CS Paper Radar

Eye Tracking Signal Quality Evaluation: Meta Quest Pro vs HTC VIVE Pro Eye vs HTC VIVE Focus Vision

Aleksandr Chernysh, Mehedi Hasan Raju, Kamrul Hasan, Md Arif Shahriar, Proloy Karmakar, Isayas B. Adhanom, Oleg Komogortsev

cs.HC ·submitted 2026-10-23 17:17 UTC · v2

Abstract

Gaze research in virtual reality needs eye trackers of known error. Thirty participants completed the same protocol on the Meta Quest Pro (QP), HTC VIVE Pro Eye (PE) and HTC VIVE Focus Vision (FV); to our knowledge, this is the first evaluation of the FV eye tracker. In a random-saccade task, median participant mean error was 1.04° on QP, 1.50° on PE and 2.41° on FV, which remained least accurate after linear recalibration. In a later block with a darker background, PE error rose by 0.70°. FV samples were positively correlated: dispersion was 9.8 times the sample-to-sample root mean square. The device clocks showed losses that mean error hides. QP paused for up to 6.04 s, and FV skipped single samples. During instructed eye closures, QP flagged every sample valid while gaze moved 9.74°. Evaluations should report repeated timestamps, loss composition on the device clock and validity during eye closures.

Comment
14 pages, 6 figures; supplementary material (16 pages) included. Submitted to ETRA 2027. Data: https://hdl.handle.net/10877/25342 ; code: https://hdl.handle.net/10877/25343

Closest papers

Nearest neighbours by meaning across the whole index.

Measurement-Guided Conversion of Laboratory Eye-Tracking Data for VR Authentication

cs.HC ·2026-10-21 ·Md Arif Shahriar, Mehedi Hasan Raju, Oleg V. Komogortsev
similarity 0.65
Abstract · 19 pages, 5 figures, 6 tables

Eye-movement authentication in virtual reality (VR) needs longitudinal training data, yet most such datasets come from lab trackers. We convert lab recordings to a VR headset's signal quality while keeping their eye movement, using only unpaired VR recordings of other people. Measurements show that the headset's added noise dominates above 7.8 Hz and that its quality is consistent within a person. A parametric device model re-creates the headset's sampling, a person-consistent calibration error and spectrally shaped noise, and a frequency-locked diffusion renderer re-textures that high-frequency noise. Converted GazeBase recordings match GazeBaseVR in noise level and accuracy, keep their source's saccade dynamics, and are harder to tell from real VR data than two prior conversions. An authenticator trained only on converted data verifies unseen VR users at a 5.9% equal error rate with 45 s of gaze, close to real VR training (5.8%); with 5 s, a gap remains.

0.31

Low Cost Eye Tracking for Vision Screening

cs.RO ·2026-09-25 ·Maissa Abir Smaili, Yaman Ismaiel, Zafer Iscan
similarity 0.64
Abstract · 5 pages, 7 figures

This engineering study assesses gaze-assisted data acquisition during visual screening with a Gaze Quest implementation via webcam and GC308 near infrared camera with an Orlosky eye tracking pipeline. Ten subjects performed under both acquisition conditions. Accuracy of Tumbling E orientation, reported application logMAR value,and response latency were determined from keyboard responses and hence are behavioral outputs as opposed toeye tracker screening results. Frame-to-frame change in theangle between successive normalized gaze vectors (28.2degrees) served as the GC308 eye tracker derived diagnostic with an effective sampling rate of roughly 8 FPS. No screen target calibration or gaze to screen translation was done on the GC308 eye tracker output data for the current analysis and hence, these data represent acquisition stability and not gaze accuracy in relation to the target. The webcam pipeline relied on 25-point screen calibration. Because the display resolution and pixel pitch could not be retained in the records of the study, the reported application logMAR values cannot be viewed as measures of visual acuity in any way.

