CS Paper Radar

Kinematic Total-Body PET Video Reconstruction via Hierarchical List-Mode EM and Validation-Adaptive Space-Time Regularisation

Andrew J. Reader, Gary J. R. Cook, Paul K. Marsden, Sarah-May Gould, Alexander Hammers, Simon R. Cherry

eess.IV ·submitted 2026-11-08 01:09 UTC · v1

Abstract

Kinematic PET is introduced as an imaging task focused on visualisation of early radiotracer delivery and rapid multi-organ motion without gating. The proposed kinematic video reconstruction method uses 33-ms frames (~30 frames per second), initialised with 3D expectation maximisation (EM) time of flight (TOF) list-mode reconstruction, followed by cycles of a 2-stage update. These 2 stages are i) a hierarchical EM (HEM) update using multiple temporal pooling levels, and ii) a validation-adaptive space-time (VAST) regularisation update. HEM combines frame-specific EM corrections with corrections estimated from higher-count temporal blocks, slowing noise amplification for the ultrashort frames. VAST mixes each 3D target patch in a frame with source patches sampled nearby in space and time. It selects the candidate that best matches the mean of the corresponding patches in the two adjacent frames, with the unchanged patch also eligible. Optional temporal block sum correction uses the initial EM temporal sum as a reference to reduce loss of spatial detail. HEM+VAST was evaluated with a dynamic digital phantom, and demonstrated on human FDG data acquired on a Siemens Biograph Vision Quadra (28 - 58 s post-injection). At a background spatial coefficient of variation of 10%, the temporal full width at half maximum of the fastest phantom bolus was 151 ms with HEM+VAST, compared with 86 ms for the ground truth. The video frame rate FDG images reveal vascular and organ detail, radiotracer bolus passage and respiration-related multi-organ motion. Kinematic PET could complement conventional dynamic PET by supporting the development of image-derived physiological biomarkers and motion estimation for quantitative reconstruction. Future work should compare HEM+VAST with prior 4D PET reconstruction methods at the same 33-ms frame duration and matched noise levels.

Comment
10 pages, 11 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.63
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.59
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.24

Anatomical and Physical Supervision for CT-less PET Attenuation Correction: BIC-MAC 2026 Challenge

cs.CV ·2026-08-16 ·Petros Chatzitoulousis, George K. Matsopoulos
similarity 0.59
Abstract · 6 pages, 1 table. Technical report for the BIC-MAC 2026 Challenge

This report describes our submission to the Big Cross-Modal Attenuation Correction (BIC-MAC) 2026 Challenge for CT-less PET attenuation correction through multimodal pseudo-CT synthesis. We build upon a standard nnU-Net architecture and combine anatomical and physical supervision to improve both pseudo-CT quality and downstream PET reconstruction. Anatomical supervision is introduced through a frozen TotalSegmentator feature extractor, anatomy-guided structural constraints and patch sampling, while physical supervision is achieved using a differentiable attenuation correction factor projection loss based on multi-angle attenuation projections. Furthermore, the network is initialized with pretrained weights obtained from training on the SynthRAD Challenge MR-to-CT dataset. Minimal architectural modifications are applied, while performance improvements are pursued across the nnU-Net pipeline, including preprocessing, plans, and supervision design, among other components. Our final submission demonstrates the effectiveness of combining anatomical supervision, attenuation physics, and efficient nnU-Net scaling for CT-less PET attenuation correction.

0.07

Geometry-anchored PET-aware multimodal pseudo-CT synthesis for whole-body attenuation correction: the BIC-MAC Challenge

cs.CV ·2026-08-19 ·Xuan Loc Nguyen, Hoang-Loc Cao, Truong Thanh Hung Nguyen, Phuc Ho, Phuc Truong Loc Nguyen +2 more
published similarity 0.59
Abstract · Challenge paper for the Big Cross-Modal Attenuation Correction (BIC-MAC) Challenge at MICCAI 2026

The BIC-MAC challenge targets whole-body pseudo-CT synthesis from NAC-PET, Dixon MRI, and a 2D topogram for CT-less PET attenuation correction. We propose GeoPACT, a geometry-anchored multimodal framework that uses NAC-PET as the spatial reference and incorporates topogram and MRI features through gated residual fusion. Absolute coordinates and whole-body conditioning support anatomically consistent patch-based prediction. Training combines attenuation-map supervision with a differentiable PET-response surrogate to reduce errors relevant to downstream PET reconstruction. Full-resolution pseudo-CT volumes are generated using sliding-window inference without requiring CT or PET labels at test time.

