CS Paper Radar

Weekly top 10 · eess.IV

2026-W33 Aug 10 – Aug 16, 2026

Ranked from 3,675 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Hybrid-LUT: Channel-Aware Hybrid Lookup Table and Filtering for Efficient Image Denoising

cs.CV eess.IV ·2026-08-12 ·Zhilin Ai, Boyu Li, Sidi Yang, Wenqing Shi, Wenyong Zhou +3 more
top venuecode/data
Abstract · Accepted by ECCV2026

Lookup table (LUT)-based image denoising methods have attracted increasing attention due to their high efficiency and hardware-friendly properties. However, existing RGB-LUT approaches require three identical LUTs to process RGB channels in parallel, resulting in large on-chip SRAM consumption. A simple alternative is to apply LUT processing only to the luminance (Y) channel in the YUV color space to reduce memory usage. However, this naive strategy leads to degraded restoration quality, since ignoring the chrominance (UV) channels introduces color distortion and residual artifacts. In this work, we propose Hybrid-LUT, a YUV-based asymmetric channel-processing framework that combines LUT and filtering in a unified design. Specifically, a multi-band LUT branch with pixel-level weight fusion is applied to the Y channel to recover fine textures, while lightweight filtering is used for the UV channels to maintain color consistency. This design reduces LUT storage by two-thirds compared with RGB-LUT methods while maintaining the same runtime throughput. Extensive experiments show that Hybrid-LUT achieves state-of-the-art (SOTA) performance across multiple benchmarks with only 421 KB of storage. In particular, our method surpasses existing LUT-based denoising approaches by at least 0.63 dB CPSNR on real-world datasets, demonstrating its effectiveness for image denoising on resource-constrained edge devices. The project is available at https://github.com/Ai-ZL/Hybrid-LUT .

0.84
2

Dual-Domain Cross-Modal Decoding for Clinical Text-Guided Medical Image Segmentation

cs.CV cs.AIeess.IV ·2026-08-11 ·Md Maklachur Rahman, Tracy Hammond
top venuecode/data
Abstract · Accepted at MICCAI 2026 (Main). Final version to appear in the MICCAI 2026 proceedings

Clinical text can narrow down what to segment, but recent text-guided designs emphasize spatial alignment while overlooking frequency content that governs texture and boundaries. We propose Dual-Domain Cross-Modal Decoding (DD-CMD) for clinical text-guided pulmonary infection segmentation, integrating two complementary forms of language guidance during decoding. In the spatial domain, Text-Guided Spatial Cross-Attention (TGSA) aligns multi-scale visual tokens with text semantics and updates features through gated residual fusion. In the frequency domain, Spectral-Text Adaptive Modulation (STAM) applies a 2D DCT to compute learnable band-energy statistics and predicts text-conditioned FiLM parameters to recalibrate decoder channels for frequency-aware decoding. DD-CMD embeds TGSA and STAM into a coarse-to-fine decoder (7x7 to 56x56) and restores full-resolution masks using a lightweight two-stage refinement module. Experiments on QaTa-COV19 and MosMedData+ show that DD-CMD achieves 91.46% Dice / 84.26% mIoU and 81.95% Dice / 69.42% mIoU, respectively, with average gains of +1.96 Dice and +2.67 mIoU over the strongest prior baselines. Code: https://github.com/maklachur/DD-CMD.

0.84
3

From crown candidates to neighborhood screening: integrating optical GeoAI and spatial modeling for urban-canopy assessment in Davis, California

eess.IV cs.CVstat.AP ·2026-08-14 ·Mohammadreza Narimani, Shreyan Mitra, Parastoo Farajpoor
code/datahighly cited
Abstract · 17 pages, 10 figures + 5 supplementary figures, 7 tables. Revised preprint (expanded canopy infill; IoU 0.719). Preprint submitted to Taylor…

Timely urban-canopy information is essential for linking remote sensing with heat, mobility, and neighborhood planning. We developed an optical GeoAI workflow for Davis, California, using 2022 National Agriculture Imagery Program imagery (0.6 m RGB+NIR). DeepForest generated crown candidates; an NDVI threshold, non-maximum suppression, and box-prompted Segment Anything Model (ViT-B) produced a crown-anchored canopy surface. Analyses used the 25.92 km2 Census TIGER municipal boundary and a 100 m grid. The workflow retained 11,741 candidate crowns and mapped 7.71 km2 of canopy (29.8% of the city). On the identical extent, pixel precision was 0.804, pixel recall was 0.873, and 97.4% of candidate centers agreed with the 2022 USDA/CAL FIRE LiDAR-assisted canopy product (IoU 0.719; Dice 0.837; area recovery 108.5%). Approximately 49% of candidates occurred within 15 m of a road. Canopy was inversely associated with Landsat land-surface temperature (Spearman rho = -0.477; partial rho = -0.551 controlling for built probability), and spatial-lag modeling confirmed clear neighborhood structure. Two transparent attention surfaces combined canopy need with thermal and contextual indicators. The framework provides a reproducible, updateable screening layer that complements structural canopy products and municipal inventories while retaining assumptions, data provenance, and spatial diagnostics for planning interpretation.

0.70
4

Automatic Field-of-View Adjustment for a View-Expansive Microscope via LSTM-Based Gaze and Pipette Motion Interpretation

cs.HC cs.LGcs.ROeess.IV ·2026-08-11 ·Kenta Yokoe, Takuya Hara, Tadayoshi Aoyama
published
Abstract · This is the accepted version of an article published in IEEE Access 13, 182915-182923 (2025). DOI: 10.1109/ACCESS.2025.3624246. Open Access …

Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.

