CS Paper Radar

Foundation Model and Radiomics Distance Scores for Post-Hoc Segmentation Failure Detection

Simon Johannes Joham, Gianluca Guglielmo, Mateusz Kozinski, Martin Urschler

cs.CV ·submitted 2026-11-23 12:24 UTC · v1
publishedcode/data

Abstract

Medical image segmentation models can fail silently when clinical data differs from training data. Deployed models rarely ship with quality control, and are often black boxes. Prior methods that work in this post-hoc failure detection setting still need a separate regression or segmentation model, registration, or access to model internals. We instead propose two failure scores based on the Mahalanobis distance to a labeled reference set. The first uses radiomic shape features of the predicted mask. The second uses frozen foundation model (FM) features, made mask-aware by overlaying the mask on the image, encoding it with a frozen DINOv3, and pooling patch features with more weight on the mask region. We test on multi-site prostate and hippocampus MRI under imaging-protocol and population shift. Ranking cases by predicted failure risk within each site, both scores are competitive with the registration-based (Atlas-RCA) and ensemble-based (pairwise Dice) baselines, without registration that can fail silently or access to individual predictions. Our results show that pooling all test cases into one ranking, as prior work does, rewards ordering sites by difficulty, so a detector can rank sites well, miss failures within them, and still look strong. Within-site evaluation measures true per-case failure. The two evaluation schemes reward different behavior, so we recommend reporting both. The code is available at https://github.com/imigraz/fm-radiomics-failure-detection.

Comment
Accepted at the UNSURE MICCAI 2026 Workshop

Closest papers

Nearest neighbours by meaning across the whole index.

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.66
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15

SCOUT: Risk-Guided Foundation-Model Escalation for Robust Tissue Detection in Whole-Slide Images

cs.CV ·2026-11-18 ·Cristian Tommasino, Antonio M. Rinaldi
benchmarkcode/data similarity 0.65
Abstract

Reliable tissue detection is essential for whole-slide image analysis, yet high average segmentation accuracy can conceal failures involving pale tissue, small fragments, and heterogeneous staining. Pathology foundation models offer transferable representations, but exhaustive inference is computationally demanding and may introduce false-positive tissue predictions. We propose SCOUT (Selective Correction of Uncertain Tissue), a risk-guided cascade that selectively refines an initial thumbnail-based tissue mask. A lightweight audit network estimates the spatial distribution of segmentation errors and prioritizes candidate regions for processing by a frozen pathology foundation model. An asymmetric consensus rule integrates the resulting predictions with the initial mask to recover missed tissue while limiting false positives. A calibrated slide-level review score additionally controls the marginal rate of unflagged case-group failures under the calibration assumptions. Evaluation on a public multi-source, multi-stain benchmark shows that SCOUT reduces the proportion of case groups requiring mask correction from 38.1% for the best released detector to 18.6%, with particularly pronounced improvements in immunohistochemistry. Source-held-out experiments demonstrate better generalization than a segmentation network trained on the same annotations, while selective inference achieves an observed failure rate no higher than processing all candidate regions. Downstream, lymph-node classification with SCOUT masks is non-inferior to that obtained with two of the three released detectors evaluated. A variant built on an openly licensed foundation model is publicly released as an installable Python package with trained weights. These results support risk-guided foundation-model inference as an effective approach to tissue detection across heterogeneous histopathology data.

0.30

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.64
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.64
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.28

MID: Mask-Image Distributional Divergence for Evaluating Medical Image Segmentation

cs.CV cs.AI ·2026-10-12 ·Vincenzo Marcianò, Xiaoming Zhang, Gianluca Guglielmo, Michela Antonelli, Sebastien Ourselin +1 more
code/data similarity 0.64
Abstract

Current evaluation protocols for medical image segmentation remain largely anchored in sample-wise comparisons, e.g., Dice and Hausdorff distance, which require each prediction to be paired with a ground-truth mask. Yet two limitations arise in practice: they are inapplicable when predictions are made on unlabeled data; and even when annotations are available, they cannot assess whether a collection of predictions matches the distributional structure of the ground-truth population. We introduce MID (Mask-Image Distributional Divergence), a distribution-level evaluation metric for medical image segmentation. MID builds upon the observation that segmentation quality is a property of the joint image-mask distribution: a mask may be anatomically plausible in isolation yet incorrect for the image it accompanies. MID compares the joint distribution of images and masks between a reference set and a set of predictions, without requiring sample-wise correspondence. This captures both mask realism and image-mask consistency. We evaluate MID across 13 publicly available datasets spanning CT, MRI, and MRA. Under anatomically realistic corruptions across 56 organ groups, MID tracks mean Dice and Hausdorff distance without per-sample ground-truth pairing. MID also detects distributional shifts across modalities and anatomies, identifies image-mask misalignment through controlled shuffling experiments, and produces reliable model rankings across real segmentation models. Official implementation available at github.com/erc-caravel/pytorch-mid

