CS Paper Radar

Weekly top 20 · eess.IV

2026-W42 Oct 12 – Oct 18, 2026

Ranked from 5,357 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

Codec-Compatible Learned Compression for 3D Gaussian Splatting

eess.IV cs.CV ·2026-10-17 ·Feiyang Yu, Qi Yang, Wenjie Huang, Yunfeng Guan, Yiling Xu +1 more
published
Abstract · Accepted at the IEEE International Conference on Visual Communications and Image Processing (VCIP 2026). 5 pages, 3 figures, and 1 table

Video-based 3D Gaussian Splatting (3DGS) compression methods provide a practical route by representing Gaussian attributes as 2D maps and coding them with standard video codecs. Among these maps, high-dimensional non-DC spherical harmonics (SH-AC) maps contain the largest number of channels and account for a dominant portion of the bitstream. However, their statistics differ substantially from those of natural images, and the nonlinear dependencies among SH-AC coefficients remain insufficiently exploited. To address these issues, we propose CCT-GS, a Codec-Compatible learned Transform framework for 3DGS compression. CCT-GS first learns a generalized SH-AC transform that captures cross-scene regularities and converts SH-AC maps into compact codec-friendly bottleneck maps. It further introduces LoRA-based scene adaptation to recover scene-specific appearance details with lightweight side information. Experiments on MPEG GSC sequences demonstrate that CCT-GS consistently outperforms representative video-based baselines, achieving an average BD-rate reduction of 51.30% over the video-based anchor.

0.54
2

LUMINR: Intensity-conditioned Meta-learned INRs for Accelerated Medical Image Registration

eess.IV cs.CV ·2026-10-16 ·Damian Rynczak, Marek Wodzinski
hot direction
Abstract · 13 pages, 7 figures, 3 tables

Implicit neural representations (INRs) have been applied to deformable image registration, where a lightweight network maps a spatial coordinate to a deformation vector. Because an INR encodes one specific signal in its parameters, a fresh network must be optimized for every image pair at test time, which is slow. Existing methods reduce this cost by meta-learning an initialization across a population of image pairs, and condition the weights of the INR globally, so the same conditioning applies at every coordinate while the deformation field it initializes varies across the domain. We propose LUMINR, a meta-learning framework that accelerates this per-pair fitting and in which the conditioning is local instead. LUMINR uses an INR that maps a coordinate, together with local intensity and gradient features, to a deformation vector, so the conditioning varies over the domain at the resolution of the field being modelled. Its objective is to find an initialization of the INR parameters from which the network can be fine-tuned to register any unseen pair in only a few optimization iterations. We evaluate LUMINR on 3D deformable registration of brain MRI from the OASIS dataset, where local conditioning and the meta-learned initialization prove complementary: early in fitting they reach a markedly higher accuracy than either does alone. Fine-tuned from that initialization, LUMINR matches the accuracy of the same conditioned INR fit from scratch in roughly a tenth of the gradient steps and a tenth of the wall-clock time, while the deformation fields stay smooth with negligible folding.

0.50
3

Simplifying and Improving On-Policy Distillation for Few-Step Diffusion

cs.CV cs.LGeess.IV ·2026-10-13 ·Jiawei Zhang, Ziyu Wan, Nanye Ma, Long Zhao, Dong Chen +3 more
code/datacommunity pick
Abstract · Project Page: https://zjwfufu.github.io/SMD-Page/

Few-step distillation reduces the sampling cost of diffusion and flow models, but existing approaches often require auxiliary score models or specialized architectures. We show that simple on-policy velocity regression already provides a strong foundation for 4-NFE generation. To represent teacher velocity variation within each coarse transition, we introduce Pivot, a training-only residual proxy that separates local corrections from the student's interval-mean prediction. We further repel the student from weaker teacher predictions, providing a lightweight mechanism for avoiding undesirable modes. The resulting framework, Simplified Matching Distillation (SMD), remains entirely regression-based, requires neither online score estimation nor adversarial training, and leaves the deployed generator unchanged. We evaluate SMD on image generation and editing, 3D generation, video synthesis, and joint audio--video generation, scaling to 33 billion parameters. At 4-NFE, SMD outperforms strong few-step baselines and surpasses multi-step teachers on several benchmarks. It also supports cross-model, multi-teacher, and causal-video distillation.

