CS Paper Radar

Spatiotemporal Adaptive Eigenspectrum Remapping in Transcranial Ultrasound Localization Microscopy

Stephen A Lee, Isidora Jelenkovic, Maia V. Kokoeva, Jean Provost

eess.IV eess.SPphysics.med-ph ·submitted 2026-10-16 08:11 UTC · v1
unusual

Abstract

Clutter suppression is a critical preprocessing step in ultrasound blood flow imaging, yet conventional singular value decomposition (SVD) filtering depends on data-specific eigenvalue cutoffs that can remove slow flow along with tissue clutter. Here, we introduce adaptive eigenspectrum remapping (AER), a general framework in which clutter is suppressed by continuously remapping, rather than truncating, the eigenvalue spectrum of the spatiotemporal covariance, and we investigate zero-phase component analysis (ZCA) matrix whitening as an instance of AER for transcranial ultrasound localization microscopy (ULM). Rather than discarding eigenspaces, ZCA-based AER whitens the eigenvalue spectrum, reducing the dominance of coherent clutter, including skull reverberation, while retaining weak flow signals. We evaluate AER on both temporal and spatial covariance matrices in mouse brain datasets acquired with long temporal ensembles. Compared with SVD filtering, ZCA improves microbubble contrast and vascular image quality, increases trajectory density across low- and high-concentration regimes, and reveals more low-velocity trajectories in ULM velocity maps. Spatial AER further maintains reconstruction quality across extended ensembles and enables fuller single capillary reporter (SCaRe) reconstructions, including connected artery-to-capillary-to-vein tracks. These results support AER, here instantiated as ZCA whitening, as a data-adaptive alternative to manually thresholded SVD filtering for high-resolution microvascular imaging.

Comment
11 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Observable And Null Space Electrophysiological Source Imaging with Diffusion Priors

cs.CE ·2026-10-20 ·Zirui Wen, Shihao Yang, Feng Liu
similarity 0.53
Abstract

Electrophysiological source imaging is severely underdetermined because the lead-field matrix has limited rank relative to the source dimension and strongly correlated columns. Scalp EEG measurements constrain only the observable row-space component, leaving a high-dimensional null space unobservable. We propose a two-stage framework coupling posterior diffusion refinement with deterministic null-space completion. A minimum-norm-initialized, singular-coordinate Posterior-DDIM sampler combines a spatiotemporal diffusion prior with direction-dependent measurement reliability to refine the observable component. A frozen ridge predictor and nonlinear temporal residual network then estimate the null component under explicit projection constraints, preserving the refined row estimate and its predicted EEG exactly. All learned components are trained exclusively on simulated cortical activity and its row-null decomposition, without paired EEG-source training data. Across simulations with varying noise levels, the method achieved higher frame-level area under the receiver operating characteristic curve and average precision, together with lower localization error, than conventional and learning-based baselines. Exploratory evaluations on evoked EEG and simultaneous scalp EEG-stereo-EEG recordings showed condition- and event-dependent concordance with cross-modal and intracranial references.

0.11

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

cs.AI ·2026-11-09 ·Juan Liu, Nian Wang
similarity 0.51
Abstract · Submit to a journal; under review

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09$\pm$0.60% versus 21.55$\pm$1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.

0.17

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.51
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.24

Sparse Range-Doppler Profile Recovery in Colored Interference for Adaptive Radar

eess.SP ·2026-11-09 ·Tao Wang, Augusto Aubry, Antonio De Maio, Junli Liang
similarity 0.51
Abstract

Range-Doppler profile (RDP) recovery is a fundamental task in adaptive radar signal processing, whose performance can be severely degraded by Doppler grid mismatch and colored interference. This article develops a unified sparsity-aware framework for on-grid and off-grid RDP recovery in the presence of correlated clutter with unknown spectral properties. The problem is formulated within a regularized maximum likelihood framework by exploiting both primary and secondary data, where the sparse RDP and interference covariance are jointly inferred, while Doppler frequency displacements are additionally estimated in the off-grid case to mitigate basis mismatch. Both covariance-adaptive one-step formulations and their sample-covariance-matrix-based two-step alternatives are developed within the mentioned framework. The resulting challenging nonconvex optimization problems are efficiently tackled by a majorization-minimization (MM) algorithm for the on-grid case and an MM-minimum block improvement (MBI) approach for the off-grid counterpart. Furthermore, Bayesian information criterion (BIC)-based refinement strategies are introduced to improve RDP recovery and Doppler frequency displacement estimation. Numerical results under colored interference demonstrate the superior recovery performance of the proposed methods over representative benchmarks.

0.21

X-LMC: Cross-View Spatiotemporal Collateral Circulation Scoring from DSA

cs.CV ·2026-08-19 ·Maedeh Hafezi Moghadas, Hakim Baazaoui, Lukas Bastian Otto, Susanne Wegener, Björn Menze +1 more
publishedcode/data similarity 0.50
Abstract · 11 pages, 3 figures, 1 table. Accepted at SWITCH+ 2026, a MICCAI 2026 workshop

