CS Paper Radar

Evaluating the Impact of Nonlinear Registration on Longitudinal PET Analysis in a Rodent Stroke Model

Haytham Ziani, El Mostafa Kalmoun, Zohaib Atif, Hyuk-Sang Kwon

eess.IV cs.CV ·submitted 2026-11-02 21:41 UTC · v1
top venue

Abstract

Longitudinal rodent positron emission tomography (PET) studies of stroke and neuromodulation rely on accurate registration to a common atlas space to detect group-level effects. Prior work applying ultra-high frequency low-intensity magnetic stimulation (UHF-LiMS) to a rat model of chronic capsule infarct used affine normalization to a Sprague Dawley MRI template without evaluating that choice. We compare a two-stage (affine and nonlinear) pipeline against an affine- only one for rat PET-to-atlas alignment on the same dataset. Across 32 longitudinal [18F]-FDG PET scans (8 rats, 4 timepoints), the nonlinear stage gave a higher Dice similarity coefficient on every scan, and the gain was significant at the rat level. Jacobian determinants showed no folding on the sampling grid. Group-level linear mixed-effects maps of change from baseline (AFNI 3dLME), computed identically under both pipelines, differ in the size, number and location of their suprathreshold clusters. In this dataset, the registration pipeline is therefore a variable that can change the interpretation of downstream group-level analyses.

Comment
Accepted for presentation at the 2nd International Conference on Artificial Intelligence, Security and Networking (CAISN 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

PET Quantification-Preserving Registration for Longitudinal Whole-Body PSMA PET/CT

cs.CV ·2026-10-15 ·Fryderyk Kögl, Anna Reithmeir, Daniel M. Lang, Emily Chan, Rickmer Braren +1 more
code/datahot direction similarity 0.59
Abstract

We adapt the diffeomorphic coarse-to-fine LapIRN architecture for longitudinal whole-body PSMA PET/CT registration in the Learn2Reg 2026 PSMAReg challenge. The method combines affine pre-registration, multi-modal deformable registration, and test-time instance optimization. We further introduce PET biomarker preservation losses for metabolic tumor volume (MTV) and total lesion glycolysis (TLG), including Jacobian-based constraints, and a per-structure rigidity regularization for skeletal structures. The submitted configuration achieved 81.0% DSC and 6.17 mm HD95, with MTV and TLG errors of 3.3% and 3.3%, respectively, on our evaluation protocol. Code is available at https://github.com/koegl/psmareg.

0.37

Automated carotid artery atherosclerotic inflammation segmentation in PET using MSR-Net

cs.CV physics.med-ph ·2026-10-11 ·Ran Li, Abhinav K. Jha, Jie Zheng, Richard Laforest, Yongjian Liu +6 more
published similarity 0.56
Abstract

Objective. To develop an automated method for segmentation and uptake quantification of carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for partial-volume and tissue-fraction effects. Approach. Synthetic carotid PET images with known fractional-volume ground truth were generated by combining MR-derived high-resolution activity maps with GATE Monte Carlo simulation incorporating major PET physical processes and matched to the Biograph mMR acquisition and reconstruction. A two-stage network first localized the carotid vessel wall from T1-weighted MR and then estimated voxel-wise inflammation fraction from masked PET. Both stages used a multiscale residual (MSR) convolutional backbone. Performance was compared with U-Net, Transformer U-Net, DUCK-Net, and iterative Yang partial-volume correction. Main results. In a two-alternative forced-choice study, five nuclear-medicine physicians identified real images with 54% accuracy (54/100; Wilson 95% CI 0.44-0.63; exact binomial p = 0.48). On 184 simulated test slices from five held-out patients, the proposed method achieved a weighted DSC of 0.79, compared with 0.73 for U-Net, 0.69 for Transformer U-Net, and 0.75 for DUCK-Net, with corresponding HD values of 1.85, 2.29, 2.32, and 2.23 voxels. Patient-cluster bootstrap comparisons favored the proposed method for DSC and HD against all three baselines (Holm-corrected p <= 0.031). Overall ENRMSE was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang. In seven patients, corrected SUV showed a positive association with MR-derived lipid-rich/necrotic core with hemorrhage. Significance. The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions. The patient analysis is preliminary and requires external validation with biological reference standards before clinical deployment.

