CS Paper Radar

Daily listing

2026-09-11 · eess.IV

11 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 11

LM-PCVMNet: Pediatric Cervical Vertebral Maturation Analysis with Deep Fusion of Landmarks and Metadata

eess.IV cs.CV ·2026-09-11 ·Peng Wang, Wanzhen Song, Anli Wang, Xueshuo Xie, Xiaohang Guan +1 more
publishedcode/data
Abstract · 12 pages accepted by Information Fusion

Cervical vertebral maturation (CVM) assessment plays a pivotal role in orthodontic diagnosis and determining the optimal timing of treatment, especially for pediatric patients. In this paper, we propose LM-PCVMNet, a novel deep learning framework for automatic pediatric CVM staging. Specifically, our method integrates vertebral anatomical landmark information, heatmap-guided feature modulation, and metadata-informed similarity modeling into a unified learning framework. We introduce a heatmap-guided feature modulation module that enhances feature extraction by leveraging landmark-centered heatmaps to highlight morphologically relevant vertebral regions. A vertebral landmark-prompting block is designed to incorporate anatomical geometry into the representation learning process. Furthermore, we develop a learnable metadata supervised contrastive loss that adaptively modulates positive-pair similarity based on metadata similarity, enabling the model to learn more biologically consistent and discriminative features. To facilitate further research in pediatric orthodontic treatment, we additionally release PCVM+. It contains 1800 lateral cephalometric radiographs from real-world patients aged 3-15 years, with expert-annotated CVM stages, 13 vertebral anatomical landmarks, and corresponding metadata. We perform comprehensive experiments on two datasets, and the results show that our method achieves state-of-the-art performance, effectively improving landmark localization and classification accuracy over existing models. Code and dataset will be available at github.com/ybupengwang/LM-PCVMNet.

0.63

Tile-Based Phase Unwrapping with Reliability-Ordered Joining and Residual-Weighted Multipath Averaging

eess.IV cs.CV ·2026-09-11 ·Antoine Moevus, Max Mignotte
unusual
Abstract · 15 pages, 10 figures, 2 tables. Preprint

Phase unwrapping recovers a continuous phase map from measurements known only modulo 2π, in the presence of noise and discontinuities. We propose a tile-based method that combines local spectral reconstruction, reliability-ordered tile joining, and residual-weighted multipath averaging. Each tile is reconstructed by a discrete cosine transform (DCT) least-squares solve, and robust measurements along tile borders guide their joining along a spanning tree. We repeat this reconstruction on shifted tile grids and on rotated and reflected copies of the image, which changes tile borders and joining paths. A residual-weighted average combines the resulting reconstructions, which are computed in parallel and averaged on the fly without being stored. We also introduce the corrected circular rewrapping error, a congruence measure: after removing a global phase offset, it measures how far the rewrapped reconstruction is from the observed phase. It applies to least-squares and path-based methods, even without an unwrapped reference. Used with reference-based errors, it separates agreement with the measurement from recovery of the correct number of cycles. Experiments on radar-interferometric, magnetic-resonance, holographic, and constructed phase images compare our method with seven reference algorithms. Among the methods that complete every test image, ours has the lowest mean fraction of pixels with an error above π. On the images all methods complete, it lies on several speed-accuracy Pareto fronts. Error maps also reveal isolated cycle errors that average scores or congruence alone can hide.

0.58

Conditioning noise is a free regularizer for LoRA fine-tuning: no pathology encoder required for diffusion-based artifact detection in histopathology

eess.IV cs.CV ·2026-09-11 ·Konstantinos Moutselos, Ilias Maglogiannis
code/data
Abstract · 23 pages, 3 figures. Code and laboratory record: https://github.com/kmouts/condnoise-histoqc (doi:10.5281/zenodo.22702198). Data: doi:10.528…

