CS Paper Radar

Maxwell-Consistent 3-D Magnetic Field Camera using Scalar-Potential-Based Reconstruction

Paul Jürß, Marija Boberg, Philip Suskin, Tobias Knopp, Fynn Foerger

eess.SP ·submitted 2026-10-29 18:35 UTC · v1
published

Abstract

Various applications require accurate 3-D characterization of magnetic fields with high spatial and temporal resolution. Building on our previously introduced spherical magnetic field camera employing 86 three-axis Hall sensors arranged on a spherical surface, we present a novel magnetic-field reconstruction approach based on the magnetic scalar potential and its spherical harmonic expansion. Unlike the previous reconstruction method that expands each vector component separately, our scalar-potential-based formulation is inherently consistent with Maxwell's equations for source-free fields by design, yielding curl-free and divergence-free field models. Using a simulated magnetic gradient field generated by two permanent magnets, we demonstrate that the proposed method achieves higher reconstruction accuracy, improved robustness to sensor noise and failure, and substantially reduced non-physical divergence and curl compared to the component-wise baseline. Furthermore, the scalar-potential approach attains superior performance with fewer coefficients, indicating a more efficient use of measurement data allowing higher-degree polynomial representations.

Comment
Accepted at IEEE Sensors 2026

Closest papers

Nearest neighbours by meaning across the whole index.

OmniRay: Camera-Agnostic Monocular 3D Reconstruction with Composite Ray Fields

cs.CV ·2026-10-22 ·Namitha Guruprasad, Abhay Yadav, Cheng Peng, Rama Chellappa, Anand Bhattad
positioncode/data similarity 0.57
Abstract · Project page: https://nam1410.github.io/omniray/

Monocular models recover 3D geometry from a single image in one pass, but most assume a pinhole camera and produce distorted geometry on the wide-angle imagery produced by fisheye and panoramic lenses. Camera-aware models remove this assumption by predicting a per-pixel ray field. However, they represent different camera geometries using a single fixed basis to capture both the overall camera projection and its finer variations. We argue that camera geometry can be viewed as having a hierarchy of complexity for representing rays. We present OmniRay, a feed-forward model whose Ray Module is composed of three components: a monotone radial base that captures radially symmetric structure, a spherical-harmonic residual for smooth deviations from it, and a free-form residual for remaining local variation. These components are composed as successive rotations on the sphere, allowing the representation to accommodate diverse camera geometries. Given a single image, OmniRay predicts a ray direction and an up-to-scale radial distance for every pixel, from which a 3D point cloud is recovered without needing camera information at inference time. Extensive experiments across different camera configurations demonstrate that OmniRay establishes a new state-of-the-art in camera-agnostic monocular 3D reconstruction.

0.20

Sparse Light Field Sampling Improves Casual 3D and 4D Reconstruction

eess.IV cs.CV ·2026-08-20 ·Shamus Li, Ruiming Cao, Laura Waller, Kristina Monakhova, Sara Fridovich-Keil
datasetcode/datahot direction similarity 0.54
Abstract · Project page: https://shamus.li/lightfield-gaussian-splatting

Many consumer smartphones, stereo cameras, and light field cameras record multiple synchronized viewpoints in a single exposure event. However, novel view synthesis pipelines commonly use only a monocular stream and rely on camera motion or learned priors to obtain angular coverage. In this paper, we ask: why do we use only one viewpoint? We analyze sensor-limited multi-view, where one sensor trades off spatial and angular resolution, and exposure-limited multi-view, where multiple sensors on one commodity device observe each event simultaneously. We introduce a new dataset incorporating three types of commodity multi-view cameras, and evaluate sparse-view 3DGS and 4DGS baselines measuring reconstruction quality as a function of number of exposures and angle between extreme views. Our results demonstrate that using multiple cameras, even with a low baseline, significantly improves reconstruction quality in single-shot, few-shot, and casual video settings. In addition, under a fixed sensor budget, angular sampling improves reconstruction when exposures are scarce despite lower spatial resolution. The gains are most pronounced for single-shot and dynamic scenes, where a stationary monocular camera lacks the angular diversity to recover scene geometry and motion.

