CS Paper Radar

Multi-UTE Myelin Fraction Mapping: Repeatability and Cross-Field-Strength Reproducibility at 1.5T and 3T

Nan Yin, Marco Reisert, Theo Demerath, Shuai Liu, Alexander Rau, Uzay Emir, Horst Urbach, Michael Bock, Ali Caglar Özen

eess.SY physics.med-ph ·submitted 2026-11-11 22:58 UTC · v1

Abstract

Purpose: To evaluate the repeatability and cross-field-strength reproducibility (1.5T vs 3T) of in vivo cerebral myelin fraction (MF) mapping with multi-contrast dual-resolution 3D UTE (multi-UTE), and to compare it with magnetization transfer (MT)-based methods. Methods: MT methods provide an indirect myelin-sensitive measure derived from magnetization exchange between macromolecular and free-water proton pools, whereas multi-UTE targets the ultrashort-T2* signal components. In five healthy volunteers, multi-UTE and MT-based measurements were performed at 1.5T and 3T, and the calculated MF maps were compared with magnetization transfer ratio (MTR) and magnetization transfer saturation (MTsat) maps. Two volunteers underwent repeated multi-UTE measurements within and between days. Field-strength reproducibility and test-retest repeatability were evaluated using linear regression, Bland-Altman analysis, concordance correlation coefficient (CCC), and intraclass correlation coefficient (ICC). Results: Multi-UTE enabled simultaneous acquisition of quantitative and high-resolution structural images at both 1.5T and 3T. MF repeatability was high at 3T (ICC = 0.94-0.96) and more variable at 1.5T (0,64-0.96). Across field strengths, MF and MTsat showed comparable reproducibility (CCC 0.70 vs 0.60) with small median absolute differences (8.8% vs 8.9%). MTsat showed tighter correlation (R2 = 0.77 vs 0.68), while MF showed a wider inter-regional dynamic range. MTR differed strongly between field strengths (CCC = 0.06). Conclusion: Multi-UTE MF, obtained without B1 or T1 mapping and alongside a high-resolution structural image, achieves cross-field reproducibility comparable to, but not exceeding, MTsat. Lower SNR at 1.5T and unmodelled T1 weighting may have contributed to residual field dependence.

Comment
7 Figures, 2 Tables, 7 Supplementary Figures

Closest papers

Nearest neighbours by meaning across the whole index.

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

cs.CV physics.med-phcs.LG ·2026-10-27 ·Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder +3 more
similarity 0.56
Abstract · 38 pages, 24 figures

Macromolecular pool fraction (MPF) is a quantitative imaging biomarker sensitive to myelin integrity and other changes in tissue macromolecular content, but specialized acquisitions and reconstruction methods limit its use in large-scale studies. We present a physics-guided, self-supervised deep learning framework for retrospectively estimating MPF directly from conventional clinical brain MRI ($T_1$-weighted, $T_2$-weighted, and fluid-attenuated inversion recovery [FLAIR]) without paired quantitative reference scans. The framework embeds an analytical two-pool magnetization transfer signal model that related sequence-averaged radiofrequency transmit power to apparent longitudinal relaxation. To accommodate heterogeneous clinical protocols, the network conditions intermediate features on acquisition parameters via adaptive instance normalization. It was trained and evaluated on a multisite, multivendor, multiprotocol dataset of 7,705 MRI sessions (3 T). Across 1,237 test sessions, mean MPF was $0.182 \pm 0.007$ in white matter and $0.144 \pm 0.009$ in gray matter, with limited variation across vendor-by-protocol groups (between-group coefficient of variation: 2.65% and 5.63%, respectively). In 70 sessions with demyelinating-disease labels, MPF was 35.6% lower in segmented lesions than in normal-appearing white matter. MPF maps from two different clinical protocols acquired in a healthy volunteer showed a mean voxel-wise absolute percentage difference of 7.7% and a concordance correlation coefficient of $0.888$, indicating good cross-protocol consistency. These results suggest that magnetization transfer-informed self-supervised learning enables stable MPF mapping from conventional clinical MRI, providing a scalable approach to investigate demyelinating pathology in both existing imaging archives and prospectively acquired conventional clinical scans without dedicated qMT acquisitions.

