CS Paper Radar

Weekly top 10 · eess.IV

2026-W40 Sep 28 – Oct 04, 2026

Ranked from 7,028 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Reliability Stress Tests and Decision-Time Routing for Chest X-ray Vision-Language Models

eess.IV cs.CV ·2026-10-01 ·Xinye Yang, Zhusi Zhong, Scott Collins, Grayson Baird, Xuyu Wang +1 more
publishedbenchmarkcode/data
Abstract · 6 pages, 4 figures, 5 tables. Accepted version of a workshop paper presented orally at the 2026 IEEE/ACM Conference on Connected Health: App…

Medical vision-language model (VLM) evaluation is sensitive to workflow design, prompting strategy, and benchmark construction, yet most studies treat these factors in isolation. We introduce a reliability stress test for chest X-ray interpretation built on two balanced datasets (a private report-backed set and a curated MIMIC subset). Three medical VLMs (CheXagent, MedGemma-4B, and MedGemma-27B) are evaluated across three prompt styles and two workflows (single-VLM and multi-agent), producing 36 configurations. We show that exact-match accuracy alone can overstate the effectiveness of conservative models that default to "Normal" predictions. Diagnostic reliability also depends heavily on model family and scale: multi-agent reasoning helps some configurations but hurts others. Building on these observations, we propose a decision-time routing framework that selectively escalates to multi-agent inference only when beneficial, improving the cost-quality trade-off over fixed workflows. Our results highlight the need for evaluation protocols that jointly consider prompt sensitivity, failure-mode diversity, and workflow choice before clinical deployment.

0.69
2

Nonparametric Distribution Matching for Self-Supervised Whole-Slide Image Condensation

eess.IV cs.LG ·2026-09-30 ·Duong M. Nguyen, Trong Nghia Hoang, Hang Thi Nguyen, Thanh Trung Huynh, Phi Le Nguyen +1 more
top venuecode/data
Abstract · Accepted at NeurIPS 2026, SPIGM@ICML 2026

Histological whole-slide images (WSIs) are central to computational pathology but pose severe computational challenges due to their extremely high resolution, often spanning several gigabytes per slide. To enable scalable learning, existing methods apply self-supervised data condensation to reduce computational cost, but typically rely on heuristic prototype learning and do not explicitly preserve learning-relevant feature distributions for downstream tasks. In response, we introduce a principled reformulation of WSI condensation as a distribution-matching problem under a fixed representational lens, and develop NICER, a tractable approximation framework based on a nonparametric prior with slide-adaptive capacity. Experiments on five histopathology datasets, together with clinical evaluation from a board-certified pathologist, show that NICER consistently outperforms prior methods, achieving an average accuracy improvement of 7.44% while offering improved efficiency-accuracy trade-offs, highlighting the benefits of principled, distribution-aware condensation for scalable histological representation learning. Source codes are available in https://github.com/nmduonggg/NICER.

0.69
3

Salt++: Context-Aligned Post-Training for Few-Step Streaming Multimodal Generation

cs.CV cs.AIeess.IV ·2026-09-29 ·Xingtong Ge, Yutong Wang, Lunjie Zhu, Haitao Lin, Fangyu Lin +5 more
code/datahot directionhighly cited
Abstract · under review

Few-step streaming audio--video generation requires both causal modeling and step distillation, yet standard training recipes face two context-related challenges. Teacher forcing pairs clean history with a noisy target, but supervises predictive contextual representations only indirectly through velocity prediction. Meanwhile, directly reusing bidirectional score models in causal Distribution Matching Distillation (DMD) creates a mismatch between generation and scoring contexts. We address these challenges with Salt++, a two-stage post-training framework comprising Causal Self-Flow (CSF) and context-aligned autoregressive DMD. CSF exploits contextual information asymmetry by varying the history while keeping the noisy target fixed: a noise-mixed-history student aligns its intermediate representations with those of a clean-history exponential-moving-average teacher. This self-supervised signal encourages the student to extract semantic information and improves cross-modal alignment. Context-aligned AR DMD shares the causal mask and prefix across generator sampling, fake-score training, and real-score evaluation to match generated and reference distributions under a block-conditional KL objective. With calibrated teacher guidance, it performs clean-prefix few-step distillation and then adapts to generated histories without switching objectives or requiring separate consistency distillation. At 480p, Salt++ improves visual and motion quality by 57% and 45% over OmniForcing on JavisBench under the same 4-step causal setting. A separate scale-wise post-training stage extends Salt++ to 4-step $1664\times960$ generation, outperforming bidirectional LTX-2 on six of seven reported metrics. Project page: https://xingtongge.github.io/Saltpp

