CS Paper Radar

Precision Through Play: Enhancing Fundamental Laparoscopic Skill Acquisition Via Gamified XR and Pseudo-Haptics

Bita koohestani, Ashkan Rezaei, Azam Bastanfard

cs.HC cs.GR ·submitted 2026-10-31 19:55 UTC · v1

Abstract

Extended Reality (XR) technologies have shown potential to improve laparoscopic skills acquisition. Among fundamental skills in laparoscopic surgery is accurate instrument handling. Appropriate instrument alignment and a perpendicular path ensure movement efficiency and improved performance. This work introduces an interactive XR platform designed to support an immersive, engaging, and accessible environment that facilitates continuous practice. This platform incorporates a gamification layer enriched by pseudo-haptics that generate a motivational feedback loop, allowing trainees to continuously practice instrument manipulation and angle control. The platform monitors instrument orientation, computes angular deviation from an ideal reference vector, and assigns scores based on user performance. A point-based scoring component reinforces correct technique and penalizes deviations in tool alignment beyond predefined thresholds. Furthermore, a pseudo-haptic feedback mechanism is integrated to provide real-time tactile feedback when deviation exceeds tolerance. Combined with low-cost hardware and accessible deployment, the framework aims to increase training scalability, engagement, and improve skill acquisition. Preliminary evaluations indicate that integrating gamified feedback significantly improves precision, reduces angular variance, and encourages sustained practice.

Closest papers

Nearest neighbours by meaning across the whole index.

Recording Hand-Held Laparoscopic Instrument Motion in the Operating Room: Magnetometer-Free Fusion of Inertial, Range and Visual Sensing

cs.RO ·2026-09-22 ·Jiyul Lee, Dongho Yee, Juahn Oh, Jinseok Lee, Yechan Seo +7 more
hot direction similarity 0.62
Abstract · Submitted to IEEE ICRA 2027

Most minimally invasive procedures are still performed with hand-held laparoscopic instruments, yet only the endoscopic video is retained; the instrument motion that expresses surgical skill, and that could support skill assessment and robot learning, is lost. Pose from video alone remains millimeters to centimeters off, and an instrument-mounted inertial measurement unit (IMU) cannot rely on its magnetometer, whose field changed with tool pose and between sessions in our measurements. We present a surgical instrument-state logger that clips onto a conventional instrument without modifying the part that enters the patient and fuses a six-axis IMU and a time-of-flight (ToF) rangefinder with a markerless camera in an error-state Kalman filter under the remote center of motion (RCM) of the trocar. Heading comes from the shaft silhouette, segmented by a U-Net, in place of the magnetometer: the rotation-angle error is 0.200°, against 3.58° from the accelerometer and magnetometer alone. Against a Franka Research 3 manipulator, and without alignment to it, the displacement error over 300 translation trials was 1.21mm RMS and the relative-rotation error over 180 rotation trials 0.34° RMS. On continuous trajectories, tracked and displayed in real time, the absolute tip error was 1.22mm (programmed) and 3.04mm (teleoperated) after post-hoc tuning of three filter parameters, and the full fusion beat every sensor subset. Because the estimator uses no magnetic measurement, its accuracy does not rely on an undisturbed field. The same clip-on device could thus record metric tip trajectories during routine hand-held laparoscopy, while displaying the insertion depth and attitude that are hidden once the instrument is inside the patient.

0.38

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

cs.RO ·2026-09-27 ·Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh +7 more
similarity 0.61
Abstract · Submitted to IEEE ICRA 2027

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

0.32

Comparing Haptic Feedback Across Hand Tracking and Controllers in VR Object Interaction Tasks

cs.HC ·2026-09-18 ·Natalia Ocampo, J. Felipe Gonzalez, Robert J. Teather, Kiyoshi Kiyokawa
published similarity 0.61
Abstract

Hand tracking offers natural VR interaction but lacks controllers' inherent tactile feedback, while haptic feedback across input methods remains understudied. We conducted a participant study comparing vibration, impulse, and no feedback in hand- and controller-based VR interaction across grasp-, pinch-, and tap-like gestures assessing performance, workload, and preference. A custom glove and controller-mounted device provided both feedback types, aiming for consistency across input modalities. Controllers were faster for grasp and pinch, whereas hand tracking was more accurate for pinch and preferred overall. Haptics had limited performance effects, although impulse reduced grasp accuracy with controllers. Participants preferred vibration and impulse over no haptic feedback, favouring vibration overall. Our findings reveal a more nuanced relationship between haptic feedback, input device, and interaction context than suggested by previous work.

0.36

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

cs.RO ·2026-09-22 ·Chang Liu, Chenhao Yu, Honghao Zhao, Hao Ding, Haochen Wei +3 more
published similarity 0.60
Abstract · 8 pages, 8 figures. Accepted to IROS 2026

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.

0.41

An Integrated Video-AI Platform for Action-Level Microanastomosis Training and Performance Feedback

cs.CV ·2026-09-06 ·Yan Meng, Daniel A. Donoho
similarity 0.60
Abstract

Developing microanastomosis skill requires repeated practice with timely, action-specific feedback, yet expert review of lengthy microscope videos does not scale to frequent or distributed training. We present an integrated video-AI platform that turns a complete simulated procedure into inspectable, interactive feedback through three connected modules. First, a proposed transformer segments the video into six surgical actions. Second, object detection and tracking localize instrument tips within each action; the resulting kinematic features and action statistics drive supervised classification of five NOMAT-aligned performance dimensions. Third, a grounded large language model (LLM) uses these structured outputs to answer user questions about the current scene, actions, motion, and predicted performance through a unified interface. In a two-site study, 17 participants completed 72 procedures comprising 576 suture placements. The action-segmentation module achieved 87.66\% accuracy and 82.86\% F1, increasing to 93.62\% and 88.32\% after workflow-aware refinement. The five performance classifiers achieved 76.0\% mean accuracy, with Cohen's $κ$ from 0.63 to 0.93. Although the language interface and educational benefit require prospective evaluation, these results establish the technical basis for an expert-supervised platform that can shorten review, expose the evidence behind performance estimates, and support scalable formative microsurgical training.