0.33

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

cs.CV ·2026-08-17 ·Hengjie Liu, Chushu Shen, Dan Ruan, Ke Sheng
code/data similarity 0.55
Abstract

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

0.44

Region-Weighted Losses and Model Fusion for Cross-Modal PET Attenuation Correction

cs.CV ·2026-08-22 ·Khoa Tuan Nguyen, Joris Vankerschaver, Wesley De Neve
publishedbenchmark similarity 0.55
Abstract · ntkhoa team submission for BIC-MAC MICCAI26 challenge (https://www.codabench.org/competitions/12555/#/results-tab)

We describe our approach to the Big Cross-Modal Attenuation Correction (BIC-MAC) challenge, which asks for a pseudo-CT in Hounsfield Units to be synthesized from Non-Attenuation-Corrected PET (NAC-PET), DIXON MRI and a topogram, and scores both the pseudo-CT and the Attenuation-Corrected PET (AC-PET) reconstructed from it. Three ideas carried our improvements over the organizers' 3D U-Net baseline. The loss matters more than the architecture: we compute the $L_1$ error in the Carney attenuation-coefficient ($μ$) space that the CT metric itself uses, weighted by anatomical region. Only once that loss was in place did the unregistered DIXON MRI work as extra input channels. A fixed convex combination of two independently trained models then beat both of its members on three of the four metrics and ranks first overall on the public validation leaderboard.

0.35

AsymFeX: A Symmetry-Driven Framework for Ischemic Stroke Segmentation Across Imaging Modalities and Stroke Stages

eess.IV cs.CV ·2026-08-20 ·Maunil Shah, Vaanathi Sundaresan
code/data similarity 0.54
Abstract

Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning. Non-contrast CT (NCCT), the first-line imaging modality for diagnosing ischemic infarcts, exhibits subtle infarct contrast, making manual delineation slow and labor-intensive. Motivated by this, and by the clinical practice of comparing brain hemispheres to localize infarcts, we propose a two-stage, nnU-Net-compatible 3D segmentation method. The first stage corrects head tilt to align each scan to its true anatomical mid-sagittal plane; the second applies a novel Asymmetric Feature Extraction (AsymFeX) module, comparing each voxel to its true contralateral counterpart within a local 3 x 3 x 3 neighborhood via cross-hemispheric attention, feature disparity estimation, and dual-scale gating to capture both large and small infarcts. On AISD, our method achieves 0.6796 Dice, 23.53 mm HD95, and 7.69 mL AVD, significantly outperforming existing state-of-the-art methods, with clinically relevant volumetric analysis at the 70 mL thrombolysis-eligibility threshold. Proof-of-concept evaluation on ATLAS v2.1 and ISLES'24 demonstrates that the same symmetry-driven design generalizes across imaging modalities and stroke time points without architectural changes, further supported by an uncertainty analysis assessing reliability under clinical deployment. Code is publicly available at https://github.com/biomedia-lab/AIS-detection.

0.42

Evidence Before Accuracy: A MRI-PET Fusion Network for Alzheimer Disease Classification with Causal Regional Validation

cs.CV ·2026-09-28 ·Saeid Firouzi Daghigh, Saeed Ayat
similarity 0.54
Abstract

Deep learning models for Alzheimer disease (AD) classification routinely report near-perfect discrimination, yet few are shown to rest on AD-relevant neurobiology rather than on dataset artifacts, subject-level leakage, or non-brain image content. We present a fusion network combining T1 MRI and FDG PET across axial, coronal, and sagittal planes, trained on ADNI consists of 554 paired subjects. The fusion model reaches AUC 0.962, accuracy 0.909, and F1 0.891, competitive with recent 3D CNN and multimodal transformer systems at substantially lower cost. We first quantify how much modality, plane and slice geometry matter. A validation-only search over slice centres and neighbour spacings moves AUC by 0.180 for MRI and 0.078 for PET, selecting narrow spacing for MRI and wide spacing for PET, with the chosen coronal centres falling on the hippocampal body and on the posterior cingulate respectively. The contribution, however, is the evidence layer built around that number. Shortcut controls collapse the model to AUC 0.622 (silhouette), 0.608 (exterior), and 0.500 (blank), and a label-permutation null yields 0.456. Forward region-of-interest (ROI) ablation shows that masking medial temporal cortex in MRI and the posterior default-mode network (DMN) in PET produces the largest shift in the AD logit, while area-matched controls remain indistinguishable from that null. Reverse ROI ablation shows that the medial temporal lobe alone retains 89.2% of above-chance discrimination in MRI and the posterior DMN alone retains 79.0% in PET. A quantitative comparison of attribution methods shows occlusion sensitivity reaching 3.5-5.0* enrichment inside a priori AD regions against 0.10-0.43* in controls. Ablation and attribution independently establish a biologically correct double dissociation: hippocampal evidence is carried by MRI, posterior cingulate evidence by PET.

