CS Paper Radar

Label leakage through file headers: geometry and batch confounds in public mammography datasets, and a pre-training acceptance gate

Achraf Toufah, Rana Saad, Moulay Youssef El Hafidi

cs.CV cs.LGeess.IV ·submitted 2026-11-24 16:25 UTC · v1

Abstract

A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance. We applied pre-training controls that see only image geometry, global texture, a sub-collection identifier or one covariate to six public mammography datasets, against a stop threshold of AUC 0.60. In KAU-BCMD, geometry alone predicted the BI-RADS class at AUC 1.0000 in a local copy and at a mean of 0.979 in a public Kaggle archive; after resizing, texture alone gave 0.847. In CMMD, the sub-collection prefix predicted malignancy at 0.7753; the restricted sub-collection passed geometry (0.5000) and texture (0.5810) but failed an identifier-order control added post hoc (test AUC 0.9926). CBIS-DDSM exceeded the stop on geometry (pooled mean 0.654 over 20 splits), a verdict statistic chosen post hoc; its official mass and calcification splits did not. M-SYNTH, INbreast and a partial VinDr-Mammo copy passed the few controls run. We release the code and derived tables. There is no quantum component in the inference path.

Comment
27 pages, 2 figures, 9 tables. Under review at DMLR. Code and derived tables: https://doi.org/10.5281/zenodo.24372683

Closest papers

Nearest neighbours by meaning across the whole index.

Leakage-Free Is Not Confounder-Free: What a Patient-Level Split Cannot Certify About a Medical Imaging Benchmark

cs.CV ·2026-11-20 ·Ignazio Gallo, Mattia Gatti, Leonardo Sgroi, Darwin Castillo, Yuliana Jiménez-Gaona +1 more
benchmarkcode/data similarity 0.63
Abstract · 28 pages, 6 figures, 18 tables. Code, configurations and aggregate results: https://github.com/ignaziogallo/breast_thermography_reliable_ai.…

Patient-level splitting is the standard safeguard against subject leakage in medical imaging evaluation, but it cannot remove a confounder that every fold inherits: an acquisition variable aligned with the diagnosis across the whole cohort. We present a five-question audit of a candidate confounder: how well it predicts the diagnosis, whether it can be decoded from the images, whether diagnostic scores depend on it, whether the image adds predictive value beyond it and how much discrimination survives once it is controlled. We apply it to DMR-IR, the public dataset on which most machine-learning results in breast thermography rest. On 236 patients under a strict patient-disjoint protocol, the acquisition date alone predicts malignancy at AUROC 0.980, above every imaging arm we evaluated (best 0.949), because benign and malignant patients were recruited in different years. The acquisition year is decodable from the pixels among patients who share a diagnosis, largely through a global thermal offset outside the breast, yet only one arm, the one pooling every frame of a visit, demonstrably carries it into its diagnostic score. No arm improves on the date on paired folds, and once the date is controlled, discrimination either collapses or survives only on comparisons the benchmark cannot attribute. The dataset contains only eight cross-label same-date pairs, from ten patients, which limits reliable evaluation within recorded acquisition-date groups. A second, independently acquired cohort, whose dominant channel is patient age, reproduces every finding except legibility, from a confounder that is clinically legitimate. Mitigation may suppress such a confounder, but without cross-label acquisition support no evaluation on the benchmark can certify that what remains is pathology.

0.34

MammoSeek: A Mammography Agent with selective zooming for grounded reports

cs.CV ·2026-11-04 ·Haoyan Ding, Qian Wang, Lixia Wang, Debiao Li
similarity 0.60
Abstract · 5 pages, 2 figures

Radiologists read a screening mammogram by first forming a global impression of the four views and then selectively magnifying suspicious regions before assigning a BI-RADS assessment. MLLMs, in contrast, see the whole image at a fixed, reduced resolution, which makes sub-millimeter calcifications invisible, and they perform close to chance on mammography. Therefore, we present MammoSeek, a mammography agent that reproduces this reading process. After forming an impression of each breast, the agent performs selective zooming: it decides by itself which detector candidates deserve a closer look and inspects only those on full-resolution views. Guided by a BI-RADS assessment skill, it then assigns a category and generates a localized, lexicon-structured report for each breast; its assessment is combined with image-model scores in a decision layer to decide recall. On an internal (EMBED) and an external (VinDr-Mammo) dataset, \ours reaches exam-level AUCs of 0.824 and 0.818, far above other MLLMs, mammography agent and CNN classifiers. Selective zooming also outperforms both no zooming and forced zooming in localization, structured-report F1 and recall decisions at low cost.

