CS Paper Radar

Identifiability Limits of Forced Oscillation Sources in Power Systems

Kai Sun

eess.SY eess.SPmath.DS ·submitted 2026-09-30 01:46 UTC · v1

Abstract

Whether a forced-oscillation source can be uniquely localized depends jointly on the available measurements and the candidate intervention dictionary. This paper considers a single unknown constant-amplitude sinusoid acting through one of physical intervention channels. Because its amplitude and phase are unknown, each candidate harmonic response is observable only up to a nonzero complex scalar and therefore defines a projective ray in measurement space. A necessary-and-sufficient condition is derived for exact localization, together with a weighted nearest-ray locator and a deterministic recovery bound based on projective separation. The paper proposes a framework distinguishing four mechanisms of source localization failure: mechanism mismatch, feature-projection loss, structural nonidentifiability, and poor conditioning or model error. Numerical studies on the Kundur two-area system illustrate well-separated recovery, mechanism-dependent terminal decisions, measurement-induced ambiguity, and the sensitivity of nearly collinear signatures to model perturbations. Then, IEEE--NASPI Contest models are used to further examine broad candidate dictionaries, terminal-feature source coverage, and ambiguity removal through measurement augmentation. The results show that correctly locating the source bus does not by itself establish unique identification of the internal forcing channel or robustness to measurement and model uncertainty.

Closest papers

Nearest neighbours by meaning across the whole index.

Source--Grid Coupling in Power System Oscillations: Observational Equivalence, Feedback Detectability, and Modal Interaction

eess.SY eess.SP ·2026-09-17 ·Kai Sun, Bin Wang
similarity 0.59
Abstract · Submitted to IEEE Transactions on Power Systems

The conventional distinction between forced and natural oscillations treats the oscillation source as external to a fixed power-system boundary. This paper develops a coupling-aware dynamical interpretation by explicitly accounting for the directionality of source-grid coupling. It examines when prescribed forcing and a one-way autonomous source are observationally equivalent, and when grid measurements can distinguish the presence of grid-to-source feedback. Matched interface signals yield exact equivalence under the same deterministic grid initial-value problem and measurement map. Bidirectional feedback enables source-grid eigenvalue interaction in the augmented autonomous model, while a reduced two-mode model shows that the interaction depends jointly on loop coupling and complex modal separation. The resulting framework establishes source-grid coupling directionality as a feedback-based dynamical boundary and clarifies when feedback can be inferred from grid-side measurements and why weak feedback may remain unresolved. Simulation studies on a two-area system demonstrate feedback detection within a calibrated source family, while source-model mismatch can be confounded with feedback. A WECC 243-bus system study demonstrates feasibility on a large system and shows that feedback detection need not require exact candidate selection.

0.24

Locating Power System Oscillation Sources by Extracting Interharmonics from Synchrophasor Data

eess.SY ·2026-09-03 ·Sophia Xu, Wilsun Xu
similarity 0.53
Abstract · 6 pages and 13 figures

Recent studies have shown that oscillating phasors arise from beating waves caused by interharmonics. This finding has led to an interharmonic-based oscillation source-location method. But waveform data needed for the method are less available than PMU synchrophasor data. This paper investigates whether interharmonics can be extracted directly from phasor data for similar applications. The results show that, for certain oscillation phenomena, phasor data can support interharmonic extraction and oscillation source location. Sensitivity studies have identified the requirements, and a cloud-based software tool is developed for PMU-based source location.

