CS Paper Radar

Dynamic infrared thermography and computed tomography angiography fusion for DIEP flap perforator selection: a novel measurement system

Warre Clarys, Roanne Van Steen, Simon Verspeek, Filip Thiessen, Gunther Steenackers

eess.IV physics.med-ph ·submitted 2026-11-16 05:24 UTC · v1
publishedunusual

Abstract

Accurate perforator selection is critical for successful deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. While computed tomography angiography (CTA) provides high-resolution anatomical detail, it lacks functional perfusion assessment. Dynamic infrared thermography (DIRT), in contrast, captures superficial rewarming dynamics but lacks objective anatomical validation. This study presents a standardized multimodal measurement system enabling automated fusion of DIRT with CTA-derived perforator coordinates. The framework integrates controlled thermographic acquisition, real-time hotspot detection, metric spatial calibration, and global one-to-one assignment of thermal hotspots to CTA perforators within a predefined periumbilical region of interest. The workflow was evaluated in 12 patients. Of 46 CTA perforators within the region of interest, 84.8% were successfully linked to thermographic hotspots, with a median spatial offset of 14.74 mm. Automated assignment excluded 76.1% of detected hotspots due to lack of anatomical correspondence, thereby reducing subjective interpretation. The proposed system enables quantitative multimodal validation of functional and anatomical imaging and provides objective support for perforator selection in clinical practice.

Comment
6 pages, 6 figures
Journal ref
2026 IEEE Medical Measurements & Applications (MeMeA), Montevideo, Uruguay, 2026, pp. 1-6

Closest papers

Nearest neighbours by meaning across the whole index.

Velocity Optimization via Thermal Imaging Enhances Autonomous Tumor Resection

cs.RO ·2026-10-20 ·Naveed D. Riaziat, Jiawei Ge, Ethan Kilmer, Michael W. Mikula, Paul Maria Scheikl +4 more
similarity 0.56
Abstract · submitted to IEEE Access

Objective: To demonstrate and evaluate THERMO, a thermal-velocity optimization algorithm for autonomous electrosurgery, in ex vivo porcine tissue using the UR10e-based ASTR system. Methods: Thermography for Electrosurgical Rate Modulation via Optimization (ThERMO), a closed-loop algorithm that uses real-time thermal imaging data to minimize thermal injury while ensuring accurate cut margins, was tested on ex vivo porcine tissue. Histological analysis was performed to detect thermal injury extent at a cellular level, and 3D photogrammetric measurement was used to verify margin accuracy. ThERMO's performance was compared against two previously used fixed velocity methods. Results: ThERMO outperformed both fixed velocity comparison methods without requiring data-driven training or iterative tuning, reducing thermal injury by up to 52%, improving cut accuracy by up to 59%, and maintaining task completion speed. Conclusions: Closed-loop thermal feedback via ThERMO improves autonomous robotic electrosurgery by simultaneously reducing thermal injury and improving margin accuracy, reinforcing its value over fixed velocity approaches for tumor resection applications. Significance: This work advances autonomous robotic tumor resection by demonstrating that real-time closed-loop thermal feedback control can substantially reduce collateral tissue damage and improve surgical margin accuracy.

0.23

MagViT: Interpretable Multi-Magnification Transformers with Patient-Level Model Selection for Breast Histopathology

eess.IV cs.CVcs.LG ·2026-08-16 ·Nabil Ashab, Soumit Kumar Kundu, Saif Mahmud Parvez, Shahadat Hossain Sohag, Bidhan Biswas +1 more
published similarity 0.46
Abstract · 13 pages, 5 figures, Accepted for publication in the International Conference on Electrical, Computer and Communication Technologies (ECCT 2…

Breast cancer is one of the most common types of cancer among women around the world. Rapid detection and early treatment can hinder its progress to more complex stages and can impede its spread to other parts of the body. Histopathological image classification is the most common task in cancer detection due to its robustness in analyzing cellular data. Breast histopathology classification requires handling both multi-scale tissue morphology and clinically relevant generalization beyond the source domain. This paper presents MagViT, an interpretable multi-magnification transformer framework with scale-gated fusion and patient-level model selection. The model uses four BreakHis magnifications (40X, 100X, 200X, 400X) and extracts per-scale representations with a ViT backbone, and combines them via a learnable gate that masks missing scales. Patient-level five-fold cross-validation with a fixed seed has been run and compared with three architectural branches. The most accurate branch is then selected as the final model due to the strongest patient-level accuracy while retaining the simplest fusion pathway. On BreakHis, our architecture achieves a mean image accuracy of 0.9191, a mean patient accuracy of 0.9643, and a mean macro-F1 of 0.9042. External transfer experiments provide preliminary evidence of cross-dataset generalization under controlled adaptation settings on BUSI (image accuracy 0.8306, macro-F1 0.7480, patient accuracy 0.8291) and IDC (image accuracy 0.8577, macro-F1 0.8191, patient accuracy 0.8372). Grad-CAM visualization indicates that the model focuses on diagnostically significant and meaningful regions across magnifications. Relative to prior ViT-centered BreakHis work, this study emphasizes patient-level selection and cross-dataset robustness under a reproducible protocol.

