Source--Grid Coupling in Power System Oscillations: Observational Equivalence, Feedback Detectability, and Modal Interaction

Kai Sun, Bin Wang

eess.SY eess.SP ·submitted 2026-09-17 18:01 UTC · v1

Abstract

The conventional distinction between forced and natural oscillations treats the oscillation source as external to a fixed power-system boundary. This paper develops a coupling-aware dynamical interpretation by explicitly accounting for the directionality of source-grid coupling. It examines when prescribed forcing and a one-way autonomous source are observationally equivalent, and when grid measurements can distinguish the presence of grid-to-source feedback. Matched interface signals yield exact equivalence under the same deterministic grid initial-value problem and measurement map. Bidirectional feedback enables source-grid eigenvalue interaction in the augmented autonomous model, while a reduced two-mode model shows that the interaction depends jointly on loop coupling and complex modal separation. The resulting framework establishes source-grid coupling directionality as a feedback-based dynamical boundary and clarifies when feedback can be inferred from grid-side measurements and why weak feedback may remain unresolved. Simulation studies on a two-area system demonstrate feedback detection within a calibrated source family, while source-model mismatch can be confounded with feedback. A WECC 243-bus system study demonstrates feasibility on a large system and shows that feedback detection need not require exact candidate selection.

Comment
Submitted to IEEE Transactions on Power Systems

Closest papers

Nearest neighbours by meaning across the whole index.

Stability Analysis in IBR-Dominated Grids: Model-Based and Data-Driven Methodologies

eess.SY ·2026-10-15 ·Federico Cecati, Yang Wu, Florian Dörfler, Marco Liserre, Xiongfei Wang +1 more
similarity 0.60
Abstract · Submitted to IEEE Transactions on Power Electronics

Stability issues in converter-dominated grids have a multifold nature, where static, small-signal and large-signal phenomena can influence each other. Capturing the interplay among these different stability aspects requires a rethinking of conventional modeling and analysis tools for power systems. As a further complication, Intellectual Property protection among manufacturers and system operators makes detailed converters and grid models unattainable. This motivates the use of data-driven approaches for stability analysis and control, nevertheless achieving an insightful representation of static, small-signal and large-signal phenomena from data still leaves many open questions. This paper discusses model-based and data-driven methodologies for stability analysis of converter-dominated grids. The instability mechanisms of static, small-signal and large-signal phenomena are conceptually explained, and the capability of different modeling and analysis tools to investigate them is examined. The effectiveness of data-driven methodologies to analyze instability phenomena in their multifold nature is debated, and the challenges on data completeness, model generalization under untrained conditions, physical interpretability, and uncertainty awareness are discussed.

0.16

Identifiability Limits of Forced Oscillation Sources in Power Systems

eess.SY eess.SPmath.DS ·2026-09-30 ·Kai Sun
similarity 0.59
Abstract

Whether a forced-oscillation source can be uniquely localized depends jointly on the available measurements and the candidate intervention dictionary. This paper considers a single unknown constant-amplitude sinusoid acting through one of physical intervention channels. Because its amplitude and phase are unknown, each candidate harmonic response is observable only up to a nonzero complex scalar and therefore defines a projective ray in measurement space. A necessary-and-sufficient condition is derived for exact localization, together with a weighted nearest-ray locator and a deterministic recovery bound based on projective separation. The paper proposes a framework distinguishing four mechanisms of source localization failure: mechanism mismatch, feature-projection loss, structural nonidentifiability, and poor conditioning or model error. Numerical studies on the Kundur two-area system illustrate well-separated recovery, mechanism-dependent terminal decisions, measurement-induced ambiguity, and the sensitivity of nearly collinear signatures to model perturbations. Then, IEEE--NASPI Contest models are used to further examine broad candidate dictionaries, terminal-feature source coverage, and ambiguity removal through measurement augmentation. The results show that correctly locating the source bus does not by itself establish unique identification of the internal forcing channel or robustness to measurement and model uncertainty.

0.24

Data Center Oscillation Isolation and Grid Support: Fundamental Limits and Source-Selective Control

eess.SY math.DS ·2026-10-19 ·Cheng Feng
similarity 0.58
Abstract

The grid integration of large data centers poses a growing power-system stability challenge. Rapidly varying computing demand can induce oscillations, while the facilities must provide a prescribed response to grid disturbances. Existing controls address load fluctuations and grid support but do not establish their jointly achievable performance. This paper derives fundamental limits and develops a source-selective controller for simultaneous oscillation isolation and grid support. A coupled closed-loop model gives a condition for distinguishing disturbance sources and reveals a direct isolation-support conflict under grid-import-power feedback alone; additional electrical measurements can remove this pointwise conflict but leave a conditional cross-frequency sensitivity limit. Guided by these limits, we design a local residual-feedback storage controller through convex frequency-domain optimization with stability, isolation, and grid-response constraints across operating points. Tests on a single-generator interconnection and a modified nine-bus network show stronger oscillation isolation than equal-order optimized comparators while meeting the prescribed grid response across operating points.

