Which Vertebral Landmark Errors Change a Cobb Angle? Geometry-Weighted Supervision for Radiographic Landmark Regression

Zizhao Peng

eess.IV cs.CV ·submitted 2026-11-19 20:52 UTC · v1

Abstract

A network that localizes vertebral corners can reduce pixel error while rotating the line used to measure spinal curvature. We derive a training loss from the geometry of a three-angle reader. Of the eight corner-displacement degrees of freedom of a vertebral quadrilateral, one local direction rotates its left-to-right chord. The angular sensitivity in this direction is inversely proportional to chord width. An orthonormal Hadamard basis lets us give this residual extra weight during training while retaining supervision on the other seven directions. In five-fold image-level development experiments on 372 anteroposterior radiographs, we compared three objectives across 45 fits of the same landmark network. The three-seed corner ensemble reduced pooled symmetric percentage error from 18.45% with coordinate supervision to 17.20% with geometry weighting. Adding a soft pairwise-angle term yielded 16.89%, a paired difference of $-1.56$ percentage points from coordinate supervision (95% image-bootstrap interval $[-2.51,-0.61]$). The interval for the increment from adding the soft term included zero. In a single-fold comparison, direct unit-chord supervision also reduced error, and its difference from geometry weighting was uncertain. Across single-seed runs, rotational residual error fell by 36.1% while normalized corner error rose from 2.60% to 2.71%. Perturbing one vertebra at a time also showed when a small rotation changes the selected end pair. These results identify a measurable trade-off between landmark fidelity and agreement with a specified geometric reader. The evaluation concerns an internal image-level split and landmark-derived target angles.

Comment
13 pages, 7 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Dense Representation Learning and Differentiable Shape Modeling for Spine Landmark Detection

cs.CV cs.AI ·2026-10-27 ·Augustin Daridon, Sofiane Sifaoui, Ayman Assi, Mohamad Karam, Wafa Skalli +2 more
code/data similarity 0.61
Abstract

Spine landmark detection from spinal X-ray is a key step for estimating spine deformation severity, for building biomechanical models, and for pre-operative planning. We reframe anatomical landmark detection as a pixel-level contrastive representation learning problem, matching dense pixel embeddings with landmark prototypes. Surprisingly, even with a generic U-Net backbone, this formulation results in more discriminative heatmaps compared to the traditional heatmap regression paradigm, leading to improved discrimination between vertebral corners on distinct vertebra. Furthermore, we combine the resulting heatmaps with learnable shape priors over the global configuration of spinal landmarks to resolve ambiguities in landmark locations, yielding a simple and practical approach to spinal landmark detection. Our approach is competitive, in terms of landmark accuracy and clinical parameter estimation, with the state-of-the-art on the public AASCE dataset and on two private spinal X-ray datasets. Our code and pre-trained weights are available at https://github.com/BioMedTP/Pix2Point.

0.33

Anatomy-aware cross-speaker adaptation of complete vocal-tract acoustic-to-articulatory inversion

eess.AS cs.AI ·2026-09-24 ·Nhat-Nam Nguyen, Pierre-Andre Vuissoz, Yves Laprie
similarity 0.60
Abstract · Submitted to IEEE ICASSP 2027

Cross-speaker acoustic-to-articulatory inversion requires accounting for anatomical differences between speakers. We propose a geometric adaptation framework that uses anatomical landmarks, primarily on vertebrae and dental structures,to transfer predictions from a fixed inversion model to unseen speakers. An affine transformation followed by thin-plate spline (TPS) deformation maps the predicted contours of 10 vocal-tract structures into each target speaker's geometry without retraining. Landmarks are identified in one selected /u/ frame per speaker as a common phonetic reference without assuming identical articulatory configurations across speakers, and the resulting mapping is reused across recordings. We train the model on a single-speaker rt-MRI database and evaluate adaptation on eight speakers from a separate multi-speaker rt-MRI database. We compare affine and TPS configurations using 12 or 14 landmarks. Affine12+TPS14 achieves the lowest mean point-to-closest-point error of 3.19mm. These results support the combined value of anatomical landmark information and nonrigid alignment.

0.30

Learning Where to Trust: Reliability-Guided Expert Routing and Velocity Gating for 3D Deformable Registration

cs.AI cs.CV ·2026-10-27 ·Chenyu Guo, Wenjie Dai, Yiqian Chang, Zhiyuan Zhang, Yunfan Wei +4 more
hot direction similarity 0.54
Abstract

Deformable image registration relies on accurate anatomical correspondences. However, explicitly coupling local matching reliability with spatial context selection and deformation update strength remains insufficiently explored in learning-based registration. This challenge is particularly pronounced in homogeneous, weakly textured, and severely deformed regions, where ambiguous matches may induce erroneous deformation updates. We propose ReliMorph, a reliability-routed symmetric framework for 3D deformable registration that couples correspondence assessment with spatial context selection and update strength.Local correlation distributions characterize correspondence ambiguity using shared anatomical features with modality-specific adaptation. These reliability cues guide spatial expert fusion and gate residual velocities during coarse-to-fine refinement. Updated inverse-inconsistency feedback guides routing and gating at finer pyramid levels. To our knowledge, ReliMorph is the first 3D deformable registration framework to jointly condition spatial expert routing and residual velocity gating on correspondence reliability. Extensive experiments demonstrate that ReliMorph consistently outperforms competing methods in anatomical overlap, highlighting its effectiveness across unimodal and multimodal registration tasks.

