CS Paper Radar

A Frame-Level View and Image-Quality Annotation Tool for Fetal Echocardiography: Comparison with Spreadsheet Annotation

Mohamed Azzam, Ziyang Xu, Quinlan Couch, Zoe Keese, Andrea Cadlo, Christine Sedze-DeWolf, Micaiah Uhrmacher, Madelyn Graff, Catherine Fox, Lauren Vatter, Paige Jeffryes, Jason Christensen, Neil Hamill, Shibiao Wan, Ling Li, Jieqiong Wang

cs.HC eess.IV ·submitted 2026-11-04 17:07 UTC · v1

Abstract

Objective: To develop the Cardiologist Annotation Tool (CAT) for frame-level cardiac view and image-quality annotation in fetal echocardiography and compare it with spreadsheet-based annotation. Methods: CAT provides cine playback, frame navigation, and keyboard-based labeling without manual frame-range entry. Experts annotated 25 studies using both methods, and spreadsheet annotations were audited for predefined data-entry errors. In a randomized crossover study, six medical students annotated two normal studies, one with each method, against an expert reference. Results: Among 1,746 spreadsheet-annotated files, 6.2% contained major or critical data-entry errors, more frequently in congenital heart disease than normal studies (10.9% vs 3.4%). CAT yielded more annotated view segments per clip (3.6 vs 1.5). Rates of labeled and correctly labeled frames per minute were 1.77 and 1.68 times those with spreadsheets, respectively (both P = 0.031), with gains in all six students. No detectable difference in view-label accuracy was observed. Conclusion: CAT eliminates manual frame-range entry and enables finer-grained, structured annotation of fetal echocardiography, providing a practical approach to preparing datasets for AI research.

Closest papers

Nearest neighbours by meaning across the whole index.

EchoAlign: Echocardiography foundation model with multilevel report alignment

cs.CV ·2026-11-20 ·Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol +4 more
code/data similarity 0.63
Abstract · 33 pages, 3 figures, 6 extended data figures, 4 extended data tables. Code and model weights: https://github.com/BioMedIA-MBZUAI/EchoAlign

Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI foundation models can learn to analyze these studies from clinical reports, reducing annotation burden and supporting clinical interpretation. However, existing models are trained by pairing each video with the full clinical report, including structures and findings its view does not show. This mismatch lets a model associate a finding with incidental or spurious signals rather than its visual evidence, which limits accuracy, anatomical grounding and clinical trust. Here we introduce EchoAlign, a vision-language foundation model developed on 2.87 million echocardiographic videos and images from 159 clinical centers. EchoAlign aligns each cardiac structure, video and study with its report text, and a visibility matrix restricts supervision to the views that actually depict each structure. We compare it with five public foundation models on 0.47 million test videos across ten unseen external datasets from more than 25 clinical centers. EchoAlign achieves the highest mean AUROC of 0.890 (95% CI, 0.881 to 0.897) for classification and the highest mean quadratic weighted kappa of 0.530 (95% CI, 0.511 to 0.544) for severity grading. Across 62 clinical findings, EchoAlign provides one model that detects findings, grades their severity, estimates measurements and segments cardiac structures.

0.26

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.55
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published similarity 0.55
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24

Multimodal Generative AI Assists Comprehensive Echocardiographic Interpretation

cs.CV ·2026-10-23 ·Yi Qin, Marawan Elbatel, Shanshan Song, Taoran Huang, Jiarong Guo +26 more
similarity 0.53
Abstract

Echocardiography is the cornerstone of cardiovascular diagnostics, yet its global utility is constrained by a critical shortage of experienced interpreters. Current artificial intelligence (AI) solutions remain limited, typically operating as opaque "black boxes" or focusing on narrow tasks that fail to capture the holistic, guideline-driven reasoning of a clinician. Here we introduce EchoChat, a generative multimodal vision-language model that performs comprehensive echocardiographic analysis to support clinician interpretation. By emulating the cognitive workflow of a cardiologist, EchoChat integrates vast medical knowledge with a chain-of-thought reasoning mechanism to explicitly ground its conclusions in visual evidence. Trained on echocardiography-instruction pairs from 46,358 examinations, our model establishes a new state-of-the-art across diverse cohorts from six international medical centers. It supports the broadest diagnostic scope of 33 cardiac conditions and findings, including 15 newly added conditions for which it achieves an average F1 of 73.7% across available external evaluations. It surpasses existing best-performing foundation models in cardiac condition recognition (improving average recall by 13.54% on shared tasks) and quantification (average R2 score increase of 0.275 on shared tasks). Furthermore, in a source-blinded echocardiographer reader study, echocardiography reports co-generated with EchoChat were rated higher in diagnostic accuracy and completeness by two senior echocardiographers, and improved diagnostic performance from 72.78% to 82.75% in terms of F1 score over routine-reader only reports. These results demonstrate that integrating clinical reasoning into multimodal AI can democratize specialist expertise and transform the standard of cardiovascular care.

