CS Paper Radar

Reactive Power Beyond Sinusoids: Scalar Measurement Readouts and Information Limits

Kai Sun

eess.SY ·submitted 2026-09-21 19:18 UTC · v2
unusual

Abstract

Reactive power is not uniquely defined for nonsinusoidal voltage and current waveforms because different scalar readouts can assign different values to the same measured voltage--current waveform pair. This paper characterizes which scalar readouts are selected by specific measurement and physical requirements, and quantifies the current information lost through scalarization. The scalar readout is first restricted by requiring bilinearity, alternation, and invariance to the measurement time origin. Requiring it to vanish for all smooth, strictly monotone, time-invariant memoryless resistors then forces the harmonic weights to be proportional to harmonic order. With consistency across harmonic cutoffs and fundamental-frequency calibration, this uniquely yields the classical derivative, or Iliovici-type, scalar within the stated class. The selected weighting is also incompatible with conventional reactive-power calibration independently at every harmonic. Furthermore, for known nonzero voltage, active power and a finite set of skew scalar readouts leave an affine family of compatible currents of exact dimension \(d-1-r_v\). These results establish explicit selection and information-loss limits for scalar reactive-power measurements under nonsinusoidal conditions.

Closest papers

Nearest neighbours by meaning across the whole index.

Frequency-Frame Covariance for Reactive-Power Scalarization

eess.SP eess.SYmath-ph ·2026-11-04 ·Kai Sun
similarity 0.77
Abstract

Measured voltage and current waveforms may be represented in a reference frame whose frequency differs from the physical fundamental frequency. Reactive-power readouts calculated from such frequency-shifted coordinates may change if their readout operators are not transformed consistently. This paper presents a frequency-frame covariance formulation for finite-spectrum, zero-mean periodic waveforms with complete harmonic information over one physical period. A necessary and sufficient covariance condition is derived, requiring the readout operator to transform consistently with the waveform representation. Consequently, frequency-dependent harmonic weights must be evaluated at physical harmonic orders rather than relative frame labels. In particular, the derivative/Iliovici readout equals a relative-derivative contribution plus an explicit reference contribution. The formulation also separates readout-operator errors from errors caused by changes in the physical components retained by waveform projections. Three analytical cases illustrate conditional carrier recovery for a memoryless resistor, physical-frequency weighting at relative zero in an RLC branch, and the possibility that an exact reactive-power scalar can coexist with a substantial waveform error after projection. The scope is deterministic calculation consistency in frequency-shifted coordinates rather than instrument measurement uncertainty.

0.13

Passive Identification of Unequal Phase Grid Impedances by Phase-Domain Source Cancellation

eess.SY ·2026-10-28 ·Songyang Zhang, Xun Gong, Bo Cao, Reza Iravani
similarity 0.49
Abstract

Passive grid impedance estimators that return a single resistance--inductance pair cannot represent a grid whose phase impedances are unequal. This paper identifies a separate pair for each phase from recorded point-of-common-coupling (PCC) voltage and current without injected perturbations. In each phase, the unknown grid-source voltage is cancelled by a periodic difference (PD) or by a second-order-generalized-integrator notch difference (SOGID), and moving-window integration (MWI) replaces the current derivative by an integral and an endpoint feature. The resulting two-parameter regression requires a period or notch-frequency estimate but no phase-locked-loop angle. A voltage-balance analysis gives the source residual left by frequency mismatch and bounds the parameter error by the ratio of this residual to the conditioning of the two features. In the unequal-phase interval (8.3--9.8~s) of a 10-s EMTP grid-forming record, SOGID-MWI attains phase-averaged R/L errors of 5.09/0.33\%; a shared value has a minimum error of 41.67\% for the phase ratio 1:0.5:2. On a 50-s constant-impedance grid-following record, the errors are 0.56/0.06\% over the 20--30-s synchronization disturbance. In a controlled 40-dB noise study, a noise-referenced update rule reduces the white-noise GFL error from 55.9/65.0\% to 12.3/11.5\%.

