CS Paper Radar

Daily listing

2026-10-16 · eess.IV

14 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 14

LUMINR: Intensity-conditioned Meta-learned INRs for Accelerated Medical Image Registration

eess.IV cs.CV ·2026-10-16 ·Damian Rynczak, Marek Wodzinski
hot direction
Abstract · 13 pages, 7 figures, 3 tables

Implicit neural representations (INRs) have been applied to deformable image registration, where a lightweight network maps a spatial coordinate to a deformation vector. Because an INR encodes one specific signal in its parameters, a fresh network must be optimized for every image pair at test time, which is slow. Existing methods reduce this cost by meta-learning an initialization across a population of image pairs, and condition the weights of the INR globally, so the same conditioning applies at every coordinate while the deformation field it initializes varies across the domain. We propose LUMINR, a meta-learning framework that accelerates this per-pair fitting and in which the conditioning is local instead. LUMINR uses an INR that maps a coordinate, together with local intensity and gradient features, to a deformation vector, so the conditioning varies over the domain at the resolution of the field being modelled. Its objective is to find an initialization of the INR parameters from which the network can be fine-tuned to register any unseen pair in only a few optimization iterations. We evaluate LUMINR on 3D deformable registration of brain MRI from the OASIS dataset, where local conditioning and the meta-learned initialization prove complementary: early in fitting they reach a markedly higher accuracy than either does alone. Fine-tuned from that initialization, LUMINR matches the accuracy of the same conditioned INR fit from scratch in roughly a tenth of the gradient steps and a tenth of the wall-clock time, while the deformation fields stay smooth with negligible folding.

0.50

Measurement-Adaptive Light-Cone Transform for Robust Non-Line-of-Sight Imaging

eess.IV cs.CV ·2026-10-16 ·Lianfang Wang, Xueying Liu, Junnan Dong, Qinghua Zhang, Jun Liu +2 more
published
Abstract

Practical non-line-of-sight (NLOS) measurements are affected by noise and deviations from idealized light transport, which can degrade reconstruction with conventional light-cone transform (LCT) methods. We propose the Measurement-Adaptive Light-Cone Transform (MALCT), a physics-guided framework that retains the efficient Fourier-domain inversion structure of LCT. {Within a unified variational formulation, MALCT combines the analytical response with a shared learned response through measurement-conditioned weighting and predicts a measurement-conditioned, frequency-dependent regularization map.} An attention-enhanced spatio-temporal feature extraction module captures long-range temporal dependencies and local spatial correlations to support reconstruction under low-signal conditions. Experiments on synthetic data and real measurements from different NLOS systems demonstrate improved reconstruction quality. Controlled evaluations further assess robustness to temporal-response broadening and reduced acquisition time. MALCT also preserves scene structures with spatial sampling grids down to $32\times32$, supporting its potential for NLOS imaging under limited acquisition budgets.

0.35

Image Moment Estimation for Crowded Datasets

eess.IV q-bio.QM ·2026-10-16 ·Andy Zhang, Oscar Mickelin, Amit Singer
Abstract · 29 pages, 11 figures

Single-particle cryogenic electron microscopy (cryo-EM) is an imaging technique capable of reconstructing high-resolution three-dimensional (3D) structure of biological macromolecules from a set of noisy projection images taken at random viewing directions. The mathematical model for cryo-EM images typically assumes that each image contains exactly one particle, which is centered at the origin. However, many experimental datasets contain particle images which include multiple particles: one central particle and a few crowding particles. This deviation from the model leads to inaccurate estimation of image statistics, such as the low-order image moments. To account for this, we propose a method to estimate image moments while correcting for the effect of crowding particles. This method can be run directly from a set of cryo-EM micrographs with picked particles, and we demonstrate its efficacy on a wide array of synthetic data.

