CS Paper Radar

Benchmarking Foundation Models for Bone Scaffold Pore Detection: A Comparative Analysis of Few-Shot Performance

Tri Tin Vo, Vu Thien An Ngo, Nhi Kieu, Cuong Hung Luu, Giang V. H. Phan, Kien Nguyen, Clinton Fookes

cs.CV ·submitted 2026-11-18 04:18 UTC · v1
top venuebenchmarkhot direction

Abstract

Evaluating the mechanical properties of bone scaffolds conventionally requires destructive testing or costly Finite Element Analysis, while deep learning alternatives are constrained by the scarcity of labeled biomaterial imaging data. This study introduces the first expert-annotated, pixel-dense dataset of biopolymer bone-scaffold SEM images, spanning five magnification series, and uses it to benchmark two state-of-the-art pre-trained foundation models under a 12-shot fine-tuning regime. SAM3, an instance segmenter, and YOLOv26, a bounding-box detector, feed the predicted pore geometry to regression heads that estimate Young's modulus and compressive yield strength. Our central finding is that both models fail by pore density rather than magnification: YOLOv26's predicted pore counts saturate and porosity estimation collapses on the most crowded frames, whereas SAM3 over-fragments sparse pore fields and merges adjacent pores in dense ones, producing eight catastrophic failures against three for YOLOv26. Averaged across the 44-image evaluation set, YOLOv26 achieves lower porosity error (19.9% vs. 23.1% MAE), higher precision, and a higher F1 score, whereas SAM3 offers pixel-level instance segmentation that YOLOv26's bounding boxes cannot reproduce. We conclude that model selection should be driven by pore density rather than SEM magnification alone.

Comment
16 pages, 5 figures, 3 tables. Accepted at the Australasian Data Science and Machine Learning Conference (AusDM 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Adapting a Vision Foundation Model for Fracture Characterization in Acoustic Image Logs

cs.CV ·2026-11-10 ·Guangyu Wang, Xiaodong Ma, Xinming Wu
similarity 0.64
Abstract

Natural fractures (NFs) and drilling-induced tensile fractures (DITFs) in acoustic image logs provide insights into rock mass structure and in situ stress, but manual characterization is time-consuming. Deep learning can automate this task, although expert-labeled data are scarce. We investigate whether adapting a pretrained vision foundation model (VFM) outperforms task-specific models trained from scratch with limited annotations. Using 80 annotated acoustic image samples, we fine-tuned DINOv3, pretrained on satellite imagery, and evaluated it on four boreholes excluded from fine-tuning. The adapted model estimated NF and DITF parameters comparably to human interpretation. Relative to U-Net, YOLOv8, and Swin Transformer models trained from scratch, it yielded fewer false positives and negatives and more accurate fracture counts and orientations. However, its performance advantage generally narrowed as training sample size decreased. We also assessed decoder architecture, fine-tuning strategy, and image enhancement. A progressive upsampling decoder with full fine-tuning performed best among the DINOv3 configurations tested, while fracture-focused image enhancement did not consistently improve accuracy. These results demonstrate the potential of VFM adaptation for fracture characterization in acoustic image logs with limited labeled data and suggest a transferable workflow for other annotation-scarce geoscientific imaging tasks.

0.28

A Seismic Foundation Model for Dense Feature Extraction

cs.CV ·2026-11-16 ·Zhixiang Guo, Xinming Wu, Yimin Dou, Hui Gao, Siyao Zhao +2 more
similarity 0.60
Abstract

Deep-learning-based seismic interpretation is constrained by scarce high-quality annotations, and most existing models are trained separately for individual tasks. We present SeisDFE, a 7B-parameter seismic foundation model for dense feature extraction, pretrained on 5.34 million 2D images derived from more than 500 seismic volumes. A three-stage pretraining strategy, combining discriminative self-supervised learning, Gram feature anchoring, and multi-resolution adaptation, improves feature discriminability while preserving spatial coherence. With its encoder frozen, SeisDFE supports seismic facies classification, salt detection, fault detection, and relative geologic time estimation. It outperforms existing seismic foundation models on all four tasks and a natural-image-pretrained model on all but fault detection, with the largest gains under scarce supervision: using only two annotated sections of the F3 dataset, it improves whole-volume mIoU by 12-19 percentage points over the baselines. The learned features remain effective with task-specific decoders and extend to synthetic-to-field transfer and sparse 3D geobody interpretation. These results show that large-scale seismic pretraining organizes geological information into dense representations that are directly reusable across interpretation tasks.

