CS Paper Radar

Automated carotid artery atherosclerotic inflammation segmentation in PET using MSR-Net

Ran Li, Abhinav K. Jha, Jie Zheng, Richard Laforest, Yongjian Liu, Mohamed Zayed, Tyler J. Fraum, Barry A. Siegel, Malak Itani, Joyce C. Mhlanga, Pamela K. Woodard

cs.CV physics.med-ph ·submitted 2026-10-11 00:35 UTC · v1
published

Abstract

Objective. To develop an automated method for segmentation and uptake quantification of carotid atherosclerotic inflammation on 64Cu-CANF-comb PET while accounting for partial-volume and tissue-fraction effects. Approach. Synthetic carotid PET images with known fractional-volume ground truth were generated by combining MR-derived high-resolution activity maps with GATE Monte Carlo simulation incorporating major PET physical processes and matched to the Biograph mMR acquisition and reconstruction. A two-stage network first localized the carotid vessel wall from T1-weighted MR and then estimated voxel-wise inflammation fraction from masked PET. Both stages used a multiscale residual (MSR) convolutional backbone. Performance was compared with U-Net, Transformer U-Net, DUCK-Net, and iterative Yang partial-volume correction. Main results. In a two-alternative forced-choice study, five nuclear-medicine physicians identified real images with 54% accuracy (54/100; Wilson 95% CI 0.44-0.63; exact binomial p = 0.48). On 184 simulated test slices from five held-out patients, the proposed method achieved a weighted DSC of 0.79, compared with 0.73 for U-Net, 0.69 for Transformer U-Net, and 0.75 for DUCK-Net, with corresponding HD values of 1.85, 2.29, 2.32, and 2.23 voxels. Patient-cluster bootstrap comparisons favored the proposed method for DSC and HD against all three baselines (Holm-corrected p <= 0.031). Overall ENRMSE was 0.24 versus 0.59, 0.68, and 0.59 for the three DL baselines and 0.57 for iterative Yang. In seven patients, corrected SUV showed a positive association with MR-derived lipid-rich/necrotic core with hemorrhage. Significance. The proposed framework improved carotid PET segmentation and uptake quantification under simulated conditions. The patient analysis is preliminary and requires external validation with biological reference standards before clinical deployment.

Closest papers

Nearest neighbours by meaning across the whole index.

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.61
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

Accurate MRI-free PET Quantification and Reliability Assessment via CT-to-MRI Synthesis and Conformal Prediction

cs.CV ·2026-10-29 ·Jungwoo Seo, Seung Yun Choi, Kun Ho Lee, Seun Jeon, Byoung Seok Ye +1 more
similarity 0.60
Abstract · 28 pages, 8 figures, including supplementary material. Submitted to Medical Image Analysis

Standardized uptake value ratio (SUVR) quantification of amyloid PET commonly relies on a subject-specific T1-weighted MRI, yet a usable MRI is not always available. We therefore combined CT-to-MRI synthesis with conformal prediction for MRI-free PET quantification with reliability assessment. A slice-consistent Brownian Bridge Diffusion Model was strengthened with multi-dataset training and data-source conditioning to enrich the anatomical prior learned from MRI, and with expanded multi-slice CT context to exploit the through-plane continuity of subject-specific anatomy in CT. Synthetic MRI was used for FreeSurfer-based anatomical parcellation and PET quantification, while deep-ensemble uncertainty was calibrated with conformal prediction to estimate a plausible range for the corresponding real MRI-based SUVR. On $^{11}$C-PiB PET from OASIS-3, the proposed method achieved the highest synthesis and parcellation fidelity among the compared methods. Mean cortical SUVR from the proposed synthetic MRI agreed closely with the real MRI-based reference (MAE $0.016 \pm 0.015$, Pearson $r = 0.9987$) and yielded the same amyloid-positivity classification as the real MRI in all 87 test subjects at the prespecified cut-off. Conformal prediction achieved empirical coverage close to the prespecified levels, and at 90% target coverage, 85 of 87 subjects had prediction intervals that supported an unambiguous amyloid-positivity decision. Zero-shot evaluation on an independent external cohort showed that the proposed CT-to-MRI model could support PET quantification without retraining, although conformal calibration required target-cohort recalibration to recover the intended coverage. These findings support CT-to-MRI-based MRI-free PET quantification as a promising approach for providing accurate SUVR measurements and an explicit assessment of their reliability.