0.28

DINO-Med: A Unified Patch-Based Adaptation Framework for Multi-Modal Medical Image Analysis Applied to Liver Fibrosis Staging

cs.CV ·2026-09-10 ·Boya Wang, Ruizhe Li, Chao Chen, Xin Chen
published similarity 0.64
Abstract · 12 pages, 2 figures. Accepted by AIiH

Adapting natural-image foundation models like DINOv3 to multi-modal medical imaging is challenging due to the significant domain gap between natural color images and multi-channel medical scans. We present a unified, patch-based framework that processes raw multimodal imaging through training-free registration, automated localization, and mask-filtered patch extraction. This architecture culminates in a hierarchical strategy that aggregates patch-level insights into subject-level diagnostics. Using liver fibrosis staging as a case study, we evaluate four patch-level feature representations: handcrafted Radiomics features, learned ResNet features, pre-trained foundation model SAM-Med2D features, and frozen DINOv3 features. To ensure a controlled comparison, all models utilize the same lightweight MLP head and are evaluated across both rigid and deformable registration settings. Our training protocol focuses on mild fibrosis (S1) and cirrhosis (S4) classes only, enabling a single classifier to address both substantial fibrosis detection and cirrhosis staging. Evaluated via 10 random train (90%)/ test (10%) splits on 360 subjects from the CARE 2025 Liver Track 4 cohort, our DINOv3-based framework significantly outperforms all baselines, achieving the best classification accuracy of 78.4% for S1 and 75.8% for S4.

0.43

CARD: Calibration via Agreement in Reverse Diffusion for Out-of-Domain MRI Segmentation

cs.CV ·2026-08-26 ·Jiaheng Dai, Weidong Guo, Qingbiao Li, Jie Xu, Yi Guo +2 more
similarity 0.63
Abstract · 10 pages, 5 figures

Probability calibration aligns model confidence with predictive accuracy, enabling clinicians to identify unreliable segmentation regions. This alignment breaks down under domain shift, where artifacts and unseen protocols produce confident errors. Existing post-hoc methods adapt the correction at test time, conditioning on predictive entropy, the logit pattern, or augmentation response, but each proxy is read from the terminal prediction, the very quantity that shift corrupts. This motivates reliability evidence beyond the terminal prediction, which categorical diffusion provides in two ways. First, a generative shape prior keeps a capacity-limited reference intact when appearance is corrupted, so its disagreement with the primary segmentor highlights primary-model errors. Second, every reverse step yields a class distribution, separating persistent disagreement from transient discrepancy. Aggregated over the trajectory, this disagreement correlates with Dice at 0.788, against 0.521 for a matched discriminative control. We therefore propose CARD (Calibration via Agreement in Reverse Diffusion), which maps the temporal aggregate of this disagreement to a temperature field applied per pixel across all classes, so that confidence changes while the segmentation does not. Across cardiac, prostate and brain MRI shifts, CARD lowers calibration error in 45 of 49 comparisons against the strongest baseline in each setting.

0.22

Reliability- and Anatomy-Consistency-Aware Multimodal Learning for Robust Fracture Classification from Bangladeshi Radiographs

eess.IV cs.AIcs.CV ·2026-08-21 ·Musa Tur Farazi, K G Subarno Bithi
hot direction similarity 0.63
Abstract

Background: Multimodal fracture classifiers may benefit from patient and anatomical metadata, but they can also become brittle when contextual information is missing or mismatched. Methods: We studied 1493 radiographs from the Bangladeshi OrthoFrac-XR dataset using leakage-safe age, sex, bone type, and laterality. A ConvNeXt image encoder was combined with a clinical multilayer perceptron through concatenation, late fusion, reliability-gated residual fusion, and a hierarchical state-location formulation. We additionally introduced an anatomy-consistency gate that attenuates metadata corrections when an image-side anatomical prediction disagrees with the reported bone type. Results: Across five folds and three seeds, hierarchical residual fusion achieved a macro-F1 of 0.6046 +/- 0.0279, compared with 0.5727 +/- 0.0270 for image-only learning, while improving the Brier score from 0.5239 to 0.4948. In a five-fold robustness experiment, anatomy-consistency fusion reduced the macro-F1 loss under shuffled metadata from 0.0567 to 0.0203 relative to ordinary residual fusion, although its clean-data macro-F1 was lower. Without bone type at inference, auxiliary anatomy supervision improved macro-F1 from 0.5620 +/- 0.0330 to 0.5899 +/- 0.0289. Conclusions: Structured context improves fracture classification, and consistency-aware gating limits harm from mismatched metadata. The observed clean-performance-robustness trade-off and the absence of patient-level identifiers motivate external and prospective validation.

0.34