0.15

From Instrument-Mounted Demonstrations to In-Vivo Execution: Learning Bimanual Laparoscopic Appendectomy Without Robot-Collected Demonstrations

cs.RO ·2026-09-22 ·Dongho Yee, Juahn Oh, Jinseok Lee, Jiyul Lee, Yechan Seo +8 more
code/data similarity 0.60
Abstract · Submitted to IEEE ICRA 2027. Project page & Dataset: https://rosota-research.github.io/instrument-mounted-demonstrations-in-vivo/

Most minimally invasive surgery is still performed with hand-held laparoscopic instruments, and the surgeon's instrument kinematics are lost when the operation ends; only the endoscope video is kept. This paper presents an end-to-end pipeline that captures this motion in the operating room and uses it to train a surgical robot policy, validated on live animals. We introduce a surgical instrument-state logger that mounts on the shaft of a standard laparoscopic instrument and recovers its pose and jaw state from an inertial sensor, a time-of-flight sensor and a Hall sensor, with no external camera or tracker. A data pipeline measures the latency of every sensor channel against a robot ground truth and aligns the channels before forming observation-action pairs. On these demonstrations we train a diffusion policy with a fine-tuned DINOv3 backbone, selecting its design by closed-loop rollouts in a physics simulator reconstructed from depth maps of an ex-vivo rabbit appendix. The policy is then retrained on 849 in-vivo demonstrations from four live rabbits and deployed on four additional live rabbits with electrosurgery armed. With the surgeon selecting the surgical phase, the policy completed the appendectomy in three of the four animals. The results show that demonstrations recorded from a surgeon's own instruments are sufficient to train, select and deploy a bimanual surgical policy in vivo. The robot serves only as the timing reference for sensor calibration and as the executor, and collects no demonstrations. Both demonstration corpora are released to support future surgical robot learning research.

0.34

An Open-Source da Vinci X/Xi Instrument Module for Laparoscopic Surgery Research

cs.RO ·2026-11-16 ·Douglas McDonough, Justin Liao, Jiawei Ge, Antony Goldenberg, Yvonne Zhang +4 more
code/data similarity 0.59
Abstract · Submitted to the 2027 International Symposium on Medical Robotics (ISMR). † Equal contribution. ‡ Equal supervision

Studying electrosurgical tasks on a research robot requires control of both instrument motion and energy activation, along with a record of when each action occurs. This paper presents an open-source module for da Vinci X/Xi instruments on a UR5/UR5e robotic arm. Five motors transmit torque through timing belts to spring-loaded drive discs. An electrosurgical interposer accepts software commands, gives the surgeon's foot pedals priority, and records the source of each activation request. In bench testing, the interposer recorded all 12 activation and deactivation events from six pedal presses. Ex vivo demonstrations included monopolar and bipolar coagulation of splenic tissue and monopolar cutting during gallbladder dissection. Optical tracking of the Fenestrated Bipolar Forceps showed that calibration brought pitch and yaw gains from 0.904 and 1.14 to 1.00 and 1.02, respectively. The module enables researchers to record instrument motion, video, and the timing and source of electrosurgical commands during laparoscopic tasks.

0.32

Scene Graph-Driven Haptic Feedback for Safety Enhancement in Robotic Ophthalmic Surgery via Physically Simulated iOCT

cs.RO cs.CV ·2026-09-07 ·Danial Arbabi, Korab Hoxha, Angelo Henriques, Mirza Imamovic, M. Ali Nasseri
published similarity 0.59
Abstract · 7 pages, 9 figures, 2 tables. Accepted at the 2026 IEEE RAS/EMBS 11th International Conference on Biomedical Robotics and Biomechatronicsnic…

Robotic ophthalmic surgery offers high precision but introduces a "sensory gap" by decoupling the surgeon from their instrument, resulting in a loss of tactile feedback. This paper presents a novel haptic feedback system for subretinal injection tasks leveraging Scene Graphs (SG). The system bridges the sensory gap by analyzing a physically simulated intraoperative Optical Coherence Tomography (iOCT) feed to construct a real-time surgical SG. The SG serves as a semantic abstraction layer for the surgical scene, which is then utilized by a deterministic, rule-based engine to generate state-dependent haptic feedback on a robotic input device. The system was evaluated in a user study (N=16) using an anthropomorphic head phantom and a custom-built surgical robot. Results demonstrate that the SG-driven haptic feedback improved surgical precision, reducing needle alignment error by 14% (p = 0.044) and improving System Usability Scale (SUS) scores by 8% (p = 0.015), while maintaining comparable task completion times. A needle trajectory analysis revealed the emergence of a safer "Align-then-Approach" strategy, in which our haptic negative reinforcement prompted users to fine-tune the tool's trajectory before approaching the retinal target. This work suggests that SGs can effectively serve as the direct computational foundation for real-time, safety-enhancing context-aware haptic feedback in robotic microsurgery.

0.40