CS Paper Radar

Who Gets Re-ranked When a Clinical Model Gains New Data?

Priyanka Siddappa, Muntaqim Ahmed Raju, Shifat Haider Al Amin, Ruizhe Ma

cs.IR cs.AI ·submitted 2026-11-21 18:05 UTC · v1
unusual

Abstract

Hospitals often update a deployed risk model by adding a data source, such as laboratory results, that only some patients have. Work on safe model updates assumes fixed inputs and so ignores patients who lack the new data. The update has no new measurements for them, yet their rank can change, and a sick patient not yet tested can drop off an alert list. We split rank-based compatibility by data availability and pair it with error correction and alert-list effects. We compared each update with ordinary retraining on the old inputs, predicting ICU admission or death and hospital admission, on 78,475 emergency department visits from MC-MED and, in a pre-registered replication, 100,000 stays from MIMIC-IV-ED at a second hospital. Radiograph report text gave no detectable gain and almost no extra re-ranking. Laboratory results improved prediction but, at both hospitals and with linear or tree models, pushed patients without labs down alert lists; linear updates also reshuffled them more than retraining did, without ranking them better. A top-20% admission list caught 4.2% of admitted patients without labs after the update, against 18.8% after retraining (second hospital: 4.9% against 22.6%), while catching more patients overall. This held for list sizes from 5% to 50% and in every patient group we checked, despite better measured calibration. Separate alert thresholds for patients with and without labs restored most or all of their catch rate at both hospitals at almost no cost. Teams should check these patients before deploying such an update.

Comment
Accepted at the 6th International Workshop on Multi-Modal Medical Data Analysis (MMMDA), IEEE BigData 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Alert-List Concordance for Evaluating Imputation Strategies in ICU Sepsis Prediction

cs.LG q-bio.QM ·2026-10-15 ·Priyanka Siddappa, Muntaqim Ahmed Raju, Shifat Haider Al Amin, Ruizhe Ma
published similarity 0.58
Abstract · 8 pages, 2 figures. Accepted at the 14th Workshop on Data Mining in Biomedical Informatics and Healthcare (DMBIH 2026), held in conjunction …

Preprocessing is an under-measured reliability risk in clinical prediction: a model can keep a similar AUROC and still change who receives an alert. Imputation quality is commonly evaluated using reconstruction error or aggregate discrimination, neither of which directly measures agreement on which patients are flagged. At a matched alert rate, pipelines with similar aggregate performance can produce different patient lists. This question is especially relevant under the frequent, structured missingness of real ICU records. We therefore introduce alert-list concordance, which asks whether two pipelines identify the same high-risk patients, measured by the Jaccard similarity of their top-k% alert sets with patient-level bootstrap confidence intervals. On PhysioNet/CinC 2019 (40,336 patients, 71.9% missingness), we compare nine imputation strategies and a native-missingness baseline using a fixed XGBoost configuration, fitted and Platt-calibrated separately for each strategy. After Bonferroni correction, 22 of the 28 reconstruction-method pairs showed no statistically significant difference in patient-level AUROC, yet their alert lists overlap at Jaccard 0.518 to 0.750. Similar aggregate discrimination can therefore accompany different patient selections. ForwardFill is a separate outlier, pairing higher discrimination with the lowest overlap in the matrix, 0.40 to 0.45. The broad pattern holds within each hospital system and under six patient-level aggregation rules. At the row level, eight of ten methods fall within an AUROC range of 0.011. In this row-level pipeline, deep imputers did not outperform mean imputation on discrimination, and the sequential implementations cost 5 to 12 times mean imputation in total pipeline wall-clock time on our hardware.

0.54

Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift Detection

cs.LG cs.AI ·2026-10-13 ·Olivier Lefebvre, Hakima Laribi, Dan Poenaru, Martin Vallières
publishedcode/data similarity 0.57
Abstract · Accepted at SMASH (Symposium on Machine Learning and Applications in Healthcare) 2026. Code available at https://github.com/MEDomicsLab/stud…

Before deploying clinical prediction models, their reliability must be assessed to ensure safe use. Errors may arise from distribution shifts between training and deployment or from heterogeneous performance where the model systematically underperforms for certain patient subgroups. Yet most post-hoc diagnostic methods evaluate reliability only at the population level, checking whether the deployment data resemble the training data and whether the model performs well on average, without accounting for heterogeneity that may cause some patients to be disproportionately affected. We propose a unified diagnostic pipeline that combines both perspectives. MED3pa first discovers interpretable low-confidence patient profiles, and Detectron is then applied within each profile to test whether its degradation is associated with a detectable harmful covariate shift. Across three clinical prediction tasks and three injected subgroup shifts in MIMIC-IV, we find that shift detectability itself is informative. An injected age shift, undetectable at the population level, was nonetheless localized to specific degraded profiles, whereas sex- and race-related shifts were detected broadly and therefore offered little guidance for identifying the most affected patients.

