CS Paper Radar

A Robust Optimization Framework for Energy System Capacity Expansion under Line Outage Uncertainty

Kamran Forghani, Lina Reichenberg, Fredrik Hedenus, Iegor Riepin

eess.SY math.OC ·submitted 2026-11-25 10:15 UTC · v1
theory

Abstract

Capacity expansion models are widely used in climate and energy policy analysis to find optimal investments in generation, storage, and transmission. As the share of renewable generation grows, these models rely more on transmission lines to balance supply and demand across regions. Transmission lines, however, can fail due to aging, extreme weather, or accidents. Models that represent outages as time-dependent events come mainly from electrical engineering and are applied to small-scale systems, as they quickly become computationally intractable for inter-regional capacity expansion. We develop a capacity expansion model in which the risk of line failures shapes the investments in all parts of the system. We formulate it as a two-stage, scenario-based robust optimization problem that samples time-varying outage scenarios from a Markov model and hedges the investments against the most severe ones. To solve the model, we propose a memory-augmented Benders decomposition algorithm combined with Monte Carlo simulation that can handle thousands of scenarios. The selected plan is then evaluated with an out-of-sample simulation to bound the Value-at-Risk (VaR) of its system cost. In a 25-node case study of Germany and its neighboring countries, the gap between the lower bound and the simulated VaR bound is below 1%. We compare the robust plans with a deterministic plan, which assumes all lines are always available, and with a reserve-margin heuristic, which requires local firm capacity to be above peak demand. Like the heuristic, the robust plans nearly eliminate loss of load in 1000 simulated outage scenarios. Their mean system cost is within 0.2% of the deterministic plan and about 4.5% below the heuristic. Instead of adding more generation capacity, the robust approach mainly changes the type and location of capacity, for example, by spreading storage across the network.

Comment
27 pages, 8 figures, 10 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Recovering Plausible Transmission Outage Scenarios

eess.SY math.OC ·2026-10-21 ·Karen Ji, Cameron Khanpour, Samuel Talkington, J. Kyle Skolfield, Daniel K. Molzahn
similarity 0.64
Abstract

Expansion planning for extreme weather needs outage scenarios that specify which transmission branches fail. However, public outage records often only report customers without power by county, making it unclear how to exploit this information to create outage scenarios. We propose a method to recover sets of outaged branches that most closely match regional load shed data. This gives us sets of plausible outages for a given hazard event. We formulate a bilevel problem with a load shedding DC optimal power flow in the lower level. We relax the binary branch states to differentiate the lower level problem, replace it with its sensitivity matrix, and use gradient descent to update the upper level. We treat the relaxed branch states as probabilities and perform randomized rounding to restore integrality. On three test systems with synthetic outages, the recovered sets reduce the load shed error to $0.02-4.5\%$. On the California Test System with storm data from December 2025, the error falls to $23\%$. These scenarios give expansion planning a reliable source of outage data tied to observed hazards.

0.17

Online Learning-Based Adaptive Hybrid Benders Decomposition for Risk-Averse Optimal Sizing

eess.SY ·2026-09-22 ·Saif Ahmad, Seifeddine Benelghali, Hafiz Ahmed
similarity 0.63
Abstract

Optimal sizing problem (OSP) for battery energy storage system (BESS) under uncertain inputs is often formulated as a two-stage stochastic program (2SP), which typically introduces computational and RAM (memory) bottlenecks for large scenario sets. Benders Decomposition (BD) is a popular approach for tackling this problem, but it suffers from slow convergence to the exact solution. To address this problem, we propose an accelerated online learning-based adaptive hybrid BD algorithm for a risk-averse 2SP formulation. The proposed method avoids getting stuck in the infeasible region during early iterations by explicitly embedding a carefully selected scenario in the master problem, while a tail-relevant scenario selector based on online learning helps to avoid solving the entire scenario set at every iteration. The OSP is formulated to select a behind-the-meter BESS in a multi-site energy community with existing renewables. The use case explores an interesting middle-ground between deterministic acceleration methods and training-heavy ML models, showcasing the potential of ML-assisted decision-making. Compared with vanilla BD, OLAH-BD reduces subproblem evaluations and total wall time by up to 80\% under the same tolerance settings.