0.12

Bridging Modalities on the Cortex: Surface-based MRI to PET Translation with a Diffusion Bridge

cs.CV cs.AI ·2026-09-17 ·Yitong Li, Alexandra Samoylova, Fabian Bongratz, Timo Grimmer, Dennis M. Hedderich +2 more
code/data similarity 0.53
Abstract

Cortical hypometabolism measured by Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a highly sensitive biomarker for dementia diagnosis. However, high costs, radiation exposure, and limited accessibility constrain its clinical utility. While cross-modal synthesis from Magnetic Resonance Imaging (MRI) offers a promising alternative, existing volumetric generation methods do not explicitly account for the highly folded cortical geometry, where disease-related patterns predominantly reside. To address this, we introduce a novel surface-based diffusion bridge framework DB-SUiT for MRI-to-PET translation that operates natively on the cortical manifold. A conditional Spherical U-shaped vision Transformer (SUiT) is specifically designed to model the intricate cross-modal relationships while preserving surface topology. It combines spherical convolutional encoders for multi-scale surface feature extraction with bottleneck Transformers to capture long-range spatial dependencies, while incorporating demographic and subcortical conditions to refine the synthesis. Evaluated on two datasets, including subjects with different dementia types, DB-SUiT demonstrates high-fidelity synthesis that substantially outperforms other baselines. In automated dementia classification, synthesized PET surfaces improve performance over MRI by 14.2% and PET volumes by 11.3%, approaching the performance of real PET surfaces. In a blinded reader study, synthetic PET achieved 85.5% diagnostic accuracy, compared with 75.8% for MRI and 95.2% for real PET. This further demonstrates cross-cohort and cross-pathology generalization, as the model was evaluated without retraining on an external cohort that included a dementia subtype not represented during training. Our code is available at https://github.com/ai-med/DB-SUiT.

0.32

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

cs.CV physics.med-phcs.LG ·2026-10-27 ·Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder +3 more
similarity 0.53
Abstract · 38 pages, 24 figures

Macromolecular pool fraction (MPF) is a quantitative imaging biomarker sensitive to myelin integrity and other changes in tissue macromolecular content, but specialized acquisitions and reconstruction methods limit its use in large-scale studies. We present a physics-guided, self-supervised deep learning framework for retrospectively estimating MPF directly from conventional clinical brain MRI ($T_1$-weighted, $T_2$-weighted, and fluid-attenuated inversion recovery [FLAIR]) without paired quantitative reference scans. The framework embeds an analytical two-pool magnetization transfer signal model that related sequence-averaged radiofrequency transmit power to apparent longitudinal relaxation. To accommodate heterogeneous clinical protocols, the network conditions intermediate features on acquisition parameters via adaptive instance normalization. It was trained and evaluated on a multisite, multivendor, multiprotocol dataset of 7,705 MRI sessions (3 T). Across 1,237 test sessions, mean MPF was $0.182 \pm 0.007$ in white matter and $0.144 \pm 0.009$ in gray matter, with limited variation across vendor-by-protocol groups (between-group coefficient of variation: 2.65% and 5.63%, respectively). In 70 sessions with demyelinating-disease labels, MPF was 35.6% lower in segmented lesions than in normal-appearing white matter. MPF maps from two different clinical protocols acquired in a healthy volunteer showed a mean voxel-wise absolute percentage difference of 7.7% and a concordance correlation coefficient of $0.888$, indicating good cross-protocol consistency. These results suggest that magnetization transfer-informed self-supervised learning enables stable MPF mapping from conventional clinical MRI, providing a scalable approach to investigate demyelinating pathology in both existing imaging archives and prospectively acquired conventional clinical scans without dedicated qMT acquisitions.

0.28