CS Paper Radar

Can AI Design a Better nnU-Net? A Hypothesis-Driven Architecture Discovery Loop from Failures to Design Rules

Songtao Jiang, Yuan Wang, Fucheng Niu, Hualiang Wang, Jian Wu, Zuozhu Liu

cs.AI cs.LG ·submitted 2026-11-24 10:49 UTC · v1

Abstract

Neural architecture search and LLM-driven evolution often reduce evaluation to a scalar fitness score, discarding failures that could explain why designs succeed or fail. We present a hypothesis-driven architecture discovery loop in which LLM agents diagnose structured error patterns, formulate falsifiable hypotheses, test counterfactual controls under a frozen nnU-Net pipeline, and distill validated mechanisms into executable trigger-to-action rules. Across eight search waves, the loop identifies two principles for 3D medical image segmentation. First, reallocating computation from high-resolution decoders to the mid-encoder preserves thin-anatomy boundaries while reducing cost. Second, support-confined region contrast addresses errors between nested anatomical compartments, with anatomy-dependent triggers selecting when the rule applies. These principles produce LeanNeXt (0.78 MACs and 0.92 training-step time relative to nnU-Net; +1.63 Dice points on four-fold KiTS23 cross-validation) and trigger-routed LeanNeXt+. The latter improves all 15 evaluated CT/MRI settings over nnU-Net and exceeds the 3.3 larger ResEnc-M on 12 of 15 benchmarks at 0.30 its parameter count. Relative to random sampling, one-shot LLM generation, and score-selected agent search, the loop shows how failure analysis can yield reusable design rules across modalities.

Comment
15 Pages; 10 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Medical Image Segmentation Is Now Just Another Coding Task

cs.CV ·2026-11-23 ·Shuheng Cao, Ruiqi Chen, Qizhen Lan, Edward Wang, Xiyun Hu +4 more
similarity 0.70
Abstract

For decades, every new medical image segmentation task has needed an expert, a dedicated architecture, and a framework such as nnU-Net. This is no longer the case: medical image segmentation is now just another coding task. Given only a task description, labeled data, and a CPU (with no segmentation framework, no pretrained weights, and no human in the loop), four off-the-shelf coding agents built segmenters for 13 tasks across four imaging modalities within hours, an ability that has emerged rather than been built. On the nine 2D tasks, their best programs reach 99% of the Dice of a GPU-trained nnU-Net. Like any code, a segmenter improves by being revised and checked, so we ask how far the same agents can improve their own segmentations and what unlocks further gains. On unseen cases there is no reference, so the agents inspect renderings of their own predictions: this alone lifts the worst tenth of cases by 0.09 Dice and cuts boundary error (HD95) by almost a quarter. Far more is within reach. Told the true Dice of each attempt, the same agents improve in all 14 matched pairs, rescue 85% of failed masks instead of 30%, and surpass the GPU-trained nnU-Net on average, by producing better masks rather than by choosing among them. What unlocks these gains is a quality signal, which neither visual inspection, nor more rounds, nor a quality estimator trained by the agents themselves yet supplies: we call this the quality blind spot. The ability to build and to repair is already present; the next advance will come not from another segmentation model, but from reference-free quality estimation that coding agents can call.

0.17

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.67
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.14

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.67
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

VoxelSage: Tool-Augmented 3D CT Analysis and Simulator-Shielded Sequential Resection Planning for Liver Tumors

cs.CV eess.IV ·2026-09-29 ·Binghong Qian, Xuanhe Liu, Yifan Xing, Wenjie Deng, Jian Wu +1 more
code/data similarity 0.66
Abstract · 21 pages, 10 figures. Technical report. Code at https://github.com/ZJUMAI/VoxelSage

