CS Paper Radar

Daily listing

2026-09-30 · eess.IV

13 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 13

Nonparametric Distribution Matching for Self-Supervised Whole-Slide Image Condensation

eess.IV cs.LG ·2026-09-30 ·Duong M. Nguyen, Trong Nghia Hoang, Hang Thi Nguyen, Thanh Trung Huynh, Phi Le Nguyen +1 more
top venuecode/data
Abstract · Accepted at NeurIPS 2026, SPIGM@ICML 2026

Histological whole-slide images (WSIs) are central to computational pathology but pose severe computational challenges due to their extremely high resolution, often spanning several gigabytes per slide. To enable scalable learning, existing methods apply self-supervised data condensation to reduce computational cost, but typically rely on heuristic prototype learning and do not explicitly preserve learning-relevant feature distributions for downstream tasks. In response, we introduce a principled reformulation of WSI condensation as a distribution-matching problem under a fixed representational lens, and develop NICER, a tractable approximation framework based on a nonparametric prior with slide-adaptive capacity. Experiments on five histopathology datasets, together with clinical evaluation from a board-certified pathologist, show that NICER consistently outperforms prior methods, achieving an average accuracy improvement of 7.44% while offering improved efficiency-accuracy trade-offs, highlighting the benefits of principled, distribution-aware condensation for scalable histological representation learning. Source codes are available in https://github.com/nmduonggg/NICER.

0.69

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.57

MAV-C: A Framework for the Joint Objective Estimation of Audio-Visual Complexity in Immersive Virtual Environments

eess.AS cs.SDeess.IVeess.SP ·2026-09-30 ·Luca Resti, Amelia Gully, Michael McLoughlin, Gavin Kearney, Alena Denisova
published
Abstract · Published in AES AVARIG 2026: 6th International Conference on Audio for Virtual and Augmented Reality and Immersive Games. Available at: htt…

We present the Motion-Aware Audio-Visual Complexity Metric (MAV-C), a reference-free framework for the joint objective estimation of audio-visual complexity. The metric combines entropy-based audio features (temporal, spectral, and spatial) with visual features (Sobel gradient magnitude, chromatic uniqueness, and optical flow) via a parametric fusion stage, producing a continuous joint complexity score CAV (t) [0,1]. We validate MAV-C on two datasets: a controlled synthetic corpus (SYN) of stimuli with known signal characteristics and a naturalistic gameplay corpus (GAM) of 60 clips drawn from the SAFEPLAY-X dataset. On SYN, the metric exhibits strong validity: the audio score CA and visual score CV are each insensitive to changes in the opposite modality (CoV < 0.003), the joint score CAV spans [0.00,0.90] across all parameter combinations, and single-axis feature sweeps produce monotone trajectories (Spearman up to 0.995). On GAM, CV differs significantly across content categories (Kruskal-Wallis p = 0.021) while CA does not, and the two sub-scores are uncorrelated (r = 0.03), confirming they operate on independent signal dimensions. OFAT sensitivity analysis identifies a two-tier parameter hierarchy, with modality balance (wa) and visual regularization (v) as most significant tunable parameters. Full subjective calibration is planned as future work.

0.50

Spatially Gated Diffusion for Localized Counterfactual Chest Radiograph Editing

eess.IV cs.CV ·2026-09-30 ·Kamran Ullah Afaq, Basit Raza
Abstract · 16 pages, 1 figure, 10 tables

Editing a chest radiograph requires completing the requested change while preserving unrelated content. We study a latent diffusion editor with an instruction-independent source trajectory and an instruction-conditioned editing trajectory. A learned gate mixes their post-sampler candidates at each executed step, and a separate image-space mask composites the decoded proposal with the source. On 2,400 MIMIC-derived requests, 2,244 outputs met the joint target, preservation, quality, and coverage rubric (93.5%), and target completion was 97.4%. Joint validity exceeded a matched composition-only control by 1.7 percentage points (paired patient-cluster 95% interval, 0.6--2.8). At a fixed learned mask, the learned-gate proposal improved joint validity by 1.6 points (0.8--2.4); at a fixed learned proposal, the learned mask improved it by 2.6 points (1.7--3.5). Across three training seeds, mean joint validity was 93.5% with a 0.3-point sample standard deviation. A blinded 240-request assessment yielded adjudicated joint validity of 93.3% for the full editor and 91.7% for composition only. Protected-region mean absolute error decreased from 0.0190 in the raw proposal to 0.0075 after composition. These findings distinguish recurrent-gating effects on the proposal from preservation through final composition in the assessed cohort.

