CS Paper Radar

Daily listing

2026-08-25 · eess.IV

6 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 6

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

Learning spatially varying regularisation parameters of low regularity for image reconstruction

eess.IV cs.CVmath.OC ·2026-08-25 ·Kostas Papafitsoros, Luca Calatroni, Andreas Kofler
Abstract

In this chapter, we review and discuss the regularity properties of spatially adaptive regularisation weight functions used in variational image reconstruction. Incorporating such weights into classical model-based regularisers, such as Total Variation (TV) and Total Generalised Variation (TGV), allows the regularisation strength to vary across the image and adapt to local image content. When appropriately estimated, these weights can thus significantly improve edge and detail preservation in the reconstructions. We review the existing theoretical literature on this topic for different regularity classes, including constant, continuous, and piecewise constant functions. Our discussion is motivated by recent work on hybrid image reconstruction methods that combine model-based regularisation with deep neural networks to learn highly adaptive regularisation weights. In particular, we discuss how the structural properties of these weights influence the reconstruction from both theoretical and practical perspectives. Through representative examples in image denoising and magnetic resonance imaging (MRI) reconstruction, we demonstrate that the learned weights are often of low regularity and can adapt not only to the image structure but also to the specific noise realisation. We conclude by highlighting several directions for future research on this topic.

0.45

Lowering the Barrier to AI-Driven Inspection: A No-Code Workflow for Automated Structural Defect Detection

cs.CV cs.LGeess.IV ·2026-08-25 ·Michael Holm, Tanner McElroy, Xinghang Zhang, Guang Lin
publishedcode/data
Abstract · 11 pages, 7 figures. Accepted to ASME SMASIS 2026 (paper SMASIS2026-190654). Software available at https://github.com/michaelholm6/YOLOEZ

Structural health monitoring (SHM) is essential in modern engineering, providing data for condition-based maintenance, lifecycle assessment, and predictive decision-making. Traditionally, SHM relied on visual inspection to detect defects such as cracks and deformations. Early computer vision (CV) methods, including thresholding, edge detection, and handcrafted features, aimed to automate this process but were highly sensitive to noise, imaging variations, and multiscale defects, limiting their reliability. Recent advances in machine learning, particularly convolutional neural networks (CNNs) and You Only Look Once (YOLO), have improved defect detection accuracy and enabled real-time analysis. However, adoption in SHM remains limited due to technical barriers such as data labeling, model training, and deployment, which typically require programming expertise. To address this gap, we introduce YOLOEZ, an open-source, GUI-based tool for end-to-end YOLO model application. YOLOEZ integrates data labeling, training, and inference into a single interface, enabling high-performance model development without code while supporting reproducible workflows. Evaluation against existing software and classical image processing demonstrates that YOLOEZ not only outperforms traditional methods across most detection metrics, but also lowers adoption barriers present in other modern CV tools. By combining accuracy with accessibility, YOLOEZ facilitates wider use of AI-driven monitoring for predictive maintenance, digital twins, and intelligent structural systems.

0.42

Unified-protocol voxel-level pulmonary embolism annotations for three public CT angiography datasets

eess.IV cs.CV ·2026-08-25 ·Qihang Sun, Zhongxiao Liu, Bailiang Jian, Shenman Qiu, Jingyuan Wang +4 more
Abstract · 18 pages, 5 figures, 1 table

Reliable clot-volume quantification and subsequent risk assessment in pulmonary embolism depend on precise segmentation of emboli on computed tomography pulmonary angiography. Deep learning models for this task must be trained on accurate voxel-level labels. The three public datasets that provide such labels were annotated under different protocols, and some of their studies contain unlabeled emboli or labels that are discontinuous across slices. This Data Descriptor presents voxel-level pulmonary embolism annotations for 149 of the 166 studies in these datasets. A primary rater drew all annotations under a single protocol. A thoracic radiologist with more than 20 years of experience reviewed and revised them. Three raters at three different centers independently annotated a subset of 15 studies. The subset was selected by source dataset and embolus location. Technical validation quantifies volumetric agreement with the source annotations, changes in within-mask attenuation, and inter-rater agreement on the subset. The dataset is intended to allow segmentation models to be developed and compared under a common reference standard.

0.37

Effects of Quantum Noise and Source Blurring on Dark-Field Signal Retrieval in X-ray Speckle-Based Imaging

eess.IV physics.opticseess.SPphysics.ins-det+1 ·2026-08-25 ·Hunwoo Lee, Jingcheng Yuan, Mini Das
unusual
Abstract · 18 pages 9 figures

X-ray speckle-based dark-field imaging offers high sensitivity to sub-pixel structural features, yet its quantitative reliability in clinical and preclinical settings remains constrained by low photon flux and finite focal spot sizes. However, how hardware-induced noise and source blurring propagate through retrieval algorithms to degrade signal integrity is not fully understood. Here, we systematically evaluate algorithm robustness quantified by signal linearity, sensitivity, and bias under photon starvation and source blurring across two mathematically distinct frameworks: differential-based intrinsic tracking (Low-Coherence System, LCS) and patch-wise explicit tracking (X-ray Speckle-Tracking Speckle-Vector-Tracking, XST-XSVT). Our experimental results demonstrate that input speckle pattern distortions propagate through retrieval algorithms in fundamentally different ways depending on algorithm architecture. As an example, using our setup, under severe photon starvation, derivative noise amplification in LCS causes its dark-field signal linearity and sensitivity to drop precipitously, while sharply elevating baseline bias. In contrast, XST-XSVT restricts these losses for sensitivity while maintaining a stable baseline, as its patch-wise variance calculation inherently suppresses stochastic noise. Similarly, under blur-limited conditions , source blurring washes out the speckle pattern, directly reducing dark-field sensitivity for both LCS and XST-XSVT. This characterization establishes operational boundaries for low-power and low-coherence X-ray systems, guiding algorithm selection and framework optimization to realize quantitative dark-field imaging in preclinical and clinical applications.

0.28

Score-Based Ideal Observer Approximation via Denoising Score Matching for Signal-Known-Exactly Detection Tasks

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-25 ·Weimin Zhou
theoryunusual
Abstract · Submitted to SPIE Medical Imaging 2027

The Bayesian Ideal Observer (IO) establishes the theoretical upper bound on task performance for binary detection tasks. However, analytical computation of the IO test statistic is generally intractable. Numerical approaches based on Markov-chain Monte Carlo (MCMC) methods, including their recent deep generative model-based extensions, typically require extensive posterior sampling for each test image. Supervised learning has also been investigated to approximate the IO performance. However, such methods are typically trained for a specific detection task and signal and may require retraining when the task or signal changes. The score function, defined as the gradient of the log probability density, encodes the local geometry of the data distribution and is a fundamental quantity in modern score-based generative modeling. This work reformulates the IO test statistic in terms of the score function and introduces a score-based ideal observer (SIO). The proposed SIO uses a denoising convolutional neural network trained exclusively on signal-absent images to estimate the signal-absent score function. Once trained, the resulting score model can be used to approximate the IO test statistic for detection tasks involving arbitrary additive signals, without per-image posterior sampling or signal-specific retraining. Numerical studies consider a signal-known-exactly (SKE) detection task with a stochastic lumpy-background model. The results demonstrate that the proposed SIO can closely approximate the IO performance.

0.25