CS Paper Radar

Frequency-Frame Covariance for Reactive-Power Scalarization

Kai Sun

eess.SP eess.SYmath-ph ·submitted 2026-11-04 04:04 UTC · v1

Abstract

Measured voltage and current waveforms may be represented in a reference frame whose frequency differs from the physical fundamental frequency. Reactive-power readouts calculated from such frequency-shifted coordinates may change if their readout operators are not transformed consistently. This paper presents a frequency-frame covariance formulation for finite-spectrum, zero-mean periodic waveforms with complete harmonic information over one physical period. A necessary and sufficient covariance condition is derived, requiring the readout operator to transform consistently with the waveform representation. Consequently, frequency-dependent harmonic weights must be evaluated at physical harmonic orders rather than relative frame labels. In particular, the derivative/Iliovici readout equals a relative-derivative contribution plus an explicit reference contribution. The formulation also separates readout-operator errors from errors caused by changes in the physical components retained by waveform projections. Three analytical cases illustrate conditional carrier recovery for a memoryless resistor, physical-frequency weighting at relative zero in an RLC branch, and the possibility that an exact reactive-power scalar can coexist with a substantial waveform error after projection. The scope is deterministic calculation consistency in frequency-shifted coordinates rather than instrument measurement uncertainty.

Closest papers

Nearest neighbours by meaning across the whole index.

Reactive Power Beyond Sinusoids: Scalar Measurement Readouts and Information Limits

eess.SY ·2026-09-21 ·Kai Sun
unusual similarity 0.77
Abstract

Reactive power is not uniquely defined for nonsinusoidal voltage and current waveforms because different scalar readouts can assign different values to the same measured voltage--current waveform pair. This paper characterizes which scalar readouts are selected by specific measurement and physical requirements, and quantifies the current information lost through scalarization. The scalar readout is first restricted by requiring bilinearity, alternation, and invariance to the measurement time origin. Requiring it to vanish for all smooth, strictly monotone, time-invariant memoryless resistors then forces the harmonic weights to be proportional to harmonic order. With consistency across harmonic cutoffs and fundamental-frequency calibration, this uniquely yields the classical derivative, or Iliovici-type, scalar within the stated class. The selected weighting is also incompatible with conventional reactive-power calibration independently at every harmonic. Furthermore, for known nonzero voltage, active power and a finite set of skew scalar readouts leave an affine family of compatible currents of exact dimension \(d-1-r_v\). These results establish explicit selection and information-loss limits for scalar reactive-power measurements under nonsinusoidal conditions.

0.46

Identification of $dq$-Asymmetric Impedances as Complex Transfer Functions Using a Single Arbitrary Excitation

eess.SP eess.SY ·2026-08-30 ·Mohamed Abdalmoaty, Zheran Zeng, Dongsheng Yang, Florian Dörfler
similarity 0.56
Abstract

Cross-coupling between the $dq$ coordinates makes the identification of asymmetric grid impedances a challenging problem, particularly near the fundamental frequency where the asymmetric coupling is strongest. Existing schemes usually handle it either by perturbing the two coordinates sequentially, which lengthens the measurement, or by using a time-domain method with a global parametric model whose order must be tuned. This paper develops a single-shot active non-parametric frequency-domain method that avoids both. The equivalent impedance is parameterized by a pair of single-input single-output complex transfer functions. Each spectral line is fitted with a local rational model; the leakage and transient contributions are estimated, so that neither periodic steady-state excitation nor repeated excitation cycles are required. We give the exact finite-time discrete Fourier transform relation for the conjugate-coupled complex-signal model, and analyse the distortion that a stationary-frame filter placed ahead of the Park transform imposes on the identified pair. The method is validated on a controller hardware-in-the-loop platform against an analytically derived small-signal model, for a symmetric grid and for the same grid with an added grid-following converter that renders it asymmetric. Both complex transfer functions and all four real transfer functions of the $dq$ impedance are recovered over a wide band from a single one-second record of a random excitation, at 1 Hz resolution.