0.25

LARK: A Low-Cost, Accurate, Occlusion-Resilient, Kalman Filter-Assisted Tracking System for Image-Guided Surgery

cs.CV eess.IV ·2026-10-06 ·George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, Étienne Léger +1 more
similarity 0.46
Abstract · 24 pages, 15 figures, including appendices. Supplementary document included as an ancillary file. Supplementary video: https://youtu.be/ApZ8…

Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Commercial stereo infrared trackers are accurate but prone to occlusion and cost-prohibitive for many settings. This work presents LARK, a multi-camera optical tracking system using commodity RGB hardware and multi-view redundancy and fusion. We develop and evaluate two complete tracking methods: multi-view monocular pose fusion and multi-view triangulation. Both methods are assessed under varying occlusion levels using a precision-machined grid and an anatomical head phantom, and compared against a gold-standard stereo infrared system. With five cameras and adaptive Kalman filtering, LARK achieves median target registration errors of 0.64 mm for point localization with triangulation and 0.73 mm for trajectory tracking with pose fusion on the machined grid. Camera-subset experiments show graceful degradation in adaptive pose-fusion accuracy as fewer views remain available. With tracking hardware costing under $1,000 USD, LARK provides a low-cost platform for image-guided surgery research. Hardware designs and software are publicly available at https://nist.mni.mcgill.ca/software/ , and datasets at https://nist.mni.mcgill.ca/data/ .

0.25

Reliability-Aware Hybrid-K Ensemble Selection for Cervical Cytology Classification: Integrating Discrimination, Calibration, and Selective Prediction

eess.IV cs.AIcs.CV ·2026-09-01 ·Nisreen Albzour, Sarah S. Lam
similarity 0.45
Abstract

High classification accuracy alone is insufficient for clinical image analysis, where calibrated confidence and reliable uncertainty estimates are essential. This study proposes a reliability-aware Hybrid-K ensemble selection framework for multiclass cervical cytology classification using the SIPaKMeD dataset. Nine deep learning architectures were evaluated using a fixed stratified five-fold partition and three training seeds. After post-hoc temperature scaling, models were assessed using macro-F1, accuracy, AUROC, expected calibration error (ECE), worst-class ECE (WC-ECE), area under the risk-coverage curve (AURC), Brier score, and negative log-likelihood (NLL). Models were ranked using an equal-weight composite score, and Hybrid-K ensembles were formed from the top-ranked models using soft voting. Robustness was examined using 5,000 Dirichlet-sampled metric-weight vectors, leave-one-metric-out analysis, and corrected paired testing across 15 fold-by-seed evaluations. The final Hybrid-2 ensemble, comprising Swin-Tiny and TinyViT-5M, reduced AURC by 43%, NLL by 17%, and WC-ECE by 36% relative to the best individual model. It was selected in 96.8% of random weighting scenarios, remained unchanged across all leave-one-metric-out analyses, and improved the full composite score. However, per-metric gains were not statistically significant after Holm-Bonferroni correction (all adjusted p >= 0.168). Because post-hoc calibration did not use a fully independent calibration set, calibration-dependent results should be interpreted as exploratory internal estimates. Overall, the framework identified a compact ensemble robust to alternative metric weightings and improved reliability point estimates under internal validation on a single dataset.

0.23

Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR Images

cs.AI ·2026-08-29 ·Jakob Wasserthal, Joshy Cyriac, Michael Bach, Kimia Mozahheb Yousefi, Minh-Son To +5 more
code/data similarity 0.45
Abstract