0.28

Quantitative Assessment of Hemispheric Asymmetry in Alzheimer's Disease and Healthy Brains via QSM-Derived Biomarkers: A Proof of Concept Study

eess.SP ·2026-10-01 ·Sadad Hasan, Prantik Paul, Maruf Ahmed
unusual similarity 0.50
Abstract

Studying brain lateralization and the resulting hemispheric asymmetry has been a topic of interest for many researchers. Very few studies have focused on differences in brain lateralization and hemispheric asymmetry associated with neurodegeneration. Additionally, Quantitative Susceptibility Mapping (QSM) has not been extensively used to investigate these differences. This article aims to study differences in hemispheric asymmetry between healthy and Alzheimer's disease (AD)-affected brains by calculating the Myelin Hemispheric Ratio (MHR) and Oxygen Extraction Fraction Hemispheric Ratio (OEFHR) between the two hemispheres using QSM as an intermediate marker of neurodegeneration. The estimations and corresponding results show marginal yet promising differences between healthy subjects and AD patients. These encouraging initial results emphasize the need to further investigate structural brain asymmetry and its alteration as a potential marker of AD-related neurodegeneration.

0.26

SWIMSS: An Open Multi-Center SwinUNETR Model for Multiple Sclerosis White Matter Lesion Segmentation

eess.IV ·2026-11-17 ·Federico Spagnolo, Po-Jui Lu, Mario Ocampo-Pineda, Lester Melie-Garcia, Esther Ruberte +23 more
code/data similarity 0.48
Abstract

Purpose: To develop and validate SWIMSS (SWInUNETR for Multiple Sclerosis white matter lesion Segmentation), a SwinUNETR-based deep learning (DL) model for reliable automated white matter (WM) lesion segmentation, in a large multicentric cohort of people with multiple sclerosis (pwMS). Methods: A real-world longitudinal dataset of 1,385 pwMS from seven Swiss clinical centers was used to train, validate, and test SWIMSS and two state-of-the-art DL architectures: UNETR and MSSegDiff. Inference results obtained with LST-AI were also compared. Preprocessed magnetization-prepared rapid acquisition gradient echo and fluid-attenuated inversion recovery MRI sequences, acquired with various MR systems and field strengths, served as model inputs. Model performance was evaluated using the Dice similarity coefficient (DSC) with 95% confidence intervals (CI). Results: SWIMSS achieved the highest performance, with a DSC of 81.37 (95% CI: 80.63-82.11), outperforming UNETR (79.06; 95% CI: 78.33-79.79), MSSegDiff (75.70; 95% CI: 74.97-76.43), and LST-AI (63.19; 95% CI: 62.08-64.30). Normalized DSC followed a similar trend, with SWIMSS reaching 84.88. Lesion detection F1 achieved 81.14. Statistical analyses confirmed its superior performance (p < 0.001). Conclusion: SWIMSS achieved state-of-the-art performance for WM lesion segmentation. By making this model publicly available, we enable broader access to high-quality segmentation tools, allowing smaller centers, often lacking large annotated datasets or computational resources, to benefit from a model trained on a diverse, large-scale cohort. This promotes more equitable access to advanced imaging analysis and supports reproducibility and standardization in MS research.

