CS Paper Radar

Spatially Gated Diffusion for Localized Counterfactual Chest Radiograph Editing

Kamran Ullah Afaq, Basit Raza

eess.IV cs.CV ·submitted 2026-09-30 22:58 UTC · v1

Abstract

Editing a chest radiograph requires completing the requested change while preserving unrelated content. We study a latent diffusion editor with an instruction-independent source trajectory and an instruction-conditioned editing trajectory. A learned gate mixes their post-sampler candidates at each executed step, and a separate image-space mask composites the decoded proposal with the source. On 2,400 MIMIC-derived requests, 2,244 outputs met the joint target, preservation, quality, and coverage rubric (93.5%), and target completion was 97.4%. Joint validity exceeded a matched composition-only control by 1.7 percentage points (paired patient-cluster 95% interval, 0.6--2.8). At a fixed learned mask, the learned-gate proposal improved joint validity by 1.6 points (0.8--2.4); at a fixed learned proposal, the learned mask improved it by 2.6 points (1.7--3.5). Across three training seeds, mean joint validity was 93.5% with a 0.3-point sample standard deviation. A blinded 240-request assessment yielded adjudicated joint validity of 93.3% for the full editor and 91.7% for composition only. Protected-region mean absolute error decreased from 0.0190 in the raw proposal to 0.0075 after composition. These findings distinguish recurrent-gating effects on the proposal from preservation through final composition in the assessed cohort.

Comment
16 pages, 1 figure, 10 tables

Closest papers

Nearest neighbours by meaning across the whole index.

From Augmentation to Synthetic Evidence: Evaluating Generated Chest Radiographs at Dataset Intake

cs.CV cs.AIcs.LG ·2026-10-21 ·Shaikh Akib Shahriyar, Zinedine Sehili, Adam Arthur, Christopher Schwartz
position similarity 0.62
Abstract

While generated chest radiographs can serve as valuable data augmentation when explicitly declared, the same pixels become unsupported evidence when submitted as records of real clinical examinations. We study this dataset-intake vulnerability by disentangling three questions: (1) whether an image passes an automated technical quality check, (2) whether an origin classifier flags it as synthetic, and (3) whether a trusted provenance record supports the claimed clinical acquisition. In this study, a submitter uses Qwen3.8-27B to select up to 20 candidate radiographs from pools of 1,000 Cheff-identified or SynthCheX images, while a receiver evaluates image quality via MedGemma 1.5 and predicts origin using a linear probe over frozen DINOv3 features. Although quality selection increases MedGemma quality passes from 12/20 to 19/20 for Cheff-identified images and from 8/20 to 17/20 for SynthCheX, we find no evidence that candidate selection increases passage through both checks simultaneously: zero selected Cheff-identified images pass both gates, and uniform, quality-guided, and surrogate-guided selection yield 2, 1, and 2 SynthCheX passes out of 20, respectively. On unprocessed test cohorts, the origin classifier rejects 4,677 of 5,000 SynthCheX images at a nominal 5% false-alarm rate (flagging 110 of 2,297 real NIH radiographs), yet leaves 152 SynthCheX images that pass both pixel-level checks. Moreover, pixel-level screening is fragile to routine distribution shifts: JPEG compression reduces SynthCheX-versus-NIH AUROC from 0.987 to 0.841, and applying the NIH-calibrated threshold to an external genuine cohort (Open-I) triggers false alarms on 568 of 957 authentic radiographs (59.4%). Because pixel-level checks can filter submissions but cannot verify clinical acquisition claims, we argue that dataset intake pipelines must record and verify source provenance independently of image pixels.

0.13

PACER: Progressive Availability-Conditioned Evidence Routing for Radiology Report Generation under Incomplete Clinical Context

cs.CV ·2026-09-28 ·Yulong Chen, Yadong Liu, Haoyu Cao, Sen Xu, Yueying Wang +1 more
similarity 0.61
Abstract · 23 pages, 2 figures, 7 tables

Radiology report generation (RRG) increasingly incorporates heterogeneous clinical evidence, such as multi-view radiographs and previous reports, whose availability varies across examinations. However, accommodating different input combinations does not ensure effective evidence use: generated reports may still omit or inaccurately describe clinically relevant findings. To address this problem, we propose PACER, a Progressive Availability-Conditioned Evidence Routing framework for structured incomplete-context RRG that follows a Refine-Calibrate-Commit pipeline. It first refines observed visual representations through endpoint-preserving patchwise routing across frozen encoder depths, incorporating complementary cues while retaining the pretrained terminal representation. It then calibrates the language-model prefix according to the observed evidence and availability state, adapting the shared generator's conditioning as the available source set changes. Finally, it generates polarity-structured clinical commitments before the report in the same autoregressive trajectory, providing structured clinical context for subsequent generation. Experiments demonstrate state-of-the-art clinical efficacy across all four MIMIC-RG4 settings and strong MIMIC-CXR performance, while maintaining competitive language-generation quality.

