CS Paper Radar

Reliability-Role Collaborative Learning for Semi-Supervised Cardiac Image Segmentation

Zhongrui Xie, Wenfeng Zhang, Wei Hu, Ruitao Xie, Wenjie Wang, Zhouyun Xie, Yi Zhang, Tao Jia

cs.CV ·submitted 2026-11-03 03:01 UTC · v1
published

Abstract

Semi-supervised cardiac image segmentation aims to exploit abundant unlabeled images together with limited annotations, but the reliability of pseudo-label supervision is highly uneven across spatial regions. In a dual-network setting, interior regions are usually more stable, whereas boundary regions, low-confidence areas, and disagreements between networks can introduce noisy supervision. However, existing methods typically impose uniform supervision on all unlabeled pixels, overlooking reliability differences and limiting discriminative learning in challenging areas. To address this issue, we propose R2CL (Reliability-Role Collaborative Learning), a framework for semi-supervised cardiac image segmentation. R2CL models confidence relationships between two networks to assign roles to unlabeled regions: mutually uncertain regions are used for entropy regularization, confidence-discrepant regions for directional knowledge transfer, and mutually confident regions as reliable supervision anchors. Reliability-Role Mixed Cross Learning (RR-MCL) implements these roles through region-mixed training, directional cross-network supervision, and entropy regularization over mutually uncertain regions. Reliability-Transition Prototype Contrastive Learning (RT-PCL) constructs query features from foreground-adjacent reliability-transition regions and learns network-specific class prototypes from mutually confident regions, improving feature discrimination around ambiguous boundaries. High-confidence Context Refinement (HCR) exploits reliable interior pixels and trusted dense blocks within mutually confident regions to complement stable contextual supervision. R2CL achieves stable improvements in region-overlap and boundary-related metrics across multiple datasets, with more evident advantages on the foreground-sparse MVAA-CT dataset.

Comment
Accepted at IEEE BIBM 2026. 7 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

ProGeo-RC: Prototype-guided Semantic Reliability and Geometric Error Calibration for Semi-supervised Cardiac Image Segmentation

cs.CV ·2026-11-03 ·Yunfei Zhu, Wenfeng Zhang, Pan Zeng, Xin Huang, Tao Jia +3 more
published similarity 0.74
Abstract · Accepted at IEEE BIBM 2026. 7 pages, 3 figures

Semi-supervised medical image segmentation aims to train reliable segmentation models using limited labeled data and abundant unlabeled data. However, existing methods typically rely on prediction confidence or model consistency to estimate pseudo-label reliability, but these criteria are insufficient to characterize both semantic reliability and geometric plausibility. To address this issue, we propose ProGeo-RC, a prototype-guided semantic reliability and geometric error calibration framework for semi-supervised medical image segmentation. ProGeo-RC consists of two key modules: Prototype-guided Semantic Reliability Estimation (PSRE) and Structured Semantic-Geometric Error Calibration (S-SGEC). PSRE uses probabilistic class prototypes to estimate the semantic reliability of unlabeled predictions and calibrate pixel-wise teacher pseudo labels, while S-SGEC introduces signed-distance-field-based geometric constraints to refine ambiguous boundaries and suppress spurious foreground responses outside target structures. Experiments on the ACDC and MVAA-CT datasets show that ProGeo-RC achieves better performance compared with representative semi-supervised segmentation methods. Under the 10\% labeled setting on ACDC, ProGeo-RC improves DSC and Jaccard by 0.37\% and 0.49\% over the corresponding second-best results, while reducing 95HD and ASD by 0.61 and 0.21, respectively. These results indicate that joint semantic reliability estimation and geometric error calibration can provide more reliable pseudo supervision for semi-supervised medical image segmentation.

0.32

SAUF-Net: Structure--Appearance Representation Learning with Uncertainty Feedback for Semi-Supervised Medical Image Segmentation

cs.CV cs.AI ·2026-09-02 ·Qin Lu, Zheyang Jing, Yujie Yang, Jianwang Li, Chen Yi +1 more
published similarity 0.71
Abstract