0.28

Causal Discovery for Resiliency-Prioritized Transmission Expansion Planning in Power Systems with Grid-Forming Inverter-Based Resources

eess.SY ·2026-11-15 ·Roy McCann, Mustafa Mhawesh, Sandra Canas Rivera
benchmark similarity 0.48
Abstract

Transmission planners at regional transmission organizations (RTOs), independent system operators (ISOs), and NERC-registered entities have limited analytical resources for exploring expansion options that improve resiliency for withstanding and recovering from fault conditions in electric power systems that are dominated by grid-forming (GFM) and grid-following (GFL) inverter-based resources (IBRs). Conventional existing TPL-001 contingency analysis will assess if a performance benchmark is violated. However, it will not identify which dynamic states and inputs caused the violation, nor how much a protective action will avoid propagation into a cascading outage. This paper proposes an analytical method that combines time-series causal discovery using the Peter and Clark Momentary Conditional Independence (PCMCI) algorithm with right/left eigenvector participation-factor analysis of validated small-signal state-space models. Synthetic data are generated from linearized models derived from substation phasor measurement unit (PMU) data. This includes node-breaker topologies under alternative transmission switching configurations. GFM and GFL inverter controls including phase-locked loops (PLLs) and fault ride-through logic. A planning index referred to as the Resiliency Causal Contribution Index (RCCI) is defined that weights PCMCI-derived causal effects on a TPL benchmark quantity by modal participation. The planning procedure iterates contingency categories, measures margins to RTO/ISO benchmarks for transient voltage recovery, oscillatory damping, inverter ride-through, and TPL-008-1 extreme temperature. The process infers automatic protective actions and repeats until a cascade is ruled out or confirmed. A simplified case study illustrates the entire process for considering the options in transmission expansion planning.

0.33

Frequency-Frame Covariance for Reactive-Power Scalarization

eess.SP eess.SYmath-ph ·2026-11-04 ·Kai Sun
similarity 0.47
Abstract

Measured voltage and current waveforms may be represented in a reference frame whose frequency differs from the physical fundamental frequency. Reactive-power readouts calculated from such frequency-shifted coordinates may change if their readout operators are not transformed consistently. This paper presents a frequency-frame covariance formulation for finite-spectrum, zero-mean periodic waveforms with complete harmonic information over one physical period. A necessary and sufficient covariance condition is derived, requiring the readout operator to transform consistently with the waveform representation. Consequently, frequency-dependent harmonic weights must be evaluated at physical harmonic orders rather than relative frame labels. In particular, the derivative/Iliovici readout equals a relative-derivative contribution plus an explicit reference contribution. The formulation also separates readout-operator errors from errors caused by changes in the physical components retained by waveform projections. Three analytical cases illustrate conditional carrier recovery for a memoryless resistor, physical-frequency weighting at relative zero in an RLC branch, and the possibility that an exact reactive-power scalar can coexist with a substantial waveform error after projection. The scope is deterministic calculation consistency in frequency-shifted coordinates rather than instrument measurement uncertainty.

0.13

Scalable Reservoir Computing for Disturbance Localization and Identification in Power Grids

eess.SY ·2026-10-23 ·Erin Obermayer, Amir Sajadi, Bri-Mathias Hodge, Juan G. Restrepo
similarity 0.47
Abstract · 11 pages, 9 figures, submitted to IEEE: transactions on power systems

In this paper, we present a novel method for the localization and temporal waveform reconstruction of disturbances in complex power grids using observations of system state variables. Although various methods exist for detecting these events, accurately identifying and responding to them remains a significant challenge due to the grid's size, speed, complexity, and inherently dynamic behavior. We formulate a method for disturbance localization and reconstruction based on reservoir computing, a recurrent neural network architecture. We show that our method is able to recover the time dependence of previously unobserved disturbances, is robust to missing information, and can operate online. The approach requires only observed system data and knowledge of the network topology, without requiring a physical model of the system dynamics, and can recover simultaneous disturbances occurring at multiple locations. We implement a scalable parallelized reservoir architecture and demonstrate our algorithm on test IEEE cases and a reduced WECC system.

