CS Paper Radar

Closed-Form Formula for $d_{\mathrm{critical}}(a_0)$ in Large Fully Connected Power Grids

Sachin Kadloor

cs.NI math.PR ·submitted 2026-11-23 16:15 UTC · v1
theoryunusual

Abstract

Kadloor and Santhi (arXiv:1011.4098) modeled cascading failures in a large fully connected power grid by a coupled four-variable recursion for the minimum surviving load $a_n$, the mean failed load $μ_{n-1}$, the redistributed load $\mathcal{D}_n$, and the stagewise failure probability $p_n$. They noted that the recursion was not tractable and identified the critical disturbance $d_{\mathrm{critical}}$ by simulation. We show that the recursion telescopes exactly into a one-dimensional monotone map $a_{n+1} = g(a_n)$. This yields the threshold in closed form: $1 - a_0 = d_{\mathrm{critical}}\,(1 + \ln(1 + 1/d_{\mathrm{critical}}))$, or explicitly in terms of the lower branch $W_{-1}$ of the Lambert W function. We prove a sharp dichotomy. For $d_m \le d_{\mathrm{critical}}$ the cascade halts with limiting load $a_0 + d_{\mathrm{critical}}$ at criticality and surviving fraction $1/(1 + d_{\mathrm{critical}})$. For $d_m > d_{\mathrm{critical}}$ a complete outage occurs in finitely many steps.

Closest papers

Nearest neighbours by meaning across the whole index.

A Decoupled Approach for Modeling N-k Interdiction with Induced Failures in Electric Power Grids

eess.SY ·2026-10-13 ·Andrew Chio, Kaarthik Sundar, Russell Bent, Nalini Venkatasubramanian
benchmark similarity 0.54
Abstract

The electric power grid is a critical infrastructure system subject to different types of failures which can have devastating impacts on society. One framework to study the resilience of the grid is the N-k interdiction model, which introduces an attacker and defender model to identify grid vulnerabilities. However, traditional N-k interdiction models characterize the power grid with steady-state assumptions. One key aspect missing from this analysis is the behavior of the grid as it evolves from the pre-failure grid state and post-failure grid state. During such a transition period, automated protection systems, transient instabilities, and other phenomena can trigger cascading failures that can occur before grid operators can respond. To bridge this gap, this paper first introduces the generalized induced failure N-k (N-k.k') problem, where an initial set of k failures induces an additional set of k' failures. In this context, we propose a disjoint optimization approach that decouples the computation of cascading failures from the interdiction model. This system response model, furthermore, is treated as a black box module without compromising the underlying performance guarantees of the interdiction model. Extensive experiments on several benchmark power grid case studies showcase the efficacy and scalability of the approach.

0.22

Cascading Contingency Analysis of Modern Power Systems Using a Stochastic Hybrid Systems Framework

eess.SY eess.SP ·2026-11-10 ·Masoud H. Nazari, Hamid Varmazyari
published similarity 0.52
Abstract · This paper was accepted at the 2026 North American Power Symposium (NAPS)

This paper presents a cascading contingency analysis and risk assessment framework that incorporates probabilistic mode transitions motivated by stochastic hybrid system (SHS) concepts together with power-flow-based stress evaluation. A two-stage modeling approach is adopted in which sensitivity-based analysis is first used to identify candidate cascading transitions, followed by DC power flow re-evaluation to accurately capture post-contingency stress redistribution, islanding behavior, and load shedding. A probabilistic propagation model is constructed using mode-dependent transition probabilities derived from line loading conditions. A Cascading Risk Index (CRI) is introduced to quantify the expected load shedding accumulated over cascade progression. Case studies on the IEEE 39-bus system demonstrate that the proposed framework captures diverse cascading routes under multiple initiating outages and identifies critical propagation patterns that are not revealed by N-1/N-2 screening. The results highlight the importance of SHS modeling in assessing cascading risk and providing a scalable framework for resilience evaluation in modern power systems.

