CS Paper Radar

Information about Optic Nerve Head Biomechanics is Already Coded in Your Clinical Charts and Can be Used to Predict Glaucoma Progression

Yibo Chen, Patipol Tiyajamorn, Charis Y. N. Chiang, Deepta Ghate, Thanadet Chuangsuwanich, Michaël J. A. Girard

eess.IV ·submitted 2026-11-11 20:51 UTC · v1
unusual

Abstract

Glaucoma patients routinely undergo optical coherence tomography (OCT) imaging and intraocular pressure (IOP) assessment as part of standard care. Because IOP typically differs across visits, it is possible to map visit-to-visit ONH strains by registering OCT volumes acquired under different IOPs. These strains reflect ONH elasticity and, over longer intervals, also capture growth and remodeling of the ONH. In this study, we evaluated whether such visit-to-visit ONH strain signatures could serve as predictors of glaucoma progression. We retrospectively analyzed 525 eyes from 430 glaucoma patients (238 fast and 287 slow progressors), defining fast progression by a visual field index slope of -1.5% per year or worse. 3D strain maps were derived from baseline and follow-up OCT scans using AI. Predictions using T=1 to T=4 follow-up visits were evaluated by five-fold cross-validation in a long-term cohort (T=1: 1.30 years; T=4: 5.26 years) and short-term testing (T=1: 0.46 years; T=4: 1.25 years). Overall, IOP differed between paired visits in 92% of cases. Long-term T=1 prediction achieved an area under the receiver operating characteristic curve (AUC) of 0.74 and accuracy of 0.72. A single short-term follow-up (T=1) yielded an AUC of 0.75 and accuracy of 0.71; four follow-ups yielded an AUC of 0.87 and accuracy of 0.82. SHapley Additive exPlanations (SHAP) identified neuroretinal rim compression and prelaminar elongation associated with fast progression, with substantial inter-eye variability. Overall, visit-to-visit ONH strains derived from routine OCT predicted glaucoma progression after a single follow-up visit at a mean interval of 0.46 years. These findings suggest that short-term OCT/IOP assessments could provide valuable insights into ONH biomechanics, identify eyes at risk of rapid progression, and reveal distinct strain signatures associated with disease progression.

Comment
43 pages, 6 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

cs.CV cs.AI ·2026-09-22 ·Charis Y. N. Chiang, Tarela Sarimiye, Adeyinka Ashaye, Martin Buist, Michael A. Hauser +2 more
similarity 0.57
Abstract · 31 pages, 2 Tables, 5 Figures, 1 Supplementary Material

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

0.32

Deep learning of longitudinal visual fields predicts glaucoma progression rate and identifies fast progressors

cs.CV cs.AI ·2026-09-24 ·Taiabur Rahman, Siddiqur Rahman, Muhammad Moniruzzaman, Ummay Kawsar, Sayedatunnessa Ratna +5 more
hot direction similarity 0.55
Abstract

Glaucoma is the leading cause of irreversible blindness, and timely identification of fast progressors is essential to prevent disability. Current practice estimates progression by ordinary least-squares regression of mean deviation (MD) on time, requiring 6--10 visual field (VF) tests over several years to obtain a reliable slope. We present GLAM (Glaucoma Longitudinal Analysis Model), a deep learning framework that ingests longitudinal Humphrey 24-2 total deviation sequences with five clinical features and predicts MD and visual field index progression rates using attention-based fusion and aleatoric uncertainty. On the open-access University of Washington Humphrey Visual Field dataset (4,276 patient-eyes), GLAM achieved an MD-rate mean absolute error of 0.139 dB yr$^{-1}$ ($R^2 = 0.927$; 73.5% reduction over a ridge baseline) and an AUC of 0.990 for fast-progressor detection. VF-only deep learning can match multimodal pipelines for progression prognostication using routinely collected perimetry alone.

0.34

Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study

cs.CV cs.AI ·2026-09-24 ·Raghavan Lavanya, Yangqin Feng, Ten Cheer Quek, Quan V. Hoang, Linda Yi-Chieh Poon +34 more
similarity 0.54
Abstract

Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.