0.35

Implicit Neural Models for Direct Multi-Shell Diffusion MRI Signal Estimation

eess.IV cs.CV ·2026-10-16 ·Sanna Persson, Fabian Leander Sinzinger, Christoffer Olsson, Rodrigo Moreno
Abstract · 23 pages (9 pages main text + supplementary material), 9 figures, 18 tables

Diffusion magnetic resonance imaging is a noninvasive technique that is sensitive to the motion of water molecules in human tissue. The image signal is commonly described in q-space; however, a complete coverage of this space is often infeasible due to hardware and acquisition time limitations. In this work, we propose to represent the entire diffusion signal using an implicit neural representation network with wavelet activation functions. The signal space is encoded using Fourier features and spherical harmonics basis functions for a continuous output distribution of the raw diffusion data, enabling both super-resolution and q-space interpolation. Additionally, we introduce a pretraining strategy using a group template, enabling faster per-subject optimisation when combined with nonlinear registrations of subjects into template space. We tested the method with 10 subjects from the Human Connectome Project and 26 subjects from in-house data (multidimensional diffusion MRI from a Parkinson's disease cohort). The results show that the proposed method yields high-fidelity reconstructions with significantly reduced memory requirements compared to raw diffusion-weighted images. The pretraining scheme showed good generalisability properties on data acquired with very different protocols. We further assess the method on downstream metrics relevant to diffusion MRI data from the learned representations.

0.31

FlashReFocus: Interactive Image Refocusing in Seconds

cs.CV cs.AIeess.IV ·2026-10-16 ·Ching-Heng Cheng, Chia-Ming Lee, Ming-Ching Chang, Xin Li, Yu-Lun Liu +1 more
benchmarkcode/data
Abstract · 38 pages (8 main + appendix), 47 figures, 16 tables. Project page: https://ming053l.github.io/FlashReFocus/ Code: https://github.com/ming053…

Single-image refocusing changes the focal plane and depth of field of a photograph after capture. It is inherently interactive: users try many focal points and blur strengths on one image, so each edit should be fast and change only the blur. Recent generative methods, however, rerun large diffusion models for every edit. We observe that the two sub-problems differ in kind: recovering the all-in-focus image is ill-posed and needs a generative prior, whereas rendering blur is largely determined by depth and the focal plane. We therefore propose FlashReFocus, which runs diffusion once per photograph and renders every edit with a lightweight network. To address the ill-posed restoration, a one-step diffusion deblurrer with a decoder refiner recovers fine detail efficiently while balancing fidelity and perceptual quality. For precise control, the renderer is conditioned on an explicit defocus map and uses defocus-bias attention, which lets pixels at similar defocus share information without interference from pixels at other depths; in-focus content stays unchanged, and editing the map yields tilt-shift and two focal planes. To further test generalization to unseen cameras, we collect 3CReal, a three-camera benchmark of 89 pairs. FlashReFocus achieves the best perceptual fidelity for zero-shot bokeh rendering on EBB! and 3CReal, refocuses 148.3x faster than GenRefocus, and takes about half a second per further edit, 462x faster.

0.29

Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide Imaging

eess.IV cs.CV ·2026-10-16 ·Julia Merta, Daniel Mendelsohn, Benedikt Schoser, Joanna Polanska, Michal Marczyk
benchmarkcode/data
Abstract

Technical artifacts introduced during tissue preparation or slide scanning remain a major obstacle to developing robust computational pathology algorithms for hematoxylin and eosin (HE)-stained whole-slide images (WSIs). Despite the growing number of quality-control tools, their real-world utility remains hard to assess because of the limited number of publicly available implementations and the lack of systematic, multi-dataset comparisons. This paper presents a benchmark of artifact segmentation methods for HE-stained WSIs. After a literature review, six publicly available algorithms were selected and compared in terms of their ability to segment artifact-free tissue and selected artifact classes. Two publicly available datasets and a newly introduced dataset released to support further research were used for evaluation. Tissue samples from multiple medical centers and different organs are included, enabling evaluation across heterogeneous data sources. Segmentation performance was assessed using Dice Index, pixel-level recall, and false discovery rate for artifact-free tissue segmentation. For algorithms supporting multiclass artifact segmentation, class-wise Dice Index and inter-class misclassification were evaluated. In addition to segmentation quality, processing time was assessed. Statistical analysis revealed significant differences in segmentation performance between methods. HistoKit, which incorporates a modified version of the GrandQC, was identified as the best-performing algorithm, while HistoQC was the worst. In terms of artifact types, dark spots and out of focus regions were harder to segment than others. Finally, a simple post-processing step was introduced for HistoKit, which further improved segmentation performance. The benchmark establishes a reference for evaluating and developing artifact segmentation methods for HE-stained WSIs.