0.20

From Laboratory to Road: Evaluating Wearable Gaze Accuracy for Driving

cs.CV ·2026-10-06 ·William Engel, Fabian Flohr
similarity 0.62
Abstract · Peer-reviewed and accepted as an Extended Abstract at the German Conference on Pattern Recognition (GCPR 2026). Presented as a poster at GCP…

Bird's-eye-view (BEV) representations have become a widely used interface between perception and planning in autonomous driving, but they encode what is in a scene, not what is behaviorally relevant to a human driver. Gaze offers a compelling behavioral signal for this gap, yet wearable eye trackers are routinely deployed as if their spatial output were ground truth, despite known sensitivity to head motion, illumination, and calibration drift. We present, to our knowledge, the first unified framework for quantifying wearable gaze accuracy under real driving conditions. Our on-road study contains 41 validated scenes in which one driver fixated a vehicle's license plate. Gaze error is measured as the angular difference between the plate center and the gaze direction estimated by the glasses. Separate indoor studies with the same driver and device systematically analyze how distance, illumination, head motion, target motion, and gaze eccentricity affect both systematic bias and gaze precision. The mean on-road error was 4.58 degrees. Applying an offset estimated from the indoor recordings reduced it to 1.10 degrees and improved all 41 scenes. Because this offset varied between sessions, reliable BEV supervision may require online recalibration and condition-dependent estimates of gaze uncertainty.

0.15

How Well Does Webcam Eye Tracking Work "in the Wild"? A Large-Scale Validation of Chiasm and a Comparison with WebGazer

cs.CV ·2026-11-03 ·Artem V. Belopolsky, Florian Perdreau
code/data similarity 0.61
Abstract · 37 pages, 21 figures, 2 tables

Webcam eye tracking can greatly accelerate data collection in basic and applied research by reaching large, diverse samples of participants online. However, its spatial performance is considered well below that of hardware-based systems, limiting its use. We evaluated the first-generation Chiasm webcam eye tracker in a large online study ($N = 505$) spanning diverse participants, devices, and recording conditions. Chiasm achieved a mean spatial accuracy of 2.39 cm ($\approx 2.28^\circ$ at 60 cm), spatial precision (SD) of 1.05 cm ($\approx 1.00^\circ$ at 60 cm), and sample-to-sample precision (RMS-S2S) of 1.29 cm ($\approx 1.23^\circ$ at 60 cm). For the 91% of participants who met a 3 cm calibration criterion, spatial accuracy was 2.15 cm ($\approx 2.05^\circ$ at 60 cm). After three minutes of a task that encouraged head movement, spatial accuracy declined by 0.59 cm, while the gaze center at each target shifted by a mean distance of only 0.37 cm. On the validation block, the offset was 0.30 cm larger for men than for women. Age, region of residence, face luminance, and Michelson contrast showed no reliable relationship with spatial accuracy. A higher eye aspect ratio, a more open eye, was associated with a smaller offset. Wearing glasses decreased spatial accuracy on every validation block. In a comparison between a random subsample ($N = 101$) and a separate sample tested with the open-source tracker WebGazer ($N = 101$) using an identical protocol, Chiasm showed better spatial accuracy (2.18 vs. 4.51 cm) and spatial precision (SD; 1.01 vs. 1.55 cm). WebGazer showed better sample-to-sample precision (RMS-S2S; 0.79 vs. 1.26 cm), which likely reflects conservative, over-smoothed estimates rather than superior stability. These results suggest that Chiasm is narrowing the gap between webcam and hardware-based eye tracking, making large-scale gaze research "in the wild" a reality.

0.34

A Study on Performance Enhancement of a Webcam-Based Real-Time Eye-Tracking System

cs.CV ·2026-11-16 ·Minuk Jung, Kyeonghun Kim, Sooyeon Yoon
similarity 0.59
Abstract · 9 pages, 5 figures, 5 tables

This study proposes a real-time gaze-tracking system that uses a standard RGB webcam to estimate screen coordinates. The system combines ETH-XGaze-based gaze estimation with nine-point calibration and polynomial ridge regression. To reduce errors caused by changes in head position, it also applies a conditional residual correction derived from head and pose features extracted with RTMPose. Whether this correction is used depends on the reliability of the detected features and the characteristics of the calibration data. In a preliminary experiment, one participant completed trials at 12 screen targets. The resulting mean screen-coordinate error was 204.24 pixels, which was 35.83% lower than that of xgaze-js and 57.69% lower than that of gaze_tracker. The system produced valid gaze estimates for all 12 targets. These preliminary findings demonstrate the feasibility of combining user-specific calibration with conditional pose-based correction for webcam gaze tracking. Because the evaluation involved only one participant, further experiments with more participants and a wider range of postures are required.

