Load-Following Dynamics of an SMR-Powered All-Electric Ship with Battery Energy Storage

Ali Mahboub Rad, Jie Zhang

eess.SY ·submitted 2026-11-20 18:30 UTC · v1
published

Abstract

Small modular reactors (SMRs) are being considered as compact, high-energy-density power sources for future all-electric ships. In such systems, propulsion-load variations can propagate through the electrical network, turbine-generator set, steam generator, and reactor, producing coupled nuclear, thermal, mechanical, and electrical transients. This paper presents an integrated dynamic load-following analysis of an SMR-powered all-electric ship with and without battery energy storage system (BESS) support. The model couples an integral pressurized water reactor, a once-through moving-boundary steam generator, a simplified turbine model, a synchronous generator, an AC shipboard electrical network, an asynchronous propulsion motor, and a grid-connected BESS. A propulsion-load reduction is applied through the motor torque command, and the responses of the SMR-alone and SMR+BESS configurations are compared. The results show that, without BESS support, the sudden decrease in propulsion motor power creates a temporary surplus between turbine mechanical power and electrical demand, causing a large over-frequency transient and rapid steam-cycle adjustment. With BESS support, the battery absorbs excess electrical power during the transient, reducing the frequency peak from approximately 61.1 Hz to about 60.06 Hz. The BESS also indirectly smooths the upstream steam-cycle and reactor responses, including steam flow, steam-generator pressure, feedwater flow, coolant temperature, reactivity, reactor thermal power, and steam-generator region lengths. These results demonstrate the importance of modeling nuclear-powered electric ships as coupled multi-domain systems and show that BESS integration can improve short-term load-following performance.

Journal ref
International Congress on Advances in Nuclear Power Plants (ICAPP 2026), Phoenix, AZ, November 15-18, 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Linear Modeling of Hybrid Shipboard Power Systems under Pulsed Power Load Operation

eess.SY ·2026-11-13 ·Daniele Roncagliolo, Pietro Cepollini, Fabio D'Agostino, Marco Gallo, Federico Silvestro
published similarity 0.61
Abstract · Accepted and presented at ESARS-ITEC 2026. Copyright 2026 IEEE. Personal use of this material is permitted. Permission from IEEE must be obt…

A model-based approach is a valuable tool in the power system design process, enabling the integration of component models and the evaluation of dynamic interactions. Simplified models support rapid preliminary assessments by allowing parameters and configurations to be adjusted. This paper investigates the effects of high-bandwidth loads in hybrid AC--DC shipboard power systems. The problem is addressed by developing a linear model aimed at capturing the relevant dynamics over the time scale of interest with reduced computational effort. A LVDC subsystem has been developed with a battery energy storage system that supports the grid during pulsed power load operation. A control strategy has been proposed to satisfy transient requirements. The proposed approach is validated under different pulsed power load conditions using a high-fidelity model developed in DIgSILENT PowerFactory, which preserves nonlinearities and includes converter switching effects and digital control implementation. The validation shows that the model captures the relevant transient behavior with significantly reduced simulation time, while maintaining acceptable accuracy, making it suitable for rapid preliminary design studies.

0.31

Power Management of Electrically Driven Centrifugal Compressors for Flexible Operation

eess.SY ·2026-11-13 ·Alp Albay, Tak Lam Fok, Niklaus Hung, Maiken Omtveit, Mehmet Mercangöz
unusual similarity 0.50
Abstract

We present a control strategy for power management of a variable-speed 15MW (rated power) centrifugal compressor, and investigate how quickly it can follow a reduced electrical power reference without entering surge. We use a Greitzer-Gravdahl type model scaled to industrial size with rate-limited valve actuators as a simulation environment and propose an advanced regulatory control structure using feedback control loops with dynamically scaled feedforward mechanisms and a structure of min/max selectors. In simulated experiments, a 6MW power reduction from varying initial operating points on a 12MW iso-power line is delivered at rates of up to 10MW/s, i.e.to 90% in 0.54s, without opening the recycle valve. Depending on the initial operating point, a large power reduction can be delivered at once or with a restricted ramp rate. The stroking rate of the discharge side valve is identified as the limiting factor for how fast the power can be reduced in the studied configuration. A limited sensitivity study on the impact of rotor inertia for power shedding performance is also provided.