0.62
5

Practical Lossless Volumetric Medical Image Compression via Tri-plane Context Tree Learning

eess.IV cs.CV ·2026-08-14 ·Yuanchao Bai, Yifan Zhao, Kai Wang, Yuanbo Du, Jie Cheng +3 more
published
Abstract

Lossless compression of volumetric medical images is of paramount importance for clinical and research applications where data fidelity is essential. Traditional compression methods are often limited in efficiency due to rigid, handcrafted models. Conversely, deep neural network (DNN)-based compression methods, while effective, demand substantial computational resources, hindering deployment in resource-constrained settings. To address these challenges, we propose a novel tri-plane context tree (TCT)-based method for lossless volumetric medical image compression that delivers high performance without relying on DNNs or external training data. To exploit intra-slice and inter-slice redundancies, we introduce a compact tri-plane context representation that decomposes complex 3D context modeling into efficient 2D modeling on three orthogonal planes. By integrating this representation with a context tree framework, we develop an input-specific TCT model employing an adaptive binary tree structure. At each tree node, the model dynamically selects from a suite of tri-plane based predictors and contextual feature extractors, enabling data-adaptive context modeling tailored to local structural characteristics. Instead of offline training, we sample a subset of the input volume to learn the TCT model by optimizing the minimum description length (MDL) through iterative construction and pruning. With the learned TCT model, each pixel retrieves its corresponding context, computes the prediction residual using the predictor dictated by the context, and performs entropy encoding based on the associated histograms. Experimental results demonstrate that the proposed method achieves compression performance on par with recent DNN-based methods on multiple datasets, while maintaining low computational cost and fast coding speeds, making it highly applicable in practice.

0.60
6

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59
7

ResPCC: A Loss-Resilient Neural Point Cloud Codec over Lossy Networks

eess.IV cs.MM ·2026-08-12 ·Xueqin Niu, Mufan Liu, Yifan Wang, Le Yang, Jun Sun +1 more
top venuecode/data
Abstract

Point cloud compression (PCC) is critical for efficient storage and transmission of 3D data. While recent learning-based PCC methods achieve good rate-distortion (R-D) performance, they generally rely on ideal transmission conditions. In practice, packet loss is a common issue and can severely distort latent features, causing coordinate drift and geometric degradation. To address this challenge, we present ResPCC, the first end-to-end neural point cloud codec designed to offer intrinsic resilience against data loss. Our framework is loss-rate-aware and adapts to diverse packet loss conditions. At the encoder, we introduce a Condition-Adaptive Latent Modulation (CALM) module to adjust latent feature distributions according to the perceived loss rate, as well as a Spatial-Channel Interleaving (SCI) mechanism that transforms channel-wise data extinction into spatially scattered element-wise missing patterns. At the decoder, we develop a Mask-Aware Graph-based Latent Restoration (MGLR) module, followed by a Dictionary-based Refinement (DBR) stage to recover corrupted features and align them with canonical priors. Evaluations on ShapeNet and SemanticKITTI under 5\% to 30\% packet loss rates show that ResPCC consistently delivers superior stability and R-D performance over baselines. Our framework maintains high reconstruction fidelity under lossy conditions, providing a reliable solution for 3D data transmission over practical networks. Code is available at https://github.com/starrynight314/ResPCC.

0.54
8

Geometry-Based Compression of Plenoptic Point Clouds

eess.IV cs.CVcs.MM ·2026-08-11 ·Davi R. Freitas, Gustavo L. Sandri, Ricardo L. de Queiroz
Abstract

Plenoptic point clouds (PPC) are novel data structures that represent the light from different viewing directions in order to provide a higher degree of realism to regular point clouds. This is achieved by associating each point to multiple colors instead of a single one. Here, we present a method to efficiently compress the attributes of a PPC, consisting of a Karhunen-Loève transform over the color attributes followed by multiple attribute coders with intra prediction capability. This compression scheme can be incorporated within the MPEG's geometry-based PCC (G-PCC) standard, using any of G-PCC's existing solutions for attribute coding. Compression performance assessment using PPCs of different spatial resolutions reveals competitive results in comparison to existing methods, such as RAHT-based or video-based PCC solutions. We believe our coder to be the new state of the art.

0.50
9

Lost in k-Space: An Open-Source MR-Physics Escape Room

eess.IV physics.med-ph ·2026-08-10 ·Sabine Melanie Räuber, Marta Brigid Maggioni, Francesco Santini
publishedcode/data
Abstract · 15 pages, 3 figures

Introduction. Operating an MR scanner for technical and clinical research requires multidisciplinary competencies beyond MR physics, including safety management and teamwork. Gamification, particularly educational escape rooms, have been associated with improved motivation, engagement and knowledge retention in health professional education. Materials and Methods. We developed an MR-physics-themed educational escape room for the 41st Annual Meeting of the ESMRMB. Designed for teams of four with a time limit of 25 minutes, the room reproduced the atmosphere of an MR control room. The five puzzles covered the Larmor equation, sequence composition, MR safety and acoustical identification of MR sequences. Custom ESP32 electronics allowed the puzzles to communicate in real time with each other and with the game master Results. The room ran without technical interruptions and was played by 39 teams (approximately 160 participants); 12 solved it (escape rate 31%), with a median solution time of 21 minutes and 53 seconds. Early-career researchers acted as game masters. Discussion. The escape rate aligns with comparable activities targeting scientific audiences. Difficulty can be tuned by adjusting puzzle obscurity, component availability, required prior knowledge and mental leaps. A modified version could usefully supplement mandatory MR safety training. Code, schematics, machining files and documentation are released as open source.

0.44
10

CardioState-JEPA: Delay-Aware Cross-Modal Learning of a Shared Cardiac Representation

cs.LG eess.IVstat.ML ·2026-08-13 ·Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu +1 more
Abstract

Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.

0.42