0.29

DinoMUSE: A DINOv2-guided Framework for Unsupervised Lateral Motion Estimation in Ultrasound Elastography

eess.IV cs.CV ·2026-10-16 ·Xiyao Meng, Xingyue Wei, Baihua Luo, Bo Peng, Jianwen Luo
code/data
Abstract

Quasi-static ultrasound elastography (USE) is a non-invasive imaging method for assessing soft tissue mechanical properties. Limited by low resolution, low sampling frequency and lack of phase information in the lateral direction, accurate lateral motion estimation remains a critical bottleneck in USE. Existing methods mainly rely on local image matching and physical constraints (such as tissue incompressibility assumption and effective Poisson's ratio), which lack sufficient contextual information. We present DinoMUSE, a DINO-guided mixture-of-experts (MoE) framework for unsupervised lateral motion estimation in USE. DinoMUSE incorporates high-level visual representations learned by DINOv2 into the motion estimation network to provide global contextual guidance. To facilitate effective interaction between DINOv2 features and local matching features, an MoE-based feature-fusion module adaptively transforms and integrates the two representations. Evaluations against NCC, GLUE, RAFT, and sPICTURE on simulation and in-vivo breast datasets show that DinoMUSE substantially improves lateral estimation accuracy while maintaining competitive axial performance. Specifically, DinoMUSE reduces the mean square error (MSE) of lateral displacement and strain estimation by 60% and 65%, respectively, compared with a SOTA algorithm on the simulation dataset. For in-vivo breast data, DinoMUSE achieves axial strain SNR and CNR of 5.70 and 4.82, and lateral strain SNR and CNR of 4.61 and 2.23, compared to 4.11 and 3.32, and 4.57 and 2.13 for the best competing method, alongside improved lesion visualization. These findings indicate the potential of leveraging transferable visual representations and adaptive feature fusion to improve lateral motion estimation in USE. The code is available at xxxxxxxx.

0.27

Spatiotemporal Adaptive Eigenspectrum Remapping in Transcranial Ultrasound Localization Microscopy

eess.IV eess.SPphysics.med-ph ·2026-10-16 ·Stephen A Lee, Isidora Jelenkovic, Maia V. Kokoeva, Jean Provost
unusual
Abstract · 11 pages

Clutter suppression is a critical preprocessing step in ultrasound blood flow imaging, yet conventional singular value decomposition (SVD) filtering depends on data-specific eigenvalue cutoffs that can remove slow flow along with tissue clutter. Here, we introduce adaptive eigenspectrum remapping (AER), a general framework in which clutter is suppressed by continuously remapping, rather than truncating, the eigenvalue spectrum of the spatiotemporal covariance, and we investigate zero-phase component analysis (ZCA) matrix whitening as an instance of AER for transcranial ultrasound localization microscopy (ULM). Rather than discarding eigenspaces, ZCA-based AER whitens the eigenvalue spectrum, reducing the dominance of coherent clutter, including skull reverberation, while retaining weak flow signals. We evaluate AER on both temporal and spatial covariance matrices in mouse brain datasets acquired with long temporal ensembles. Compared with SVD filtering, ZCA improves microbubble contrast and vascular image quality, increases trajectory density across low- and high-concentration regimes, and reveals more low-velocity trajectories in ULM velocity maps. Spatial AER further maintains reconstruction quality across extended ensembles and enables fuller single capillary reporter (SCaRe) reconstructions, including connected artery-to-capillary-to-vein tracks. These results support AER, here instantiated as ZCA whitening, as a data-adaptive alternative to manually thresholded SVD filtering for high-resolution microvascular imaging.