0.28

Auto-GlaKG: Automated Biomarker Reasoning for Explainable Glaucoma Detection

cs.CV cs.AI ·2026-11-08 ·Cheng Huang, Zeyu Han, Yian Hu, Yaopeng Ding, Jingxi Qiu +1 more
similarity 0.53
Abstract

Interpretable glaucoma detection requires a transparent connection between fundus images, clinically meaningful biomarkers, and diagnostic predictions. Knowledge graph (KG) reasoning provides this structure, but performance measured using annotated biomarkers does not establish performance when only images are available. We present Auto-GlaKG, an automated framework that combines image-based biomarker prediction with fixed clinical-prior rules. A ResNet50 network predicts the cup-to-disc ratio (CDR) and six morphological signs using biomarker supervision, and a KG reasoner aggregates their signed rule contributions into a glaucoma score. On 689 fundus images evaluated using stratified, group-aware five-fold cross-validation, Auto-GlaKG achieves a pooled area under the receiver operating characteristic curve (AUC) of 0.951 (95\% confidence interval: 0.931--0.969), with sensitivity of 0.970 and specificity of 0.779. The matched image classifier also achieves an AUC of 0.951, while the rule stage adds 0.2~ms per image. Replacing predicted CDR with its annotation increases fold-mean AUC from 0.953 to 0.995. The framework provides an explicit rule-level account of image-based predictions and identifies CDR estimation as a priority for validation using independently measured biomarkers.

0.20

Optic Disc Segmentation in Fundus Images: From Classical Image Processing and Deformable Models to Modern AI

eess.IV cs.CV ·2026-08-18 ·Buket D. Barkana
similarity 0.51
Abstract

Accurate localization and segmentation of the optic disc (OD) are important for retinal image analysis and glaucoma assessment, yet remain challenging due to variations in illumination, pathology, vascular interference, and poorly defined boundaries. This structured methodological review examines the evolution of OD segmentation from classical image-processing and deformable models to contemporary artificial intelligence (AI)-based approaches. A structured literature search and study-selection process was used to identify representative studies spanning major methodological developments. The review first summarizes commonly used fundus-image datasets, then organizes classical methods by principal mechanisms, including intensity and thresholding, histogram and entropy analysis, morphology, geometric and Hough-transform methods, filtering and feature operators, texture- and region-based approaches, and active-contour and level-set models. This paper pays particular attention to the assumptions, strengths, limitations, and complementary roles of these methods in OD localization and boundary delineation. Representative AI approaches are subsequently examined to illustrate the transition from handcrafted features and explicitly defined priors to learned representations, Transformer-based segmentation, boundary- and shape-aware learning, promptable segmentation, and retinal foundation models. Across these methodological generations, several core segmentation principles persist, including region-of-interest localization, multiscale representation, geometric and anatomical constraints, and boundary regularization, although their implementation has shifted from predefined operators to learned modules, losses, prompts, and pretrained representations. The review further identifies boundary ambiguity, anatomical variability, domain shift, and cross-dataset generalization as continuing challenges.

0.27

GlaucomaMarker - Biomarker-Grounded Glaucoma Vision-Language Model

cs.CV ·2026-11-20 ·Ahammed Sakir Nabil, Sadia Siraz, Nikita Chincholkar, Atalie C. Thompson, Jason Xiao +3 more
similarity 0.51
Abstract

Glaucoma is a leading cause of irreversible blindness. In the current clinical setting, glaucoma diagnosis is generally conducted by assessing optic disc cupping and asymmetry. Vision-language models (VLMs) have been utilized in recent years for glaucoma, mostly trained on fixed templates or AI-generated captions, as no public text describes the biomarkers. Our proposed framework, GlaucomaMarker, hypothesizes that retinal structural biomarkers can ground glaucoma-based VLMs. It converts public segmentation masks into sentences describing eleven biomarkers, to teach retinal foundation models to read them. We applied this framework to RETFound (GlaucomaMarker-R) and FLAIR (GlaucomaMarker-F), training on 9,778 images that yielded 45,190 image-text pairs. On a real-world clinical cohort, GlaucomaMarker-F detects glaucoma with an AUROC of 0.905, against 0.848 for FLAIR, and both read the biomarkers where baselines stay near random guessing. Since the biomarker text is computed from existing masks, it comes at no extra cost.