0.24

Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

eess.IV cs.CV ·2026-08-21 ·Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte
benchmark similarity 0.52
Abstract

LGE cardiac MRI is widely used for left atrial fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often, poor quality images used during ablation planning can cause mis-localization of ablation targets, directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00).

0.27

EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan

cs.CV ·2026-10-04 ·Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen +1 more
similarity 0.52
Abstract · 33 pages, 5 figures, including Supplementary Information

Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.

0.19

Towards Whole-Study Screening for Congenital Heart Disease in Fetal Ultrasound Using Multiple Instance Learning

eess.IV cs.CV ·2026-09-25 ·Mohamed Azzam, Ruobing Liu, Esther C. Ugwueke, Ziyang Xu, Shibiao Wan +6 more
similarity 0.52
Abstract

Congenital heart disease (CHD) is the most common birth defect, yet a large fraction of cases remain undetected on prenatal ultrasound, in part because current artificial-intelligence methods assume that the key diagnostic frames have already been isolated from a study, by a clinician or by a view classifier. We remove that assumption and address CHD screening directly at the level of the whole ultrasound study. We propose a two-stage framework that first learns transferable frame representations by self-supervised masked-autoencoder pre-training on unlabeled fetal ultrasound, then identifies cardiac frames with a disease-robust module and aggregates them with a transformer-based multiple instance learning (MIL) model that produces a case-level diagnosis from study-level labels alone. The model further returns its highest-scoring frames for clinician review, and a hierarchical head separates critical from non-critical CHD. On the internal test set of our multi-source development cohort (FUSE), the proposed cardiac-gated MIL model reaches an area under the curve (AUC) of 0.985 with a specificity of 0.990, outperforming the reproduced NATMED ensemble (AUC 0.861, specificity 0.600) and the FetalCLIP foundation model (AUC 0.867, specificity 0.710). On an independent external cohort, all models initially perform near chance, but label-free CORAL adaptation raises the proposed model from an AUC of 0.513 to 0.944, whereas whole-study and view-dependent baselines do not recover. These results indicate that whole-study MIL with disease-robust cardiac-frame identification is an accurate and deployable route to prenatal CHD screening.

0.15

Pos4CHD: A Positive-Free Mask-Guided Counterfactual Synthesis Framework for Fetal Congenital Heart Defect Analysis

cs.CV ·2026-10-22 ·Wenjie Xuan, Yapeng Li, Hang Su, Chen Cheng, Juhua Liu +3 more
code/data similarity 0.52
Abstract · Submitted to IEEE TMI, under review

The scarcity of positive cases remains a major bottleneck in developing automated diagnostic systems for fetal Congenital Heart Defects~(CHDs), particularly for rare subtypes. Although normal cases are accessible with effort, positive cases are hard to collect due to low incidence rates and privacy concerns, causing severe class imbalance or absence of positive training samples. Existing works resort to synthesizing positives with conditional generative models, but they are task-specific and require positive training samples, hindering application for fetal CHDs. To this end, we propose a positive-free mask-guided counterfactual generation framework for fetal echocardiography, namely Pos4CHD, which enables realistic, high-quality synthesis of pseudo-positive samples from semantic masks, with only normal samples at hand. Technically, we first develop FE-Gen, a mask-guided generative model tailored for fetal heart ultrasound synthesis that mitigates histogram drift and enhances image-mask spatial alignment. Building on FE-Gen, Pos4CHD employs a mask-to-image generation paradigm for CHD synthesis. It first manipulates semantic masks to simulate fetal-heart structural anomalies and then renders anatomically consistent images. Extensive experiments on in-house datasets, together with expert evaluations, demonstrate the visual fidelity~($-12.97$ FID) and anatomical consistency~($+3.96\%$ DSC) of synthesized images. Further validations across diverse real-world CHD diagnosis tasks exhibit promising results and consistent increments, including zero-shot classification~(achieving $93.25\%$ ACC on EbA and $72.92\%$ ACC on TAPVC), lesion detection~($+6.95\%$ mAP50 on VSD), and anatomy segmentation~($+10.49\%$ DSC on fetal heart) compared with baselines. Codes and models are publicly available on \href{https://github.com/DREAMXFAR/Pos4CHD}{GitHub}.

0.37