0.26

Phase-Compensated Frequency-Scan Measurement of Harmonic Transfer Function Impedance

eess.SY ·2026-10-28 ·Yiyang Liao, Yitong Li, Jinjun Liu
similarity 0.53
Abstract

Impedance models obtained through frequency scanning provides terminal characterization for small-signal stability analysis without requiring detailed knowledge of internal converter parameters. When unbalanced steady-state components introduce cross-frequency coupling, conventional $2\times2$ impedance scan methods must be extended to identify harmonic transfer function (HTF) impedance. However, the measured phases of frequency-coupling terms depend on the starting time of the fast Fourier transform (FFT) window, potentially introducing phase errors when different time references are used. This paper presents a $dq$-domain measurement method of HTF impedance that explicitly accounts for this time dependence. Phase compensation aligns the measured Fourier coefficients to a common electrical phase reference, correcting the resulting phase discrepancies and enabling consistent impedance reconstruction. Comparisons with analytical models under balanced and unbalanced conditions verify the measurement method, recovering the conventional $2\times2$ impedance and the dominant coupling blocks of a $6\times6$ HTF representation, respectively.

0.34

High-Order Sinusoidal Modeling for Precise Parameter Refinement

eess.SP eess.AS ·2026-10-15 ·Shaowen Chen, Tomoki Toda
unusual similarity 0.53
Abstract · This manuscript is currently under review for publication in the IEEE Transactions on Signal Processing. This work has been submitted to the…

Although the amplitude estimation of sinusoids is a linear and tractable problem when their frequencies are known, the accuracy of signal modeling is fundamentally limited by the inevitable frequency mismatches produced by existing methods. Quasi-harmonic modeling (QHM) and its extensions (aQHM and eaQHM) offer the ability to refine frequency estimates while extracting amplitudes; however, their extraction and correction capabilities remain limited. In this paper, we first revisit QHM methods from the perspective of frequency mismatches, and reveal that their performances are essentially constrained by the order of the model. Specifically, QHM methods are linear models and thus incapable of capturing higher-order frequency variations, leading to suboptimal modeling accuracy. Second, to address this limitation, we propose a higher-order modeling framework that enables more precise approximation of signal components. Eventually, we qualitatively characterize the optimization problem and employ the Levenberg--Marquardt (LM) algorithm for parameter estimation. As a result, the proposed method allows for significantly improved estimation of amplitudes, frequencies, and phases of sinusoidal components, enabling more accurate signal modeling. Experiments on both simulation study and speech signals demonstrate the superiority of the high-order model in frequency refinement and parameter extraction and its robustness under additive noise conditions.

0.24

Quantifying Power to Voltage and Frequency Dynamics for Oscillation Propagation Assessment

eess.SY ·2026-09-03 ·Onur Alican, Dionysios Moutevelis, Marc Cheah-Mañe, Oriol Gomis-Bellmunt, Eduardo Prieto-Araujo
benchmark similarity 0.52
Abstract

The integration of Inverter-Based Resources (IBRs) into power systems introduces multi-timescale dynamics and oscillations which may propagate to distant areas and endanger the safe system operation. These oscillations pose a significant challenge as their source, frequency, and propagation pathways are often challenging to identify in large interconnected systems, comprising numerous synchronous machines and IBRs. For the above reasons, analytical tools that identify the sensitivity of the system to oscillations within a large frequency spectrum, affecting both voltage and frequency variables across various network locations, are of interest. This paper addresses this topic by introducing a frequency-domain framework based on linear analysis, which characterizes the sensitivity to oscillations of each network bus voltage and of each generation unit frequency. Within this framework, two quantitative indicators are proposed, namely the Frequency Sensitivity Index (FSI) and Voltage Sensitivity Index (VSI). These indexes are derived analytically from the transfer functions which relate the active and reactive power injections to each bus with the voltage and frequency variables across the network, derived from the linear Electromagnetic Transient (EMT) power system model. The proposed indices quantify the sensitivity of the system to oscillations of different type and frequency, providing insights for both oscillation detection and propagation analysis. The methodology is applied to a case study based on the modified IEEE 68-bus benchmark system under partial and full IBR penetration, while its accuracy is validated through EMT time-domain simulations using linear and nonlinear models developed in Matlab/Simulink environment.