0.49
4

Monotone Piecewise-Linear Harmonization of Multitemporal Multispectral Surface Reflectance With Unsupervised Deep Multiview Pseudoinvariant Features Learning

eess.IV cs.CV ·2026-10-15 ·Lino Garda Denaro, Chia-Hsiang Lin
Abstract · 15 pages, 5 figures

Surface reflectance products derived from optical satellite may exhibit systematic inconsistencies across acquisition dates, because atmospheric correction is generally performed independently for each image. Such residual biases distort the temporal behavior of invariant ground targets and reduce the reliability of multitemporal surface reflectance analysis. This study proposes Deep Multitemporal Generalized Canonical Correlation Analysis (DeepMGCCA), an unsupervised deep multiview pseudoinvariant feature learning framework that integrates Deep Generalized Canonical Correlation Analysis (GCCA) with Multivariate Alteration Detection (MAD) to identify deep-pseudoinvariant features (DIFs) for the removal of surface reflectance biases across multitemporal satellite observations. Unlike conventional MAD-based approaches that rely on linear GCCA, the proposed framework replaces date-specific linear projections with a shared convolutional encoder. The framework learns deep invariant features (DIFs) directly from pixel-weighted canonical variates via iterative reweighting strategy, while a reconstruction regularizer preserves surface reflectance information and prevents degenerate collapse from suppressing genuine temporal variability. Experiments were conducted on four annual Landsat-8/9 and Sentinel-2 acquisitions across four regions of interest (ROIs) to evaluate four DIF-based harmonization transforms. A monotone piecewise-linear transform derived from DIFs quantiles consistently achieved the largest bias reduction, lowering the between-date spectral angle by up to 2.54 and RMSE by 0.015, and raising PSNR by up to 4.04~dB. These findings demonstrate the potential of deep invariant feature learning for multitemporal surface reflectance bias removal while highlighting the importance of preserving physically meaningful temporal and spectral information during nonlinear representation learning.

0.47
5

Evidence Field for Histopathology: Cross-Centre Evaluation and Replayable Spatial Decisions

eess.IV ·2026-10-15 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
Abstract · 8 pages, 4 figures

Histopathology classifiers must transfer across acquisition sites while exposing evidence that can be checked independently. Evidence Field couples learned image measurements and spatial classification with a native covering-program record. We evaluate this architecture on all 455,954 released CAMELYON17-WILDS patches, using patient-separated source partitions and two held-out hospital centres. Eighteen from-scratch fits compare four Evidence Field objectives with residual convolutional and compact vision-transformer classifiers. Checkpoints, temperatures and review thresholds are selected using source validation. The source-selected paired-cross-entropy ensemble achieves areas under the receiver operating characteristic curve of 0.9356 and 0.9453, with accuracies of 84.46% and 86.77% at the two held-out centres. Corresponding convolutional values are 0.7352 and 0.7656, and transformer values are 0.8502 and 0.7924. Evidence Field has 10,550 trainable parameters per member and additionally returns selected covers, signed region and interaction terms, contextual dependencies and independently reconstructible predictions. Patient-cluster intervals, calibration, source-fixed review policies and recorded training resources characterize the results. A 340-image, three-member audit reconstructs probability mixtures and 6,120 class programs under three rigid views. The evaluation supports cross-centre discrimination and reproducible computation for these implemented models; unequal family tuning, previously examined public targets and limited patient groups constrain broader interpretation.

0.47
6

Case-Specific Priors-Guided Multimodal Fusion for Prognosis Prediction in Head and Neck Cancer

eess.IV ·2026-10-15 ·Yue Lin, Shuchang Ye, Shenghai Wu, Dashun Zheng, Mingyuan Meng
top venuecode/data
Abstract · Accepted at MICCAI 2026

Accurate prognosis prediction for head and neck cancer typically necessitates integrating highly heterogeneous clinical and pathological evidence by sophisticated multimodal fusion. However, existing fusion techniques are usually grounded in case-generic clinical rationales about complementary synergies across modalities, underestimating case-specific variance. In this study, we propose a prognosis prediction framework that explicitly incorporates Case-specific Priors to guide Multimodal fusion (named CPM). It leverages broad medical knowledge of LLMs to characterize each case's (case-specific) intra-modal contexts and inter-modal relations, as well as case-generic multimodal rationale, as priors, enabling three-stage priors-guided multimodal fusion: (i) Intra-modal Context-guided Calibration (IntraCC) that leverages case-specific intra-modal priors to guide feature calibration within each modality; (ii) Inter-modal Relation-guided Interaction (InterRI) that leverages case-specific inter-modal priors to guide pair-wise feature interaction in modality pairs; and (iii) Multimodal Rationale-guided Aggregation (MultiRA) that leverages case-generic multimodal priors to guide final feature aggregation over all modalities. On the well-established HANCOCK challenge dataset involving four distinct medical modalities, our CPM achieved a mean AUC of 83.98% for predicting 5-year overall survival and 2-year recurrence-free survival, improving upon the baseline by 7.58%, pioneeringly demonstrating the effectiveness of LLM-derived medical priors in guiding multimodal fusion for prognosis prediction. The code is available at https://github.com/yuelin421/CPM.