0.25

Flexible Training Workloads in Large-Scale AI Data Centers for Transient-Stability Support in Transmission-Constrained Power Systems

eess.SY ·2026-08-31 ·Jae-Kyeong Kim
similarity 0.49
Abstract · 11 pages, 7 figures, 1 table

The rapid expansion of large-scale artificial intelligence (AI) data centers is adding substantial, concentrated, and rapidly varying loads to transmission-constrained power systems. Although such load variations are generally regarded as operational challenges, this paper presents an alternative perspective in which the upward load flexibility of AI data centers could be coordinated for transient-stability support. To this end, this paper proposes training-induced load surge (TILS), a fast demand-side strategy that initiates or resumes flexible AI training workloads after fault clearing to increase active-power demand at electrically effective locations. The resulting load increase allows accelerating generators to supply additional electrical power, thereby reducing the accelerating-power imbalance and limiting the first-swing rotor-angle excursion. The underlying mechanism is first clarified in a single-machine infinite-bus (SMIB) system and then evaluated in the IEEE 39-bus system and a large-scale Korean power system. Results across all three systems demonstrate that TILS can increase the transient-stability-constrained generation limit. Larger responses, earlier activation, and siting at buses with a stronger electrical influence on the critical generators provide greater generation-limit increases. These results suggest that the upward load-response capability of AI data centers can provide complementary transient-stability support when sufficient electrical headroom, flexible workloads, and reliable grid-triggered activation are available.

0.29

Resilient Design and Optimal Operation of Battery Energy Storage Systems for Behind-the-Meter Data Center Microgrids

eess.SY ·2026-09-16 ·Hamed Haggi, Chinmay Morankar
similarity 0.48
Abstract · Under Review

This paper proposes a high-fidelity hyperscale data center load modeling framework that disaggregates facility demand into IT and non-IT components and represents load behavior at second- and minute-level resolutions. Building upon this foundation, a comprehensive multi-phase optimization framework is developed for the planning and resilient design of BESS for BTM data center microgrids. The framework deploys BESS on the load side to act as a dynamic buffer between stochastic demand and generation assets. By smoothing the load spikes and excursions before they are observed by gas turbines, the load-side BESS reduces operational stress and limits conditions that can contribute to SSTI issues, shaft fatigue, system trips, equipment damage, and forced outages. Simultaneously, generation-side BESS resources are optimally sized to provide spinning reserves and enhance system resilience. The proposed methodology co-optimizes BESS with solar, wind, natural gas fuel cells, simple-cycle gas turbines, and combined-cycle gas turbines while incorporating operational, reliability, resiliency, and technology-specific constraints. Simulation results demonstrate the proposed methodology's ability to identify cost-effective, resilient, and operationally feasible designs that satisfy the demanding reliability requirements and energy market challenges of next-generation hyperscale data centers while providing planning insights for investors, developers, and system operators.

0.19

Passivity Control for Synchronous Machine Systems using Battery, Field Current and Governor Actuation

eess.SY ·2026-11-17 ·Maryam Khodabakhshloo, Elizabeth L. Ratnam, Ian R. Petersen
similarity 0.48
Abstract

The passivity of synchronous machines enables power system stability to be established from local conditions. A recent state-feedback design enforces robust passivity using battery actuation at the machine terminal bus. This paper extends that design to a model that includes the field winding and the dynamics of a steam turbine and its governor. The extended model provides two additional actuator signals: the exciter input and the governor input. The nonlinear terms in the model depend on speed and field current deviations, and are represented as bounded uncertainties. Robust positive real conditions are derived in terms of a single algebraic Riccati equation. From its solution, a state-feedback controller is designed in closed form. Numerical results show that, unlike the design with battery actuation alone, the proposed controller leads to passivity at all loading levels when the damping is low.