0.29

A New Index for Quantifying Stability Adaptation Effort in Power Electronics-Dominated Power Systems Based on Frequency-Domain Impedance Identification

eess.SY ·2026-10-02 ·Luis A. Garcia-Reyes, Macarena Martin-Almenta, Edgar Nuño-Martínez, Javier Renedo, Antonio Cordón-Rodríguez +2 more
published similarity 0.51
Abstract · Paper in Proceedings of CIGRE Paris Session, C4-PS1, Paper ID 11553

The increasing use of converter based resources has made stability assessment in modern power systems more challenging, particularly because many devices are available only as black box models. Conventional eigenvalue based methods require full dynamic representations, while frequency domain impedance techniques based on the Generalized Nyquist Criterion (GNC) provide stability insight but do not quantify how much a converter must be retuned to restore stability. This paper introduces the Adaptation Effort Index (AEI), a metric that measures the sensitivity of dominant modes to parameter variations and quantifies the effort required for a converter to reconfigure itself under unstable operating conditions. The AEI combines the Nyquist Stability Margin obtained from frequency domain screening with a modal sensitivity index derived from fitted state space models synthesized from black box impedance data. The method is applied to a system comprising a grid forming and a grid following converter. Results show that, although both units can be tuned to stabilize the system, the grid following converter requires significantly less adaptation effort. The AEI therefore provides a practical and model agnostic tool for identifying which converter should be reconfigured in converter dominated grids, offering valuable guidance for system operators and manufacturers.

0.30

Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation

eess.SY ·2026-10-28 ·Songyang Zhang, Xun Gong, Bo Cao, Reza Iravani
similarity 0.51
Abstract

Passive grid impedance estimators that return a single resistance--inductance pair cannot represent a grid whose phase impedances are unequal. This paper identifies a separate pair for each phase from recorded point-of-common-coupling (PCC) voltage and current without injected perturbations. In each phase, the unknown grid-source voltage is cancelled by a periodic difference (PD) or by a second-order-generalized-integrator notch difference (SOGID), and moving-window integration (MWI) replaces the current derivative by an integral and an endpoint feature. The resulting two-parameter regression requires a period or notch-frequency estimate but no phase-locked-loop angle. A voltage-balance analysis gives the source residual left by frequency mismatch and bounds the parameter error by the ratio of this residual to the conditioning of the two features. In the unequal-phase interval (8.3--9.8~s) of a 10-s EMTP grid-forming record, SOGID-MWI attains phase-averaged R/L errors of 5.09/0.33\%; a shared value has a minimum error of 41.67\% for the phase ratio 1:0.5:2. On a 50-s constant-impedance grid-following record, the errors are 0.56/0.06\% over the 20--30-s synchronization disturbance. In a controlled 40-dB noise study, a noise-referenced update rule reduces the white-noise GFL error from 55.9/65.0\% to 12.3/11.5\%.

0.34

Beyond Scalar Inertia: Frequency-Response-Based Assessment of Finite-Duration Inertial Support in Grid-Forming Converters

eess.SY ·2026-11-13 ·Ziqi Zhou, Mahdieh S. Sadabadi, Sante Pugliese, Xiaoqiang Li, Xiaojie Wu +1 more
hot direction similarity 0.51
Abstract · This paper has 6 pages with 5 figures. The target journal will be determined at a later stage

Conventional scalar inertia characterizes only the low-frequency terminal behavior of grid-forming converters (GFMs) and cannot fully predict inertial energy delivery during short-duration frequency disturbances. This letter proposes a frequency-response-based method to assess finite-duration inertial support using complex terminal power--frequency responses, such as those provided by Network Frequency Perturbation (NFP) plots. For GFMs with nonzero steady-state droop, a duration-dependent energy-equivalent inertia is defined after subtracting the ideal static-droop contribution. An exact spectral relationship is established, expressing this metric as a duration-weighted integral of frequency-dependent inertia, without requiring knowledge of the internal controller structure and parameters. The duration dependence of the metric is further shown to encode observable oscillation frequencies and damping ratios. A coefficient-decoupling GFM control with identical scalar inertia and droop across different settings is used for verification.

0.34