0.22

Interpretable Multimodal MRI-Clinical Fusion for Functional Outcome Prediction After Acute Ischemic Stroke

cs.LG cs.AIcs.CVeess.IV ·2026-11-05 ·Sina Raeisadigh, Henning Müller, Abderrahmane Hedjoudje
similarity 0.45
Abstract · 5 pages, 2 figures, 1 table

This study evaluates the added prognostic value of day-1 multimodal MRI for predicting three-month functional outcome after acute ischemic stroke (AIS). Sixty-six AIS patients with ADC, DWI, FLAIR, and clinical data were analyzed. Three-dimensional pretrained ResNet embeddings were extracted from each MRI modality, reduced using fold-isolated principal component analysis, and combined with structured clinical variables and ADC-derived lesion biomarkers. Linear support vector machines were evaluated using eight-fold stratified group cross-validation across MRI modality combinations. Clinical-only modeling achieved strong performance (AUC = $0.899 \pm 0.151$), while MRI-only models showed limited discrimination (AUC $\approx$ $0.67$-$0.73$). Among multimodal configurations, FLAIR-clinical fusion achieved the highest mean cross-validated performance (AUC = $0.948 \pm 0.061$), followed by ADC-clinical fusion (AUC = $0.941 \pm 0.094$). Full ADC-DWI-FLAIR fusion did not consistently outperform single-modality clinical fusion. Feature-importance analysis identified age, NIHSS subscores, ADC lesion burden, and learned FLAIR representations as key contributors, while qualitative FLAIR activation maps showed responses over lesion-like regions. These findings suggest that compact day-1 FLAIR and ADC representations provide complementary prognostic information beyond clinical variables and support interpretable, data-efficient outcome prediction in AIS.

0.14

Multidimensional Source-Space MEG Representation of Network Imbalance in ADHD

eess.SP ·2026-11-18 ·Xiran Guo, Zhihao Liu, Guanghua Liu
similarity 0.45
Abstract · Submitted to IEEE Journal of Biomedical and Health Informatics (JBHI)

Attention-deficit/hyperactivity disorder (ADHD) is associated with an atypical imbalance between the default mode network (DMN) and task-control systems. However, compressing neural activity into a single macroscopic imbalance measure may obscure individual neurophysiological differences. To address this, we leveraged the source-orientation selectivity and related measurement properties of resting-state magnetoencephalography (MEG) to establish a multidimensional source-space network representation in 21 individuals with ADHD and 21 healthy controls. We defined the macroscopic imbalance in relative Alpha activity between the DMN and task-control systems as the Core, and expanded its constituent information along three dimensions: spatial sources, spectral composition, and temporal network organization: into in-depth measures, assessed for stability, robustness, and complementarity. We found that the ADHD group exhibited a significant Core Alpha imbalance, driven mainly by task-control regions, while the multidimensional expansion revealed complementary ADHD-related neurophysiological information not fully represented by the Core, suggesting that similar macroscopic imbalances may reflect distinct underlying physiological states. Across 40 exploratory within-cohort held-out evaluations with separate development and test subsets, mean ROC-AUC increased from 0.7607 (Core-only) to 0.8995 with multidimensional inputs and to 0.9051 with the final ensemble, and mean accuracy increased from 71.43% to 79.82%. These findings suggest that multidimensional source-space expansion can further clarify the neurophysiological composition of ADHD-related network imbalance and improve individual-level discrimination, offering an interpretable framework potentially applicable to other brain disorders characterized by network imbalance.

0.35

Bidirectional Wireless Communication for Weakly Coupled Implantable Brain-Computer Interfaces

eess.SY ·2026-09-05 ·Shreyas Sen, Baibhab Chatterjee, Gourab Barik, Anirudh Roy
benchmark similarity 0.44
Abstract · 33 pages, 4 figures, 2 Tables