0.10

Communication Delay Robust Control of BESS for AI Training Load Smoothing

eess.SY ·2026-09-18 ·Xue Lyu, Wei Du, Sheik Mohammad Mohiuddin, Brett A. Ross
hot direction similarity 0.48
Abstract · 10 pages, 17 figures

AI training loads can exhibit rapid power fluctuations because their power demand differs significantly between computational and communication phases, creating challenging ramp rates at the data center point of common coupling (PCC). Integrating battery energy storage systems (BESS) in data centers is a promising mitigation option. This paper proposes a hybrid BESS control strategy that combines droop-based grid-forming (GFM) control with instantaneous load current-based compensation to suppress high frequency load fluctuations. The GFM control loop regulates the long-term power exchange of the BESS, while the load-following control provides fast compensation for short-term AI workload fluctuations. Communication delay between the load current measurements and the BESS controller is explicitly modeled, and its impact on smoothing performance is analyzed. To mitigate delay-induced degradation, a predictor-based compensation method is incorporated into the BESS control structure. High-fidelity electromagnetic transient simulations are conducted to validate the proposed approach. Results demonstrate effective smoothing of AI training load fluctuations across different grid strength conditions and under time varying communication delays.

0.28

Coordinated Conservation Voltage Reduction and Network Topology Reconfiguration in Active Distribution Networks

eess.SY ·2026-10-12 ·Rida Fatima, Hassan Zahid Butt, Xingpeng Li
similarity 0.48
Abstract

Distribution networks rely on conservation voltage reduction (CVR) and network topology reconfiguration (NTR) to manage demand, distributed energy resources (DERs), and tighter operating margins. Yet these strategies are typically deployed independently, despite coupled effects on feeder voltages, losses, and loading. This paper addresses that gap by developing a day-ahead mixed-integer second order cone programming (MISOCP) framework that jointly optimizes feeder head voltage control and network reconfiguration. The formulation incorporates AC branch flow constraints, ZIP load models, DERs, battery energy storage systems, and multi substation radiality. Using modified IEEE 33 bus and 123 bus systems, four configurations isolate the individual and coordinated effects of CVR and NTR. On the 33-bus system under mixed ZIP loading, NTR reduces active energy loss by 2.50%, while coordinated operation reduces it by 2.91% relative to SDN and produces a 2.46% CVR induced active load reduction relative to SDNTR. Under constant impedance loading, coordinated operation reduces active energy loss by 17.65% relative to SDN, while CVR reduces active load by 14.61% relative to SDNTR. DER portfolio scaling shows a nonmonotonic coordinated load reduction response, strongest at 20% penetration and decreasing at higher levels. On the 123 bus system, NTR reduces losses by 19.3%, while CVR reduces voltage dependent load energy by 2.3 to 2.4%. Under loading stress, SDN becomes infeasible at 120% loading, whereas CEDNTR remains feasible. Overall, the results demonstrate complementary, operating condition dependent benefits shaped by load composition, DER portfolio scaling, feeder topology, voltage margins, and source constraints, highlighting the value of joint optimization.

0.29

Development of an EMT model of the Balearic power system

eess.SY ·2026-09-02 ·Yousef Pipelzadeh, Dharshana Muthumuni, Farid Mosallat, Javier Renedo, Silvia Sanz Verdugo +3 more
similarity 0.47
Abstract

The Balearic Islands are striving to achieve 100% renewable energy, which poses new challenges in operating the power system securely and reliably. With a higher integration of inverter-based resources (IBRs) and a reduced presence of conventional synchronous generators, the system strength, particularly short circuit levels, becomes weaker and more susceptible to disturbances; and the total inertia of the system becomes lower. Technology enablers are planned to achieve energy transition in the Balearic power system: a new 2x200 MW VSC-HVDC link (bipole with metallic return), Synchronous Compensators (SC) and Battery Energy Storage Systems (BESS), as fully-integrated network components. Detailed ElectroMagnetic Transient (EMT) simulation studies may be needed to analyse stability of the system, due to the high amounts of power-electronics devices in the system. This paper describes the implementation of an EMT model of the Balearic power system.

0.22