0.47

When Copying Is Hard to Beat: A Negative Result in Clinical Assessment Forecasting

cs.LG ·2026-11-13 ·Marius Fracarolli, Stefan Riezler
published similarity 0.57
Abstract · Accepted at FMTS (Foundation Models for Temporal Systems), a workshop at NeurIPS 2026, Sydney

We report a negative result in next-day clinical assessment forecasting: the evaluated models show no consistent advantage over strong persistence-based baselines. Clinicians can view the previous day's questionnaire answers, a plausible source of documentation persistence. Predicting 45 items on 29,715 ICU day-pairs with patient-disjoint splits, a physiology-informed gated model improves item-macro-F1 over a one-line clinical rule by +0.0019 [+0.0006,+0.0031], while losing accuracy. No macro-F1 advantage is established when the physiology window ends at the previous form's reference time (+0.0001 [-0.0006,+0.0008]), or when scoring excludes the 68.5% of cells derived from parent answers; combining both changes yields a small disadvantage. Four checkpoints across three families underperform persistence, and a fine-tuned one differs from it on only two cells. A categorical read-out raises changed-cell accuracy eightfold, but a state-only read-out scores higher overall than forecast-only decoding and matches a transition matrix. This negative result highlights how the documentation process, input cutoff, observation mask and decoding rule shape conclusions about forecasting recorded assessments.

0.34

When to Trust Simulated Patient Responses:Support-Gated World Models for Vasopressor Decision Support

cs.AI ·2026-11-13 ·Yifan Jin, Tao Liu
similarity 0.57
Abstract

Clinical world models expose language-model agents to predicted patient responses, but simulations can be unreliable for poorly supported treatments or unfamiliar hospitals. We introduce Support-Gated World-Model decision support, a lightweight extension of a propose--simulate--refine agent. A recurrent dynamics ensemble predicts short-horizon physiological responses to documented norepinephrine dose categories, while a behavior model estimates observational action support. The interface withholds predictions with insufficient support or excessive ensemble disagreement and abstains when no candidate qualifies. Evaluation on eICU-CRD includes 70 hospitals and 30,700 decision transitions, with 14 hospitals held out for testing. At 62.0% factual-transition coverage, joint gating yields a MAP mean absolute error of 7.3 mmHg, compared with 9.2 mmHg for random selection at the same coverage. The gated agent achieves 60.0% agreement with recorded actions at 81.0% decision coverage, compared with 55.0% agreement and 99.5% coverage for an ungated ensemble agent. Component ablations show lower factual risk with joint gating than with either gate alone.These results characterize a reliability--coverage trade-off in selective clinical simulation; they do not identify individualized treatment effects or establish improved patient outcomes.

0.15

R-GEAN: Regimen-Guided Edit Action Network for Within-Admission Medication Change Prediction

cs.AI cs.IRcs.LG ·2026-09-19 ·Regan Mahat, Mansu Kim
benchmark similarity 0.56
Abstract

The medications prescribed to a patient often change during a hospital admission as clinicians start, stop, or continue therapies. We study whether models can predict which medication classes are added or removed between 24 hours after admission and discharge. Metrics that compare the complete discharge regimen can reward models for copying medications that remain unchanged, even when they identify no actual changes. We therefore introduce a leakage-controlled benchmark that predicts net ATC3 additions and removals using only prior completed admissions and information available within the first 24 hours of the current admission. Addition candidates are classes not active at 24 hours, whereas removal candidates are classes active at that time. We also introduce R-GEAN, an asymmetric candidate-scoring network with independent addition and removal predictors. Across 240,480 admissions from 82,286 patients, R-GEAN achieves the highest predefined summary of addition, removal, changed-regimen, and action-pattern performance, termed the edit composite (0.464), compared with 0.435 for the strongest primary comparator. Reimplemented RETAIN, GAMENet, and MICRON baselines obtain 0.428, 0.420, and 0.288, respectively. R-GEAN's advantage is concentrated in correctly identifying medication classes no longer active at discharge, while rare additions and admissions with multiple medication changes remain difficult. Rankings based on micro-F1 over the reconstructed discharge regimen and the edit composite correlate weakly across the evaluated models (Spearman r = 0.20). The continuation baseline achieves the highest complete-regimen score despite predicting no additions or removals. These results show that complete-regimen and edit-level evaluation measure different aspects of medication prediction. The benchmark evaluates observed prescribing changes, not treatment appropriateness

0.30

Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification

cs.LG cs.CV ·2026-11-05 ·Dang-Khoa Bui, Quang-Huy Tran, Minh-Khoi Nguyen-Bui, Duc-Tuan Ngo, Thanh-Trong Tran +2 more
benchmark similarity 0.56
Abstract · 10 pages, 1 figure, 6 tables