0.34

Minimum Bounding Sets for N-1-1 Branch Contingencies Under Thermal and Voltage Limits in Linear Network Models

eess.SY ·2026-10-08 ·Timothy N. Thacker
similarity 0.51
Abstract · 10 pages, 4 figures

N-1-1 contingency analysis studies the loss of one element followed by system adjustments and the loss of a second. The number of contingency pairs increases quadratically with the number of applicable elements, and traditional ranking-based screening methods cannot guarantee that omitted pairs are bounded. This paper determines the minimum bounding set of two-branch-outage pairs: the smallest set that can reproduce the worst value of every violated thermal and voltage limit of a linear network model. In the DC model, effects of an outage pair can be quantified by the extent of the coupling between the outages. The paper measures this by the cosine between the two outages in the network's cycle space, with a bound that splits into one term per outage and is within a near-ideal factor of $\sqrt{1+\varepsilon}$. This argument extends to every linear model in which an outage subtracts a positive semi-definite low-rank term from a symmetric positive definite matrix, with a tight bound and a collapse test. A model with voltage magnitudes is extracted by performing one Newton step on the energy function of the lossless network in rectangular coordinates. A best-first search built on these bounds reproduced brute force on public systems of up to 2{,}869 buses with 130 to 3{,}800 times fewer pair evaluations for flows and 170 to 23{,}700 times fewer for voltages. Gaps in translation to nonlinear models are explored on the IEEE 118-bus system.

0.26

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.48
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Counterfactual Action-Conditioned Graph Prediction for Cascading-Failure Mitigation in Power Systems

eess.SY ·2026-10-12 ·Fangxin Liu, Zhentao Tian
similarity 0.47
Abstract

Cascading failures develop through coupled power flow redistribution, protection actions, and topology changes, making remedial control dependent on how alternative interventions modify the subsequent trajectory. This paper develops an action-conditioned graph predictor (ACGP) for multi-step cascade prediction and closed-loop mitigation. A same-state counterfactual branching procedure replays identical post-contingency grid states under multiple legal actions while preserving the exogenous trajectory, providing direct supervision for action-dependent electrical states, line connectivity, automatic protection trips, and terminal risk. ACGP is embedded in a receding-horizon controller that evaluates five-step candidate futures, executes the selected intervention, and replans from the observed next state. The final dataset contains 2,860 counter factual roots and 22,880 action-conditioned branches. On the held-out test set, ACGP achieves a five-step line-loading MAE of 0.0369 and a redispatch pairwise ranking accuracy of 0.806; action ablations reduce the ranking accuracy to approximately chance level. In closed-loop Grid2Op experiments, terminal-failure and cascade rates decrease from 53.3% and 51.1% under do-nothing operation to 12.2% and 7.8%, respectively, close to the simulator-reference values of 11.1% and 6.7%. The results show that same-state counterfactual prediction can support effective action comparison and feedback-based cascading-failure mitigation.

0.22

Absence of critical scaling in the Schelling segregation model

cs.GT cond-mat.stat-mechcs.MA ·2026-08-17 ·Mouhssine Rifaki
theoryunusual similarity 0.47
Abstract · 24 pages, 16 figures, 6 appendices. Over 12,500 simulation runs on periodic grids up to L = 320; Chebyshev radii r_0 up to 6 (k = 168 neighb…