Preoperative liver-tumor assessment requires segmentation, physical-space measurement, visual evidence, and resection planning from the same three-dimensional CT volume. Existing tools often handle these steps separately, while language models cannot reliably compute physical measurements from CT. To provide an integrated workflow, we present VoxelSage, a multi-modal system for two- and three-dimensional visualization, liver-tumor analysis, and preoperative resection planning. Its dual-port architecture separates language-model orchestration from image computation: Port A interprets requests and selects skills, while Port B applies them to CT volumes and segmentation masks and returns structured results. Keeping physical measurements in Port B prevents the LLM from computing them directly and reduces the risk of fabricated numerical results. Eight built-in skills support quantitative analysis, visual evidence generation, three-dimensional reconstruction, segmentation refinement, and sequential resection planning; user-defined skills can extend these functions. For sequence planning, a behavior-cloned neural ranker orders candidate resection targets, while a simulator-based shield checks them against predefined constraints. Across 256 unseen simulator scenes, this approach reduced mean simulated time from 34.274 to 33.388 min (0.886 min, 2.59%) and mean simulated blood loss from 300.847 to 183.852 mL (116.995 mL, 38.89%) relative to a deterministic baseline. These results demonstrate system integration and simulator-level performance, not clinical efficacy or safety. The public implementation is available at https://github.com/ZJUMAI/VoxelSage.

0.29

Can Coding Agents Build Robust Baselines? A Skill-Based Approach for Automating the Medical Imaging Model-Development Pipeline

cs.CV ·2026-08-24 ·Eugenia Moris, José Ignacio Orlando
publishedbenchmark similarity 0.66
Abstract · MICCAI 2026 Workshop AgenticMed

Developing competitive deep learning baselines for medical imaging remains a highly iterative process requiring literature review, implementation, experimentation, and expert refinement. Existing automation approaches typically optimize isolated components, such as architecture search or hyperparameter tuning, rather than the complete baseline development process. We present an agentic AI Scientist workflow that combines literature-guided reasoning, automated code generation, and hypothesis-driven experimentation to generate competitive baseline models for medical imaging challenges. The framework is evaluated on four public benchmarks spanning segmentation, classification, and detection. Across all tasks, the Experimentation Pipeline consistently improves validation performance, achieving competitive leaderboard results, including 6th place on both PUMA tracks (15 teams) and 31st place on MILK10k (125 teams). On MIDOG25, the resulting model also demonstrates strong domain generalization across scanners, tumor types, and species. Using the same workflow across all challenges without task-specific redesign, we demonstrate that skill-based, literature-guided agentic workflows can substantially reduce the engineering effort required to develop competitive medical imaging baselines.

0.26

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.66
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Active-DiNTS: Active Differentiable Network Topology Search

cs.CV cs.AIcs.LGcs.NE ·2026-10-03 ·Gean Trindade Pereira, Thierry Urruty, Muriel Visani, André C. P. L. F. de Carvalho
benchmark similarity 0.66
Abstract · 19 pages, 7 figures, 3 tables. Extends material from the first author's PhD thesis (University of Sao Paulo / La Rochelle Universite, 2024)

Neural Architecture Search (NAS) has proved to be a strong alternative to manual network design, but applying it to 3D medical image segmentation is limited by two well-known costs, large annotation budgets and multi-GPU clusters. Thus, this paper introduces Active-DiNTS (Active Differentiable Network Topology Search), an approach that embeds pool-based Active Learning (AL) into a bi-level differentiable topology search to perform architecture discovery and label curation jointly. At each query round, unlabeled MRI volumes are ranked by one of three uncertainty signals (Entropy, Variance, or Standard Deviation), and only the top-ranked volumes are sent to an oracle for annotation. The new labels feed two interlocked stages. Network weights are updated in an outer loop, while the macro/micro topology of a U-Net-style backbone is refined in an inner loop. Three AL regimes (weights-only, topology-only, joint) expose the speed-accuracy trade-off. Evaluations on the Medical Segmentation Decathlon (MSD) Task01 BrainTumour benchmark showed that Active-DiNTS surpasses DiNTS, C2FNAS, and nnU-Net in Dice, with gains of about 10 percentage points on Edema and 5 points on Non-Enhancing core, on a single GPU and using a fraction of the labeled volumes. The discovered architectures are denser and more FLOP-heavy than prior baselines, but remain competitive in trainable parameters and peak memory; the fastest search variant finishes in under 0.25 GPU-days, over 27x faster than the eight-GPU DiNTS search. Together, these results indicate that pairing differentiable NAS with active data acquisition is a practical recipe for accurate 3D segmentation under realistic constraints.

0.25

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.66
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.36