0.26

ProtoGTX: Prototype-Aligned Graph Transformer for Explainable Whole-Slide Image Analysis

eess.IV cs.CVq-bio.QM ·2026-10-16 ·Iori Azuma, Hiroyuki Kusuhara, Tadahaya Mizuno
code/data
Abstract · 14 pages, 3 figures, 2 tables. Code: https://github.com/mizuno-group/ProtoGTX

Deep learning has achieved strong performance in computational pathology, but explaining whole-slide image (WSI) predictions remains challenging. Existing explanation methods often highlight important regions without identifying their morphological patterns, leaving a gap between patch-level computational evidence and slide-level pathological interpretation. We propose ProtoGTX, a graph-based framework that combines spatial contextualization with a flexible morphological prototype vocabulary. ProtoGTX separates the reference prototypes used to define morphological concepts from the predictive model: the reference vocabulary can be generated from training data by unsupervised clustering or supplied externally, and remains fixed during classifier training. Patch features are first contextualized over a spatial graph, after which learnable prototypes representing morphological concepts are optimized through cross-attention. Their slide-level activation profile is aligned with the morphological composition induced by the fixed reference prototype bank. On the CPTAC and BRACS datasets, ProtoGTX outperforms the evaluated MIL, prototype-based, and graph-based baselines, with particularly pronounced improvements on BRACS. Qualitative analyses further show that spatial contextualization transforms fragmented patch-level prototype assignments into more coherent tissue regions. In BRACS, prototype maps also co-localize with pathologist annotations and regions relevant to slide-level prediction. These results demonstrate that ProtoGTX provides complementary semantic and spatial explanations while retaining a prototype vocabulary that can be defined independently of the predictive model. Code is available at https://github.com/mizuno-group/ProtoGTX.

0.25

Stabilizing Illumination Conditioning in SSM-Based Low-Light Image Enhancement with Bottleneck Prompt Sidecars

eess.IV cs.CV ·2026-10-16 ·Wei Chen Ng, Qiyi Xie, Jian Ding Tan, Yan Kang Lee, Abdulrab Hakim Qaid Abdullah +1 more
Abstract

Low-light image enhancement (LLIE) requires more than brightness amplification because real low-light images often exhibit spatially varying illumination, amplified noise, color distortion, and local detail loss. Recent SSM- and Mamba-based restorers provide efficient long-range modeling, yet the route for introducing illumination priors into such backbones remains insufficiently studied. This study addresses safe illumination conditioning for SSM-based LLIE through a bottleneck-side PromptAdapter. A lightweight illumination estimator first predicts a single-channel illumination map, which is then converted into prompt tokens and injected through a residual sidecar adapter at the bottleneck, thereby avoiding direct modification of the state-space core. Under a locked three-seed evaluation protocol on LOL-v1, LOLv2-Real, and LOLv2-Synthetic, the PromptAdapter improves over the Base model by 0.94 dB, 1.24 dB, and 0.93 dB in PSNR, respectively, while also improving SSIM, LPIPS, and masked dark-region metrics. The clearest real-data evidence appears on LOLv2-Real. A Learned-Fixed control on LOL-v1 indicates that the present results support the utility of the sidecar conditioning pathway more strongly than a strict claim of illumination-conditioned superiority, and the LOLv2-Synthetic result remains stability-conditioned. These findings suggest that, in SSM-based LLIE, conditioning design can be as important as the conditioning signal itself.

0.25

UniPolar: Joint Image and Polarimetric Restoration under Compound Degradations via Physical Consistency Learning

cs.CV eess.IV ·2026-10-16 ·Yang Jin, Guangyu Guo, Linghao Shen, Binglu Wang
benchmark
Abstract · 13 pages, 11 figures

Polarimetric image restoration aims to recover polarization angle images and reliable polarimetric quantities from degraded observations. Beyond visual fidelity, it also requires preserving the physical relationships underlying reliable polarimetric estimation. However, existing methods typically address either device- or environment-induced degradations in isolation, limiting their applicability to color polarization filter array (CPFA) imaging, where both often coexist. Such compound degradations jointly perturb image intensities and cross angle polarization differences. Consequently, improved image fidelity alone does not necessarily ensure accurate Stokes, DoLP, and AoLP recovery. To address this challenge, we propose UniPolar, a coupled Image Stokes framework for joint image polarimetric restoration from compound-degraded CPFA observations. Specifically, UniPolar employs two complementary streams to reconstruct four polarization-angle images and directly predict Stokes difference components. To coordinate these streams, Degradation Conditioned Cross Domain Interaction combines Dual Domain Frequency Interaction for frequency selective evidence exchange with Degradation Conditioned Modulation for condition adaptive feature correction. Furthermore, at the output level, Image Stokes Physical Consistency Learning aligns image derived and directly predicted Stokes components while regularizing angular fidelity and the physical feasibility of DoLP. On the compound-degradation benchmark, UniPolar achieves average image and DoLP PSNR of 31.522 dB and 24.097 dB, respectively, with an average AoLP error of 16.833 degree. These results underscore the importance of jointly considering visual fidelity and polarimetric reliability, offering a physically grounded perspective on learning based restoration under compound degradations.