0.19

Compound Climate Risk-Aware Electricity Dispatch: Trajectory-Based Modeling for Power System Resilience

eess.SY ·2026-10-29 ·Feiyu Cai, Jing Qiu, Chenxi Zhang, Yi Yang, Yuechuan Tao +1 more
similarity 0.63
Abstract · 10 pages, 8 figures

In recent decades, emerging compound hazards in a changing climate have increasingly threatened power system resilience and posed new challenges to electricity dispatch. Conventional Value-at-Risk (VaR)-based risk-aware dispatch provides a tractable means of managing stochastic net demand deviations caused by distribution feeder outages. However, when applied to temporally compounding events such as tropical cyclone (TC)--blackout--heatwave, conventional net demand risk formulations may assign similar risk levels to a brief outage and an outage with the same instantaneous net demand impact that persists into a subsequent hazard, despite their different requirements for sustained operational flexibility. Moreover, directly incorporating compound risk into electricity dispatch models faces a structural mismatch: the risk is defined by the joint distribution of feeder restoration and subsequent hazards over exponentially many joint states, whereas dispatch models require risk formulations that are tractable in the scheduling decisions. To address these issues, this paper proposes a compound climate risk-aware dispatch framework with a trajectory-based compound risk model, which defines the loss on operating deviations determined by entire feeder connection trajectories, parameterized by uncertain restoration times and coupled with subsequent hazards. Analytical moment-generating functions and equivalent exponential-cone reformulations provide a compact representation of the resulting risk constraints, preserving the relevant dependencies without explicit joint-state enumeration. By leveraging a physics-based spatiotemporal TC--blackout--heatwave hazard model, case studies demonstrate the effectiveness of the proposed method with real-world time-series power outage data from Puerto Rico, including data collected during Hurricane Fiona in 2022.

0.34

A multi-stage probabilistic framework to estimate gas-fired generator performance during extreme winter weather

cs.LG stat.ML ·2026-10-03 ·Sajjad Uddin Mahmud, Anamika Dubey
similarity 0.62
Abstract

Extreme winter weather has repeatedly disrupted gas-fired power generation in the United States, yet the plant-level data needed to systematically quantify outage risk remain proprietary. Using publicly available weather and electricity demand data together with anonymized generator contingency records from the North American Electric Reliability Corporation (NERC), we develop a three-stage Bayesian probabilistic framework for estimating winter-driven generator performance. Applied to New York State (2013--2022), the framework sequentially estimates: the hourly probability of a generator contingency event, the expected net available capacity conditioned on an event occurring, and the event duration. Colder conditions and higher electricity demand are associated with higher failure probability, lower retained capacity, and longer event duration. Under the most severe observed stress conditions, estimated mean hourly event probability reaches 24\% , while expected mean net available capacity falls to 13\% of nameplate rating. Full outage events have a median duration of 12.7 hours, while partial derating event duration increases from 2.4 to 7.1 hours with capacity loss severity. The proposed framework establishes a transferable baseline that utilities with access to plant-level records can directly extend to obtain more precise reliability estimates for operational planning and resource adequacy assessment.

0.24

Reliability-based Sizing of Energy Storage for Large Load Integration

eess.SY ·2026-11-18 ·Atri Bera, Chandan Chaudhary, Dilip Pandit, Cody J. Newlun, Tu A. Nguyen +2 more
published similarity 0.62
Abstract · 12 pages, 1 figure, published as part of the proceedings of the 2026 Grid of the Future Symposium organized by the CIGRE US National Committ…