0.36

An Eternal Irradiance Camera

cs.CV ·2026-09-19 ·Jeremy Klotz, Shree K. Nayar
publishedunusual similarity 0.52
Abstract · 18 pages, 18 figures. SIGGRAPH Asia '26

A conventional camera uses millions of pixels to measure radiance from all directions within its field of view. We present an omnidirectional irradiance camera that measures the irradiance function---the illumination incident upon every point on a sphere. The irradiance function varies smoothly over the sphere and hence is bandlimited. We have analyzed this function in the frequency domain and have shown that it is well approximated by a weighted sum of the first seven degrees of spherical harmonics. As a result, the irradiance function can be accurately reconstructed from a small number of samples. This implies that an irradiance camera does not need millions of detectors (pixels)---just a handful of measurements suffice. This brings two major benefits. First, the camera consumes such little energy that it can be completely powered by the light falling on its detectors. Second, it does not capture the visual details needed to identify an individual, and hence privacy is preserved. We have built a prototype irradiance camera, called FluxCam, using 49 detectors arranged on the surface of a sphere. In a well-lit indoor environment, FluxCam can read out and wirelessly transmit its measurements at 30 frames per second using energy harvested from the light falling on it (i.e., without a battery, cable, or external power supply). We show how FluxCam can be used as an optical gyroscope for computing rotation, to monitor a workspace, as an untethered light probe for diffuse relighting, and as an omnidirectional pyranometer for estimating sky conditions and determining the best orientation of a solar panel.

0.42

Any3R: Feedforward 3D Reconstruction from Any Camera Type

cs.CV ·2026-10-26 ·Jingong Chen, Qingwen Zhang, Youming Deng, Chulwoo Pack, Olaf Wysocki +3 more
benchmarkcode/data similarity 0.51
Abstract

Geometry foundation models recover camera poses and dense geometry from a set of images with a feed-forward network, but they expect pinhole images. That assumption is inside the backbone too: the positional encoding and the training loss both bind an image position to a direction in space, and both depend on the lens. We condition both on the dense ray field, the unit direction through every pixel, which describes any central camera without a lens type, distortion coefficients or a bound on field of view. Angular coordinates give the rotary encoding the measured ray angle of each patch, evaluated per view, and solid-angle weighting scales the point loss by the area each pixel covers on the sphere, so neither the encoding nor the supervision depends on the lens. Any3R is therefore a feed-forward model that takes any central camera, and is robust to mixing many camera types per scene, with no retraining per lens. On a benchmark of thirteen central cameras across three datasets, where every method reconstructs with its own predicted camera poses, it is the most consistently accurate method. Any3R enables scalable 3D reconstruction from heterogeneous crowdsourced and archival imagery collections sourced across diverse camera types. Project page: https://jingong-chen.github.io/Any3R/

0.46

Degrees of Freedom Sampling

eess.SP ·2026-09-23 ·Jiawang Li, Mats Gustafsson
similarity 0.50
Abstract

A geometry-based framework for sampling electromagnetic fields over surfaces is presented. The approach extends the shadow-area formulation of electromagnetic degrees of freedom (DoF) from a global mode count to a spatially resolved DoF density that determines the sampling distribution. The observation surface is partitioned into cells containing approximately one DoF, with the cell area determined by the DoF density and the cell shape determined by the projection of the DoF density vector onto the observation surface. In the far field, the source shadow area defines a directional DoF density over the observation sphere, while in the near field, the mutual-shadow density and a DoF density direction determine the local sampling geometry. The resulting method requires only the source-observation geometry and does not require an explicit singular-value decomposition of the propagation operator. Numerical results for several source and observation geometries demonstrate reconstruction performance close to that of operator-based sampling methods. A beamforming interpretation further shows that the sampling cells correspond to geometry-dependent beam regions, establishing a unified connection between DoF, sampling, and beamforming.

0.22

Martine: Benchmarking Multi-View 3D Surface Reconstruction Across Viewpoint Coverage, Resolution, and Lighting

cs.CV ·2026-11-08 ·Robin Bruneau, Baptiste Brument, Frederic Giraud, Bastian Sigrist, Sascha Jecklin +3 more
top venuebenchmarkcode/data similarity 0.50
Abstract · Accepted at the 40th Conference on Neural Information Processing Systems (NeurIPS 2026), Track on Evaluations and Datasets. 23 pages, 14 fig…