0.42

3D Reconstruction from Arthroscopic Images using NeRF: a preliminary in-silico study

eess.IV ·2026-09-30 ·Hermine Kitio Tsamo, Agathe Yvinou, Daniel Pizarro, Samad Barri Khojasteh, Alexandre Tronchot +4 more
published
Abstract

In knee arthroscopy surgery, accurate registration between preoperative and intraoperative anatomy is a critical step for patient-specific navigation. Achieving an accurate registration requires a reliable 3D reconstruction of the joint during surgery. Preoperative 3D models can be obtained from patient imaging through segmentation and reconstruction, but generating an intraoperative 3D representation remains particularly challenging. Arthroscopic imaging suffers from a limited field of view, low surface texture, and strong specular reflections, which make conventional feature-based 3D reconstruction methods unreliable. In this work, we investigate the application of MIS-NeRF (Minimally-Invasive Surgery Neural Radiance Fields) for reconstructing intraoperative knee 3D models from monocular arthroscopic images. The approach is evaluated on six simulated arthroscopic acquisitions representing six patient-specific knee 3D models. Both qualitative and quantitative results are presented to assess the reconstruction quality. The reconstructed knee 3D models were evaluated through their rendered images, achieving PSNR (Peak Signal-to-Noise Ratio) of 31.88 $\pm$ 2.82, SSIM (Structural Similarity Index) of 0.98 $\pm$ 0.004 and LPIPS (Learned Perceptual Image Patch Similarity) of 0.017 $\pm$ 0.006. These preliminary results suggest the feasibility of NeRF-based reconstruction in the challenging context of arthroscopy and may represent a promising step toward accurate in-silico preoperative-to-intraoperative 3D registration for computer-assisted orthopedic surgery. Further, validation on real arthroscopic data will be necessary to assess clinical applicability.

0.37

ExpandDiff: Dynamic Range Expanding Diffusion for Single-Image HDR Reconstruction

cs.CV eess.IV ·2026-09-30 ·Mehmet Emre Andıran, Zhuoqian Yang, Liying Lu, Mathieu Salzmann, Sabine Süsstrunk
benchmarkcode/data
Abstract · 5 pages, 3 figures, 2 tables. Submitted to ICASSP 2027. Code and supplementary material: https://memreandiran.github.io/expanddiff/

Single-image HDR reconstruction requires inferring missing detail while preserving the visible content of an LDR image. Differences in sensor dynamic range and exposure cause LDR images to lose varying amounts of information in shadows and highlights. We present ExpandDiff, a conditional diffusion pipeline that jointly reconstructs clipped shadows and highlights. To account for this variation, we introduce Dynamic Clipping Synthesis (DCS), which randomly samples shadow and highlight clipping percentiles when constructing training inputs from HDR targets. A pixel-space diffusion model guided by spatially-adaptive normalization then predicts perceptually encoded HDR through a bounded output head, reconstructing both clipping directions in one sampling trajectory. On the SI-HDR benchmark, ExpandDiff variants improve HDR reconstruction accuracy by 3.43 dB in PU21-PSNR over the strongest evaluated competing method, and by 7.34 dB under two-sided clipping. The code and supplementary material are available at https://memreandiran.github.io/expanddiff/.