0.21

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

TransNSNet: A Transformer-Enhanced Multi-Scale Adversarial Framework for CT-to-PET Image Synthesis

eess.IV cs.CV ·2026-10-16 ·Shaojun Li, Xiaoyu Deng, Ikuo Keshi
Abstract · 21 pages, 7 figures. Supplementary material included. Under review at Biomedical Signal Processing and Control

This study investigates CT-to-PET image synthesis using TransNSNet, a Transformer-enhanced multi-scale adversarial framework. A paired CT-PET dataset was curated from the public non-small cell lung cancer (NSCLC) Radiogenomics collection through patient screening, slice-level matching, preprocessing, and patient-level train-test separation. The proposed framework generates PET-like predictions at multiple spatial scales and applies coarse-to-fine reconstruction supervision, while TransPatchGAN introduces contextual feature interaction into adversarial evaluation. A progressive ablation study compares Pix2Pix, NSNet-Base, NSNet-D, and TransNSNet. Image-level performance was summarized over a fixed convergence window (epochs 80-101) from one training run per model. TransNSNet achieved the best mean value in nine of ten metrics, whereas NSNet-Base achieved the highest visual saliency-induced index. For fixed-fraction high-intensity regions, NSNet-D was marginally higher in slice-level recall and balanced accuracy, but the equal-weight patient-level values were nearly identical and the highest Dice values shifted to TransNSNet. These differences were small relative to between-patient variability. In the separate adaptive patient-level analysis (n=10), no pairwise model difference remained statistically significant after Holm correction. TransNSNet also had a substantially smaller parameter footprint than the original next-scale models. These findings indicate promising image-quality trends, but they do not establish statistical superiority or clinical validity; synthesized PET-like images should not be interpreted as substitutes for clinically acquired PET.

0.17

Deep-Learning Algorithm for Indeterminate Thyroid Nodules: Comparison and Combination with Molecular Testing

cs.CV q-bio.QMeess.IV ·2026-10-16 ·Jichen Yang, Jeffrey Ashton, Jikai Zhang, Maciej A. Mazurowski, Benjamin Wildman-Tobriner
Abstract · 16 pages, 7 figures, 8 tables (3 supplementary)

Thyroid nodules with indeterminate cytology (Bethesda III) carry an intermediate risk of malignancy, and molecular testing is widely used to decide between surgery and surveillance, but it is costly and not universally available. We investigated whether a convolutional neural network (CNN) applied to routine ultrasound images can stratify Bethesda III nodules, and how it compares and combines with molecular testing. We retrospectively identified 466 nodule records from 418 patients who underwent molecular testing (Afirma or ThyroSeq). A CNN pre-trained on determinate nodules was adapted to indeterminate nodules with soft labels and transfer learning. After removal of duplicate records, 119 nodules with surgical pathology were used for development and 47 were held out for testing. On the test set, the deep learning (DL) model achieved an AUC of 0.73 (95% CI 0.51-0.94), compared with 0.55 (0.38-0.71) for molecular testing (P = 0.15). At a cut-off inherited from the original algorithm, the DL model was more specific than molecular testing (0.95 vs 0.32; P < 0.001), with a higher positive predictive value (0.67 vs 0.21), a lower sensitivity (0.44 vs 0.78; P = 0.25) and a similar negative predictive value (0.88 vs 0.86). All six DL-positive test nodules were molecular-positive, and the DL output split the molecular-positive nodules into a high-risk (4/6 malignant) and a lower-risk group (3/27 malignant; P = 0.01). Surgical verification was strongly driven by the molecular result (99% of positive vs 19% of negative results), and molecular-test accuracy depended on the platform. A logistic regression of the DL output, nodule size and the molecular result dropped the DL term and did not improve on the DL output alone. Ultrasound DL complemented molecular testing for Bethesda III nodules, in particular by identifying molecular-positive nodules at lower risk of malignancy.

0.14