0.57
4

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.57
5

TIRMamba: A Thermal-Prior-Modulated State-Space Network for Sub-Million-Parameter Infrared Image Super-Resolution

eess.IV cs.CVcs.LG ·2026-10-04 ·Chun-An Lin, Tsung-Jung Liu, Yen-Chieh Ouyang
benchmarkcode/data
Abstract · 13 pages, 4 figures, 5 tables. Submitted to IEEE Transactions on Geoscience and Remote Sensing. Code and trained models will be released at …

Infrared image super-resolution is currently led by Mamba-based networks with 26 to 37 million parameters, which are difficult to deploy on the airborne and handheld platforms where thermal imaging is most needed. This paper presents TIRMamba, a network with 896K to 910K parameters for single-channel thermal imagery. A Thermal Prior Highway computes gradient, local-contrast and spectral cues once at the input and, through one adapter per residual group, modulates a weight-tied bidirectional state-space trunk and gates its dual-scale detail branch; a tri-path reconstruction adds the learned residual to a bicubic radiometric baseline. Because the standard benchmark provides only 265 infrared training images and evaluates fusion products on full images, we train with a replay strategy: grayscale DIV2K pre-training followed by fine-tuning on 64-pixel patches drawn with equal probability from the infrared and natural corpora. At scale factor 4, TIRMamba matches the strongest protocol-trained methods on both official test sets with 29 to 40 times fewer parameters and 2.8 to 9.4 times lower latency; at scale factor 2 it gives the highest SSIM on both. A variant with prior-conditioned selectivity, TIRMamba-Rad, corrects a 3 dB raw-thermal failure of an intermediate size-invariant design and gives the best results at scale factor 4 on raw-thermal, unmanned-aerial-vehicle and independent-sensor test sets. Code and trained models will be released at https://github.com/julian135707/TIRMamba upon acceptance.

0.56
6

MAV-C: A Framework for the Joint Objective Estimation of Audio-Visual Complexity in Immersive Virtual Environments

eess.AS cs.SDeess.IVeess.SP ·2026-09-30 ·Luca Resti, Amelia Gully, Michael McLoughlin, Gavin Kearney, Alena Denisova
published
Abstract · Published in AES AVARIG 2026: 6th International Conference on Audio for Virtual and Augmented Reality and Immersive Games. Available at: htt…

We present the Motion-Aware Audio-Visual Complexity Metric (MAV-C), a reference-free framework for the joint objective estimation of audio-visual complexity. The metric combines entropy-based audio features (temporal, spectral, and spatial) with visual features (Sobel gradient magnitude, chromatic uniqueness, and optical flow) via a parametric fusion stage, producing a continuous joint complexity score CAV (t) [0,1]. We validate MAV-C on two datasets: a controlled synthetic corpus (SYN) of stimuli with known signal characteristics and a naturalistic gameplay corpus (GAM) of 60 clips drawn from the SAFEPLAY-X dataset. On SYN, the metric exhibits strong validity: the audio score CA and visual score CV are each insensitive to changes in the opposite modality (CoV < 0.003), the joint score CAV spans [0.00,0.90] across all parameter combinations, and single-axis feature sweeps produce monotone trajectories (Spearman up to 0.995). On GAM, CV differs significantly across content categories (Kruskal-Wallis p = 0.021) while CA does not, and the two sub-scores are uncorrelated (r = 0.03), confirming they operate on independent signal dimensions. OFAT sensitivity analysis identifies a two-tier parameter hierarchy, with modality balance (wa) and visual regularization (v) as most significant tunable parameters. Full subjective calibration is planned as future work.

0.50
7

On Task Scope and Information Retention in Source Coding

cs.IT cs.LGeess.IV ·2026-09-29 ·Alireza Furutanpey, Kerstin Bunte
position
Abstract

We argue that dividing codec design into Coding for Machines (CfM) and Coding for Humans (CfH) is a misleading distinction for deciding what information a codec may discard. Receiver identity does not determine admissible information loss. The required rate depends on task scope, including the predictions to support, their losses and tolerated risks, the encoder observation, and the permitted decoding procedures. Notably, a machine task may have a higher minimum rate than a restricted human decision. Rate savings on selected machine tasks apply only to the stated requirements, not to an intrinsic ordering by receiver type. We extend source and feature coding to finite task families, derive when restricting the encoder observation preserves the minimum rate, and show that equality between source and split-feature coding rates can no longer hold as the task scope expands.