Implantable brain-computer interfaces (BCIs) promise transformative societal impact, from restoring lost motor, sensory, and speech function in patients with paralysis, stroke, sclerosis, and sensory deficits to serving as a high-bandwidth conduit between human cognition and machine intelligence. Realizing these visions requires moving from laboratory prototypes to chronic clinical systems that support thousands to millions of electrodes, several millimeters to centimeters deep beneath the brain surface, under strict heating and size limits. Almost every clinically relevant implant therefore operates in a weakly coupled regime, with coupling coefficients of $10^{-3}$ to $10^{-1}$ across centimetres of lossy tissue. In this regime, the wireless channel sets the limits of power-transfer efficiency, communication bandwidth, and energy per bit. We review the recent progress of bidirectional wireless links across inductive, mid-field, RF, ultrasonic, magnetoelectric, optical, UWB, and electro-quasistatic modalities, and benchmark them against the clinical axes of depth, size, and data rate. Within an approximately 10 mW communication budget set by the approximately $1^\circ$C tissue-heating ceiling, narrowband high-Q links are well suited for power transfer and low-speed data, but at 1-10 nJ/b cannot reach the greater than 10 Mbps to tens of Gbps uplinks that thousand- to million-channel interfaces demand, even with aggressive on-implant compression. This calls for sub-10 pJ/b and ultimately sub-1 pJ/b wireless links, where wideband techniques, such as ultra-wideband (UWB) and brain-channel communication (BCC), are suitable. We close with a quantitative framework for analyzing such wireless links and a co-design roadmap across electromagnetics, circuits, packaging, security, and regulation, toward secure, networked, million-channel brain interfaces.

0.34

Modality Contribution Score - A Per-Patient Framework for Quantifying the Relative Diagnostic Contribution of Structural MRI and Amyloid PET in Alzheimer's Disease

eess.IV cs.AIcs.CVcs.LG ·2026-08-23 ·Dawa Chyophel Lepcha, Aaliya Ali, Sophie A. Martin, Deepika Koundal, Pierrick Coupe +1 more
similarity 0.43
Abstract · 15 pages, 7 figures, Under review

Multimodal neuroimaging combining structural MRI and positron emission tomography (PET) captures complementary structure-function relationships across the Alzheimer's disease (AD) continuum, yet existing artificial intelligence systems produce a single diagnostic label without quantifying which imaging modality drove that decision for a specific patient. We introduce the Modality Contribution Network (MCNet) and the Modality Contribution Score (MCS), the first per-patient attribution framework quantifying the shift in modality dominance from structural atrophy to amyloid and metabolic dysfunction across the cognitively normal to MCI to AD continuum. MCS is normalised to unity per subject via modality ablation (MCS_MRI_i + MCS_PET_i = 1.0 for every subject i), providing an interpretable, clinically actionable score that fluid biomarkers cannot supply. Applied to 327 ADNI-3 participants balanced across cognitively normal, mild cognitive impairment, and AD groups, MCNet achieved competitive three-class staging performance (AUC=0.881). The MCS revealed a statistically significant monotonic gradient (Kruskal-Wallis p<0.0001), with increasing PET dominance from cognitively normal (MCS_PET 0.412+/-0.229) through MCI (0.489+/-0.289) to AD (0.671+/-0.426), validated against amyloid SUVR (r=0.172, p=0.006) and FDG metabolic biomarkers (r=-0.287, p=0.0005) from separate imaging pipelines. External replication in 1,073 independent OASIS-3 subjects confirmed cross-cohort generalisability (H=166.99, p<0.0001, eta^2=0.156). A mechanistic comparison with SHAP demonstrated that ablation-based MCS captures clinically meaningful modality dependence that deviation-based methods cannot. These findings position MCNet as a foundation for personalised imaging decisions, clinical trial stratification, and trustworthy AI in dementia care.

0.32

Susceptibility source separation via Closed-form Alternating Newton-type Optimization

eess.IV ·2026-11-19 ·Ignacio Contreras-Zúñiga, Cristian Tejos, Carlos Milovic
similarity 0.43
Abstract

Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved accuracy and robustness against artifacts in high-susceptibility regions. Finally, an echo-time analysis of the three-pool model shows that source separation is driven by second-order nonlinearities in signal decay and phase evolution rather than first-order bulk estimates.

0.25