CS Paper Radar

Latent resonances in oscillator networks

Junjie Xiao, Renaud Lambiotte, Hiroshi Kori

eess.SY nlin.AOphysics.soc-ph ·submitted 2026-11-13 10:59 UTC · v1
theory

Abstract

In networks of coupled oscillators, from neural circuits to power grids, damping is expected to suppress oscillations because of its dissipativity. Here we show that local damping can, counterintuitively, amplify oscillations along some input-output channels, while the network's global oscillation energy decreases and its spectral properties improve. The amplified oscillation arises from a latent resonance that lies in the spectrum yet barely manifests. The added passive damping reshapes this resonance by mixing it with adjacent eigenmodes. In random power-grid networks, damping can boost weakly responding channels by more than an order of magnitude, while subdominant channels can grow to exceed the originally strongest channel. Damping thus not only suppresses oscillations but also provides a way to redistribute oscillatory energy. For any passive network, the amplified response and its upper bound follow exactly from baseline quantities, offering a principled route for network design and control.

Comment
22 pages, 5 figures, Supplementary Materials included (6 figures, 7 tables)

Closest papers

Nearest neighbours by meaning across the whole index.

Lagrangian and Hamiltonian Neural Networks With a Dissipative System

cs.LG physics.class-ph ·2026-09-25 ·V. Rayamajhi, J. Singal
similarity 0.58
Abstract · 14 Pages, 7 Figures, 2 Tables, in review. Comments welcome

We investigate the applicability of Lagrangian and Hamiltonian Neural Network models to a dissipative system that has explicit time dependence in its Lagrangian, Hamiltonian, and total energy. To do so we consider these neural network models for simulated systems of a harmonic one-dimensional, one-component oscillator with damping, as well as without damping for comparison. We find that both the Lagrangian and Hamiltonian approaches are able to predict the empirical physical behavior of the damped oscillator systems and to effectively ``learn'' to varying degrees the underlying Lagrangians and Hamiltonians, as has previously been shown to be the case with undamped oscillator systems. These investigations elucidate important properties of Lagrangian and Hamiltonian mechanics, including properties that are not manifest when considering systems without explicit time dependence.

0.33

Feasibility of Pareto-Improving Damping Control of Forced Oscillations: The Active-Power Case

eess.SY ·2026-11-13 ·Haozong Wang, Yuru Wu, Yan Wen, Qian Liu, Jiahui Yang +3 more
benchmark similarity 0.56
Abstract

Damping control of a forced oscillation may reduce amplitudes at certain locations while increasing them elsewhere. This paper introduces Pareto improvement as a criterion for assessing such control: at least one nodal oscillation amplitude decreases, while none increases across all other nodes. The analysis considers active-power forcing sources and active-power control injections in connected swing networks with positive inertia and damping. Necessary conditions for Pareto improvement feasibility are derived from the normalized nodal responses. It is proven that for every network with a single oscillation source and a single actuator, at least one positive forcing frequency is shown to preclude Pareto improvement, regardless of the amplitude and phase of the control input. A three-node counterexample shows that this limitation does not persist with multiple actuators. PSS/E simulations of a 6-bus benchmark system and a modified IEEE 39-bus system validated the analysis. These findings suggest the value of assessing control effects across the network and further investigating multi-actuator damping control.

0.39

Source--Grid Coupling in Power System Oscillations: Observational Equivalence, Feedback Detectability, and Modal Interaction

eess.SY eess.SP ·2026-09-17 ·Kai Sun, Bin Wang
similarity 0.55
Abstract · Submitted to IEEE Transactions on Power Systems

The conventional distinction between forced and natural oscillations treats the oscillation source as external to a fixed power-system boundary. This paper develops a coupling-aware dynamical interpretation by explicitly accounting for the directionality of source-grid coupling. It examines when prescribed forcing and a one-way autonomous source are observationally equivalent, and when grid measurements can distinguish the presence of grid-to-source feedback. Matched interface signals yield exact equivalence under the same deterministic grid initial-value problem and measurement map. Bidirectional feedback enables source-grid eigenvalue interaction in the augmented autonomous model, while a reduced two-mode model shows that the interaction depends jointly on loop coupling and complex modal separation. The resulting framework establishes source-grid coupling directionality as a feedback-based dynamical boundary and clarifies when feedback can be inferred from grid-side measurements and why weak feedback may remain unresolved. Simulation studies on a two-area system demonstrate feedback detection within a calibrated source family, while source-model mismatch can be confounded with feedback. A WECC 243-bus system study demonstrates feasibility on a large system and shows that feedback detection need not require exact candidate selection.

0.24

Stabilizing Vector Approximate Message Passing with Circuit-Designed Lag-Lead Damping

cs.IT ·2026-11-06 ·Mohamed Akrout
unusual similarity 0.54
Abstract

Vector approximate message passing (VAMP) often fails to converge on ill-conditioned matrices, and its damping factor is tuned either manually or adaptively. Using the fact that VAMP iterations are the discretization of an electric circuit, we show that the denoiser and the likelihood act as nonlinear resistors, the Onsager correction is a mirror resistor and damping is a lag filter. This circuit gives a closed-form loop gain whose spectrum can predict when VAMP fails. Because a lag filter cannot isolate the oscillating modes, we add a lead capacitor whose design often results in a negative capacitance. Across a wide range of condition numbers, our proposed damping strategy achieves a higher convergence rate than adaptive damping and Anderson acceleration at a lower mean iteration cost. On ill-conditioned multipath channels, across ranks and sparsity levels, it also converges more reliably than existing damping baselines.

