CS Paper Radar

EchoAlign: Echocardiography foundation model with multilevel report alignment

Ahmed Aly, Darya Taratynova, Lotfi Abdelkrim Mecharbat, Roman A. Sandler, Joseph Z. Sokol, Joshua Penn, Klaus H. Maier-Hein, Numan Saeed, Mohammad Yaqub

cs.CV ·submitted 2026-11-20 12:08 UTC · v1
code/data

Abstract

Echocardiography assesses the structure and function of the heart. Cardiologists read each study across several standard views and report the findings visible in those views by cardiac structure. AI foundation models can learn to analyze these studies from clinical reports, reducing annotation burden and supporting clinical interpretation. However, existing models are trained by pairing each video with the full clinical report, including structures and findings its view does not show. This mismatch lets a model associate a finding with incidental or spurious signals rather than its visual evidence, which limits accuracy, anatomical grounding and clinical trust. Here we introduce EchoAlign, a vision-language foundation model developed on 2.87 million echocardiographic videos and images from 159 clinical centers. EchoAlign aligns each cardiac structure, video and study with its report text, and a visibility matrix restricts supervision to the views that actually depict each structure. We compare it with five public foundation models on 0.47 million test videos across ten unseen external datasets from more than 25 clinical centers. EchoAlign achieves the highest mean AUROC of 0.890 (95% CI, 0.881 to 0.897) for classification and the highest mean quadratic weighted kappa of 0.530 (95% CI, 0.511 to 0.544) for severity grading. Across 62 clinical findings, EchoAlign provides one model that detects findings, grades their severity, estimates measurements and segments cardiac structures.

Comment
33 pages, 3 figures, 6 extended data figures, 4 extended data tables. Code and model weights: https://github.com/BioMedIA-MBZUAI/EchoAlign

Closest papers

Nearest neighbours by meaning across the whole index.

Multimodal Generative AI Assists Comprehensive Echocardiographic Interpretation

cs.CV ·2026-10-23 ·Yi Qin, Marawan Elbatel, Shanshan Song, Taoran Huang, Jiarong Guo +26 more
similarity 0.73
Abstract

Echocardiography is the cornerstone of cardiovascular diagnostics, yet its global utility is constrained by a critical shortage of experienced interpreters. Current artificial intelligence (AI) solutions remain limited, typically operating as opaque "black boxes" or focusing on narrow tasks that fail to capture the holistic, guideline-driven reasoning of a clinician. Here we introduce EchoChat, a generative multimodal vision-language model that performs comprehensive echocardiographic analysis to support clinician interpretation. By emulating the cognitive workflow of a cardiologist, EchoChat integrates vast medical knowledge with a chain-of-thought reasoning mechanism to explicitly ground its conclusions in visual evidence. Trained on echocardiography-instruction pairs from 46,358 examinations, our model establishes a new state-of-the-art across diverse cohorts from six international medical centers. It supports the broadest diagnostic scope of 33 cardiac conditions and findings, including 15 newly added conditions for which it achieves an average F1 of 73.7% across available external evaluations. It surpasses existing best-performing foundation models in cardiac condition recognition (improving average recall by 13.54% on shared tasks) and quantification (average R2 score increase of 0.275 on shared tasks). Furthermore, in a source-blinded echocardiographer reader study, echocardiography reports co-generated with EchoChat were rated higher in diagnostic accuracy and completeness by two senior echocardiographers, and improved diagnostic performance from 72.78% to 82.75% in terms of F1 score over routine-reader only reports. These results demonstrate that integrating clinical reasoning into multimodal AI can democratize specialist expertise and transform the standard of cardiovascular care.