Diffusion-based artifact detectors score whole-slide image patches by reconstruction error under a model fine-tuned on clean tissue. We show that conditioning this fine-tuning on random Gaussian embeddings -- resampled at every step from approx. 200 KB of precomputed embedding statistics, with no encoder, no cache, and no change to inference -- consistently widens the clean/artifact separation. A four-step ablation chain shows the benefit requires neither content (shuffled real embeddings), provenance (synthetic Gaussians), a tuned intensity (flat across an 8x variance range), nor per-patch identity (fresh per-step noise); a LoRA-dropout control shows the conditioning pathway specifically, not generic weight perturbation, carries the effect. Patch-level gains of +0.25-0.48 Cohen's d replicate across nine trainings; honest leave-one-slide-out evaluation clears a pre-registered bar in 2/2 seeds; and two pre-registered external endpoints on a 281-case set confirm pooled Delta F1 = +0.0073 (95% CI) and +0.0129 (97.5% CI, two-look corrected). We release the full evaluation protocol, including measured seed noise and selection-optimism pricing.

0.50

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

eess.IV cs.CV ·2026-09-11 ·Benjamin Jin, Maria del C. Valdés Hernández, Richard Bortsov, Joanna M. Wardlaw, Daniel Bos +1 more
publishedcode/data
Abstract · Accepted at the Stroke and neurovascular diseases Workshop on Imaging and Treatment CHallenges @ MICCAI 2026

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

0.45

Recurrent Dynamic Range Extension

eess.IV cs.CVcs.GR ·2026-09-11 ·Sebastian Dille, Keru Fu, S. Mahdi H. Miangoleh, Yağız Aksoy
top venue
Abstract · 10 pages, 8 figures. Accepted to ACM SIGGRAPH Asia 2026

We present an approach to progressively extend the highlights of an image. Instead of reconstructing the full dynamic range of a complex scene directly, we learn a simpler task first: We extend the dynamic range of an input image by a single exposure value. Once this is mastered, we retrieve the full HDR image for the scene by executing our network recurrently, progressively increasing the dynamic range of the input. Our formulation is agnostic to the input dynamic range and targets a bounded output domain. This enables us to use widely available RAW images for the reconstruction task and adapt adversarial losses to construct realistic images. By incorporating Memory Replay for backpropagation, we can train our network recurrently over multiple inference stages and reduce reconstruction errors. As a consequence, our system reconstructs challenging long-tailed HDR scenes robustly and shows powerful recovery of bright light sources and highlights.

0.40

PiMiX 2.02: Toward AI-Driven Data Fusion in Radiographic Imaging and Tomography

eess.IV physics.data-an ·2026-09-11 ·Zhehui Wang, Shanny Lin, Nicholas Amano, Ramya Gurunathan, Katie Liu +5 more
Abstract · 12 pages, 5 figures

PiMiX (Physics-informed Meta-instrument for eXperiments) was introduced for multi-instrument, multi-experiment, and simulation-experiment data fusion in radiographic imaging and tomography (RadIT). Here we present PiMiX 2.02 as an evolving AI-enhanced cyber-physical meta-instrument integrating imaging sensors, near-sensor computing, data fusion, physics-informed inference, and human-supervised AI workflows across X-ray, neutron, and other modalities. Demonstrated capabilities include multimodal CMOS radiation imaging, simulation-assisted sub-pixel neutron localization, and edge-deployed optical-neural-network (ONN) inference; GPU and ONN implementations achieved greater than 96% precision for neutron-event detection with sub-micron localization. A further advance is human-in-the-loop agentic-AI co-analysis of X-ray and neutron images from inertial-confinement-fusion experiments. Beyond conventional preprocessing, the workflow generates competing feature hypotheses, ranks contours using physics-informed evidence, estimates confidence, and presents alternatives for human review. The same architecture adapts to different physics: X-ray analysis emphasizes dark, nonuniform ring structures using deformable closed paths and multi-scale evidence, whereas neutron analysis targets bright emission envelopes using fractional-emission levels, intensity gradients, and cross-filter persistence. We also highlight automated comparison of an as-designed stereolithography model with an X-ray CT reconstruction of an additively manufactured metal lattice. Together, these examples show progression from AI assistance in specific processing tasks to multi-task, multi-domain scientific co-analysis. PiMiX 2.0 further provides a pathway toward PRISM, a RadIT scientific foundation model, and tighter integration of diagnostics, digital representations, inference, and experimental control.