0.25

Mitigating Forced Oscillations in Power Systems via Data-Enabled Predictive Control

eess.SY ·2026-08-27 ·Soraya Daabak, Verena Häberle, Gabriela Hug, Gustavo Valverde
similarity 0.52
Abstract

Sustained forced oscillations in power systems, driven by large cyclic loads such as data centers, pose a challenge to conventional power system stabilizers (PSSs), which rely on fixed tuned parameters and limited adaptability. This paper investigates the use of Data-Enabled Predictive Control (DeePC) as a data-driven alternative for damping such oscillations. DeePC constructs control actions directly from measured trajectories without requiring an explicit system model, enabling adaptation to changing operating conditions. We evaluate the performance of DeePC on a multi-machine two-area system subject to forced oscillations and compare it against a conventional PSS. The study examines the impact of different input-output configurations and the role of representative historical data in the Hankel matrix construction. Results show that DeePC can achieve superior damping. However, its effectiveness depends critically on the quality and representativeness of the underlying dataset. These findings highlight the potential of data-driven predictive control to complement or outperform conventional stabilizers in modern power systems with evolving and uncertain dynamics.

0.24

Exact Robust Instability Analysis for Networked Dynamical Systems with Biological Application

eess.SY ·2026-08-19 ·Shinji Hara, Yutaka Hori, Tetsuya Iwasaki, Chung-Yao Kao, Sei Zhen Khong
similarity 0.51
Abstract

This paper investigates robust instability in nominally unstable uncertain networked dynamical systems, where all nominal agents share an identical single-input-single-output (SISO) linear time-invariant (LTI) system and each agent is subject to independent perturbations. This setting is motivated by the problem of sustaining periodic oscillations in nonlinear dynamics, for which exact analysis is generally intractable. We identify three classes of network structures including cyclic and certain rank-deficient networks for which the robust instability problem can be reduced to the analysis of a single representative SISO system. We derive sufficient conditions that exactly characterize the robust instability radius for these network classes. Finally, we demonstrate the practical utility of the proposed results by analyzing oscillatory behavior in a genetic regulatory network.

0.30

Forced Oscillations in Power Systems Induced by Data Centers Hosting AI Workloads

eess.SY ·2026-09-23 ·Jovan Krajacic, Georgia Pierrou, Maitraya Desai, Gabriela Hug, Gustavo Valverde
similarity 0.50
Abstract · Revised and extended version of the manuscript previously posted on TechRxiv: https://www.techrxiv.org/doi/full/10.36227/techrxiv.176127304.…

Power swings in large Data Centers (DTCs) running Artificial Intelligence (AI) workloads can excite poorly damped modes in power systems. The resulting forced oscillations can lead to flicker, equipment disconnection, or blackouts. This paper investigates the risks of such load fluctuations for different system strengths and damping conditions. Using an analytical approach based on transfer functions, we identify critical DTC locations in the power grid at which load fluctuations could induce the largest forced oscillations and further characterize the harmonic spectrum of the resulting system response. Depending on the frequency and magnitude of the DTC load fluctuations, forced oscillations can become unbounded. The underlying instabilities are classified into saddle-node bifurcations of the forced periodic response and impasse-surface encounters, using Floquet multipliers and the minimum singular value of the algebraic Jacobian. Furthermore, the impact of different duty cycles and harmonic components beyond the fundamental oscillation frequency in square-wave load profiles is analyzed. Finally, the interaction of two oscillating DTCs is investigated for different locations and forcing frequencies, considering both synchronized and unsynchronized operation. The findings can help system operators to define new regulations on the maximum load fluctuations permitted for DTC facilities at specific grid locations, without negatively affecting the stability and operation of the system.

0.55

Neuromorphic design of a rhythmic network

eess.SY ·2026-10-29 ·Robin Wroblowski, Rodolphe Sepulchre
unusual similarity 0.50
Abstract · This is an author-created, un-copyedited version of an article submitted for publication in the Journal of Neuromorphic Computing and Engine…

Central Pattern Generators (CPGs) have long inspired the design of rhythms that combine endogenous generation and exogenous interaction. In neurodynamics and engineering studies, CPGs have been primarily analysed and designed as networks of coupled oscillators. In contrast, the present article regards CPGs as networks that propagate events through excitable rather than oscillatory nodes. The proposed event-based perspective reduces the design of network-level rhythmic properties to the tuning of local nodal input-output characteristics. This reduction enables a distributed and robust design methodology: nodes can be tuned independently, they can be heterogeneous, and the global rhythm results from local event propagation rather than from a specific global tuning of the network parameters. The present article builds on previously introduced concepts that parallel existing characterizations of oscillators: the event describing function (eDF), which characterises the propagation delay of a node, and the event phase response curve (ePRC), which characterises the phase sensitivity of a node. Event-based CPGs made of excitable rather than oscillatory nodes emerge as a principled design framework for robust rhythm generation.

0.60