Digital subtraction angiography (DSA) is the reference standard for leptomeningeal collateral (LMC) assessment, providing critical prognostic insights to guide secondary treatment strategies, neurorehabilitation planning, and retrospective stroke research. However, clinical LMC grading via the ASITN/SIR scale relies on manual, highly variable visual inspection. We introduce X-LMC, a spatiotemporal framework for automated collateral scoring from time-resolved biplane DSA. The proposed architecture encodes spatial frame representations through a DINOv2 backbone, fuses orthogonal projections via a token-level cross-view attention module, and models representations of contrast bolus dynamics using a recurrent network architecture. We evaluate our framework on a multicenter dataset of 134 patients with M1-segment occlusions. In a 5-fold cross-validation setting, X-LMC yields higher point estimates than static architectures and spatiotemporal baselines adapted from related angiographic tasks, achieving a Quadratic Weighted Kappa (QWK) of 0.398 (vs. 0.322) and a dichotomized macro-F1 score of 0.711 (vs. 0.663) against the best-performing baseline. X-LMC performance also aligns with the observed clinical inter-rater agreement (QWK: 0.314). As the first DSA study attempting to automate LMC scoring, we demonstrate that multi-view temporal deep learning can capture collateral-specific contrast kinetics. Ultimately, these benchmarks delineate the clinical ambiguities and achievable performance boundaries of automated ASITN/SIR grading, establishing a reproducible foundation for objective hemodynamic phenotyping in stroke cohorts. Code is available at https://github.com/maedehafezi/X-LMC.

0.45

High-resolution retinal matrix imaging via computational motion and aberration correction

eess.IV physics.opticsphysics.app-phphysics.med-ph ·2026-10-13 ·Aymeric Melt, Léo Puyo, Victor Barolle, Claude Boccara, Gereon Hüttmann +1 more
unusual similarity 0.50
Abstract · 46 pages, 9 figures

High-resolution optical imaging of the human retina is essential for diagnosing ophthalmic and neurodegenerative diseases. While adaptive optics combined with coherence gating can resolve retinal structures at the cellular scale, it requires complex, costly, and cumbersome hardware to physically correct for ocular aberrations and motion. Matrix imaging offers a powerful digital alternative by leveraging wave linearity to undo aberrations and multiple scattering; however, its in vivo deployment has been hindered by continuous, involuntary eye movements that destroy phase coherence during acquisition. Here, we overcome this fundamental barrier and demonstrate the first in vivo reflection matrix imaging of the human retina using an ultra-simplified optical setup without physical correctors. We introduce a fully computational framework that tracks and compensates for multi-axial ocular motion directly from raw interferometric data, thereby restoring the phase coherence of a multi-spectral distortion matrix. This enables local, high-order aberration correction to achieve diffraction-limited, volumetric imaging of retinal tissues. By shifting the hardware burden to physics-guided numerical computation, this paradigm opens the way for accessible, non-invasive, and high-resolution digital ophthalmology.

0.25

Mask2Restore: Self-Supervised Ultrasound Despeckling via Inpainting

eess.IV cs.CV ·2026-09-26 ·Xuesong Li, Yingtai Xu, Zhongliang Jiang, Nassir Navab, Yuan Bi
similarity 0.50
Abstract

Medical ultrasound (US) is inherently degraded by speckle, a granular interference pattern that is often treated as a complex form of noise in image restoration. However, unlike random noise, US speckle originates from coherent scattering within tissue and is therefore highly spatially dependent and deterministic under fixed acquisition conditions, making US speckle suppression fundamentally different from natural image denoising. Because speckle-free US targets are unavailable in practice, self-supervised denoising is necessary. Blind-spot networks (BSN) are the dominant self-supervised paradigm for natural images, but their pixel-wise masking strategy assumes spatially independent noise, an assumption poorly matched to US speckle, which is spatially correlated over multiple pixels rather than pixel-wise independent. To address this mismatch, we propose Mask2Restore, a self-supervised US despeckling framework that reformulates despeckling as contextual inpainting with block-wise masking on single noisy images. Unlike pixel-wise BSN masking, block-wise masking addresses this multi-pixel speckle correlation by removing locally correlated speckle neighborhoods and shifting the reconstruction cues used by the network from adjacent speckle correlations to broader anatomical context. We further introduce cross-resolution context regularization (CRCR), which suppresses residual speckle bias by enforcing consistency across multi-resolution predictions. Experiments on simulated and in vivo carotid US, unseen fine-structure cases, and downstream cardiac segmentation demonstrate improved speckle-detail trade-offs, better preservation of fine anatomical structures, and practical value for subsequent image analysis.

0.20

EMA-Based Subspace Tracking for Adaptive Artifact Subspace Reconstruction

eess.SP ·2026-09-28 ·Vishnu KN, Cota Navin Gupta
code/data similarity 0.49
Abstract · 6 pages, 2 figures, 2 tables. Code: https://github.com/NeuralLabIITGuwahati/EMA-ASR

Electroencephalogram (EEG) artifact removal remains a critical challenge for real-world brain-computer interface deployment due to non-stationary signal statistics and limited calibration availability. Artifact Subspace Reconstruction (ASR) provides an automated framework for variance-based artifact suppression but relies on a static calibration-derived covariance model, limiting stability under intra-subject drift and increasing sensitivity to parameter mis-specification. This work proposes an adaptive ASR framework based on exponential moving average (EMA) subspace tracking. By integrating short-horizon covariance estimation with slow recursive assimilation, the method establishes dual adaptation timescales that enable responsiveness to evolving EEG structure while preserving stability against transient artifacts. This formulation further promotes smoother operating characteristics across rejection thresholds, reducing sensitivity to hyperparameter selection in continuous deployment settings. Evaluated on 24-channel EEG recordings from 10 subjects with prominent blink artifacts across cognitive states, EMA-ASR achieved substantially stronger artifact attenuation than Original and memory-limited ASR variants (53.1% vs. 24.0% and 26.7% blink reduction), at the cost of increased reconstruction and spectral deviation, whereas the memory-limited variant performed comparably to Original ASR. These findings position EMA-based adaptive tracking as a lightweight, deployment-oriented approach to continuous EEG artifact removal under non-stationary conditions, with an explicit trade-off between suppression strength and signal preservation.

0.51