0.46
7

Deficit-Driven Stratified Acquisition for Building STRATA-S12: An Open SAR-Optical Corpus for Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-10-13 ·Christian Sanchez-Leon, Dongming Chen, Dongqi Wang
Abstract · v3: substantially revised. The ordering analysis is now a replay over all 2,928,370 real acquisition attempts (deficit-driven vs. round-robi…

Building a co-registered SAR-optical corpus for self-supervised Earth Observation is above all an acquisition problem, yet the main multi-modal datasets are collected opportunistically, with no per-stratum quota control, so the regions and seasons that cloud cover hits hardest end up under-sampled. We present Deficit-Driven Stratified Acquisition (DDSA), an algorithm that casts the construction of a Sentinel-1/Sentinel-2 corpus as a constrained maximum-coverage problem over a land-cover-driven, hemisphere-corrected (class x season x region) stratification of target countries on all six inhabited continents, and solves it online: acquisition is ordered by marginal gain against a per-stratum deficit that the quality gates and a visual review of every accepted pair keep updating during the run. Three results follow from measuring the algorithm on its own product. First, stratum balance is a property of the deficit-driven ordering rather than of run length: replayed over all 2,928,370 real acquisition attempts, failures included, it populates all 192 strata within 0.05% of the attempts, against 4.03% for uniform round-robin effort and 20.5% for a random order. Second, whether a rejected attempt can be recovered is better predicted by how long its cause persists than by the type of defect: cloud rejections are recovered at eta = 18.8% against 41.4% for nodata, consistent with clouds persisting through a season. Third, the repair loop supplies 39.5% of the released pairs at no measurable quality cost, with 89.8% surviving manual review, but it adds yield rather than balance. The quality guarantee has a price: 2,928,370 acquisition attempts produced 740,746 released pairs. We release the corpus, STRATA-S12, with per-pair metadata sidecars aligned with the STAC and PDS4 standards and the FAIR principles, and a pre-registered linear probe confirms it is fit for self-supervised pre-training.

0.45
8

Deep Learning for Atmospheric Turbulence Mitigation: A Comparison Between GANs and Transformers

eess.IV cs.CV ·2026-10-13 ·Juan S. Carrillo, Jérôme Gilles
publishedhot direction
Abstract · Published in the Journal of Electronic Imaging

Atmospheric turbulence creates complex spatial and temporal distortions that significantly reduce image quality. This work compares two deep learning methods for turbulence reduction: Generative Adversarial Networks (GANs) and Transformer-based models. Both methods are trained and tested on the SOTIS dataset, which includes multi-frame sequences under different turbulence conditions with ground truth references. Our results show an important finding: GAN-based models perform better in severely degraded, low-quality situations, while Transformer-based models achieve better results in moderate to high-quality settings, especially in correcting geometric distortions. We also enhance the Turbulence Mitigation Transformer (TMT) by introducing a refined training strategy, an augmented input design that includes a temporally averaged frame as prior structural information, and a modified loss function that incorporates the Structural Similarity Index (SSIM). These improvements lead to consistent performance gains across various turbulence conditions. Overall, this study provides an in-depth evaluation of deep learning methods for turbulence reduction and offers practical guidance for selecting models in different imaging environments.

