CS Paper Radar

Controlled One-Click Benchmarking and Post-Fusion Recalibration for Support-Conditioned Medical Segmentation

Wang-Chi-Shiun, Wei-Huan Hu, Liu-En-Chi, Liu Zhi Shun, ChengYi Peng, Shin-Jye Lee

cs.CV ·submitted 2026-11-21 16:11 UTC · v1
top venue

Abstract

Sparse-prompt medical segmentation is hard to compare when prompts, supports, thresholds, and splits differ. This paper uses a controlled one-click protocol: each test image receives one positive foreground click, training-only support, validation-only checkpoint selection, and no test-time threshold tuning. We propose {Support-Aware Recalibration (SAR)}, a late post-fusion recalibration block for MultiverSeg that combines large-kernel spatial gating with squeeze-and-excitation channel recalibration after support--query fusion. BUSI, NerveUS-BP-present, and Kvasir-SEG are evaluated with matched 697 foreground-present sample budgets, shared splits/clicks, and threshold-free Dice-AUC/IoU-AUC. Compared with a protocol-matched raw-support MultiverSeg baseline, the main SAR configuration shows favorable mean Dice-AUC/IoU-AUC performance on BUSI, NerveUS-BP-present, and Kvasir-SEG, while reducing logged training time in this implementation. These controlled results indicate that late post-fusion recalibration is useful under a leakage-controlled one-click protocol.

Comment
Accepted at the European Conference on Computer Vision (ECCV 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

When Fusion Fails: Corruption-Aware Rebalanced Fusion for Multi-Modal Medical Image Segmentation

cs.CV ·2026-09-09 ·Yuchen Pei, Xiaoyu Hu, Yixiong Zou, Dingwen Hu, Hui Chu +3 more
top venuecode/data similarity 0.64
Abstract · Accepted by ACM Multimedia (ACM MM 2026)

Multi-modal medical image segmentation leverages complementary diagnostic information, yet fusion can underperform single-modality baselines when spatially aligned inputs differ in quality. Here, "corruption" primarily denotes resolution-induced degradation rather than misalignment or complete modality absence, while synthetic noise is evaluated only as an auxiliary setting. We identify a critical optimization-inference inconsistency: degraded modalities can receive weak training updates yet substantially affect predictions, indicating active interference with fusion. We attribute this failure to resampling-induced feature corruption and optimization bias, where noisy features propagate through skip connections and encourage unreliable modality selection. We therefore propose CoReFuse-Med, a Corruption-aware Rebalanced Fusion framework that suppresses corruption during feature transmission and rebalances modality contributions during high-level fusion. Experiments on EPVS, BraTS, and WMH, including multiple Z-axis slice-retention ratios and an auxiliary noise test, demonstrate improved accuracy and robustness under modality-quality discrepancies. Our code is available at https://github.com/lrever/CoReFuse.

0.53

LightMIS: Ultra-Lightweight Medical Image Segmentation Without a Stage-Wise Decoder

cs.CV ·2026-09-23 ·Andrei Arhire, Mihaela-Elena Breabăn, Radu Timofte
code/data similarity 0.63
Abstract