0.37

Versatile Sleeve-and-Bulk Fabrication of Inversely Designed Nanophotonic Structures with High Pattern Transfer Fidelity

eess.IV physics.optics ·2026-09-11 ·Lan Hoang Mai, Radheya Sham Sarode, William G. Eshbaugh, Sulaiman Al Ghadani, Tyler Manfre +4 more
Abstract

Inverse design is a powerful computational tool for generating nanophotonic devices that should outperform their traditionally designed counterparts. However, translating these theoretical gains into physical devices is challenging because the irregular and non-intuitive features that make inversely designed structures so effective also make them exceptionally difficult to fabricate, typically necessitating substantial process optimization unique to each device design. We describe a versatile two-step nanofabrication process that achieves pattern transfer fidelity in excess of 90% for each of three distinct inverse device designs with no device-specific process optimization.

0.29

A deep dictionary network-based foundation model for ultra-low-dose CT denoising

eess.IV cs.CVcs.LG ·2026-09-11 ·Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu +1 more
Abstract

Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality. Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios. Foundation models present a promising all-in-one paradigm for unified multi-organ denoising. However, their architectures suffer from poor interpretability and rely on heuristic training strategies. To address these limitations, we propose an architecture?interpretable foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising. Inspired by multilayer sparse representation theory, DDN cascades convolutional sparse coding layers with iterative soft-thresholding, providing inherent architectural interpretability. Furthermore, a dynamic dictionary module and a threshold generation module are embedded within each layer to enhance representation ability. We conduct DDN pre-training on more than one million multi-organ normal-dose CT images by recovering clean images from Gaussian-noised inputs. Sparse regularization is additionally imposed on latent feature representations, guiding the network to learn compact and noise-robust priors. The complete architecture is jointly fine-tuned on multi-organ ULDCT datasets, enabling a single unified model to perform denoising across diverse anatomical regions. Extensive experiments validate that our proposed method achieves state-of-the?art performance and consistently surpasses competing ULDCT methods across all mul

0.28

Aligned Radiometric RGB-Thermal Fusion for UAV Facade Anomaly Screening

cs.CV eess.IV ·2026-09-11 ·Yuan Yang, Shulei Li, Haobo Liang
dataset
Abstract · 9 pages, 3 figures. Preprint. Submitted to IEEE Sensors Journal

Unmanned aerial vehicle facade inspection can combine red, green, and blue (RGB) imagery with thermal measurements to screen surface and subsurface anomalies. However, geometric discrepancies between the sensors and thermal image rendering can obscure spatial correspondence and weak temperature contrasts. This article presents a sensor-level pipeline comprising per-sensor correction, RGB-to-thermal registration, common-support cropping, and signed local contrast encoding of 16-bit radiometric measurements. The encoding preserves the distinction between locally hotter and colder regions and supplies the fourth input channel of a compact single-stream detector. We introduce M3T, a dataset of 674 paired RGB and radiometric thermal samples from five facade-inspection projects covering eight component and anomaly categories. The median residual registration error is 3.384 pixels, and a controlled-displacement analysis characterizes how the local contrast response changes under controlled displacement. Project-grouped four-fold evaluation yields mean average precision of 0.168 over intersection-over-union thresholds from 0.5 to 0.95, using 28.50 billion floating-point operations per image. A separate single-split ablation shows improved delamination detection over RGB-only and alternative thermal inputs, although aggregate accuracy does not improve over RGB alone. Evaluation on RGBT-Tiny shows mixed performance with rendered thermal imagery. These results characterize the category-specific benefits and limitations of aligned radiometric contrast for compact facade screening.

0.22

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

eess.IV ·2026-09-11 ·Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann
Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

0.13