0.23

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
similarity 0.59
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.19

HERO: Histology Encoder for Robust Representation in Oncology

cs.CV ·2026-09-28 ·Zhi Li, Eghbal Amidi, Yating Cheng, Tyson Dawson, Gorkem Can Ates +9 more
benchmarkcode/data similarity 0.59
Abstract · 22 pages, 4 figures, 13 tables; author information updated; scientific content unchanged

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.

0.22

Image-Based Breast Implant Detection for Mammography Dataset Curation and Near-Real-Time Deployment: Comparing Foundation Models and Task-Specific Convolutional Models

eess.IV cs.CVq-bio.TO ·2026-10-01 ·Vasisht Ishwar, Hari Trivedi, Young Seok Jeon, Beatrice Brown-Mulry, Frank Li +3 more
similarity 0.59
Abstract · 15 pages, 6 figures, 2 tables. Submitted to the Journal of Imaging Informatics in Medicine

Purpose: To evaluate the performance-feasibility tradeoffs of foundation models (FMs) and task-specific convolutional neural networks (CNNs) trained from scratch for breast implant classification in 2D mammography, with emphasis on suitability for near real-time clinical deployment. Methods: We evaluated four models: two FMs (RAD-DINO and MammoCLIP) and two CNNs trained from scratch for implant prediction (ResNet18 and our lightweight ResNetLite). Using the Emory Breast Imaging Dataset, 5,000 unilateral screening mammograms were used for training/validation and 1,000 manually reviewed unilateral images were held out for testing. For the FMs, global image embeddings from the pretrained encoder were classified using a support vector machine (SVM). The CNNs were trained end-to-end on 2D mammograms, with ResNetLite optimized via grid search over depth and width to balance accuracy and efficiency. Performance was evaluated using AUROC, sensitivity, specificity, accuracy, embedding visualization, and inference-latency. Results: All models demonstrated strong performance on held-out test data (n = 1,000). MammoCLIP achieved the highest AUROC (0.999) with the quickest training time of 493 seconds. RAD-DINO achieved the highest sensitivity (0.980; accuracy 0.989) but had the slowest inference and training times. ResNet18 and MammoCLIP achieved comparable accuracy (0.985). ResNetLite showed no statistically significant difference from ResNet18 (AUROC 0.993; accuracy 0.976) despite using only 1.4% of ResNet18's parameters, and had the fastest inference time. Conclusion: FMs and task-specific CNN models reliably detect breast implants on 2D mammography. Model selection is best guided by deployment context: MammoCLIP for GPU-equipped hospital settings requiring scalable integration, and lightweight CNNs such as ResNetLite for resource-constrained or edge deployments.

0.12

TEMPL: A Resource-Efficient and Transparent Model-Free Framework for Pseudo-Label Generation in Material CT Scans

cs.CV ·2026-10-20 ·Ashiqur Rahman, Venkata Devesh Reddy Seethi, Austin Yunker, Rajkumar Kettimuthu, Hamed Alhoori
similarity 0.59
Abstract