0.26

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

cs.CV cs.AI ·2026-09-30 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.59
Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

0.43

Less Annotation, More Interpretation: Prior-Guided Concept Bottleneck Models for Interpretable Cancer Imaging Diagnosis

cs.CV ·2026-08-13 ·Baoqiang Ma, Kenneth Gilhuijs
published similarity 0.57
Abstract · Accepted at the iMIMIC Workshop at MICCAI 2026

Concept bottleneck models (CBMs) can improve the transparency of cancer image diagnostic prediction by expressing predictions through radiological concepts. However, their dependence on instance-level concept annotations limits practical applicability. We propose a prior-guided hybrid CBM that integrates limited concept annotations, class-conditional concept distribution matching on unannotated patients, and prior initialization of the concept-to-diagnosis head. We evaluate the method on CBIS-DDSM mammographic masses and calcifications and LIDC-IDRI pulmonary nodules across 0-100% concept annotation. In the clinically relevant 0-20% annotation regime, the hybrid CBM consistently improves mean concept AUC over a matched standard CBM, while maintaining diagnostic performance close to black-box models. At 10% annotation specifically, concept AUC increases from 0.619 to 0.741 for masses, from 0.650 to 0.787 for calcifications, and from 0.597 to 0.642 for pulmonary nodules. Ablation experiments identify prior initialization as the main component contributing to improved concept detection, likely by stabilizing the concept-to-diagnosis head. Zero-shot VLMs remain insufficient for reliable fine-grained tumor-level concept prediction. These findings suggest that structured priors can substantially reduce the annotation burden of interpretable cancer imaging models.

0.18

Label-Space Mismatch Distorts Cross-Cohort Evaluation in Breast Cancer Molecular Subtyping

cs.LG cs.AIq-bio.QM ·2026-10-18 ·Suxing Liu, Byungwon Min, Zhijian Zheng, Jiahao Wang
similarity 0.57
Abstract

Cross-cohort evaluation of breast cancer subtype classifiers is unreliable when source and target cohorts use different annotation standards: METABRIC labels six classes, PAM50 defines five, and a claudin-low prediction cannot be correct under a five-class standard. A classifier transferred from 1,369 METABRIC patients (train n=958) to TCGA-BRCA (n=987) and GSE21653 (n=266) separates three evaluation operations routinely conflated in cross-site comparisons. (1) Label-space restriction - an evaluation-rule change, not a retraining gain - is the dominant correction (73.76%->79.74% on TCGA-BRCA; 63.16%->68.42% on GSE21653); (2) EM prior correction on the reconciled space is an optional calibration step (Brier fidelity up, macro F1 down; to 80.65% and 74.06%); and (3) the target label space is not recoverable from unlabelled predictions (EM retains prior 0.0751 on the absent class; calibrated detectors fail), so compliance must come from cohort documentation. The protocol exposes why internal validation overstates cross-cohort value: multimodal fusion gains do not transfer (no configuration beats mRNA alone, n=694; McNemar p=0.13-1.00), and the genomic panel adds nothing to pathological complete response prediction over clinical variables (DeltaAUC = +0.0045). Clinically, without label-space compliance, cross-site accuracy comparisons misattribute annotation-standard differences to model skill; Luminal A/B and claudin-low boundary errors map to distinct treatment decisions; and subtype accuracy is a weaker portable endpoint than survival discrimination (external C-index 0.577-0.584). Reporting the cohort's allowed label set and applying label-space compliance are therefore prerequisites before any cross-cohort performance claim.

0.26

Evaluation Choices Shape Biomedical ML Claims: A Pediatric Pneumonia Benchmark Case Study

cs.CV cs.LG ·2026-09-29 ·Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala
benchmark similarity 0.57
Abstract

Biomedical machine learning papers often compress model performance into one headline number. That number can look like a property of the model even when it depends strongly on how the benchmark was evaluated. We study this problem on the widely used Kermany pediatric chest radiograph dataset using nine image classifiers and a controlled evaluation protocol. Under the same protocol, the eight pretrained backbones differ by only 0.026 AUROC. In contrast, changing whether the backbone is frozen or fine-tuned changes AUROC by 0.044 on average, and changing the decision threshold changes balanced accuracy by 0.090 on average. The official test split is also measurably different from the training pool: a partition classifier distinguishes them at AUC 0.697, rising to 0.898 for normal radiographs. Most strikingly, a classifier using only file properties, with no image anatomy, reaches 0.992 balanced accuracy within the training pool but falls to 0.496 on the official test split. Validation-fitted thresholds and calibration also transfer imperfectly. These results show that a high benchmark score can support different conclusions when the split, training policy, threshold, metric, calibration, and uncertainty are not communicated with it. We end with a seven-item reporting recommendation in which each item is tied to an effect measured in the study

0.11

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.55
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.55
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28