CS Paper Radar

Dynamics-Guided Conditional MeanFlow from Regional Interaction to Internal Revision and Its Application to CT Imaging

Md Shifatul Ahsan Apurba, Md Selim, Jin Chen

cs.CV ·submitted 2026-11-19 05:38 UTC · v1

Abstract

Conditional image enhancement requires spatially varying corrections, yet fixed-depth models allocate similar computational budgets regardless of where additional refinement is needed. Although one-step flow models reduce inference costs and iterative restoration methods introduce subsequent corrections, how predicted transformation dynamics can guide internal feature refinement remains underexplored. We introduce IRCMF, a dynamics-guided Conditional MeanFlow framework that combines regional interaction with recurrent internal revision. The decoder predicts signed interval velocity and a learned velocity-change cue. A soft-region graph aggregates contextual information for velocity estimation, while a dynamics-conditioned graph establishes regional relationships to guide recurrent bottleneck updates. The revised features are processed by the shared decoder to recompute velocity, establishing feedback between transformation dynamics and internal representations. An actor-critic policy controls regional updates and further revisions to balance enhancement quality and computational cost. We evaluate IRCMF on two computed tomography (CT) datasets, NLST for STANDARD-to-LUNG kernel enhancement and LDCT-and-Projection-data for simulated low-to-routine-dose enhancement. With nine decoder evaluations, IRCMF achieves slice-level PSNR of $36.24 \pm 3.49$ dB and SSIM of $0.97 \pm 0.01$ on NLST, and PSNR of $32.45 \pm 1.97$ dB and SSIM of $0.84 \pm 0.05$ on LDCT-and-Projection-data. The learned policy reduces average decoder evaluations to 4.42 and 3.45, respectively, lowering per-slice latency from 97.00 to 51.82 ms and from 97.12 to 41.95 ms, with PSNR reductions of only 0.20 and 0.06 dB.

Closest papers

Nearest neighbours by meaning across the whole index.

Dual-Domain Sparse-View 4D CBCT Reconstruction with Spatial-Temporal Consistency Learning

cs.CV ·2026-10-13 ·Qi Lai, YuTong He
similarity 0.67
Abstract

Four-dimensional cone-beam computed tomography (4D CBCT) provides phase-resolved volumetric images for image-guided radiotherapy. Yet good reconstruction quality usually needs many projections. This increases scan time and radiation dose. We propose STCNet, a sparse-view 4D CBCT reconstruction framework that uses spatial-temporal consistency learning. STCNet reconstructs high-quality images from only 16 projections in each respiratory phase. STCNet integrates physics-driven positional encoding to enforce geometric consistency in the projection domain and introduces temporal encoding in latent space to capture respiratory motion dynamics across phases to capture dynamic respiratory motion across phases. A dual-domain collaborative strategy jointly optimizes both projection and image domains, enhancing structural fidelity and temporal coherence. We tested STCNet on the TCIA-LUNG dataset and a CIRS thorax phantom dataset. STCNet performed better than conventional methods and recent deep learning baselines in image quality, artifact reduction, and structural preservation. On TCIA-LUNG, STCNet reached PSNR values of 33.311, 32.695, and 32.658 dB at phases 2, 5, and 8. The corresponding SSIM values were 0.845, 0.823, and 0.825. On CIRS, STCNet achieved PSNR values up to 36.497 dB and SSIM values up to 0.877. These results support STCNet as a promising framework for low-dose, phase-resolved 4D CBCT reconstruction in image-guided radiotherapy.

0.12

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.66
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.41

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.66
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

Large-Small Model Collaboration for Zero-Shot Surgical Phase Recognition

cs.CV ·2026-08-24 ·Yiyi Zhang, Ying Zheng, Wenxin Fan, Yu Zhu, Yuchen Yuan +3 more
top venuecode/data similarity 0.66
Abstract · MICCAI 2026 Early Accept

Task-specific lightweight models for surgical phase recognition excel at capturing temporal dynamics but generalize poorly under domain shift. Conversely, surgical foundation models (FMs) offer superior transferability via large-scale pretraining, yet their lack of explicit temporal modeling often yields temporally inconsistent predictions, leading to degraded performance. To exploit the complementary strengths of both paradigms, we propose \textbf{La}rge-\textbf{S}mall \textbf{T}emporal adaptation (\textbf{LaST}), a novel large-small collaborative framework that enables zero-shot adaptation to unseen clinical domains. In LaST, the FM initiates the pipeline by generating frame-level phase priors that serve as initial weak supervision. To effectively utilize these noisy phase priors, we introduce an iterative temporal refinement scheme that integrates dynamic quality control to filter reliable predictions and dual-model cross-learning to mitigate confirmation bias. Simultaneously, the lightweight model leverages its intrinsic temporal modeling ability to progressively correct inconsistent predictions and enhance overall accuracy across iterations. At the end, a cycle replay strategy is employed to close the loop: the refined, more accurate predictions are utilized as upgraded supervision signals for the subsequent iterations, fostering a self-reinforcing evolution of both label quality and model capability. Extensive experiments demonstrate that LaST achieves robust adaptation to unseen domains for zero-shot surgical phase recognition, outperforming the baseline (PeskaVLP) by 24.85\%-43.17\% in accuracy and even surpassing fully supervised linear probing and several state-of-the-art few-shot approaches. Codes will be released at https://github.com/YIYIZH/LaST.