0.34

Identification of $dq$-Asymmetric Impedances as Complex Transfer Functions Using a Single Arbitrary Excitation

eess.SP eess.SY ·2026-08-30 ·Mohamed Abdalmoaty, Zheran Zeng, Dongsheng Yang, Florian Dörfler
similarity 0.48
Abstract

Cross-coupling between the $dq$ coordinates makes the identification of asymmetric grid impedances a challenging problem, particularly near the fundamental frequency where the asymmetric coupling is strongest. Existing schemes usually handle it either by perturbing the two coordinates sequentially, which lengthens the measurement, or by using a time-domain method with a global parametric model whose order must be tuned. This paper develops a single-shot active non-parametric frequency-domain method that avoids both. The equivalent impedance is parameterized by a pair of single-input single-output complex transfer functions. Each spectral line is fitted with a local rational model; the leakage and transient contributions are estimated, so that neither periodic steady-state excitation nor repeated excitation cycles are required. We give the exact finite-time discrete Fourier transform relation for the conjugate-coupled complex-signal model, and analyse the distortion that a stationary-frame filter placed ahead of the Park transform imposes on the identified pair. The method is validated on a controller hardware-in-the-loop platform against an analytically derived small-signal model, for a symmetric grid and for the same grid with an added grid-following converter that renders it asymmetric. Both complex transfer functions and all four real transfer functions of the $dq$ impedance are recovered over a wide band from a single one-second record of a random excitation, at 1 Hz resolution.

0.26

Symmetry and the Form of Nonlinear Behavioral Models: A Tutorial for Microwave Engineers

eess.SP ·2026-10-01 ·Nicholas B. Tufillaro
similarity 0.48
Abstract · 25 pages, 7 figures, 4 tables. v3: one sentence in the Scope section corrected (multi-harmonic and multi-port cases use the single circle; o…

Behavioral models of nonlinear microwave devices -- the Cardiff model, X-parameters, the higher-order describing functions of the mechanical-systems literature -- all share a functional form. This tutorial derives that form from time invariance alone. It develops the consequences of that derivation using only the harmonic-balance description of a single-tone periodic steady state, in which each port waveform is a finite set of harmonic phasors, and uses them to give the Cardiff model's three exponents physical interpretations. In the monomial rewriting the magnitude exponent $m$ is the order of the device's load-side nonlinearity; the phase exponent $n$ is set by the drive-side harmonic; and the conjugate index $r$ obeys $r_{\max}=\lfloor K/2\rfloor$, where $K$ is the degree of the load-side nonlinearity. The familiar restriction $r\le1$ is therefore a statement about the device, exact whenever $K\le3$. The final sections show that a tailored A-pull measurement displays this decomposition directly: each spectral cluster's half-width is the order of the nonlinearity that produced it. The tutorial is pedagogical and is meant as a gentler introduction to the results treated in the companion paper "Time invariance, circle symmetry, and the completeness of the Cardiff behavioral model", which states and proves the theorems in full.

0.35

High-Order Sinusoidal Modeling for Precise Parameter Refinement

eess.SP eess.AS ·2026-10-15 ·Shaowen Chen, Tomoki Toda
unusual similarity 0.48
Abstract · This manuscript is currently under review for publication in the IEEE Transactions on Signal Processing. This work has been submitted to the…

Although the amplitude estimation of sinusoids is a linear and tractable problem when their frequencies are known, the accuracy of signal modeling is fundamentally limited by the inevitable frequency mismatches produced by existing methods. Quasi-harmonic modeling (QHM) and its extensions (aQHM and eaQHM) offer the ability to refine frequency estimates while extracting amplitudes; however, their extraction and correction capabilities remain limited. In this paper, we first revisit QHM methods from the perspective of frequency mismatches, and reveal that their performances are essentially constrained by the order of the model. Specifically, QHM methods are linear models and thus incapable of capturing higher-order frequency variations, leading to suboptimal modeling accuracy. Second, to address this limitation, we propose a higher-order modeling framework that enables more precise approximation of signal components. Eventually, we qualitatively characterize the optimization problem and employ the Levenberg--Marquardt (LM) algorithm for parameter estimation. As a result, the proposed method allows for significantly improved estimation of amplitudes, frequencies, and phases of sinusoidal components, enabling more accurate signal modeling. Experiments on both simulation study and speech signals demonstrate the superiority of the high-order model in frequency refinement and parameter extraction and its robustness under additive noise conditions.