0.13

GazeFS: Target-Centered Gaze-Trajectory Forecasting and Stabilization from Gaze-Head History

cs.HC cs.AI ·2026-09-03 ·Yaozheng Xia, Zaiping Zhu, Bo Pang, Minghao Xie, Hui Li +2 more
similarity 0.58
Abstract

Target-centered gaze interaction requires more than suppressing frame-to-frame fluctuations: target acquisition produces task-aligned changes in gaze-head dynamics, while a gaze trace may retain a persistent target-relative residual direction. We formulate gaze correction as online target-centered gaze-trajectory forecasting and stabilization and introduce GazeFS, which maps a variable-length gaze-head history to the next target-center direction and a short-horizon Search/Focus estimate without target information at inference. Across 7,960 acquisition episodes from 30 participants, Search-Focus differences remain stable under quality control, onset exclusion, and duration matching. History windows improve phase decoding over the current endpoint, but explicit task progress remains a strong control. Under the 30-participant, five-fold grouped out-of-fold protocol across three seeds, the reductions relative to raw hold in Focus episode bias, within-episode dispersion, and P90 target error are 0.182 degrees, 0.257 degrees, and 0.400 degrees, with participant-bootstrap 95% confidence intervals excluding zero. Endpoint-free replay from empty history preserves the Focus advantage and yields raw-network phase balanced accuracy/AUPRC of 0.925/0.993; coordinate controls further show that recent history contributes beyond explicit progress metadata. GazeFS therefore improves Focus target centering and empirical residual contraction while leaving temporal smoothness as a separate objective.

0.21

Drift Calibration in Geometric Eye Tracking Systems

cs.CV ·2026-08-30 ·Jiaqi Liu, Zixuan Wang, Yuhong Zhang, Dingkang Liang, Jane Hanqi Li +2 more
benchmarkdataset similarity 0.58
Abstract · 11 pages, 6 figures, 3 tables

Geometric eye trackers can provide the spatial accuracy required for gaze-based interaction and multimodal studies, but their measurements remain sensitive to residual session-specific calibration error. Research on correcting this error is difficult to compare because methods are typically evaluated with different devices, target layouts, and error definitions. We present a calibration-focused dataset containing 163 trials from 12 participants, with separate 18-point fitting and 32-point test grids, and use it to evaluate global, local, and composite correction functions under a common spatial-extrapolation protocol. We further introduce a lightweight neural refiner that combines ranked predictions from complementary calibrators. On this controlled dataset, post-vendor correction reduces the mean angular error from $1.53^\circ$ to $1.03^\circ$ with the strongest classical composite and to $0.96^\circ$ with the refiner. In a closed-loop gaze task, lower residual error is associated with higher performance across four online correction conditions. These results provide a reproducible data-quality benchmark for using gaze as a behavioral signal in interactive modeling.

0.21

How Early Can You Tell? Early Eye Gaze Dynamics and Cybersickness Progression in Virtual Reality

cs.HC ·2026-09-21 ·Nevzat Umut Demirseren, Isayas Berhe Adhanom
similarity 0.57
Abstract · 6 pages, 3 figures

Cybersickness remains one of the primary barriers to prolonged and comfortable virtual reality (VR) use, yet the temporal development of cybersickness remains poorly understood because its onset and progression vary substantially across individuals. Eye tracking provides a continuous and unobtrusive measure of user behavior, making it well suited for investigating how users respond throughout VR exposure. However, existing work has mainly focused on aggregate gaze measures or post-exposure assessments, leaving the relationship between early eye-movement dynamics and discomfort progression underexplored. In this paper, we investigate whether early eye-movement dynamics characterize the subsequent progression of cybersickness. Using trajectories of fixation duration, fixation dispersion, saccade amplitude, saccade velocity, and gaze eccentricity computed over the first one to five minutes of VR exposure, we evaluate their association with subsequent discomfort progression and compare early gaze dynamics between participants with low and high post-exposure cybersickness severity. Our results show that early fixation dispersion is consistently associated with subsequent discomfort progression, whereas no significant differences are observed between cybersickness severity groups. These findings suggest that early fixation dispersion can characterize the progression of discomfort rather than the final cybersickness severity. Overall, this work provides new insight into the temporal relationship between early eye-movement behavior and cybersickness progression, contributing to the understanding of gaze dynamics during immersive experiences.

0.19