0.73

ReVision3D: Attribution-Guided Recursive Self-Improvement for 3D Medical Perception

cs.CV ·2026-09-26 ·Ho Hin Lee, Yuyin Zhou, Yannan Yu, Shi Gu, Yifan Wu
code/data similarity 0.65
Abstract · 28 pages

Recursive self-improvement (RSI) offers a promising path for overcoming the limited visual capability of current medical imaging agents. Yet applying RSI to volumetric imaging remains difficult: failures can arise from acquisition, perception, training recipe, or downstream inference, while self-generated feedback and logged trajectories provide little guidance on which component should change. We introduce ReVision3D, an RSI system that leverages 3D volumes with spatially grounded annotations to determine where visual evidence is lost and recursively improve the corresponding visual capability. A frozen language-model designer proposes revisions to acquisition, perception, training, or inference, while the verifier and system-level objective remain fixed. Our key insight is that an annotated volume forms an exact replay world for view rendering and spatial verification: unvisited views can be rendered on demand, and localized predictions can be checked directly against reference masks. This grounded feedback directs targeted revision, while only changes that improve beyond measured seed noise are retained. Each accepted change triggers renewed attribution, allowing the dominant bottleneck to shift across rounds. On abdominal CT, attribution identifies perception as the dominant remaining limitation. Revising that level enables ReVision3D to achieve 79% liver recall and 83% kidney recall at under 0.4 false positives per patient, outperforming the evaluated frozen multimodal foundation models, with the largest gains on small lesions. Our framework is public available with interactive demo in this project page: \url{https://leeh43.github.io/ReVision3D/}

0.60

SynthRCT: Scalable Conditional Deformation Synthesis for Synthetic Repeat CT Generation

cs.CV cs.AIcs.LG ·2026-09-08 ·Tomas Guija-Valiente, Blanca Rodriguez-Gonzalez, Norberto Malpica
publishedcode/data similarity 0.65
Abstract · 11 pages, 4 figures. Accepted at the MIART Workshop, MICCAI 2026. This preprint corresponds to the initial submission prior to peer review

In proton therapy, plans are typically optimized on a single planning CT, making robustness evaluation essential under anatomical changes. However, current scenarios often rely on simplified perturbations that poorly capture complex, patient-specific variability. We propose SynthRCT, a scalable conditional generative framework for 3D anatomical deformation synthesis. Based on a conditional variational autoencoder, SynthRCT learns a latent deformation space and decodes sampled latent codes into local stationary velocity fields conditioned on an input anatomy. Local fields are assembled into coherent full-volume transformations, enabling memory-scalable generation for large field-of-view CT data. We validate the approach on respiratory 4DCT data with multiple breathing-phase anatomies per subject. SynthRCT enables patient-specific sampling of plausible anatomical transformations beyond predefined robustness scenarios. Code available at: https://github.com/TomasGuija/SynthRCT.

0.45

CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

cs.CV physics.med-ph ·2026-11-10 ·Luuk Jacobs, Pietro Dirix, Sebastian Kozerke
similarity 0.65
Abstract · Under review

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.

0.17

TomoTransformer: Towards a Foundation Model for CT Reconstruction

cs.CV cs.LG ·2026-09-29 ·AmirEhsan Khorashadizadeh, Benjamín Béjar
benchmark similarity 0.64
Abstract

Supervised deep learning has advanced sparse-view tomographic reconstruction. However, conventional models, which typically map filtered back-projection (FBP) images or sinograms to clean reconstructions, are brittle under distribution shifts. Because they require retraining whenever projection counts and angles, detector resolutions, or data distributions change, their deployment in real-world applications remains limited. To address this, we introduce TomoTransformer, a transformer-based architecture that treats each \textit{local} filtered projection as an individual token and predicts missing views via self-attention. Crucially, TomoTransformer operates in a \emph{back-projection space} that separates projections across spatial locations, making view interpolation geometrically well-posed and invariant to detector size. This design yields a single foundation model that can process any number of input projections, at arbitrary angular locations and detector dimensions, and query any number of target angles without retraining. Trained on a large-scale dataset spanning diverse medical CT anatomies and natural images, TomoTransformer generalizes effectively across anatomies, materials, and resolutions. Extensive evaluations on several benchmark sparse-view datasets show that TomoTransformer significantly outperforms concurrent multi-purpose models like ViewTrans and matches or exceeds strong protocol-specific baselines, while remaining fully agnostic to the number of input and target projections. Furthermore, the model demonstrates robust zero-shot generalization on real experimental nanoscale brain data collected from an X-ray synchrotron, showcasing its practical utility for real-world applications.

0.19