0.24

Prompt2Echo (P2Echo): Text-Prompted Multi-View Echocardiography Segmentation with One Model

cs.CV ·2026-11-10 ·Moein Heidari, Alvin Kimbowa, Mahdi Tabatabaei, Afshin Bozorgpour, Sina Ghorbani Kolahi +6 more
code/data similarity 0.72
Abstract · 10 pages, 5 figures, 7 tables

Automated segmentation in multi-view echocardiography is essential for comprehensive cardiac assessment, yet remains challenging due to substantial anatomical and appearance variability across standard acoustic windows. In this paper, we present P2Echo, a unified framework capable of segmenting diverse cardiac structures across multiple standard echocardiographic views using a single model controlled by structured view-aware text prompts. Unlike recent foundation model adaptations that rely on implicit latent priors, P2Echo explicitly conditions the segmentation process via a novel Dynamic Image-Text Alignment (DyITA) module. DyITA integrates a differentiable routing mechanism and token differential operators to dynamically modulate decoder features according to the requested view and target structure. This allows the network to adaptively switch its processing pathways for different views without architectural changes. Extensive experiments on a large-scale internal dataset (seen during training) and held-out evaluation on three external datasets demonstrate that P2Echo matches or exceeds both view-specific specialists and state-of-the-art universal models at a fraction of their computational cost, offering an efficient, controllable solution for multi-plane cardiac analysis. Code is available at: https://github.com/moeinheidari7829/P2Echo.

0.56

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.68
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

AI-Based Multi-View Echocardiographic Image Synthesis using Dynamic Shape Control

cs.CV cs.AI ·2026-11-13 ·João Freitas, Anca Balinisteanu, Ahmed Youssef, Vitor Hugo Pereira, Jan D'hooge +1 more
published similarity 0.66
Abstract · 5 pages, 2 figures, accepted for publication in the Proceedings of the 2026 IEEE International Ultrasonics Symposium (IUS 2026)

Although automated methods have improved echocardiographic workflows, progress remains constrained by the need for large, well-annotated datasets. As the development of clinical databases is often limited by ethical and logistical challenges, synthetic data generation has emerged as a promising alternative. However, existing approaches commonly rely on left ventricle shape-based supervision or are tailored to specific cardiac views, limiting the generation of additional standard and unconventional imaging planes and the preservation of multi-view consistency across cardiac chambers. To address these limitations, we propose a novel framework for shape-controlled synthesis of multi-view echocardiographic sequences. First, multi-view cross-sections are extracted from dynamic whole-heart meshes. Ultrasound-like appearance is then introduced through a two-stage AI-based pipeline. In Stage 1, an unpaired GAN-diffusion model translates these cross-sections into realistic echocardiographic frames. As this translation is performed independently at the frame level, Stage 2 employs masked video reconstruction to improve temporal coherence and cardiac motion. Evaluation demonstrated high frame-level realism for both stages, while the integration of Stage 2 substantially improved video-level motion quality and temporal consistency. Overall, the proposed framework enables the generation of realistic multi-view echocardiographic sequences from diverse cardiac models, providing a scalable source of annotated data for dataset augmentation and the development of multi-view cardiac assessment methods.

0.33

EchoDino: A pediatric foundation model for transferable echocardiographic analysis across the lifespan

cs.CV ·2026-10-04 ·Sheng Cheng, Donnchadh M. O'Sullivan, Daniel J. Penny, Craig G. Rusin, Minh B. Nguyen +1 more
similarity 0.66
Abstract · 33 pages, 5 figures, including Supplementary Information

Echocardiography is the most widely used cardiac imaging modality, yet interpretation demands integrating visual evidence across global anatomy, localized structures and dynamic cardiac motion. Machine-learning models have automated individual tasks, but they are typically built for a single purpose and depend on expensively labeled datasets - a barrier particularly acute in pediatric care, where data are scarce and anatomy changes with age. Here we present EchoDino, a self-supervised foundation model for echocardiography, created by adapting the DINOv3 framework to 3.7 million frames from 1.7 million unlabeled pediatric echocardiography videos. With its encoder frozen, EchoDino produces representations that capture global context, local anatomy, and dense spatial detail. We introduce Motion-biased Entropy Maximization Sampling (MEMS) to select the most informative frames for video-level analysis. Across nine pediatric and adult datasets, EchoDino outperformed strong baseline models, raising view-classification accuracy from 0.609 to 0.889 and the area under the receiver operating characteristic curve for structural-heart-disease detection from 0.811 to 0.872, while also cutting age-estimation error from 3.857 to 1.389 years, achieving the best segmentation accuracy and lowering ejection-fraction errors. By generalizing from label-free pediatric data to adult echocardiography, EchoDino offers a versatile foundation for cardiac image analysis across the lifespan.