Benchmarks of class-imbalance strategies for multimodal chest X-ray (CXR) and electronic health record (EHR) prediction are often evaluated on record-level splits of cohorts in which one patient contributes several radiographs. We audit such a benchmark on 29,083 MIMIC-CXR radiographs of 10,479 patients with eight diagnosis targets. First, the record-split benchmark was misleading: a lookup table that copies the label of a development-set radiograph with the same EHR vector nearly matched the best model, and on unseen patients every model fell to the level of predicting every case positive. Second, tracing the labels back to MIMIC-IV explained why: each patient's labels are keyword matches on the diagnosis codes of a single admission, copied, with one EHR vector per patient, to all of the patient's radiographs, so about a third of the radiographs carry labels that differ from the codes of their own admission. Third, under patient-separated evaluation with admission-aligned and rule-refined labels, the initial conclusions do not hold: in the evaluated configurations no imbalance strategy raised the observed mean macro F2 over no augmentation by more than 0.01, tuned tree ensembles showed no consistent advantage over tuned logistic regression, and the released EHR variables stayed at the level of the all-positive baseline, whereas the diagnostic history available at imaging time and image embeddings exceeded it, including, with rule-refined labels, a CheXpert-trained encoder that never saw these radiographs; RAD-DINO had seen 96.6% of them during self-supervised pretraining. Adding either encoder to the diagnostic history gave no statistically significant F2 gain; exploratory AUROC gains were significant with RAD-DINO but not with DenseNet. We provide reusable diagnostics, a leakage-aware protocol and a checklist.

0.22

MedJev: Evaluating Zero-Shot System-One Decision Making in Medicine

cs.CL cs.AIcs.LG ·2026-10-26 ·Simon A. Lee, Jiahang Sha, Moonseong Jeong, Yunbei Pan, Jeffrey N. Chiang
similarity 0.56
Abstract

System One decision models such as Jev answer structured questions in a single forward pass without generating text, offering fast and computationally efficient clinical decision support. We evaluate MedJev, an open System One model that runs locally on a laptop, across ten medical benchmarks spanning medical knowledge, diagnosis, and patient level prediction using MIMIC IV and MIMIC IV ED. We compare MedJev against zero shot LLM baselines, published GPT results, and supervised models. MedJev achieves accuracies of 72.5 percent on MedQA, 75.4 percent on USMLE, and 80.1 percent on NEJM, approaching published GPT 4 performance while maintaining well calibrated confidence estimates (ECE 0.028 to 0.063). On patient level tasks, MedJev achieves an AUROC of 0.926 for In Hospital Mortality, exceeding XGBoost (0.902), but underperforms supervised models on operational outcomes such as ED Triage Admission (0.745 vs. 0.809). Patient level predictions also exhibit substantial miscalibration (In Hospital Mortality ECE 0.286). We introduce a lightweight, two parameter recalibration method that adapts predictions to local patient populations using 50 to 200 labeled examples, reducing ECE to 0.007. Our findings establish open System One models as a promising zero shot baseline for medical AI, combining competitive predictive performance with low computational cost and efficient local calibration. We release our code and evaluation harness to support future research.

0.24

Emergency Department Revisit Quality Review Screening: Exploring Human Decision-Making and Artificial Intelligence Support

cs.CY cs.AI ·2026-09-09 ·Jonathan A. Handler, Marlene I. Robles-Granda, Jacob E. Mefford, Jeremy S. McGarvey, Gregory S. Podolej +3 more
similarity 0.55
Abstract · 12 pages, 1 figure

Background: Emergency Department (ED) return visits are commonly reviewed for quality assurance, but are often limited (e.g., to revisits within 48-72 hours) to increase actionable finding yield while minimizing chart review burden. Those limitations may lead to missed quality improvement opportunities. Methods: We conducted an exploratory, retrospective study of randomly selected ED visits to a multihospital health system having an ED revisit within 1-14 days to the same health system. Given only each visit's primary diagnosis, raters (2-3 clinicians and GPT-4 large language model [LLM]) assessed characteristics of the diagnosis pairs, including the "target": whether a pair warranted further assessment. Informed by rater response analyses, an algorithm leveraging an LLM-populated knowledge graph ("KGA") was created to automatically screen for potentially concerning pairs, then preliminarily assessed. Results: 99 diagnosis pairs were included. GPT-4 responses poorly correlated to clinician raters, rating nearly all (94%) pairs as warranting follow-up (4.4-13.3 times more than clinicians). However, prompt engineering was minimal. Among clinician raters, revisit medical gravity was consistently significantly associated with the target, while a differential diagnosis/complication composite was significantly associated on unadjusted, but not adjusted (though less powered) analysis. The KGA achieved 83-100% positive predictive value for at least one clinician rater determining further assessment was warranted based on the diagnosis pair. Conclusion: These results can inform next steps for improving screening with LLMs like ChatGPT. Further research is warranted to validate this preliminary work's finding that the KGA may enable enhancing the scope and yield of screening without substantially increasing reviewer workload.

0.26