0.48
8

MedForge-RSI: Medical Deepfake Detection via Recursive Self-Improvement

eess.IV ·2026-09-29 ·Zhihui Chen, Mengling Feng
Abstract

Text-guided image editors can generate high-fidelity medical deepfakes, challenging the reliability of clinical imagery. Although reasoning-based detectors perform strongly in distribution, they degrade substantially under deployment shift. MedForge-Reasoner, an 8B vision-language model trained with supervised fine-tuning and reinforcement learning, achieves 99.2% accuracy on its target distribution, yet misclassifies 40% of authentic scans, reaches only 77% accuracy on unseen generators, and falls to 59% under transmission distortion. Adapting such models through conventional retraining is costly, requiring large-scale supervision and expert-designed guidelines. We introduce MedForge-RSI, a recursive self-improvement framework that enables a deployed detector to adapt while keeping its model weights frozen. Over 20 rounds, the detector analyzes verified errors, accumulates reusable experience, and autonomously develops image-analysis tools, while an independent acceptance test retains only validated improvements. Across 49 registered configurations, MedForge-RSI increases average accuracy over four test sets from 75.0% to 84.4%. On a held-out 4,000-image evaluation, it improves clean accuracy from 76.5% to 87.9% and transmission-distorted accuracy from 59.0% to 70.5%, with the largest gains in authentic-image recall. Controlled analysis across all 49 trajectories identifies which self-improvement mechanisms replicate across seeds, shows acceptance testing to be the largest individual contributor, and reveals a taxonomy of failed adaptations. We release the complete trajectories, including all rejected and rolled-back changes.

0.45
9

Spatially Gated Diffusion for Localized Counterfactual Chest Radiograph Editing

eess.IV cs.CV ·2026-09-30 ·Kamran Ullah Afaq, Basit Raza
Abstract · 16 pages, 1 figure, 10 tables

Editing a chest radiograph requires completing the requested change while preserving unrelated content. We study a latent diffusion editor with an instruction-independent source trajectory and an instruction-conditioned editing trajectory. A learned gate mixes their post-sampler candidates at each executed step, and a separate image-space mask composites the decoded proposal with the source. On 2,400 MIMIC-derived requests, 2,244 outputs met the joint target, preservation, quality, and coverage rubric (93.5%), and target completion was 97.4%. Joint validity exceeded a matched composition-only control by 1.7 percentage points (paired patient-cluster 95% interval, 0.6--2.8). At a fixed learned mask, the learned-gate proposal improved joint validity by 1.6 points (0.8--2.4); at a fixed learned proposal, the learned mask improved it by 2.6 points (1.7--3.5). Across three training seeds, mean joint validity was 93.5% with a 0.3-point sample standard deviation. A blinded 240-request assessment yielded adjudicated joint validity of 93.3% for the full editor and 91.7% for composition only. Protected-region mean absolute error decreased from 0.0190 in the raw proposal to 0.0075 after composition. These findings distinguish recurrent-gating effects on the proposal from preservation through final composition in the assessed cohort.

0.42
10

Confidence-Gated Cloud-Edge Cascade Triage via Variational Risk Minimization for Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-01 ·Xinye Yang, Zhusi Zhong, Scott Collins, Michael Bernstein, Grayson Baird +5 more
publishedcode/data
Abstract · 14 pages, 6 figures, 14 tables. Accepted manuscript of the article published in Smart Health 41 (2026) 100689. Presented as an oral at IEEE/…

Emergency chest X-ray (CXR) triage has a structural modality gap: reports arrive after triage decisions, yet multimodal foundation models require image-text inputs. We present Variational Risk Minimization (VRM), a distillation framework that treats LVLM-generated report variants as Monte Carlo samples of latent clinical interpretations. Rather than distilling from a single teacher target, VRM learns from a variationally marginalized teacher distribution, enabling uncertainty-aware supervision under missing-modality constraints. Under matched encoder families, VRM outperforms direct fine-tuning baselines and improves calibration with strong recovery from hallucinated supervision. Marginalized supervision reduces report-selection instability. In our compact edge-student instantiation, a confidence-gated cascade reaches AUC 0.941 at 103ms average latency with 20.3% cloud escalation, yielding an explicit reliability-latency operating point for cloud-edge clinical workflows.

0.42