0.32

The Effect of Tissue Detection on False Positives of Diffusion-Based Artifact Detection in Histopathology

eess.IV cs.CV ·2026-09-30 ·Konstantinos Moutselos, Ilias Maglogiannis
Abstract · 29 pages, 3 figures, 4 tables, including supplementary material. Code, data and models: https://doi.org/10.5281/zenodo.23016733

One-class artifact detectors for whole-slide images learn normal tissue from a clean training pool and flag departures from it. The pool is built by a preprocessing pipeline whose tissue-detection step is usually treated as neutral. We tested whether it is. On 16 annotated slides from The Cancer Genome Atlas, we rebuilt the clean pool of a diffusion-based detector with different tissue detection methods and compared the resulting models in a four-fold cross-validation. Per-slide saturation-Otsu detection excluded normal tissue, chiefly tissue with large clear spaces such as adipose tissue and alveolar parenchyma, and on slides with thick marker ink kept the ink while excluding ordinary tissue. Replacing it with entropy-based detection reduced the false-positive fraction on held-out clean slides from 0.102 to 0.016, in every fold and with a second training seed, without loss of sensitivity; the gain came from the composition of the pool, not its size. Across three tissue detection methods, false positives followed the fraction of such clear-space tissue in the pool, a statistic that needs no labels or training (0.103, 0.016 and 0.009). The effect did not carry over at the same size to a nearest-neighbour detector on foundation-model features. On an external cohort, the curated pool lowered clean-control false positives by about 20%, far less than on the development slides, and the remaining cross-center loss was not explained by stain differences. For one-class quality control, tissue detection decides what the model learns as normal and should be chosen and reported accordingly.

0.31

CPathOGen: Spatially and Morphologically Controlled H&E Counterfactuals for Probing Pathology Models

eess.IV q-bio.QM ·2026-09-30 ·Samarth Singhal, Varang Rai
code/data
Abstract

Computational pathology models infer biologically and clinically meaningful outcomes from histology, but their predictions are shaped by complex, intertwined tissue signals whose roles are important to understand. Common pixel- and feature-space perturbations can produce implausible tissue, making model responses difficult to interpret. We introduce CPathOGen, a conditional latent-diffusion framework for generating paired H\&E counterfactuals with explicit controls over cellular spatial organization, nuclear morphology, and stain appearance. Cellular maps condition spatial structure through a spatial encoder, while a morphology/appearance vector modulates denoising through blockwise feature-wise linear modulation (FiLM). On held-out H\&E tiles, CPathOGen generates visually plausible tissue with improved distributional agreement after spatially guided selection, as reflected by lower Fréchet Inception Distance (FID) and Kernel Inception Distance (KID); generated cells track requested abundance and position, and measured morphology and color vary monotonically with their controls. We use these verified interventions to probe pathology encoders with endpoint heads, task-specific classifiers, and survival models. Responses are quantified using total variation distance and prediction-flip rate. We further introduce the Biology-Nuisance Sensitivity Ratio, a metric that contrasts model sensitivity to biologically motivated morphology and spatial factors with sensitivity to non-biological, stain-related nuisance variation. CPathOGen provides a practical, fidelity-audited framework for evaluating robustness and controlled feature sensitivity in computational pathology model. \href{https://github.com/a12dongithub/PathOGen}{GitHub} and \href{https://huggingface.co/a12donhf/CPathOGen}{Hugging~Face}.

0.29

ReGain: Restoring Subject Fidelity in Personalization on Synthetic Images

cs.CV cs.AIcs.LGeess.IV ·2026-09-30 ·Shubhang Bhatnagar, Ishan Bhatnagar, Viraj Shah, Narendra Ahuja
Abstract

Text-to-image diffusion models are personalized to a subject by DreamBooth fine-tuning on a handful of its images. Increasingly, these images come from a diffusion model rather than a camera. We show that fine-tuning on such synthetic images degrades subject fidelity, producing oversaturated color and excess high-frequency detail. To isolate the cause, we fine-tune two models from the same base model with the same DreamBooth recipe, one on real photos of a subject and one on synthetic images of that subject generated by the first. We trace the degradation to classifier-free guidance (CFG). For the model personalized on synthetic images, the angle between the conditional and unconditional noise predictions, and with it the norm of their difference, is much larger than for the model personalized on real photos. This inflation grows toward high frequencies and also appears at other prompts semantically close to the subject, such as its class noun, but not at unrelated ones. We propose ReGain, a training-free correction applied at sampling time that measures how much each frequency band of the guidance is inflated relative to the base model and scales that band down accordingly. ReGain needs no real photos. On Stable Diffusion v1.5, ReGain closes 51-64% of the subject-fidelity gap to the model personalized on real photos, as measured by DINO, DINOv2 and CLIP-I. It also improves subject fidelity on SDXL and SD 3.5 and preserves text alignment on all three backbones.