0.32

Rethinking Contrastive Targets in Radiology Language-Image Pretraining

cs.CV cs.LG ·2026-11-18 ·Yunhe Gao, Ashwin Kumar, Jiaming Liu, Chong Wang, Maya Varma +6 more
publishedbenchmark similarity 0.59
Abstract · NeurIPS 2026

CLIP-style contrastive image-text pretraining is widely used in radiology data, where each image is paired with one report and every other report in the batch is treated as a negative. Under this recipe, two failures appear, neither of which is systematically addressed by existing contrastive learning theory: zero-shot evaluation peaks then degrades while training loss keeps decreasing, and training fails to learn from large batches. We hypothesize the cause is structural rather than radiology-specific: many unpaired reports share clinical findings with a given image, so CLIP's paired-identity target is systematically biased, not merely noisy. To test this, we construct CLEVR-Radiology, a synthetic testbed that preserves only this overlapping-fact structure and reproduces both failures. With evidence that the structure is sufficient to reproduce the failures, we develop a target-misspecification theory that explains both failures from a single deterministic gradient bias amplified by batch size, and use it to motivate a minimal compatibility-based correction, CorLIP: text is treated as positive whenever its clinical assertions agree with the image, with no architecture changes. Beyond benchmark improvements, CorLIP largely removes the post-peak degradation, makes large-batch training succeed where it previously collapsed, substantially amplifies the gains from more data, and is the only configuration that remains stable up to B=2048. The correction transfers from chest X-ray to 3D CT modalities.

0.24

Unmentioned Checklist Findings Change How Reinforcement Learning Appears to Improve Chest Radiograph Report Checking

cs.CV cs.CLcs.LG ·2026-10-04 ·Ali Vosoughi, Akhil Kasturi, Chenliang Xu, Axel Wismueller
code/data similarity 0.58
Abstract · 40 pages, 7 figures, 17 tables (main text and references pp. 1-19; Supplementary Information as an appendix, pp. 20-40). Submitted to npj Di…

Automated checks of radiology reports may rely on AI-generated checklists that leave findings unmentioned. We used reinforcement learning to train a vision-language model to fill in a 12-finding checklist from a chest radiograph without seeing the sentence under test; a separate checking model judged the sentence from the checklist. On held-out patients, a rule-based check and an independent medical checker, neither used in training, measured discrimination gains (Youden index) of 12.6% and 11.8%; only the rule-based check met the prespecified false-alarm criterion. Switching to the training format, which fixes finding order and enters unmentioned findings as absent, raised the training checker's measured gain and lowered the independent checker's, a prespecified comparison that yielded 6.2% (95% interval 2.0% to 10.5%) and, post hoc on held-out patients, 7.7%. Across 8 checking models, acceptance of a label-consistent negative statement about an unmentioned finding ranged from 1.0% to 97.0%. Labels were report-derived, not radiologist-adjudicated.

0.54

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.58
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.15

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.57
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21

Equal Dose, Different Coverage:Tracing Rate and Duration in Image Editing

eess.IV cs.AIcs.MM ·2026-11-15 ·Yi Liu
similarity 0.57
Abstract

Benchmarks for scientific image editing test whether a model draws the outcome of a described process, leaving open which representations carry its errors and whether correcting them yields the right quantity. We study this question with an airbrush of fixed deposition profile, under which exchanging rate and duration preserves the dose and should preserve the endpoint, yet changes the edited coverage. Matched-norm activation patches across text positions and denoising stages show that, in distilled FLUX with Chinese prompts, representations at unchanged text positions (context) carry this discrepancy: early context transfers 3.51 of the 3.98 percentage-point (pp) signed route difference, against 0.09 pp for equal-norm updates at the two changed digits. Early image latents transmit native (unpatched) route differences across two FLUX configurations and OmniGen, while text-position effects depend on configuration. The trace predicts an intervention: share early context between routes while each retains its own digits. On independent English layouts, this reduces the distilled-FLUX absolute route gap from 1.13 to 0.60 pp, outperforms early digit sharing, and improves agreement more than in base FLUX under directly paired tests. Calibrated evaluation, which prescribes an area for each dose, separates this gain from accuracy: sharing the full prompt encoding produces identical route images with target errors of 8-16 pp, and stating the target percentage directly retains a compressed area response. Localization predicts a consistency gain on new layouts, and calibration measures the quantity error that agreement leaves unresolved.

0.29

When Repository Labels Are Not Image-Level Truth: A Supervision Auditing Framework for Chest Radiograph AI

eess.IV cs.CV ·2026-08-10 ·Yesika Alexandra Agudelo-Londoño, Jhon Wilmer Pino-Román, Brahian Carrera Rodríguez, José Miguel Castañeda-Bedoya, Juan Pablo Gómez-López +7 more
published similarity 0.57
Abstract · Accepted (oral) at the 3rd MICCAI Student Board (MSB) EMERGE Workshop, MICCAI 2026. This is the authors' version; the final authenticated ve…

Public chest X-ray repositories are widely used to train medical AI systems, yet their labels are typically extracted from radiology reports rather than verified directly on images. As a result, repository labels are often treated as image-level ground truth without validating whether they reflect what is actually visible in the radiograph. We introduce Repository Supervision Auditing (RSA), a framework that evaluates repository-derived labels against expert image-level annotations before model development. Using cardiomegaly in MIMIC-CXR as a case study, RSA compares repository labels with radiologist-reviewed image annotations, characterizes disagreement sources, and builds a curated cohort for deployment-oriented evaluation. Repository-derived cardiomegaly labels showed near-zero agreement with expert image-level assessment, identifying only 1% of expert-confirmed cases. Most discrepancies resulted from non-mention rather than explicit report negation, with expert-confirmed cardiomegaly identified in nearly half of studies assigned a repository-derived No Finding label. Using the resulting expert-curated cohort, a DenseNet121 model achieved a test ROC-AUC of 0.853. These findings show that repository labels may not reliably represent image-level truth and highlight supervision auditing as a critical step for developing trustworthy medical imaging AI.

0.24