Semi-supervised learning has shown great potential for reducing annotation costs in medical image segmentation. However, most existing methods mainly exploit unlabeled data through prediction-level consistency, while the reliability of internal feature representations is often overlooked. In medical images, target-related structural cues are easily entangled with unstable appearance variations, which may lead to unreliable pseudo labels and error accumulation during training. To address these issues, we propose SAUF-Net, a Structure--Appearance Representation Learning with Uncertainty Feedback Network for semi-supervised medical image segmentation. SAUF-Net uses the Structure--Appearance Decomposition Module (SADM) to separate bottleneck features into structural and appearance representations. The Disentangled Guidance Module (DGM) injects these representations into the decoding process to enhance structure-aware segmentation. Meanwhile, the Auxiliary Decoder produces branch-specific predictions for reliability estimation and a fused prediction for appearance-swapped consistency. Furthermore, we introduce an Appearance-Swapped Consistency branch to encourage structural representations to remain stable under appearance variations. We also introduce a reliability-map-guided dual-head discriminator with a Validity Head and an Uncertainty Head to provide feature-level uncertainty feedback. Extensive experiments on ISIC-2016 and Kvasir-SEG demonstrate that SAUF-Net outperforms state-of-the-art semi-supervised methods, especially under low-label settings.

0.43

CalcSeg: Confidence-aware 3D Latent Context Curriculum Learning For Myocardial Scar Segmentation From Single-Stack LGE-CMRs

cs.CV ·2026-08-20 ·Nivetha Jayakumar, Hannah Kim, Amit R. Patel, Miaomiao Zhang
top venuebenchmarkcode/data similarity 0.67
Abstract

Myocardial scar segmentation from single-stack late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) imaging has been a longstanding and clinically important challenge, particularly in the presence of low tissue contrast, diffuse, and small scar regions. These challenges are further intensified by the limited availability of 3D spatial context. This paper presents CalcSeg, a Confidence-aware latent context curriculum learning framework that leverages fused 3D feature representations from single-stack 2D LGE-CMR images for robust scar segmentation. Specifically, we introduce a dynamic semi-supervised curriculum learning strategy that progressively expands training from easier to more challenging scar cases using a learned confidence-aware scoring function. Such a function integrates errors in the predicted scar maps with quantified epistemic uncertainty and scar burden estimation to automatically assess sample difficulty without requiring manual labels. To compensate for the limited spatial context in single-stack acquisitions, we then develop a latent slice-wise self-attention to capture inter-slice dependencies and infer 3D spatial representations from sparse 2D inputs. We evaluate CalcSeg on multi-center clinical LGE-CMR datasets and benchmark against existing scar segmentation networks. Experimental results show that CalcSeg consistently outperforms all competing methods, particularly with substantial improvements on clinically challenging cases. Our code is released on Github.

0.44

Beyond Accuracy: Uncertainty-Guided Boundary Refinement for Reliable Biomedical Image Segmentation

cs.CV cs.LG ·2026-09-11 ·Anima Kujur
similarity 0.66
Abstract

Accurate biomedical image segmentation requires not only high global overlap but also reliable delineation of clinically meaningful boundaries. In blood-smear microscopy, cytoplasm and nucleus contours provide the structural basis for downstream morphology analysis; however, deep segmentation models may remain uncertain or overconfident near ambiguous boundary regions even when achieving strong Dice scores. This work proposes a Reliability-Aware Boundary Refinement Network (RABR-Net), a two-stage framework for trustworthy image segmentation. A strong UNet++ EfficientNet-B4 base segmenter first produces initial class probabilities and logits. Predictive entropy, test-time augmentation variance, margin uncertainty, probability gradients, and soft boundary cues are then combined into a boundary-aware reliability representation. This representation guides a gated residual refiner that selectively corrects uncertain boundary pixels while preserving confident regions of the base prediction. The framework is evaluated using overlap accuracy, class-wise Dice, Boundary Dice, HD95/ASSD, calibration, risk--coverage analysis, robustness under image perturbations, qualitative correction maps, and paired statistical testing. On the held-out test set, the proposed method improves Dice from 0.9602 to 0.9614, Boundary Dice from 0.3448 to 0.3611, and HD95 from 3.0354 to 2.8274 compared with the cached base prediction. Statistical analysis confirms significant improvements in Dice, Boundary Dice, and HD95. Qualitative results show that the learned gate concentrates around uncertain cytoplasm and nucleus boundaries, and correction maps confirm localized boundary refinement. Although calibration does not automatically improve after refinement, the proposed framework provides an interpretable and reliability-focused strategy for boundary-sensitive biomedical image segmentation.

