CS Paper Radar

Fix, Don't Retake: Physics-Simulated Training for Correcting Patient Positioning Errors in Dental Panoramic Radiographs

Sema Helali, Lina Abu Nada, Faleh Tamimi, Rafat Damseh

cs.CV cs.AI ·submitted 2026-11-16 16:04 UTC · v1
unusual

Abstract

Patient-positioning errors can distort panoramic radiographs and lead to repeat examinations. This study investigated artificial intelligence for correcting these errors in existing images. A physics-based simulator generated paired correctly positioned and mispositioned panoramics from cone-beam computed tomography volumes, with controlled individual and combined positioning errors. Five approaches were compared: U-Net, pix2pix, conditional diffusion, an error-conditioned model, and a mixture of error-specific specialists. Evaluation used image similarity and geometric metrics across three test sets. All approaches improved mean image similarity and reduced geometric errors, with U-Net and the two error-aware approaches outperforming pix2pix and conditional diffusion.

Comment
Submitted to ISBI for review

Closest papers

Nearest neighbours by meaning across the whole index.

CarDiff: Anatomically Aware Dental Caries Synthesis using Diffusion

cs.CV cs.LG ·2026-10-13 ·Sanyam Jain, Bruna Neves de Freitas, Alexandros Iosifidis, Ruben Pauwels
code/data similarity 0.57
Abstract

Synthetic medical image generation can help address limited annotated data in dental imaging, particularly for under-represented caries classes. In this work, we present CarDiff, a semi-supervised framework for dental caries synthesis in panoramic radiographs. The method combines paired mask-image learning with self-supervised generation from augmented masks, while incorporating anatomy-aware conditioning between lesion regions and surrounding structures. Semantic consistency is enforced through segmentation-guided supervision and adversarial anatomical alignment. Experiments on the MLUA-DC1000 dataset show that CarDiff achieves improved synthesis quality compared with existing semantic synthesis baselines, obtaining the best Fréchet Inception Distance (FID) (90.76) and Learned Perceptual Image Patch Similarity (LPIPS) (0.48) scores among evaluated methods. We further assess the generated radiographs for downstream segmentation augmentation across seven architectures. Using a 5x augmented training set improves average Dice score by up to 6.5%, with larger gains observed for medium and combined lesion classes. These results suggest that anatomically consistent diffusion synthesis may be useful for dental radiograph augmentation under limited supervision. The code is available at https://github.com/s4nyam/CarDiff.

0.32

Image-Conditioned Diffusion Models for Quality Assurance of Organ-at-Risk Segmentations in Radiotherapy

cs.CV ·2026-08-24 ·Clea Dronne, Catharine H Clark, Xavier Loizeau, Elizabeth Miles, Peter Hoskin +1 more
hot direction similarity 0.55
Abstract · Submitted to the MICCAI 2026 UNSURE Workshop

Accurate organ-at-risk segmentation is essential for radiotherapy planning, but reviewing segmentations is time-consuming and subjective. We investigate normative modelling for segmentation error detection in head-and-neck CT, comparing a VAE framework with an image-conditioned segmentation diffusion model. Models were evaluated on RADCURE brainstem and spinal cord segmentations using simulated boundary and width perturbations. Error detection was assessed using the Dice similarity coefficient and the Distance to Agreement (DTA) between the input and reconstructed segmentations. While both models detected some simulated errors, regional DTA showed that the diffusion model localised subtle boundary errors more consistently. These results support image-conditioned diffusion reconstruction as a promising framework for localised, anatomy-aware segmentation QA.

0.36

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

cs.CV ·2026-10-05 ·Qi Lai, Yutong He
code/data similarity 0.55
Abstract

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We present RefineCBCT, an unpaired CBCT refinement framework that uses pseudo-label guidance and short-step diffusion to reduce artifacts while preserving patient-specific anatomy. RefineCBCT was trained and evaluated on unpaired CBCT and planning CT data from public LUNG TCIA and PELVIC TCIA datasets and compared with representative GAN and diffusion based methods. On LUNG TCIA, it achieved the best results across all metrics, with MAE 19.411, RMSE 62.758, PSNR 30.845 dB, and SSIM 0.931. On PELVIC TCIA, it achieved the best MAE, PSNR, and SSIM, with values of 14.905, 36.671 dB, and 0.876. The refined images showed fewer streaking and shading artifacts, clearer anatomical boundaries, and improved soft tissue uniformity, with line profile and ROI analyses showing closer agreement with planning CT. These results suggest that RefineCBCT provides efficient and effective CBCT refinement under clinically realistic unpaired training conditions and may support more reliable CBCT use in image-guided radiotherapy workflows. Code is publicly available on GitHub, and the evaluated datasets are available from The Cancer Imaging Archive.

0.21

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.54
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.28

ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT

cs.CV ·2026-11-18 ·Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong +3 more
similarity 0.54
Abstract

Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.

0.27

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data similarity 0.53
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.28

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

eess.IV cs.CV ·2026-09-09 ·Zhichun Jin, Zhicheng He, Hao Xu, Dongyang Li, Lin Wang +2 more
published similarity 0.53
Abstract · Accepted by Biocybernetics and Biomedical Engineering

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

0.36

Patient-Level, Leakage-Aware Deep Learning for Cross-Center Periapical Radiograph Classification

cs.CV ·2026-09-13 ·Md Jubaer Rahman, Ulas Bagci
benchmark similarity 0.52
Abstract · Submitted to the 9th International Conference on Signal Processing and Information Security (ICSPIS 2026)

Dental caries and endodontic disease are among the most common health conditions worldwide, and intraoral periapical radiographs are central to their detection, treatment planning, and follow-up. Automated tooth-level classification of these images, however, lacks reproducible benchmarks, is often evaluated with image-level splits that leak patients between training and test, and is rarely validated across clinics. This paper presents the first patient-level, leakage-aware classification benchmark for single-tooth intraoral periapical radiographs on the DentIRO dataset, which comprises 5,300 images from 3,243 patients across two clinics and four classes: Healthy, Caries, Crowned, and Root Canal. Five transfer-learning models are compared with patient-grouped stratified cross-validation, so that every patient remains within a single fold. DenseNet121 gave the strongest and most stable result at a mean macro-F1 of 0.9787, while the four ImageNet-initialized backbones performed comparably. A controlled comparison on a fixed architecture showed that chest-radiograph pretraining transferred less effectively than ImageNet initialization. Bidirectional cross-center validation produced a small average generalization gap of 0.0077, and Grad-CAM confirmed that predictions rely on clinically meaningful tooth regions rather than acquisition artifacts. The benchmark offers a rigorous and reproducible baseline for intraoral radiograph classification.

0.29