0.44
9

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

eess.IV cs.CVq-bio.TO ·2026-10-12 ·Quan Wang
benchmarkcode/data
Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

0.37
10

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37
11

Severity-Channel Conditioning: An Injection-Level Study for Consumer-Device Deblurring

eess.IV cs.AIcs.CVcs.LG+1 ·2026-10-17 ·Abdullah Al Shafi, Kazi Saeed Alam, Sumaiya Rahim Suma, Sk. Imran Hossain
benchmarkcode/data
Abstract · 17 pages (12 main + 5 supplementary), 7 figures, 14 tables. Code: https://github.com/C-loud-Nine/Severity-Channel-Conditioning

Motion-deblurring models lose substantial accuracy when transferred from professional cameras to smartphone-derived imagery. This paper studies whether a severity descriptor, partly derived from the paired sharp target, helps adaptation on the iPhoneBlur consumer-device benchmark. Under a shared update budget, input concatenation of a severity map is compared with global feature modulation by capture metadata, spatial feature modulation by the severity map, and a tier-contrastive output objective, together with an unconditioned spectral-loss control, all fine-tuned from the same domain-adapted latent-diffusion baseline. The primary experiment is an oracle diagnostic: target-derived information is supplied at inference. For the evaluated model pair, input concatenation improves overall peak signal-to-noise ratio from 31.23 to 31.30 dB, whereas feature modulation, the contrastive objective, and the spectral-loss control do not exceed the baseline. The gain is positive on 87.2% of test images and on 14 of 15 held-out source videos; this video-level analysis describes the evaluated checkpoint pair and does not establish robustness to retraining, and three training seeds are reported separately. The input-level gain recurs on a transformer backbone. In one exploratory run, zeroing the channel at inference retains most of the gain in peak signal-to-noise ratio but lowers structural similarity below the baseline. A normalized-step diagnostic does not support the expected larger-gradient explanation. The results characterize the evaluated configurations and do not establish injection location as the sole cause, a spatial-locality mechanism, or a reliable deployment advantage.

0.36
12

Evidence Field: Adaptive Covering Programs for Medical Imaging

eess.IV cs.AIcs.CVcs.LG ·2026-10-17 ·Isarar Siddique, Raiyan Siddique, Arshi Niyaz, Jamyang Ugyen Tshomo, Atish Raza
Abstract · 9 pages, 5 figures

Medical image classifiers typically return predictions without a native contract for independently reconstructing their spatial decision computation. Evidence Field is a trainable spatial-program architecture that jointly produces class scores, selected covering programs and signed evidence. Its encoder combines absolute and image-relative response fields with associative spatial moments and learned characteristic sums. A typed classifier scores individual regions and parent-conditioned multiplicative groups; a covering recursion selects scale, partition and composition. We establish exact one-fold coverage, optimality within the registered grammar, a bound relating smooth training to hard inference, signed-score conservation and class-centred offset invariance. Direct contractions and their adjoint specify arithmetic and storage scaling on two- and three-dimensional grids. Native output records bind inputs, parameters, supports, types and contextual dependencies to individual and ensemble predictions. In a separately reported histopathology application, patient-separated training and evaluation across held-out centres provide empirical evidence for the architecture. Trained mechanism and corrected-loss comparisons distinguish predictive effects from implementation correctness; independent readers reconstruct descriptors, routes, scores and probability mixtures. The principal contribution is a coupled representation, decision and evidence architecture whose selected computation can be reproduced independently.

0.36
13

napari-TurboBox: Interactive Multi-Viewer Bounding Box Annotation for AI-Guided Volumetric Bioimaging

eess.IV q-bio.QM ·2026-10-14 ·Nils Friederich, Philip Kohle, Maximilian Beichter, Mona Wellhäusser, Marcel Stahl +9 more
code/dataunusual
Abstract · 6 pages, 3 figures

Promptable segmentation models turn one 3D bounding box into an instance mask. Box placement therefore limits how fast microscopy volumes with thousands of objects are annotated. Each box must be checked in several synchronized viewers, but napari-bbox shares no state between viewers. An edit must update every viewer and slows down with more boxes. napari-TurboBox instead holds one shared copy of the boxes for all viewers. In a four-viewer layout, napari-TurboBox needs a few milliseconds per mouse move to update the three slice viewers up to $10^4$ boxes. The same update in napari-bbox leaves the 33 ms budget beyond about $10^3$ boxes and takes 159 ms at $10^4$. Boxes stay axis-aligned and export to COCO and YOLO as per-slice 2D boxes. napari-TurboBox is a pure-Python plugin for napari 0.6.6 to 0.9. The code is available at https://github.com/N-Friederich/napari-turbobox under the Apache 2.0 licence, and version 0.1.0 is archived at https://doi.org/10.5281/zenodo.23090828 on Zenodo.