0.13

Longitudinal Retinal Vascular Remodeling in Myopic Children Treated with Orthokeratology or Defocus Lenses: A Two-Year Comparative Study

cs.CV ·2026-09-22 ·Zhihao Zhao, Yinzheng Zhao, Jie Zhang, Huiqin Jiang, Yanyu Shangguan +5 more
unusual similarity 0.50
Abstract

Purposes: To characterize longitudinal retinal vascular changes in myopic children treated with orthokeratology (OK) or multifocal defocus lenses (Defocus) and to examine their association with axial elongation. Methods: In this retrospective cohort study, 43 myopic children underwent comprehensive clinical examination and fundus photography at baseline, 12 months, and 24 months. Axial length (AL) and spherical equivalent refraction (SER) were recorded at baseline, 6, 12, and 24 months. An automated segmentation model extracted vascular parameters, main vessel angle (MA), branching angle (BA), bifurcation edge angle (BEA), crossover point (COP), and terminal vessel count (TVC). Repeated-measures ANOVA assessed temporal changes. Pearson or Spearman correlations evaluated associations between AL and vascular metrics. Results: Over 24 months, the OK group exhibited significantly slower axial elongation than the Defocus group (0.214 mm and 0.522 mm, p < 0.01). In the OK group, MA and BA decreased modestly, BEA in arteries declined gradually, but COP and TVC remained relatively stable. The Defocus group demonstrated more pronounced decreases in MA and BA, an increase in BEA, and significant reductions in COP and TVC (p < 0.05). Correlation analysis revealed stronger associations between AL and vascular parameters, especially COP and TVC, in the Defocus group at all time points, whereas only BA and BEA correlated with AL in the OK group. Conclusions: OK lenses mitigate axial elongation and induce milder retinal vascular remodeling compared to Defocus lenses. Distinct temporal patterns of vascular metrics changes were observed between the two interventions, and correlate differentially with axial growth.

0.26

Cross-Dataset Generalization of Glaucoma Detection CNNs: Effects of Operating Threshold, Multi-Source Training, and Color Normalization

eess.IV cs.CV ·2026-11-01 ·Al-Amin Rahman, Saifuddin Ahmed, Resalat Ahmed
similarity 0.50
Abstract · 17 pages, 10 figures, 11 tables

Deep learning models for glaucoma detection are usually tested on images from the same dataset used for training. That says little about how they will work at a new hospital or with a new camera. We fine-tuned five ImageNet-pretrained CNNs (ResNet50, DenseNet121, MobileNetV2, EfficientNet-B0, InceptionV3) with identical settings on one of three public fundus datasets (ACRIMA, ORIGA, RIM-ONE DL). Each was tested on a held-out part of its own dataset and on the other two datasets in full. We used three random seeds and report mean and SD over seeds. Mean in-domain AUC was 0.913 and cross-source AUC was 0.702, a drop of 0.211 (SD 0.030; 95% CI 0.135 to 0.286). After correction for multiple comparisons we found no evidence that any architecture did better, though three seeds give low power. At thresholds set on the source validation data, specificity fell from 0.870 to 0.506 and sensitivity from 0.831 to 0.726. Resetting the threshold on 10% of the target images raised specificity to 0.670 but lowered sensitivity to 0.609, and balanced accuracy rose only from 0.616 to 0.639. Training on two sources together did not help (held-out AUC 0.695 versus 0.702). LAB reference normalization (cross-source AUC 0.755) and strong color augmentation (0.754) gave similar gains, cutting the drop to about 0.16. Ben Graham normalization (0.733) and CLAHE (0.712) helped less, and gray-world (0.696) did not help. The two best methods raised specificity but lowered sensitivity. On G1020, used only for testing, AUC stayed near 0.5 in every condition, and networks trained within G1020 were also close to chance. Strong in-domain results do not show that a glaucoma model will work on new data. Normalization and color augmentation reduce the drop but do not remove it. Studies should report external validation and check the operating threshold, not only AUC.

0.35