0.20

LM-PCVMNet: Pediatric Cervical Vertebral Maturation Analysis with Deep Fusion of Landmarks and Metadata

eess.IV cs.CV ·2026-09-11 ·Peng Wang, Wanzhen Song, Anli Wang, Xueshuo Xie, Xiaohang Guan +1 more
publishedcode/data similarity 0.53
Abstract · 12 pages accepted by Information Fusion

Cervical vertebral maturation (CVM) assessment plays a pivotal role in orthodontic diagnosis and determining the optimal timing of treatment, especially for pediatric patients. In this paper, we propose LM-PCVMNet, a novel deep learning framework for automatic pediatric CVM staging. Specifically, our method integrates vertebral anatomical landmark information, heatmap-guided feature modulation, and metadata-informed similarity modeling into a unified learning framework. We introduce a heatmap-guided feature modulation module that enhances feature extraction by leveraging landmark-centered heatmaps to highlight morphologically relevant vertebral regions. A vertebral landmark-prompting block is designed to incorporate anatomical geometry into the representation learning process. Furthermore, we develop a learnable metadata supervised contrastive loss that adaptively modulates positive-pair similarity based on metadata similarity, enabling the model to learn more biologically consistent and discriminative features. To facilitate further research in pediatric orthodontic treatment, we additionally release PCVM+. It contains 1800 lateral cephalometric radiographs from real-world patients aged 3-15 years, with expert-annotated CVM stages, 13 vertebral anatomical landmarks, and corresponding metadata. We perform comprehensive experiments on two datasets, and the results show that our method achieves state-of-the-art performance, effectively improving landmark localization and classification accuracy over existing models. Code and dataset will be available at github.com/ybupengwang/LM-PCVMNet.

0.63

Automatic Cephalometric Landmark Localization on CBCT-Derived Digitally Reconstructed Radiographs for Skeletal Malocclusion Classification

cs.CV ·2026-08-17 ·Benjamin Hou, Konstantinia Almpani, Janice S. Lee, Zhiyong Lu
published similarity 0.53
Abstract · Accepted for presentation at the ODIN 2026 Workshop, held in conjunction with MICCAI 2026

Manual cephalometric landmark annotation is important for craniofacial assessment but is labor-intensive and difficult to scale. We introduce CephViT, a Vision Transformer-based model for automated 2D lateral cephalometric landmark localization, and evaluate its use in downstream skeletal malocclusion classification. CephViT was trained and benchmarked on a public lateral cephalogram dataset, achieving a mean radial error of 1.28 +/- 1.42 mm and a successful detection rate of 92.0% at 3.0 mm. Because the private evaluation cohort consisted of 3D CBCT scans, lateral cephalogram-like digitally reconstructed radiographs (DRRs) were generated from each volume and used as 2D inputs to the landmark localization model. Landmark coordinates were normalized into a common coordinate frame, and skeletal malocclusion classification was performed using landmarks shared between the reference and DRR-based pipelines. Classification performance using DRR-localized landmarks was comparable to that obtained using manually annotated reference landmarks, with accuracies of 70.0% and 68.3%, respectively. These results support the feasibility of automated cephalometric analysis on CBCT-derived DRRs for skeletal malocclusion assessment.

0.35

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

cs.CV ·2026-09-24 ·Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
similarity 0.53
Abstract · 23 pages, 4 figures, 19 tables

Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatially coherent geometric discrepancies that act as structured label noise. We investigate how this registration-induced bias affects supervised MRI-to-CT and CBCT-to-CT synthesis on 1,784 paired patients covering five anatomical regions. Voxel-wise scores strongly depend on the consistency between the registration used to build the training targets and the one used for evaluation: models score best when both conventions match, showing that networks partly learn the geometric convention of the registration pipeline and that standard metrics reward it. Training on more anatomically consistent registrations reduces prediction variability and improves out-of-distribution robustness, and CT-only controls show that registration alone produces metric errors in the range of top challenge submissions. To mitigate the limits of voxel-wise supervision, we introduce a perceptual loss computed in the feature space of a pretrained Segment Anything encoder. Compared with MAE-only and VGG-based objectives, it improves downstream segmentation and yields sharper, more structurally coherent sCT. Perceptual and voxel-wise metrics disagree under imperfect alignment and agree when the evaluation geometry is reliable. These results identify registration-induced bias as a central confounder in supervised sCT generation and argue for complementing voxel-wise agreement with anatomy-oriented evaluation criteria.

0.27

ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT

cs.CV ·2026-11-18 ·Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong +3 more
similarity 0.53
Abstract

Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.

0.27

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.52
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42