Background: Patient details and acquisition metadata are important for clinical decisions, image quality control, and automated research pipelines, but may be missing or unreliable in imaging archives. Purpose: To develop and evaluate a fast open-source model that predicts patient and acquisition characteristics directly from CT and MR images. Materials and Methods: Separate 3D ResNet-10 ensembles for CT and MR were trained on 57,291 and 43,200 clinical examinations acquired from 2011 to 2025. Both predicted weight, height, age, sex, contrast presence, vertebral coverage, and image noise. The CT model additionally predicted scanner manufacturer, tube voltage, tube current, convolution kernel, and post-injection time; the MR model predicted sequence class. Performance was evaluated on internal CT (n=501) and MR (n=636) test sets and an external CT dataset (n=54). Results: Internal CT MAEs were 3.90 kg, 3.68 cm, and 4.42 years for weight, height, and age, with sex F1=0.990; corresponding MR results were 4.34 kg, 4.62 cm, 7.13 years, and F1=0.970. The CNN outperformed a segmentation-derived XGBoost baseline for all four core targets in both modalities (adjusted P<=.042). F1 scores were 0.963 for CT contrast, 0.953 for MR sequence, and 0.823 for MR contrast. External CT MAEs were 4.45 kg, 4.05 cm, and 5.17 years, with sex F1=0.971. CPU inference required 20 seconds for CT and 12 seconds for MR. Conclusion: One 3D multitask model per modality can rapidly recover patient and acquisition characteristics from heterogeneous CT and MR examinations. Models are available in TotalSegmentator: https://github.com/wasserth/TotalSegmentator

0.43

Evaluation Principles for MRI-MRA Registration in Trigeminal Neuralgia: An ROI-Centered Neurovascular Benchmark

cs.CV ·2026-09-08 ·Xupeng Zhang, Xihang Wang, Michael Xie, Haoyuan Liang, Hau Ern Lien +4 more
benchmarkcode/data similarity 0.44
Abstract · Includes supplementary material. Code: https://github.com/jhuldr/TN-Reg-Benchmark

Preoperative evaluation of trigeminal neuralgia (TN) often requires joint interpretation of structural MRI, which depicts the trigeminal nerve and surrounding cisternal anatomy, and time-of-flight MRA, which highlights vascular structures. Although MRI-MRA fusion is clinically attractive for visualizing neurovascular compression, this task is poorly captured by conventional whole-brain registration evaluation because the clinically relevant target is a small trigeminal ROI, vessel annotations are partial and clinically focused, local TOF-MRA contrast is variable, and field-of-view mismatch can limit deformable alignment. We formulate TN MRI-MRA fusion as an ROI-centered neurovascular registration-evaluation problem and construct a benchmark from 149 patients with clinician-annotated bilateral trigeminal ROIs. Six representative registration pipelines were evaluated using local image-based metrics, segmentation-derived vessel-localization metrics, prediction-volume analysis, and contrast- and FOV-stratified comparisons. Conventional evaluation summaries were often misleading: local image similarity, vessel-background separability, and downstream vessel localization did not co-rank methods; one-sided vessel distances were strongly affected by predicted vessel extent under partial annotations; and local MRA contrast determined when vessel-separability metrics were informative. Deformable refinement provided only a small, FOV-dependent benefit over affine alignment, while reader review showed that locally favorable vessel distances could coexist with globally implausible registrations. These findings indicate that TN MRI-MRA registration should be evaluated as a local, vessel-aware, contrast-sensitive, and FOV-aware visualization task rather than as generic multimodal brain registration. Our code is publicly available at https://github.com/jhuldr/TN-Reg-Benchmark.

0.38

Toward Interpretable Multimodal Fusion: Heat Conduction Modeling for Hyperspectral and LiDAR Joint Classification

cs.CV cs.AI ·2026-09-10 ·Kan Wei, Jiahui Cui, Jing Yao, Xinyu Zhao, Lei Wang +1 more
publishedcode/data similarity 0.44
Abstract · Accepted by IEEE TCSVT

The fusion of hyperspectral (HS) and Light Detection and Ranging (LiDAR) data plays a crucial role in enhancing land-cover classification by jointly exploiting spectral, spatial, and structural cues. However, existing multimodal fusion methods still struggle to model long-range dependencies and complex anisotropic interactions while maintaining computational efficiency. This paper introduces M2Heat, a physics-inspired framework that investigates multimodal fusion through the lens of heat conduction. At its core, a physics-driven visual heat conduction module (vHeat) and enhanced Frequency Value Embeddings (FVEs) simulate anisotropic information flow, enabling the capture of global dependencies with sub-quadratic complexity and physical interpretability. This mechanism, combined with a hybrid spatial-frequency fusion strategy named Cross-Frequency Fusion (CFF) module, produces highly discriminative and robust feature representations. M2Heat achieves competitive overall performance on three benchmarks, i.e., Trento, Houston2013, and Augsburg, while providing an interpretable heat-conduction-guided perspective for multimodal feature fusion. These results indicate the potential of heat-conduction-guided neural operators for efficient and interpretable RS multimodal fusion. The source code is publicly available at https: /github.com/Weikan0425/M2Heat_HSI_LiDAR.

0.53

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.44
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52