Controlled acquisition setups are widely used for high-accuracy multi-view 3D surface reconstruction, as they allow sensor configuration, image resolution, viewpoint distribution, and illumination to be specified. Yet benchmarking remains difficult, since reconstruction accuracy depends jointly on the reconstruction paradigm, object properties, and acquisition regime. Existing benchmarks often restrict viewpoint coverage, resolution, or illumination, which can bias comparisons towards methods suited to the chosen setting. Others lack accurate 3D ground truth or quantified image-to-geometry alignment, limiting their use for metric surface evaluation. We introduce Martine, a benchmark for controlled 3D object surface reconstruction. Martine comprises 28 objects, including transparent materials and fine structures, captured at 9568 x 6376 pixels from 84 views over a spherical cap under both single-light and multi-light regimes. It provides object-independent camera calibration, accurate 3D ground-truth scans, calibration and image-to-geometry accuracy quantified on test images, and 3D property masks for analysing errors by material properties, visibility, curvature and fine structures. Experiments across photogrammetry, classical multi-view stereo, neural implicit surfaces, Gaussian-splatting-based reconstruction, and multi-view photometric stereo show that Martine enables regime-aware evaluation with explicit control over reference-data accuracy. The benchmark resolves sub-millimetric reconstruction differences, with a best observed Chamfer distance of 0.058 mm over the evaluated visible surface.

0.55

FESTiVE: Self-calibrated Spatial-temporal Gradient Characterization for Non-cartesian Imaging on High Performance Systems

eess.SP ·2026-10-30 ·Zachary Shah, Daniel R. Abraham, Nan Wang, Xiaozhi Cao, Qiang Liu +9 more
similarity 0.50
Abstract

Gradient imperfections disrupt the encoding benefits of long-readout imaging applications on high-performance systems. Currently, external field monitoring hardware provides the only reliable solution for general spatial-temporal gradient characterization. We present FESTiVE, a data-driven alternative to higher-order field monitoring. FESTiVE leverages parallel imaging to both implicitly model and explicitly recover field imperfections. Using a fast k-t mapping calibration scan, FESTiVE formulates a time-varying GRAPPA problem which maps k-space data corrupted by a time-varying gradient imperfection against a clean reference. This mapping is represented compactly with an implicit neural representation, from which the spatial-temporal fields are recovered in image space using coil sensitivities. In phantom, FESTiVE produces comparable field measurements to a Skope field camera across multiple non-cartesian 2D acquisition strategies and gradient specifications. In vivo, FESTiVE achieves state-of-the-art image quality for a high-performance diffusion spiral protocol on the head-only MAGNUS 3T, where higher-order phase imperfections are significant. At 7T, on the head-only Siemens TerraX system, FESTiVE enables 300μm spiral imaging where conventional field camera-based approaches fall below probe dephasing limits. In conclusion, FESTiVE enables robust high-resolution non-cartesian imaging on high-performance gradients, characterizing gradient imperfections using parallel imaging rather than field monitoring hardware.

0.28

Automated Fetal Magnetocardiography Reconstruction Using a Biophysical Forward Model

eess.SP ·2026-10-23 ·Jonas Emrich, Karin Narushima, Lena Wunderl, Philipp Wunderl, Tobias Jensch +5 more
top venuecode/data similarity 0.49
Abstract · 29 pages, 16 figures. Includes supplementary material. Published in IEEE Transactions on Biomedical Engineering. Code: https://github.com/ML…

Objective: Fetal magnetocardiography (fMCG) enables early detection of cardiac disease by non-invasively measuring fetal electrophysiological activity. However, current signal estimation methods for fMCG require complex, labor-intensive human processing because they rely on blind source separation or template-based projection techniques. Methods: We propose an automated signal reconstruction approach that recovers fetal and maternal cardiac activity from fMCG measurements without manual annotation. Our approach leverages the relationship between measurements and cardiac signals via a biophysically grounded forward model that represents cardiac sources as time-varying magnetic dipoles. This enables reconstruction of physiologically interpretable three-dimensional vectorcardiographic signals along with their spatial position. Results: Validation on synthetic data with known ground truth confirms accurate recovery of cardiac source parameters. On real fMCG recordings, the reconstruction shows strong agreement with established reference methods. Conclusion: The proposed forward-model approach automatically reconstructs fetal and maternal cardiac activity from fMCG recordings and produces signals in an interpretable vectorcardiographic source domain. Significance: Automated, interpretable fMCG reconstruction could make fetal cardiac assessment more reliable and support potential translation into prenatal care.

0.50