0.24

Equivalent DQ Sequence-Domain Model of Unbalanced Three-Phase Passive Elements for Power Converter Controllers

eess.SY ·2026-09-01 ·Air\án Franc\és, Luis Saz, Rafael Castillo, Dionisio Ramirez, Javier Uceda
publishedtheoryhighly cited similarity 0.46
Abstract · 8 pages, 7 figures, 2023 IEEE Applied Power Electronics Conference and Exposition (APEC)

Equivalent dq0 models of three-phase passive impedances are widely used for the design of three-phase inverter and rectifier controllers in the synchronous frame. However, these equivalent models assume that the impedance in each phase are the same, which is not always applicable. The fact that the impedance in each phase is different, generates second order harmonic content in the dq0 components, which hinders the advantages of the dq0 transformation. To avoid the second harmonic in these scenarios, it is possible to use the Fortescue's theorem to represent any asymmetrical set of three-phase signals as a linear combination of three symmetrical sequences. In the literature, only a few works have attempted to derive the equivalent model of unbalanced three-phase passive elements in the sequence domain, and none is able to account for the interaction between the zero sequence and the positive and negative sequences. This work presents the derivation of the equivalent dq sequence-domain model of unbalanced three-phase passive elements both analytically and with an intuitive graphical approach. Experimental results are shown to validate the proposed models.

0.73

Phase-Compensated Frequency-Scan Measurement of Harmonic Transfer Function Impedance

eess.SY ·2026-10-28 ·Yiyang Liao, Yitong Li, Jinjun Liu
similarity 0.46
Abstract

Impedance models obtained through frequency scanning provides terminal characterization for small-signal stability analysis without requiring detailed knowledge of internal converter parameters. When unbalanced steady-state components introduce cross-frequency coupling, conventional $2\times2$ impedance scan methods must be extended to identify harmonic transfer function (HTF) impedance. However, the measured phases of frequency-coupling terms depend on the starting time of the fast Fourier transform (FFT) window, potentially introducing phase errors when different time references are used. This paper presents a $dq$-domain measurement method of HTF impedance that explicitly accounts for this time dependence. Phase compensation aligns the measured Fourier coefficients to a common electrical phase reference, correcting the resulting phase discrepancies and enabling consistent impedance reconstruction. Comparisons with analytical models under balanced and unbalanced conditions verify the measurement method, recovering the conventional $2\times2$ impedance and the dominant coupling blocks of a $6\times6$ HTF representation, respectively.

0.34

Internal-Model-Control-Based Virtual Admittance Emulation for Enhanced Grid-Forming Performance

eess.SY ·2026-09-18 ·Ruzica Cvetanovic, Lazar Stojanovic, Paolo Sbabo, Paolo Mattavelli, Massimo Bongiorno
similarity 0.45
Abstract

The large-scale integration of renewable energy into electrical power systems places a growing reliance on grid-forming converters (GFMs) to overcome critical stability and control hurdles. By emulating a slowly varying voltage source behind a tunable resistive?inductive impedance, GFMs enable precise setpoint tracking and vital grid support. In this regard, virtual admittance (VA)-based inner-loop control provides exceptional flexibility in shaping the converter's small-signal immittance at connection terminals, allowing for advanced GFM functionalities. This article addresses a novel internal-model-control-based VA approach, which inherently accounts for the effects of the inner current-control loop and the voltage feedforward. Unlike the state-of-the-art VA control, the proposed VA control ensures that, at frequencies outside the influence of outer loops, the converter's terminal admittance closely matches the target admittance, which is shown to be relevant for stability. It is revealed how, with the state-of-the art VA control, a small-signal instability in the harmonic range may arise if a low-pass filter with a high cut-off frequency is used for the voltage feedforward. However, the proposed VA control ensures stable operation regardless of this cut-off frequency. The methodology is experimentally validated using a laboratory prototype that features three-phase voltage-source converters.

0.21