0.26

Observable Spectral Framework for Noisy Amplitude Amplification: Stopping Stability and Correction

cs.ET quant-ph ·2026-11-16 ·Ge Zhong, Charith Jayasekara, Nisal De Silva, Muhammad Usman, Muhammad Aamir Cheema +1 more
similarity 0.47
Abstract · 28 pages, 5 figures, 4 tables; includes 38-page supplementary material (10 figures). Submitted to EPJ Quantum Technology

Stopping rules for noisy amplitude amplification often rely on channel-specific success-probability formulas, limiting their transfer across noise mechanisms. We develop an observable spectral framework for stationary noisy standard amplitude amplification under explicit leading-mode, spectral-separation, and residual-control conditions. Within this class, the first amplification lobe has a damped-oscillatory leading component and a bounded non-leading contribution. We derive how frequency shift, damping, and observable phase offset displace the leading peak, and establish sampled-gap criteria for retaining the ideal integer stopping depth, certifying recalibration, or selecting a robust candidate window. In single-target Grover search, frequency and damping errors have stopping-coordinate sensitivities proportional to the search-space size, whereas phase offsets scale with its square root; residual modes can independently reverse the ordering of neighbouring depths. Analytical constructions, circuit simulations, finite-shot inference, and calibration-derived device-like trajectories examine these predictions and their operational limits. For a 64-element search, an a posteriori sampled-set check selects depth five over six, with success probability increasing from 0.595 to 0.626. The resulting theory links observable spectral dynamics to conditional integer stopping guarantees without requiring a separate microscopic channel solution.

0.34

Grid-Aware Assessment of Forced Oscillations from Spatially Distributed Large Loads

eess.SY ·2026-11-17 ·Min-Seung Ko, Hao Zhu
similarity 0.47
Abstract

This paper develops a unified analytical framework for assessing forced oscillations induced by spatially distributed large-load fluctuations to determine their grid-aware fluctuation magnitudes. Emerging computational loads, such as hyperscale datacenters, present cyclic power variations with dynamic impacts depending on the waveform characteristics, forcing frequency, and source location. Our grid-aware framework represents these fluctuations using deterministic harmonic and probabilistic spectral models, and analyzes the resulting bus-wise frequency deviations based on a generic grid frequency-response model. Deterministic, risk-aware, and band-based probabilistic severity measures are further developed to obtain admissible fluctuation limits under different assumptions on frequency and phase uncertainty. We also formulate a security-constrained (SC) optimization of locational fluctuation magnitudes among existing large loads, accounting for their aggregated frequency deviation level. Case studies on the IEEE 39-bus and 14-generator Australian systems validate the proposed severity measures and admissible limit analysis. The SC optimization results further show that distributing a given amount of aggregate fluctuation toward dynamically less sensitive locations can substantially reduce system-wide oscillation severity.

0.34

Fisher Information and the Minimum Mean-Square Error for Locating Closely Spaced Point Sources

cs.IT ·2026-10-23 ·Chuling Wen, Jian Lu, Qingtang Jiang, Charles K. Chui
theory similarity 0.46
Abstract

We determine the optimal average error of locating closely spaced sources from noisy superpositions of a known smooth response with unknown complex coefficients. Relative phases control how changes in one location can be offset by the other unknowns, so local Fisher information alone does not determine the attainable error. For every fixed number $K\ge2$ of sources with independent uniform phases, we prove matching Bayes risk bounds jointly in separation and noise, for all sufficiently small separations and all noise levels. Odd source counts have two risk regimes; even counts have an intermediate regime in which mean squared error is linear in the noise standard deviation. A projected least-squares estimator attains these orders without knowing the phases or the prior density. Bounded nonuniform phase laws preserve the orders under stated support conditions, whereas priors concentrated near poorly identified configurations can change the exponents. A common finite comparison yields both a global inverse bound and paths controlled by the original prior. These give sufficient conditions under which the risk has the order of the pointwise capped Cramér--Rao bound, and a lower-tail calculation explains the power and logarithmic regimes. We also give conditional guarantees when the cluster center, separation, and source count are unknown, with an additional low-noise requirement for count selection. A calibrated covariance factor model illustrates the same criterion beyond source localization.

0.26