0.19

EchoTab: Learning Measurement-Grounded Representations for Echocardiographic Diagnosis through Tabular Reconstruction

cs.LG ·2026-10-09 ·Michelle Espranita Liman, Ioana Ionac, Alexander Müller, Eimo Martens, Daniel Rueckert +1 more
code/data similarity 0.65
Abstract

Diagnostic information in multi-view medical imaging studies, like echocardiography, is distributed across views, each capturing different aspects of cardiac structure and function. In clinical practice, these views are first interpreted through quantitative measurements, which then support specific diagnoses. However, existing echo representation learning methods do not explicitly model measurements as an intermediate representation between views and diagnosis. As a result, individual measurements are not explicitly represented in a form that downstream diagnostic tasks can selectively use, hindering accurate diagnosis. Inspired by this hierarchical clinical workflow, we introduce EchoTab, a measurement-grounded representation learning framework that represents multi-view echocardiography studies using measurement-specific tokens as an intermediate representation between echo views and diagnosis. Each measurement token selectively attends to the views relevant to its estimation and is trained through tabular reconstruction to predict the corresponding measurement value. The resulting tokens form a factorized echo representation, which encode clinically meaningful structural and functional properties and can be selectively used for downstream diagnosis. Unlike the commonly used contrastive approaches, EchoTab does not require negative samples or large batch sizes. Experiments on two datasets demonstrate that EchoTab learns effective measurement-grounded representations that improve diagnosis classification in multi-view echocardiography and its learned attention aligns with established measurement-view relationships used by cardiologists. Our code is accessible at https://github.com/michelleespranita/EchoTab.

0.44

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.64
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence

cs.CV cs.AI ·2026-10-08 ·Yuchen Yang, Xin Wang, Lufan Wang, Yinghong Pan, Yujuan Feng +1 more
publishedbenchmarkcode/data similarity 0.63
Abstract · Accepted to BMVC 2026. Code: https://github.com/NiHaoWoJiaoYYC/CAMEO

Generating ultrasound reports from multiple images requires aggregating clinical evidence across views, yet archived key frames capture only part of the dynamic examination. Raw-report imitation is therefore misaligned with visual supervision: content that is clinically valid for the full examination may be unverifiable from the images available to a model. This gap creates a clinical behavior alignment problem. A model must preserve visible findings, avoid diagnostic reversals and unsupported completion, and not collapse into conservative templates. We propose CAMEO, a Clinically Aware Multi-image Evidence-grounded Orchestration framework for ultrasound report generation. Stage I learns ultrasound visual-language primitives; Stage II performs Cross-View Evidence Grounding by distilling trusted visible report points into multi-image QA and report-style supervision; and Stage III performs Clinically Aware Preference Alignment using clinical-error-oriented preference pairs. From USReport, we construct USReport-Distilled with 17,670 evidence-grounded paired-image training instances and USReport-Pref with 21,869 preference pairs; we additionally use 25,631 PubMedVision-US ultrasound instruction samples for domain adaptation and multi-image instruction tuning. On the primary USReport-Distilled benchmark, CAMEO improves over EchoVLM from 0.25 to 0.40 BLEU-1, 0.28 to 0.45 ROUGE-1, and 0.27 to 0.43 METEOR, while raising ClinicalScore from 55.02 to 74.20. These results underscore the value of evidence-grounded supervision, clinically aware alignment, and clinically structured evaluation for reliable ultrasound report generation.

0.45