaluated zero-shot and after fine-tuning on 10, 100, and 1,000 labeled scenarios (FT10, FT100, and FT1000) on 500 scenarios for each of two synthetic grids, ACTIVSg2000 (Texas) and ACTIVSg500 (South Carolina), with Ipopt, MATPOWER MIPS, and pandapower PIPS as solver references. The lowest Texas median cost gap, 0.44\% for FT100, coincided with thermal violations in 24.1\% of cases and a median maximum bus power mismatch of 89 MW and 197 Mvar. Texas zero-shot predictions had a median maximum mismatch of 648 MW and 1,641 Mvar, and every South Carolina case violated a thermal limit for every model variant. Seeding Ipopt with FT1000 predictions gave geometric-mean solve-time speedups of 1.55x on South Carolina and 1.12x on Texas (p = 0.06, not significant at the 5\% level), while zero-shot seeds slowed South Carolina solves (0.26x). A small objective gap therefore did not indicate feasibility: although median zero-shot inference took only 1.32 s on Texas and 0.157 s on South Carolina on a shared host, every prediction still required a nonlinear solver, and fine-tuned predictions gave modest, grid-dependent warm-start speedups while zero-shot predictions slowed convergence on one grid. GridSFM may therefore be useful for initializing a nonlinear solver, but obtaining feasible AC-OPF solutions still required the solver.

0.18

Multi-Appliance Non-Intrusive Load Monitoring via Label-Preserving Aggregate Recomposition and Prediction Consistency

cs.LG ·2026-09-16 ·Jiangfeng Liu, Yanfang Fan
similarity 0.53
Abstract

Non-intrusive load monitoring (NILM) estimates appliance power sequences from aggregate power, but models trained on source households commonly lose accuracy in unseen households. Aggregate power also contains loads from other appliances and measurement error, so predictions may depend on the residual background that co-occurs with source-household targets. Time-aligned submetered measurements and the additive decomposition of aggregate power expose a relation unused by window-wise supervision: an aggregate window can be recomposed by replacing only its residual background while preserving all modeled target-appliance power sequences pointwise. We combine label-preserving aggregate recomposition with prediction consistency. Both windows receive complete power and operating-state supervision. For each appliance, disagreement between the two power predictions is penalized only when both satisfy a fixed reliability criterion and only to the extent that it exceeds a fixed margin. The proposed method is implemented using a multi-appliance architecture with two-stage shared-to-specific mixture-of-experts routing. On REDD, UK-DALE, and REFIT, the proposed method lowers appliance-averaged mean absolute error relative to single-window training from 14.75 to 13.14 W, from 8.88 to 8.51 W, and from 15.83 to 14.55 W. Label-preserving aggregate recomposition and prediction consistency are used only during training, and add no inference-time module or parameter.

0.25

Benchmarking Time Series Foundation Models for Load Forecasting Under Covariate Uncertainty

cs.LG eess.SY ·2026-10-05 ·Tomas Kaljevic, Ivan Arzola, Yu Zhang
publishedbenchmark similarity 0.53
Abstract · 5 pages, 1 figure, 5 tables. Accepted to the 2027 IEEE PES Grid Edge Conference & Expo, Salt Lake City, UT, USA, 19-22 April 2027

Accurate short-term load forecasting (STLF) is essential for the reliable and efficient operation of modern power systems. While time series foundation models (TSFMs) have recently demonstrated remarkable performance across a wide range of forecasting tasks, their effectiveness for STLF under realistic operational conditions remains largely unexplored. In this paper, we present a comprehensive benchmark of four trained-from-scratch (TFS) models and four TSFMs across three real-world load forecasting datasets under operational scenarios that differ in the availability and quality of future covariate information. Our results show that Chronos-2 consistently achieves state-of-the-art performance in both zero-shot and fine-tuned settings when future covariates are available or accurately forecast. However, its performance degrades as covariate forecasts become increasingly noisy, whereas TimesNet exhibits greater robustness under severe covariate uncertainty. These findings demonstrate the effectiveness of covariate-informed TSFMs for STLF while highlighting the critical role of robust covariate modeling in real-world forecasting applications.

0.19