0.22

Compositional Data-Driven Small-Signal Stability Assessment of Power Systems via Output Differential Passivity

eess.SY ·2026-11-16 ·Peng Yang, Xiaohui Zhang, Xi Ru, Feng Liu
similarity 0.56
Abstract · 14 pages

This paper proposes a compositional data-driven small-signal stability assessment framework for interconnected power systems based on output differential passivity (ODP). Without requiring explicit device models, local ODP matrices and scalar indices are estimated directly from measurement trajectories. When internal states are available, trajectory-based linear matrix inequalities (LMIs) are constructed from input-state measurements to estimate the local ODP matrices and scalar indices. When internal states are unavailable, an extended-state representation is constructed from input-output measurements, enabling the same assessment using only external signals. The estimated ODP matrices are combined with the network coupling matrix for compositional assessment of power system stability, while their scalar indices enable decentralized assessment. To address the computational and numerical challenges of trajectory-based LMIs, we introduce right-inverse whitening (RIW) to remove redundant behavioral coordinates and improve computational efficiency, and apply instrumental-variable (IV) preprocessing to alleviate numerical ill-conditioning and mitigate noise effects. Case studies on a modified IEEE 39-bus power system show that ambient measurements satisfy the required informativity conditions and that both formulations yield estimates close to model-based references under the tested noise levels. The reusable local ODP estimates also enable modular stability reassessment after controller updates.

0.30

Spatial Differences Analysis of Nodal Frequency Considering Frequency-Voltage Coupling

eess.SY ·2026-11-04 ·Xiaodan Li, Donghai Zhu, Zining Liu, Zhu Guo, Jiabing Hu +1 more
similarity 0.56
Abstract

The rising penetration of inverter-based resources (IBRs) brings rich control dynamics that can amplify spatial differences in nodal frequency through frequency-voltage (F-V) coupling. Existing analyses often neglect voltage dynamics or only examine the aggregate frequency, leading to overoptimistic evaluation of frequency security. To address these drawbacks, this paper develops a unified model of synchronous generators (SGs), grid-following (GFL)-IBRs, and grid-forming (GFM)-IBRs based on the magnitude and phase dynamics of equivalent internal electromotive force (EMF). Integrating these source models with network equations yields a sparse implicit closed-loop model, which fully captures the device-network F-V coupling without transfer-matrix inversion. Then, the obtained nodal responses are decomposed into common and differential modes. Using this decomposition, coupling indices and pole-residue analysis reveal how F-V coupling can amplify spatial differences in nodal frequency and how source configuration and parameters modify this effect. Finally, case studies on the modified IEEE 39-bus and 118-bus test systems validate the proposed model and demonstrate its computational efficiency.

0.19

Enhancing Transient Stability of VSG-Controlled Converters Under Grid Frequency Disturbances

eess.SY ·2026-11-13 ·B. Li, Y. Zhang, X. Wang, S. Yang, Z. Hao +1 more
similarity 0.55
Abstract

Strong damping feedback can substantially improve the transient synchronization stability of renewable energy converters employing virtual synchronous generator (VSG) control. However, conventional damping feedback uses the nominal frequency as its reference. When the frequency of a weak grid deviates from nominal, strong damping tends to keep the VSG frequency near nominal. This can sustain a frequency difference between the VSG and the grid and compromise transient synchronization. To address this problem, this paper proposes a complex-frequency-based method to estimate the grid reference frequency from local terminal measurements. The estimated frequency replaces the nominal reference in the VSG synchronization loop, so that damping acts on the frequency difference between the VSG and the real grid. Controller hardware-in-the-loop tests validate the effectiveness of the proposed method under grid frequency disturbances and its robustness to grid parameter uncertainty and adverse grid conditions.

0.26

Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation Mitigation

eess.SY ·2026-11-04 ·Quang Manh Hoang, Sina Mohammadi, Phi Long Nguyen, Wencong Su, Van-Hai Bui
similarity 0.55
Abstract · Manuscript is submitted to PESGM2027

Oscillatory power components in AI data-center demand can produce large frequency deviations when they coincide with vulnerable grid modes. Mode-aware hybrid energy storage systems (HESSs) can selectively suppress these components, but their effectiveness degrades when the grid mode changes while the control target remains fixed. This paper proposes a closed-loop grid-mode-adaptive HESS control framework that integrates measurement-based modal identification with mode-selective control. A sliding-window N4SID estimator identifies the local grid dynamics from grid-side power and frequency measurements, and the resulting natural-frequency estimate is used to retune the modal suppression branch assigned to the supercapacitor. The framework is evaluated under a grid-mode shift from 0.50 to 1.35Hz while maintaining equal physical damping and approximately equal load excitation at both frequencies. Compared with the fixed-target controller, the adaptive method reduces the post-change grid-side modal power component from 8.78 to 2.02MW, corresponding to a 76.94% reduction, and substantially lowers the resulting frequency deviation.

0.21

DC Voltage Control Dominated Oscillations in Electromechanical Frequency Range - Insights from Synchronous Coefficient Reduction Effect of IBR Plants and Network Interactions

eess.SY ·2026-11-09 ·Qiang Fu, Siqi Bu
top venue similarity 0.55
Abstract

Large-scale integration of inverter-based resources (IBRs) is widely known to cause subsynchronous oscillations. This paper investigates a distinct class of oscillations that occur in the electromechanical frequency range (EFR), referred to as EFOs, and are dominated by the DC voltage control (DVC) loops of grid-following IBRs rather than synchronous generator-like controls or phase-locked loops (PLLs). Although open-loop oscillation modes of DVC loops are subsynchronous, the corresponding closed-loop dominant oscillation mode related to DVC can shift downward into the EFR without retuning the control parameters. This frequency shift is caused by network-mediated interactions among the IBRs, which introduce a negative synchronous coefficient into the DVC oscillation loop. This synchronous coefficient reduction effect (SCRE) becomes stronger as the IBR plant scale increases and/or as the minimum eigenvalue of the network admittance matrix decreases. Furthermore, a complex vector-based stability analysis method is proposed, and a stability criterion for DVC-EFOs is derived. Finally, the analytical conclusions are validated using a practical power system configuration implemented in Simulink. The SCRE differs from traditional explanations, in which the open-loop oscillation modes are already located in the EFR, and provides new insight into DVC-dominated oscillations in the EFR for integration of IBR plants.

0.42