We present LightMIS, a scalable family of ultra-lightweight convolutional networks for 2D binary medical image segmentation without a learned stage-wise decoder. LightMIS aligns the outputs of a five-level encoder to a common resolution using Scale-Aligned Projection blocks, aggregates them once, and refines the fused representation with an Adaptive Fusion Cascade. The cascade combines Adaptive Kernel Fusion with the proposed Progressive Receptive Fusion module, which uses temporary channel expansion, complementary depthwise receptive fields, and progressive cross-branch information transfer. We evaluate LightMIS-T, LightMIS-S, and LightMIS using five-fold cross-validation under a common nnU-Net v2.3.1 protocol on DRIVE, Kvasir-SEG, DSB18, BUSI, ISIC-2017, and ISIC-2018. Full LightMIS contains 0.131 M parameters and requires 0.575 GFLOPs for a $3\times256\times256$ input, achieving modality-macro Dice and IoU scores of 86.71% and 78.99%, respectively. Mobile U-ViT obtains 86.75% Dice and 79.07% IoU, so the observed differences are 0.04 and 0.08 percentage points. Relative to Mobile U-ViT, nnWNet, and nnU-Net, LightMIS reduces parameter count by 90.58$-$99.61% and GFLOPs by 82.54$-$96.14%. On an Arm Mali-G52 MC2 GPU, all LightMIS variants achieve full GPU delegation, with median delegated latency ranging from 53.31 ms for LightMIS-T to 138.31 ms for LightMIS. These results demonstrate a favorable accuracy-complexity trade-off and on-device execution feasibility for the evaluated tasks. The code is publicly available at https://github.com/AndreiiArhire/LightMIS.

0.32

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.62
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

MedSegBenchmarker: A Raw-Count-First Framework for Controlled 2D Medical Image Segmentation Benchmarks

cs.CV cs.AI ·2026-08-30 ·Vanessa Borst, Lukas Horn, Daniel Grillmeyer, Thomas Prantl, Samuel Kounev
benchmark similarity 0.62
Abstract · 10 pages, 4 figures;

Despite rapid advances in MIS, fair and reproducible comparisons of segmentation models remain challenging due to heterogeneous datasets, inconsistent evaluation protocols, and rapidly evolving architectures. In particular, comparisons often implicitly assume that model rankings are invariant to data partitioning, preprocessing, metric aggregation, uncertainty estimation, and computational constraints. The lack of extensible and unified evaluation frameworks further limits systematic investigation of new models, datasets, and training paradigms. We present MEDSEGBENCHMARKER (MSB), a configuration-driven framework for controlled benchmarking of 2D MIS. It integrates duplicate and near-duplicate image detection, group-aware data splitting, YAML study specifications, resumable training, hyperparameter optimization, cross-validation, and checkpoint-based evaluation. Rather than retaining only aggregate performance measures, MSB exports sample- and class-level pixel counts and predictions together with the evaluation context. These elementary artifacts enable post-hoc analyses without repeated inference. We demonstrate MSB in a case study involving three heterogeneous 2D datasets and multiple MIS and general-purpose vision models evaluated at 256- and 512-pixel input resolutions. Reaggregation of identical predictions changes the top-ranked architecture in three of six dataset-resolution settings, despite high rank correlations between aggregation strategies. Increasing input resolution produces model- and dataset-dependent performance gains and losses that must be considered alongside empirically measured inference complexity. These results show that seemingly minor choices in evaluation and experimental setup can affect benchmark conclusions. MSB, available at GitHub, provides a practical and extensible basis for making benchmark conditions and evaluation choices explicit and reproducible.

0.45

Adaptive Post-Processing Drives Instance-Level Detection in Stroke Lesion Segmentation

cs.CV cs.AI ·2026-08-17 ·Qinghui Liu, Jon André Ottesen, Atle Bjørnerud, Kyrre Eeg Emblem
published similarity 0.62
Abstract · 8 papges, 4 figs, 2 tables, MICCAI ISLES'26

Instance-level lesion detection has been an increasingly larger focal point in medical image segmentation besides the more standard voxel-level overlap. Still, most pipelines are trained and post-processed for voxel overlap alone. In particular, the mismatch is most pronounced for small lesions, where a near-miss prediction---substantial overlap that falls just short of the instance-matching threshold---scores the same as a complete miss. In our ISLES'26 submission, we found that closing this gap mattered far more in post-processing than in architecture design. Our Volume-Conditioned Adaptive Post-Processing (VCAP) scheme adjusts component-size thresholds to each case's predicted lesion burden, improving Lesion-F1 by 0.032 (unbiased cross-fold estimate)---approximately 6 times larger than any architectural change we tested. A resolution-aware attention architecture (Viola2Plus), designed for small-lesion segmentation, shows why the distinction matters: it left small-lesion Dice unchanged but raised small-lesion detection rate by 3.7\%, a real effect voxel-overlap metrics alone would have missed. Under 5-fold cross-validation on the 1,453-case training set, our post-processed two-architecture ensemble achieves Dice 0.651 and Lesion-F1 0.614, versus 0.644 and 0.573 for the unprocessed single-model baseline.