The number of large loads connected to the bulk power system has been increasing rapidly worldwide. Emerging high-demand facilities, particularly AI data centers, are introducing new challenges for power system planners. In absence of appropriate planning mechanisms, the addition of high volumes of data center loads will lead to an increase in outages, thus degrading reliability of the system. Energy storage systems (ESS) offer a promising solution to mitigate the reliability impacts of these large loads, due to their flexibility and fast-ramping characteristics. However, ESS should be judiciously sized and sited to maximize the reliability benefits to the grid. This paper presents a framework for the optimal sizing and siting of ESS to minimize the adverse reliability impacts of large load additions. First, a stochastic semi-Markov model is developed to model the load of AI data centers and generate profiles for several such facilities. These profiles are then incorporated into a Markov-chain Monte Carlo simulation-based composite system reliability assessment framework. A detailed nodal network model is used to quantify the reliability impacts of adding data centers and to identify buses most affected by large loads. Resource adequacy metrics are used to evaluate the overall system reliability impacts. ESS are then strategically sized and sited based on this analysis to mitigate the negative impacts of large loads on overall system reliability. The proposed framework is demonstrated using the RTS-GMLC 72-bus test system. The results show how ESS can effectively enhance system reliability in the presence of rapidly growing large-load demand. This framework provides system planners, utilities, and regulators with a practical tool for maintaining reliable power system operation using energy storage as more large loads are integrated into the grid.

0.34

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.62
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

On the Concept of an Optimal Portfolio of Uncertain Flexible Loads

eess.SY ·2026-09-04 ·Julie Rousseau, Philipp Heer, Kristina Orehounig, Gabriela Hug
published similarity 0.61
Abstract · Accepted to the 2026 PowerUp conference

Flexible loads can enhance power system stability by providing reserves, but their limited energy capacity and uncertain availability distinguish them from conventional generators. To accommodate these characteristics, the Danish Transmission System Operator (TSO) recently introduced new reserve market rules that incorporate energy constraints and relax reliability requirements. In this context, the optimal reserve quantification becomes a joint chance-constrained reserve quantification problem, which is difficult to solve. In this paper, we derive two analytical reformulations of this problem: an exact one when a reserve direction dominates and an approximate one, otherwise. Furthermore, when flexible loads must collectively satisfy a reliability requirement, we introduce the concept of an optimal portfolio of flexible loads: adding loads with similar expected values but different stochastic behaviors to an existing portfolio may change the total portfolio's reserves. To support this idea, we theoretically study the marginal increase in reserves resulting from adding a load. Numerical results show that our analytical reformulations closely match the exact formulation, with a mean absolute error of 2.5%. Case studies further demonstrate the existence of optimal load groupings and our ability to predict the portfolio in which a load's marginal value is highest, leveraging our theoretical analysis.

0.43

Modeling of Network Constraints in Large-scale Capacity Expansion Optimization of Power Grids

eess.SY math.OC ·2026-08-28 ·Yu Weng, Lara Booth, Priya L. Donti, Ruaridh Macdonald
publishedtheoryhot direction similarity 0.60
Abstract

Capacity expansion modeling plays a critical role in optimizing the deployment of new generation, storage, and transmission, typically at national and regional levels. To support long-term planning, these models consider a large set of energy technologies and policies, along with decades of weather and demand data. Realistic capacity expansion models thus become high-dimensional optimization problems, with hundreds of millions of variables and constraints, which are challenging to solve. A common strategy to address this complexity is to omit non-linear, non-convex AC optimal power flow (ACOPF) constraints and instead use linearized power balance equations or transport formulations. While these simplifications improve tractability, they limit our understanding of how power flow and the physical properties of power networks impact investment decisions across generation, storage, and transmission infrastructure. This paper addresses this gap by extending the GenX capacity expansion model to incorporate fixed point theorem-based network constraints. These embed ACOPF-based considerations while maintaining the tractability of the planning model, nearly preserving the dimensionality of the transport formulation and incurring only modest runtime increases. This approach is much cheaper than embedding ACOPF directly, making it appropriate for large-scale capacity planning problems. We compare our approach to the original transport-based GenX model as well as a non-linear, non-convex version that incorporates the full ACOPF constraints, for a case study of the ISO New England grid.

0.47