0.27

Synthetic-to-Real Transfer in Cerebral Microbleed Generation and Segmentation

eess.IV ·2026-09-30 ·To-Liang Hsu, Ting-Yu Lai, Ching-Ting Lin, Chun-Hao Huang, Wei-Chun Wang
Abstract

The development of automated cerebral microbleed (CMB) detection models is hindered by the low prevalence of CMBs and the high cost of expert annotation. To address this limitation, we developed a synthetic CMB generation pipeline and investigated the effectiveness of synthetic lesions for training deep learning detectors. Models trained solely on synthetic data achieved substantial detection performance, reaching approximately 87% of the lesion sensitivity of their real-trained counterparts. We further investigated the complementary roles of synthetic and real data under different training paradigms, revealing that a significant performance gap remains. Moreover, we found that successful synthetic-to-real transfer is strongly dependent on the downstream detection architecture, providing new insight into both the potential and limitations of synthetic data for CMB detection.

0.19

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Hetero-modal learning and corruption-resistant hetero-modal inference for joint segmentation of white matter hyperintensities and ischaemic stroke lesions in MRI

eess.IV ·2026-09-30 ·Jesse Phitidis, William N. Whiteley, Joanna M. Wardlaw, Miguel O. Bernabeu, Francesco Dalla Serra +1 more
Abstract

White matter hyperintensities (WMH) and ischaemic stroke lesions (ISL) are visually confounding, co-occurring pathologies that require large, diverse datasets for robust deep learning segmentation. However, assembling such datasets is hindered by cohort samples that lack reference segmentations from both features and complete sets of MRI structural sequences (i.e., "modalities"). To maximise data utility, we investigate hetero-modal learning using a dataset of 206 vascular disease patients across four MRI sequences (T1-weighted, T2-weighted, fluid-attenuated inversion recovery, and diffusion-weighted imaging) with expert annotations of both WMH and ISL. We demonstrate that hetero-modal learning outperforms models trained using a single imaging modality in scenarios with substantial missing data, including a split where only 10% of the training data contains all four modalities while the remainder is uni-modal, and a split relying on a single shared "anchor" modality with zero overlap between the remaining modalities. Furthermore, models trained under this second split successfully perform inference on unseen combinations of modalities. Yet, while standard hetero-modal networks handle missing sequences, clinical deployment introduces the additional challenge of silent data degradation - where modalities are present but severely corrupted. To bridge this gap, we introduce the Multimodal Attention Router (MMAR) block. Our experiments demonstrate that, when trained with a "corruption augmentation" strategy, the MMAR effectively dynamically weights the encoded features of each modality, maintaining strong performance during hetero-modal inference even in the presence of unflagged catastrophically corrupted modalities.

0.13

Optimization of Deep Learning Model for Denoising Dose Profiles in Proton Therapy

eess.IV q-bio.QM ·2026-09-30 ·Junaid Jawaid, Matteo Spezialetti, Gabriele Libardi, Giovanni Stilo, Filippo Mignosi
Abstract

Proton therapy offers a dosimetric advantage over conventional radiotherapy through the Bragg peak, enabling precise dose delivery to the tumour while sparing surrounding tissue. Monte Carlo (MC) simulation provides the most accurate dose calculation but is computationally expensive for clinical workflows. A promising compromise is to simulate with a reduced number of primary histories and recover a high-quality dose distribution through a deep learning denoising step. In this work, we take a 3D multiscale U-Net from recent literature as a case study and investigate two improvements critical for clinical deployment. First, we replace the standard MSE training objective with a differentiable $γ$-index-based loss, extended to native 3D operation, and demonstrate that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate of 99.47\% at 2mm/2\% and 95.67\% at 1mm/1\% on the test set, compared to 92.10\% and 71.13\% for MSE. Second, we apply L1-norm structured filter pruning to reduce the model's memory footprint, achieving a 13.3\% parameter reduction with negligible performance loss under partial pruning, and 20\% reduction under full-block pruning after fine-tuning.

0.09