0.44

Pre- and Post-Treatment Brain Metastases Segmentation Using nnU-Net with Post-Processing for BraTS 2026

cs.CV ·2026-09-10 ·Haobin Liu, Xin Wang
publishedbenchmarkcode/data similarity 0.61
Abstract · Accepted to MICCAI 2026 Challenge BraTS-METS

Brain metastases exhibit high inter-lesion variability in size, enhancement pattern, and post-treatment appearance, making volumetric segmentation of both pre- and post-treatment cases the central challenge of the BraTS 2026 Task 1 (Brain Metastases). We build a pragmatic pipeline on a 5-fold nnU-Net ResEnc-L ensemble, in which each fold is trained independently for 1,000 epochs with the standard Dice + cross-entropy loss on 1,296 four-modality training cases. This ensemble is followed by a rule-based post-processing cascade tuned for the lesion-wise Dice similarity coefficient (LW-DSC), a detection-oriented metric that behaves very differently from the traditional global Dice. The final pipeline reaches an LW-DSC of 0.733 / 0.751 / 0.713 / 0.549 on the enhancing tumour (ET), tumour core (TC), whole tumour (WT), and resection cavity (RC) sub-regions on the official validation leaderboard. Rather than trusting these leaderboard gains, we audit every post-processing stage with a five-fold out-of-fold (OOF) analysis with no model-training leakage over all 1,296 training cases, scored with the official BraTS evaluation code (BraTS_evaluation): it confirms two stages as robust, per-fold-consistent improvements while the third improves only the leaderboard and does not reproduce out-of-fold. We further provide a mechanistic analysis of the LW-DSC metric that explains why recall-recovering post-processing carries low risk whereas component deletion does not, and we report thirteen negative results spanning loss engineering, alternative backbones, and inference-time settings, several of which run counter to widely held intuitions. Source code is released under Apache-2.0 at https://github.com/hornbeamliu/brats2026-met.

0.48

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.61
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.17

Different Models, Shared Failures: Auditing Frozen-Encoder Pools for Medical Segmentation

cs.CV cs.AI ·2026-10-30 ·Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim
top venuecode/datahot direction similarity 0.60
Abstract · Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 47 pages, 8 figures. Code and data: https://github.com/eunseobchoi/CoFailMed

Average segmentation accuracy and model count do not reveal whether models fail on the same cases. We present CoFailMed, an audit of correlated failures in pretrained-encoder pools for medical segmentation. Across five 2D tasks, we evaluate 11 public pretrained encoders (a controlled sample, not a census) using frozen features and separately trained $1\times 1$ readouts with four seeds per encoder. Shared-checkpoint pairs have the highest mean per-case Dice correlation. An expanded 17-encoder analysis shows that distinct checkpoints within the same encoder family remain more correlated than cross-family pairs. At the pooled 33rd-percentile Dice threshold, four-member pools drawn from distinct encoders have mean effective sizes of 1.56-2.92, estimated from failure correlations in pools with enough failures and passes per member. In the primary pool, richer readouts and fine-tuning narrow the Dice-correlation gap between pairs sharing a checkpoint (or the DINOv2-B/S release) and all other pairs. Yet dependence between different encoders can increase, and fine-tuning does not consistently increase effective pool size at 33rd-percentile thresholds recomputed for each training recipe. A smaller between-group gap can coexist with greater dependence. Pool evaluation should therefore report absolute dependence and threshold-specific effective size alongside accuracy and nominal pool size. The CoFailMed release provides aligned per-case traces, analysis scripts and study code to reproduce the central audit results.

0.63