0.35
14

Measurement-Adaptive Light-Cone Transform for Robust Non-Line-of-Sight Imaging

eess.IV cs.CV ·2026-10-16 ·Lianfang Wang, Xueying Liu, Junnan Dong, Qinghua Zhang, Jun Liu +2 more
published
Abstract

Practical non-line-of-sight (NLOS) measurements are affected by noise and deviations from idealized light transport, which can degrade reconstruction with conventional light-cone transform (LCT) methods. We propose the Measurement-Adaptive Light-Cone Transform (MALCT), a physics-guided framework that retains the efficient Fourier-domain inversion structure of LCT. {Within a unified variational formulation, MALCT combines the analytical response with a shared learned response through measurement-conditioned weighting and predicts a measurement-conditioned, frequency-dependent regularization map.} An attention-enhanced spatio-temporal feature extraction module captures long-range temporal dependencies and local spatial correlations to support reconstruction under low-signal conditions. Experiments on synthetic data and real measurements from different NLOS systems demonstrate improved reconstruction quality. Controlled evaluations further assess robustness to temporal-response broadening and reduced acquisition time. MALCT also preserves scene structures with spatial sampling grids down to $32\times32$, supporting its potential for NLOS imaging under limited acquisition budgets.

0.35
15

Image Moment Estimation for Crowded Datasets

eess.IV q-bio.QM ·2026-10-16 ·Andy Zhang, Oscar Mickelin, Amit Singer
Abstract · 29 pages, 11 figures

Single-particle cryogenic electron microscopy (cryo-EM) is an imaging technique capable of reconstructing high-resolution three-dimensional (3D) structure of biological macromolecules from a set of noisy projection images taken at random viewing directions. The mathematical model for cryo-EM images typically assumes that each image contains exactly one particle, which is centered at the origin. However, many experimental datasets contain particle images which include multiple particles: one central particle and a few crowding particles. This deviation from the model leads to inaccurate estimation of image statistics, such as the low-order image moments. To account for this, we propose a method to estimate image moments while correcting for the effect of crowding particles. This method can be run directly from a set of cryo-EM micrographs with picked particles, and we demonstrate its efficacy on a wide array of synthetic data.

0.35
16

Focus, Align, and Diffuse: Time-Series-Aware Keyframe Diffusion for Cardiac Dynamic Synthesis from Sparse Observations

eess.IV cs.CV ·2026-10-13 ·Junkai Liu, Haofan Wu, Nay Aung, Joao A. C. Lima, Steffen E. Petersen +1 more
publishedcode/data
Abstract · NeurIPS 2026. Project page: https://cardiofad.github.io/

Dense cardiac dynamics are essential for assessing cardiac function, yet in practice clinicians often observe only extremely sparse measurements. However, recovering full dynamics from such sparsity is a highly ill-posed problem due to the lack of temporal cues. While auxiliary time-series signals like ECG provide physiological guidance, effectively exploiting them is challenging due to the cross-modal representation gap and phase misalignment. In this work, we present CardioFAD, a Focus--Align--Diffuse paradigm that reformulates sparse cardiac dynamic synthesis as a recoverability--alignability anchor discovery problem. Our core insight is that resolving extreme temporal ambiguity requires a compact set of anchor states that are both sufficient to recover the visual trajectory and reliable for ECG--visual alignment. We therefore learn motion-salient keyframes under two complementary principles: trajectory sufficiency, which preserves trajectory-critical intra-modal motion content, and anchor alignment, which promotes consistent inter-modal correspondence at these anchors. We implement the Focus and Align modules optimized by the two aspects. Diffuse then performs two-stage generation by first synthesizing keyframes and subsequently interpolating the remaining frames. Extensive experiments on cardiac MRI and echocardiography videos demonstrate superior visual quality, temporal coherence, and improved functional consistency under the extreme one-shot regime.

0.33
17

Calibrating Generative Flows through Regional Probability Matching

eess.IV ·2026-10-12 ·Yubo Huang, Xiongyu Hu, Xin Lai, Zixi Wang, Liao Jian +2 more
benchmarkhot direction
Abstract

Generative models offer a powerful route to scientific simulation and discovery by enabling the study of complex populations and rare phenomena. Flow matching can generate realistic samples, yet inaccurate occurrence frequencies can distort population statistics and compromise inferences about rare events. Here we developed generalized mass-preserving coupled flow matching (G-MPCF), which matches the probability masses of Gaussian source regions to those of weighted data regions. This construction encodes the desired regional frequencies in the correspondence between noise and observations, shaping the learned dynamics while preserving the prescribed target distribution. On a rare-mode benchmark, G-MPCF reduces relative score error by 95.0% and numerical integration error by 89.9% compared with independent flow matching. On CIFAR-10 with a 100:1 class-probability ratio, it reduces corrected class-mass error by 44.6% compared with minibatch optimal transport, while improving mean image fidelity with matched computational budgets. We envision that incorporating regional probability calibration into generative modelling will support more reliable scientific simulation and inference, enabling the study of systems in which rare events and their occurrence frequencies are central to understanding the underlying mechanisms.