We find no evidence of critical scaling in the Schelling segregation model, in either the Moore neighborhood or its dense-spectrum extension to Chebyshev radii up to $r_0 = 6$ ($k = 168$ neighbors). On periodic grids up to $L = 320$ with 50 trials per point (> 12,500 runs), every finite-size scaling diagnostic in the Moore baseline fails: the per-$L$ $T_c$ does not drift, Var$(S) \sim L^{-2.02 \pm 0.09}$ matches trivial averaging, $γ/ν\approx 0$, and the scaling collapse never reaches a finite optimum. The 8-site Moore neighborhood restricts satisfaction to ratios $j/k$ with $k \leq 8$, giving $S(T)$ a staircase structure with 23 rational thresholds; discreteness alone does not forbid criticality (cf. the Ising model), but the scaling evidence rules it out empirically. A branching-ratio calculation predicts subcritical cascades of mean size $1/(1-R)$ and is validated by perturbation experiments to within 15%; the multiscalar dissimilarity length stays finite across the transition. The dense-spectrum extension strengthens the negative verdict: across $r_0 \in {3,4,5,6}$ on $L \in {40,80,160}$ the Binder cumulant has no $L$-curve crossing and the per-$L$ $T_c$ drift is monotonic and unsaturated; at $r_0 = 4$, extending to $L = 320$ gives $α= -2.70$, below the critical boundary $α= -2$, dissolving an apparent $α= +0.81$ signal visible only on $L \in {40,80}$. The mechanism is the absence of long-range correlation in equilibrium plus deterministic high-$k$ dynamics, not the staircase structure. With a Beta-distributed heterogeneous tolerance, the intolerant tail drives segregation even at moderate population-average tolerance. The staircase theorem and cascade mechanism together account for the Schelling transition without invoking critical phenomena.

0.31

When Gigawatts of Computational Load Disappear: Cycle-Space Certificates for Grid Synchronization and Transient Stability

eess.SY math.DSphysics.soc-ph ·2026-09-23 ·Michael Chertkov
similarity 0.47
Abstract · 13 pages, 2 figures

Rapid growth of data centers and artificial-intelligence services is producing computational loads at scales once associated mainly with largest power plants. Recent grid events show that a routine transmission disturbance can cause several gigawatts of data-center demand to disconnect or transfer to backup nearly at once. This article revisits the classical synchronization and transient-stability theory needed to reason about such events. We organize four lines of work---graph-based synchronization conditions, winding-number descriptions of nonlinear power flow, separable convex network optimization, and direct energy methods---into a single cycle-space certificate framework for the lossless fixed-voltage model. The static layer gives an exact strict-cohesion test within a prescribed winding cell and reveals the widely used Dörfler--Chertkov--Bullo test as a quadratic surrogate of the same convex problem. The dynamic layer converts the critical-energy calculation into a finite family of convex boundary problems. Standard MATPOWER benchmarks illustrate both what the stronger static test gains and where it gains nothing: the 118-bus case admits $16.2\%$ more loading than the sufficient screen, while the 39-bus case is bridge-limited and the thresholds coincide. A stylized $2.7$-GW 39-bus event further shows that transient margin can change by about a factor of two depending on where balancing power is supplied, even when every final balanced operating point remains statically feasible. The result is a tutorial synthesis and an extensible deterministic certificate for emerging gigawatt-scale computational-load contingencies.

0.53

Generalization Testing of Grid Foundation Models for Power Flow and Optimal Power Flow

eess.SY cs.LG ·2026-11-14 ·Ayushi Jolotia, Parikshit Pareek
similarity 0.46
Abstract

There is growing interest in foundation models (FMs) for power grids, particularly for power flow and optimal power flow. Their usefulness depends on generalization accuracy, which existing works test on their own benchmarks. We propose a three-axis framework to test their generalization limits: changed admittance matrices of training grids, load levels, and unseen grids. We test GENCO, LUMINA and GridSFM against the DC baseline, alongside their reported limitations, and discuss theoretical reasons for their failures. Experiments reveal that adding a line degrades all FMs more than removing one, and longer lines eventually make LUMINA and fine-tuned GENCO worse than DC. All three degrade beyond their training load range, where the loading-voltage curve steepens. On unseen grids, LUMINA degrades sharply even inside its training range, and GridSFM fails on the grid farthest from it. Thus, beyond training conditions, FMs behave more like meta-models requiring test-time fine-tuning data and compute.

0.23