CS Paper Radar

Progressive Coupling Method for Diffusion Posterior Sampling in Ptychography

Yihan Qiu, Mingtao Huang, Tianyuan Li, Shudong Li, Yuan Shen

cs.LG ·submitted 2026-10-28 03:02 UTC · v1

Abstract

Ptychography is a computational imaging method that reconstructs a sample from overlapping diffraction measurements. This technique relies on these overlapping measurements to provide the redundancy information needed for robust reconstruction, but dense scanning increases acquisition time and data volume. Reducing scan overlaps can improve measurement efficiency but weakens the physical constraints available for reconstruction. Diffusion models provide strong learned prior information, offering a promising approach to compensate for the loss of measurement redundancy. However, effectively utilizing this prior information under weak measurement constraints remains a challenge. We propose a progressive coupling posterior sampling (PCPS) method, which allows for a broader exploration of the solution space under high uncertainty while maintaining stronger diffusion-guided consistency as the reconstruction becomes more refined. Experiments on real X-ray ptychographic data at various scan overlaps demonstrate that PCPS consistently improves reconstruction accuracy compared to traditional iterative methods and existing diffusion posterior samplers, especially at low overlaps. These results show that diffusion priors can reduce the measurement redundancy required for accurate ptychography reconstruction.

Closest papers

Nearest neighbours by meaning across the whole index.

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

cs.CV cs.AI ·2026-10-02 ·Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
similarity 0.69
Abstract · 21 pages, 7 figures, 2 tables

Solving severely ill-posed imaging inverse problems requires recovering image structures that are unobservable or weakly constrained by the measurements. Diffusion models provide expressive learned priors for inferring such missing information, while posterior sampling incorporates measurement consistency along the reverse process. Standard diffusion posterior samplers, however, rely on instantaneous measurement-aware estimates, without explicitly exploiting information carried by previous posterior corrections. We introduce Consecutive Posterior Fusion Denoising Diffusion Null-Space Models (CPF-DDNM), an inference-time strategy that fuses consecutive measurement-aware estimates to improve the diffusive recovery of unobservable image structures, without requiring retraining or additional denoiser evaluations. We instantiate this principle within DDNM, whose range/null-space decomposition reveals that consecutive fusion preserves the measurement-determined component while acting exclusively on the prior-driven null-space estimate. We thus provide a geometric interpretation of CPF-DDNM and a local error analysis that characterizes the optimal time-dependent fusion coefficient, including the extrapolative regime. Experiments on sparse-view and simulated low-dose computed tomography, as well as medical image super-resolution, show consistent improvements over DDNM and competitive performance against diffusion-based inverse solvers.

0.14

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.66
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

eess.IV cs.LG ·2026-10-05 ·Honglei Brinkmann, Carola-Bibiane Schönlieb, Ander Biguri
similarity 0.65
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time and may mitigate motion artifacts. However, angular undersampling provides insufficient information to determine the image uniquely and stably. Limited-angle CT, arising from restricted angular coverage, produces strongly directional information loss associated with the missing angular range. In both settings, image directions may be strongly observed, weakly constrained, or unobservable, leading to severe ill-posedness and reconstruction ambiguity. Existing diffusion-based approaches incorporate measurement information through likelihood guidance, data-consistency operations, or range-null-space corrections. However, they do not generally use the continuously varying measurement sensitivity of the acquisition to jointly shape both reconstruction updates and stochastic exploration. We propose a geometry-aware diffusion-guided stochastic reconstruction framework for sparse-view and limited-angle CT. Its central component is a regularized noise-weighted pullback metric constructed from the CT forward operator and measurement-noise covariance. This metric continuously adapts both the measurement-aware update and stochastic exploration according to directional measurement sensitivity, suppressing changes along strongly constrained directions while permitting greater exploration along weakly constrained and unobservable directions. We complement this geometry-aware update with a regularized data-consistency correction and approximately null-space-restricted stochastic perturbations, implemented matrix-free using forward and backprojection operations together with conjugate-gradient solves. Experiments on sparse-view, noisy, and limited-angle CT demonstrate competitive reconstruction quality, strong measurement consistency, and spatially resolved empirical uncertainty estimates.

0.22

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.64
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.64
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Diffusion Posterior Sampling with Uncertain Forward Models

cs.CV ·2026-10-21 ·Wentao Shangguan, Vivek K Goyal
similarity 0.64
Abstract

Diffusion posterior samplers reconstruct signals by combining a pretrained diffusion prior with a measurement likelihood specified by a forward model and a noise model. Calibration and reference data can characterize uncertainty in the forward model's parameters, such as blur kernels or detector responses. Fixing these parameters at estimated values leaves their uncertainty out of the likelihood, and parameter errors are thus absorbed into the reconstruction. We introduce an uncertainty-aware likelihood (UAL), a Gaussian approximation to the marginal likelihood obtained by integrating over the uncertain parameters. For each candidate signal, UAL propagates parameter uncertainty into a structured measurement covariance, reducing the quadratic penalty along residual directions that parameter variation can explain. Existing samplers can use UAL in their data updates while retaining their pretrained diffusion priors and sampling schedules. Under a fixed Gaussian nuisance model, we bound likelihood error from linearization and average divergence between the exact marginal and UAL posteriors. We compare samplers with and without UAL across six inverse problems spanning Gaussian and motion deblurring, CT, MRI, ultrasound, and fluorescence microscopy, and find improvements in reconstruction and ensemble prediction. UAL reduces geometric mean MSE by 9% to 20% across samplers in the main Gaussian-deblurring setting and by 51% to 92% in motion deblurring when non-blind samplers use the population-mean kernel. In motion deblurring, DAPS and PnP-DM with UAL also give 6.2 to 6.4 dB higher ensemble-mean PSNR than published BlindDPS and Fast Diffusion EM. On the ablation set, UAL outperforms trace-matched isotropic inflation for PnP-DM in both deblurring tasks; in motion deblurring, it also exceeds the best-tested fixed scalar data weighting by 3.3 dB for PnP-DM and 4.2 dB for DAPS in average PSNR.

0.10

Advanced Brain Tissue Imaging with Data-Consistent Diffusion Priors in Laminographic X-Ray Nanoimaging

cs.CV ·2026-09-09 ·Wenxuan Fang, Abraham L. Levitan, Ana Diaz, Carles Bosch, Adrian Wanner +8 more
similarity 0.64
Abstract

Nanoscale imaging of mammalian brains is critical for connectomics. X-ray laminography enables high-throughput imaging of extended, plate-like biological specimens. However, the tilted acquisition geometry leads to incomplete Fourier-space coverage, giving rise to a missing-cone of information. Conventional reconstruction methods cannot recover unmeasured information within the cone, resulting in artifacts that distort fine brain structures. While resolving these requires modeling 3D structure, direct 3D deep learning approaches are limited by data scarcity and computational cost. Here we introduce LUCID (Laminography with Unified Consistent Diffusion), a framework that combines multi-view diffusion priors with projection-domain data consistency. LUCID integrates complementary 3D structural information while enforcing strict alignment with the laminography forward model. On simulated datasets, LUCID substantially improves spatial fidelity and restores missing Fourier components, outperforming baseline methods. Applied to experimental laminography data, LUCID generalizes robustly despite being trained exclusively on fully sampled tomographic volumes, and effectively recovers unmeasured Fourier information.

0.20

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.63
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14