0.32
18

Really Need Recursion? Revisiting One-pass Registration with Multi-level Multi-space Contextual Guidance

eess.IV cs.AI ·2026-10-15 ·Yue Lin, Shenghai Wu, Mingyuan Meng
top venue
Abstract · Accepted at MICCAI 2026

Deformable image registration is a fundamental challenge in medical image analysis. Recent deep learning-based methods typically adopt either one-pass architectures that complete registration in a single network iteration, or recursive architectures that refine registration through multiple passes. While recursive methods often improve accuracy, they incur substantial computational overhead and slower inference speed. In this paper, we challenge the necessity of recursion for high-performance deformable registration and propose M2CG, a one-pass registration network with Multi-level Multi-space Contextual Guidance. It performs multi-step progressive pyramid registration within a single iteration, guided at each step by contextual cues from three levels (previous, current, and subsequent steps) and four spaces (image space, image feature space, segmentation space, and segmentation feature space). Our M2CG supports both unsupervised (without any labels) and semi-supervised (with segmentation labels for partial training data) registration, and has achieved state-of-the-art performance across two well-benchmarked inter-/intra-patient medical registration tasks with eight public datasets. Our findings suggest that the current reliance on recursion may stem from the absence of sufficient contextual cues that comprehensively characterize the remaining distance to the target alignment.

0.31
19

Implicit Neural Models for Direct Multi-Shell Diffusion MRI Signal Estimation

eess.IV cs.CV ·2026-10-16 ·Sanna Persson, Fabian Leander Sinzinger, Christoffer Olsson, Rodrigo Moreno
Abstract · 23 pages (9 pages main text + supplementary material), 9 figures, 18 tables

Diffusion magnetic resonance imaging is a noninvasive technique that is sensitive to the motion of water molecules in human tissue. The image signal is commonly described in q-space; however, a complete coverage of this space is often infeasible due to hardware and acquisition time limitations. In this work, we propose to represent the entire diffusion signal using an implicit neural representation network with wavelet activation functions. The signal space is encoded using Fourier features and spherical harmonics basis functions for a continuous output distribution of the raw diffusion data, enabling both super-resolution and q-space interpolation. Additionally, we introduce a pretraining strategy using a group template, enabling faster per-subject optimisation when combined with nonlinear registrations of subjects into template space. We tested the method with 10 subjects from the Human Connectome Project and 26 subjects from in-house data (multidimensional diffusion MRI from a Parkinson's disease cohort). The results show that the proposed method yields high-fidelity reconstructions with significantly reduced memory requirements compared to raw diffusion-weighted images. The pretraining scheme showed good generalisability properties on data acquired with very different protocols. We further assess the method on downstream metrics relevant to diffusion MRI data from the learned representations.

0.31
20

Augmenting Real-time Visualization in Minimally Invasive Surgery with Particle Filtering and Depth-Aware Occlusion Handling

eess.IV cs.RO ·2026-10-13 ·Anuska Sarkar, Partha Acharya, Vishnu Nandury, Kaustav Basu, Subhamoy Mandal
top venue
Abstract · Accept

We present a real-time, hybrid framework for occlusion handling and depth-aware tracking in minimally invasive surgeries (MIS). Occlusions caused by surgical instruments often obscure the region of interest (ROI), affecting surgical precision. To address this, our approach integrates enhanced You Only Look Once (YOLO) based detection, Particle Filtering (PF), and monocular depth estimation using Multiple Depth Estimation Accuracy with Single Network (MiDaS). Occlusion is detected using a distance-based threshold between instruments and ROI. Experimental results demonstrate robust instrument detection with a confidence score of 0.85, effective occlusion event handling, and accurate depth prediction with an MAE of 0.34 cm and RMSE of 0.53 cm. Independent phantom-based validation against stereo depth measurements yielded an MAE of 0.65 cm and RMSE of 0.66 cm. The framework further achieved an occlusion detection accuracy of 81.95\% while maintaining real-time performance at 38.7 FPS. Preliminary surgeon feedback indicates that the proposed visualization framework is clinically relevant and holds promise for future intraoperative image-guided navigation and decision support in MIS.

0.31