0.27

Training-Free Motion-Corrected 3D Brain MRI Reconstruction via Event-Guided References

cs.CV ·2026-11-01 ·Wei Jiang, Hongli Chen, Tianyi Ding, Feng Liu, Nan Ye +1 more
code/data similarity 0.58
Abstract

Head motion causes artefacts in 3D brain MRI and can bias structural measurements. Model-based correction alternates between image and motion estimation, but artefacts in the reconstructed reference can reinforce motion errors. Learned priors can reduce these artefacts but require pretraining and may add test-time computation. We propose EventMC (event-guided motion correction), a training-free method for interleaved Cartesian acquisitions. It iteratively detects motion events and estimates motion using reference images reconstructed from stable intervals. It then refines the image and motion from low to high spatial frequencies. In a fair comparison in simulation (same reconstruction), EventMC's motion estimates improve mean PSNR by up to 4.0 dB over those of the learning-based MotionTTT. A single run of EventMC is up to 7.5 times faster than MotionTTT with less than half the GPU memory. On in vivo motion-corrupted scans, EventMC achieves similar mean image quality to MotionTTT without any training. Code is available at https://github.com/bayesbreeze/EventMC.

0.36

Event-Only Wingbeat Counting under Camera Motion: A Controlled MuJoCo Benchmark

cs.CV ·2026-09-27 ·Zhang Nengbo
benchmark similarity 0.58
Abstract · 10 pages, 1 figure, 6 tables. Controlled simulation study with an ideal contrast-event sensor. Follow-up to arXiv:2609.17308 using new event…

Counting completed wingbeats requires identifying individual cycles, including during frequency changes and pauses; estimating a dominant frequency alone is insufficient. Camera motion further mixes target and background brightness changes in event observations. We present a controlled MuJoCo benchmark that separates motion training from event-only image translation compensation. The acquisition contains 324 streams from 24 independent scenes, three flapping geometries, two distances (1.5 and 3.0 m), and static, moderate-motion and stronger-motion views. Fifteen scenes are used for fitting, three for validation and six for held-out testing. A fixed causal temporal convolutional network is evaluated in a matched 2 x 2 ablation with three initialization seeds and compared with ridge, Fourier, autocorrelation and an adapted EEPPR baseline. Under moderate motion, paired motion training reduces count mean absolute error from 31.130 to 3.185 cycles at 1.5 m and from 42.019 to 5.444 at 3.0 m. Adding the tested compensation increases these errors to 4.630 and 10.185, respectively. A Fourier baseline achieves 0.944 cycles at 1.5 m under moderate motion, showing that the neural model is not uniformly best. We report exact-count accuracy and temporally matched cycle F1 alongside count error. These findings support motion-aware training in this small synthetic benchmark, while exposing limits of simple event-background stabilization. They do not establish real-sensor performance, aerodynamic flight, or generalization to unseen vehicle types.

0.20

Multimodal pseudo-CT synthesis for PET attenuation correction using separate modality encoding and topogram conditioning

eess.IV cs.CVphysics.med-ph ·2026-08-21 ·Rory Bell, Artemis Bouzaki, Jiaming Cao, Jasmine Morrison, Chelsea Sargeant
code/data similarity 0.57
Abstract · Technical report for the BIC-MAC 2026 Challenge

We participated in the BIC-MAC Challenge with a multimodal 3D patch-based U-Net for pseudo-CT generation from NAC-PET, MRI, and 2D topograms. By using separate PET and MR encoders, multi-scale feature fusion, and FiLM-based topogram conditioning at the bottleneck, we obtain a model that integrates complementary cross-modal information while reducing reliance on precise voxel-wise correspondence between modalities. Our final submission can be found: https://github.com/rrr-uom-projects/BIC-MAC-MICCAI2026

0.17

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.57
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13