0.31

The MYOSAIQ Challenge: Myocardial Segmentation with Automated Infarct Quantification

eess.IV cs.CV ·2026-08-29 ·Olivier Bernard, William A. Romero R., Cyprien Bouton, Celia Goujat, Hang Jung Ling +22 more
top venue similarity 0.59
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:032

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.

0.55

Attention-guided super-resolution of 4D flow MRI in carotid arteries

cs.AI physics.med-phphysics.flu-dyn ·2026-09-04 ·Ali Mokhtari, Dominik Obrist
similarity 0.59
Abstract

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a powerful non-invasive technique for visualizing and quantifying complex blood flow patterns in vivo. Despite its clinical promise, broader adoption is limited by low spatial resolution and sensitivity to noise, which restrict accurate assessment of critical hemodynamic biomarkers such as wall shear stress, pressure gradients, and turbulent kinetic energy. To overcome these challenges, we propose a deep learning-based super-resolution framework that integrates multi-scale feature extraction and attention mechanisms to enhance the quality of 4D flow MRI data. The model was trained on a dataset of 120 patients with 240 stenosed carotid arteries. High-resolution ground truth data were generated using patient-specific computational fluid dynamics (CFD) simulations based on segmented vascular geometries and physiologically realistic boundary conditions, and the resulting velocity fields served as targets for supervised learning. The proposed architecture uses convolutional block attention modules (CBAM) to guide the network toward clinically relevant spatial features and to suppress noise in low-resolution inputs. Quantitative results show that the attention-guided model substantially reduces the root mean square error (RMSE) compared with a baseline model without attention, and qualitative velocity contour analysis confirms improved reconstruction of intricate flow patterns. These findings highlight the capacity of the model to restore high-fidelity flow fields under noisy conditions and support the use of deep learning to extend the clinical utility of 4D flow MRI for non-invasive hemodynamic assessment.

0.25

DeepPV-MRF: End-to-End Partial-Volume Fraction Estimation from MR Fingerprinting Time Series

eess.SP cs.AI ·2026-10-14 ·Tianyi Ding, Yang Gao, Zhuang Xiong, Feng Liu, Martijn A. Cloos +2 more
similarity 0.59
Abstract

Background: Estimating subvoxel tissue fractions from magnetic resonance fingerprinting (MRF) is challenging. Conventional dictionary matching and segmentation pipelines can propagate errors from intermediate parametric maps into tissue fraction estimates. Purpose: We introduce DeepPV-MRF, a deep learning framework that directly estimates voxel-wise tissue fractions from raw MRF signals. Methods: A cascaded spatial-temporal network was trained on subject-derived Bloch simulations with radial k-space undersampling. The network combines temporal encoding and spatial U-Net refinement to estimate cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM) fractions without intermediate T1/T2 maps. We compared DeepPV-MRF with partial-volume dictionary matching (PV-DM) and pseudoinverse estimation (PV-Pinv) using simulated and in vivo data. Results: DeepPV-MRF outperformed both methods across acquisition settings. In single-shot simulations, CSF/WM/GM mean absolute errors were 0.0418/0.0744/0.0757, versus 0.1281/0.2443/0.2958 for PV-DM and 0.2021/0.2793/0.2630 for PV-Pinv. Corresponding structural similarity values were 0.960/0.916/0.922. In vivo results showed sharper anatomical boundaries and smoother tissue transitions, while cross-shot analysis indicated improved consistency across volunteers. Conclusions: DeepPV-MRF enables accurate and efficient direct tissue fraction estimation from MRF signals, particularly with limited shots. Further validation is needed before clinical deployment.

0.14

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.58
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.58
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52

PET Quantification-Preserving Registration for Longitudinal Whole-Body PSMA PET/CT

cs.CV ·2026-10-15 ·Fryderyk Kögl, Anna Reithmeir, Daniel M. Lang, Emily Chan, Rickmer Braren +1 more
code/datahot direction similarity 0.58
Abstract

We adapt the diffeomorphic coarse-to-fine LapIRN architecture for longitudinal whole-body PSMA PET/CT registration in the Learn2Reg 2026 PSMAReg challenge. The method combines affine pre-registration, multi-modal deformable registration, and test-time instance optimization. We further introduce PET biomarker preservation losses for metabolic tumor volume (MTV) and total lesion glycolysis (TLG), including Jacobian-based constraints, and a per-structure rigidity regularization for skeletal structures. The submitted configuration achieved 81.0% DSC and 6.17 mm HD95, with MTV and TLG errors of 3.3% and 3.3%, respectively, on our evaluation protocol. Code is available at https://github.com/koegl/psmareg.

0.37