The scarcity of large annotated datasets limits deep learning (DL) segmentation in material CT analysis. DL-based pseudo-labeling can help, but it is often computationally expensive and hard to interpret. We introduce a multi-stage, model-free framework that generates pseudo-labels directly from grayscale CT scans. It combines thresholding, morphological dilation, and a custom breadth-first search region-growing algorithm to produce polygonal annotations without pre-trained weights, labeled data, or a GPU. We compare it against the zero-shot Segment Anything Model (SAM), a fully supervised 3D U-Net, and classical baselines. On a dendrite dataset with ground truth, our method reaches 63.19% IoU versus 10.74% for zero-shot SAM, with four times the instance recall at 0.5 IoU (33.3% versus 8.3%). The supervised 3D U-Net serves as a reference ceiling that requires expert labels. On a silica sand specimen, YOLO models trained on our labels performed comparably to models trained on SAM labels in a qualitative comparison. Across 1,053 extracted grains, the median equivalent diameter was 163.8 micrometers, near the specimen's known 106 to 150 micrometers sieve range, compared with 219.5 micrometers for SAM, whose labels merge adjacent particles and add spurious detections. A sensitivity analysis shows a stable operating range for the key threshold and a sharp, predictable failure point linked to phase contrast. Our method needs 15s per image on a standard CPU versus 28s for SAM on a GPU. These results support our transparent approach as a tool for annotation bootstrapping and microstructural quantification in resource-limited settings.

0.13

Toward Foundation Detection Models via Example-Based Grounding in EM-DETR

cs.CV cs.AI ·2026-11-10 ·Sheethal Bhat, Bogdan Georgescu, Awais Mansoor, Florin C. Ghesu, Sasa Grbic +1 more
similarity 0.58
Abstract

DeepLearning (DL)-based Computer-Aided Diagnostic (CAD) systems have shown great promise in supporting clinicians, but their performance heavily depends on the availability of large, well-annotated datasets. In medical lesion detection, the scarcity of comprehensive, stan dardized annotations and the heterogeneity of existing datasets limit the development of robust foundation models. In this work, we introduce a novel approach to building a multi-domain foundation model for le sion detection by integrating diverse medical image datasets annotated for both anatomical structures and abnormalities. We first propose a student-teacher training strategy to effectively combine datasets with heterogeneous label spaces, mitigating catastrophic forgetting, and im proving feature learning. In addition, building on our previously pro posed example-based EM-DETR framework, we adapt it to jointly learn from multiple domain-specific datasets, enabling fine-grained, example driven detection across modalities. Our model achieves state-of-the-art (SOTA) results, with image-level AUC scores exceeding previous SOTA by 1% point on four key findings in CXRs. We achieve a leading mAP50 in CXRs and mammography, surpassing EM-DETR trained on a single dataset by 2-3% points. This approach paves the way for scalable foundation models in medical imaging that leverage heterogeneous data while maintaining robust and generalizable performance.

0.12

Integrating Local Detail and Global Context: A Dual-Input Multi-Task Learning Framework for Bone Tumor Diagnosis

eess.IV cs.CV ·2026-09-23 ·S. M. Nasif Uddin, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi +1 more
similarity 0.58
Abstract

Primary bone tumors are rare but clinically aggressive neoplasms whose diagnosis from radiographs is challenged by heterogeneous morphology, subtle lesion margins, and overlapping bone structures. To address the limitations of existing single-view models, we present a dual-input, multi-task learning framework that, to our knowledge, is the first to apply bidirectional cross-modal attention between a lesion crop and the full radiograph for joint segmentation and subtype classification. Using the multi-institutional Bone Tumor X-ray Radiograph Dataset (BTXRD, n=3,746), we employ a YOLO-based detector to generate regions of interest, which are paired with full images as inputs to a dual-stream DenseNet121 architecture. Features are integrated via a novel cross-modal attention fusion strategy, refined by Hierarchical Multi-scale Feature Fusion, effectively balancing fine-grained lesion detail with global anatomical context. Evaluated on a held-out patient-level test split, the model demonstrates superior performance over single-input baselines, achieving an overall Dice Similarity Coefficient of 0.896 and a macro-averaged classification F1-score of 0.928. Notably, the system exhibits exceptional sensitivity for malignant osteosarcoma (AUC 0.999), validating the potential of dual-stream context modeling to support radiologists in accurate, early decision-making.

0.20