0.22

HDVS: semi-supervised semantic segmentation via heterogeneous dual-branch voting supervision

cs.CV ·2026-10-27 ·Yongqi Shan, Yunzhi Zhuge, Huchuan Lu
publishedbenchmark similarity 0.65
Abstract · 16 pages, 9 figures, 7 tables. Published in Visual Intelligence

Semi-supervised semantic segmentation, which aims to utilize large volumes of unlabeled images to achieve accurate segmentation results with fewer human annotations, has attracted increasing attention. Prior methods were primarily based on the assumption that the pseudo-labels generated by each branch were sufficiently reliable to supervise the remaining branches. However, there is a concern that the errors in pseudo-labels could accumulate during co-training, potentially resulting in suboptimal performance. To this end, we present a novel framework called heterogeneous dual-branch voting supervision (HDVS), which is designed to enhance the reliability of pseudo-labels and mitigate the issues arising from pseudo-labeling. Specifically, based on the cross-supervision framework, we introduce a voting mechanism that correlates pseudo-labels from heterogeneous branches to produce pseudo-labels with enhanced reliability. Concurrently, we employ a feature communication module to introduce perturbations at the feature level in each branch to maximize prediction diversity across the dual branches while maintaining convergence. Comprehensive evaluations of the proposed HDVS on two benchmark datasets (PASCAL VOC 2012 and Cityscapes) demonstrate its superiority to the state-of-the-art approaches.

0.52

Confidence-Aware Teacher-Student Distillation for 3D Medical Segmentation

cs.CV ·2026-09-20 ·Georgios Triantafyllou, Dimitris K. Iakovidis
theory similarity 0.65
Abstract

Medical image segmentation models typically rely on large amounts of densely annotated volumetric data, limiting their scalability across tasks and imaging modalities. This work addresses the challenge of predicting entire 3D anatomical structures from extreme annotation sparsity. An annotation-efficient student-teacher framework is proposed for automatic 3D medical segmentation that requires only a set of point prompts on a single 2D slice per volume, as input. A foundation model serves as an offline teacher, utilizing the provided point prompts from the selected slice to full-volume pseudo-annotations alongside their corresponding spatial confidence scores prior to student training. To mitigate the error propagation of noisy pseudo-annotations, a task-specific 3D student network is trained using a confidence-aware optimization strategy. By leveraging the teacher's pre-computed confidence scores, this strategy explicitly excludes statically uncertain regions of the pseudo-annotations from the loss calculation, while simultaneously emphasizing regions with higher confidence. Evaluated on 3D cardiac MRI datasets, our framework outperforms state-of-the-art semi-supervised methods, improving segmentation performance by up to 43.6%. Furthermore, it drastically reduces the manual annotation burden to just a few positive point prompts per volume, while improving surface boundary precision by up to 14.7% over the teacher and successfully recovering up to 34.1% of the performance gap toward the fully supervised upper bound.

0.22

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.63
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.20

LISynSeg: Data-Centric Label-to-Image Synthesis for Cross-Modality Whole-Heart Segmentation

cs.CV eess.IV ·2026-08-31 ·Jiacheng Wang, Ivana Isgum, Ipek Oguz
benchmarkcode/data similarity 0.63
Abstract · 12 pages, 4 figures

Whole-heart segmentation (WHS) in computed tomography (CT) and magnetic resonance imaging (MRI) is affected by acquisition shifts and heterogeneous cardiac annotations. Existing WHS systems combine architectural design, transfer learning, and generic spatial or intensity augmentation. We investigate whether changes to data augmentation and training supervision can improve cross-modality WHS while the segmentation architecture is held constant. We present LISynSeg, a data-centric approach that augments real-image nnU-Net training with label-to-image synthesis. Synthetic volumes are generated from cardiac label maps using contrast and acquisition perturbations calibrated to the training cohort, then mixed with real images to retain thoracic context absent from the labels (and thus the synthesized images). We model cardiac label variation through controlled changes in myocardial wall thickness and partial supervision of uncertain vessel endpoints. On the CARE Whole-Heart benchmark, synthetic-only training performs worse than the real-image nnU-Net baseline, whereas calibrated real-synthetic training improves cross-modality segmentation without changing the architecture; the improvement is larger for MRI than for CT. The results show that modifying the training data strategy can benefit model development for heterogeneous cardiac data. Code and trained weights will be released at https://github.com/MedICL-VU/Care26_LISynSeg.

0.38