CS Paper Radar

Daily listing

2026-11-03 · eess.IV

11 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 11

Benchmarking Neural Image Compression with DCT-Based Spectral Diagnostics

eess.IV cs.CV ·2026-11-03 ·Nikolay I. Kalmykov, Razan Dibo, Yujun Du, Yipeng Liu, Ivan Oseledets +1 more
benchmarkcode/data
Abstract · 17 pages, including supplementary material. Code: https://github.com/nkalmykovsk/dct_benchmark_nic

Neural image compression (NIC) models are commonly evaluated with scalar rate-distortion metrics, which do not show how a codec treats individual spatial frequencies. We propose a benchmark that probes codecs with the DCT basis matrix and single-frequency test images. We measure relative off-target energy (leakage), the fraction of reconstruction energy outside the probed frequency, together with target-frequency gain. Exact decompositions and bounds relate these measurements to reconstruction error. At operating points nearest 1 bpp, the BMSHJ, MBT, and Cheng2020 models leave 80-97% of their reconstructed high-band energy outside the target bin and have target-frequency gains of 0.02-0.23, whereas TCM and FTIC attain off-target energy in the classical-codec range. Both probe types identify behavior absent from scalar metrics: released Cheng2020-Anchor models produce extreme pre-clamp outputs on isolated single-frequency inputs. Finally, decoder-only fine-tuning with natural-image and leakage losses reduces basis off-target energy by 90-99.8% across all eight evaluated architectures while keeping the bitstream fixed, at a Kodak PSNR cost of 0.09-0.59 dB.

0.42

Neuromorphic Camera for Multi-Target Pointing Acquisition and Tracking in Free Space Optical Communication

eess.IV physics.optics ·2026-11-03 ·Francesco Nardo, Nigitha Selvaraj, Klaus Schertler, Peter Krötz, Ricardo Barrios +2 more
published
Abstract · 16 pages, 11 figures, 3 tables including 3 appendices. This paper has been accepted for invited presentation at SPIE Sensors + Imaging 2026,…

Pointing, Acquisition, and Tracking (PAT) in Free-Space Optical Communication (FSOC) applications must achieve both low jitter and a large Field of View (FoV) to support beacon acquisition and multi-target tracking. While conventional frame-based sensors provide the necessary angular coverage, their performance is limited by latency, available frame-rate, and motion blur. This work explores and demonstrates the application of an event-based vision sensor for PAT tasks in FSOC. The system employs a neuromorphic sensor that asynchronously records brightness changes (events) with microsecond-level temporal resolution. The main contribution of this paper is a comparative analysis of event-based tracking algorithms for the simultaneous acquisition and tracking of multiple optical beacons that operate directly on this asynchronous stream. The performance of these strategies is validated on an experimental dataset representing realistic operational conditions for dynamic High-Altitude Platform (HAP) and Unmanned Aerial Vehicle (UAV) networks. The analysis compares key metrics, such as tracking accuracy and processing latency, under various signal-to-background conditions.

0.34

Deep Plug-and-Play Proximal Distance Algorithm for Robust Principal Component Analysis

eess.IV eess.SP ·2026-11-03 ·Guanhua Liu, Mingjie Shao, Wenxuan Sun, Zhi Liu, Yanlong Zhao
published
Abstract

Robust Principal Component Analysis (RPCA) is essential in signal processing, with applications in hyperspectral imaging, face recognition, and video background modeling. Traditional RPCA methods often suffer from insufficient utilization of data priors and struggle to capture complex image structures. Conversely, advanced deep denoisers like DnCNN, FFDNet, and DRUNet excel at leveraging image data priors but lack physical model constraints and demonstrate poor robustness against structured noise in RPCA tasks. This paper proposes a novel Plug-and-Play (PnP) method for multi-channel RPCA, integrating both the physical generative model and cutting-edge deep priors. Extensive experiments on RGB and hyperspectral datasets show that PnP-PDA achieves better quantitative performance than conventional RPCA methods and state-of-the-art methods, including deep denoisers and tensor RPCA approaches, while preserving visual details.

0.31

Can saliency maps flag chest radiograph classifier errors at a new hospital? An external validation study

cs.CV cs.LGeess.IV ·2026-11-03 ·Aashish Chapagai, Angad Singh Gurtatta, Erik Cambria
code/data
Abstract · 21 pages, 5 figures, 1 table, 6 Extended Data figures and 4 Extended Data tables. Code: https://github.com/aashish-chapagai/CXR-Saliency-Ext…

Saliency maps are offered as a safeguard for medical image classifiers, but whether they reveal individual errors at a new hospital remains largely untested. We trained a convolutional network and a vision transformer on NIH ChestX-ray14 and evaluated 303,768 decisions per model at the training hospital and at two external sites, in the USA and Vietnam, with radiologist-consensus labels. We scored each explanation by its anatomical enrichment, the area-normalized concentration of attribution in a segmented thoracic region, and tested whether it detects errors beyond the model's confidence. Grad-CAM localized findings less often than radiologists (hit rate at most 0.575 versus 0.888). Adding enrichment to a confidence-based error detector calibrated at the training hospital never raised its area under the curve by more than 0.011, and for the convolutional network the relation between enrichment and correctness reversed between hospitals, degrading the transferred detector. Model confidence, not saliency, should anchor deployment monitoring.

0.28

Label-Preserving Fourier Domain Adaptation with Generative-AI and Real Style Donors for 3D Mitral Valve Segmentation

eess.IV cs.CV ·2026-11-03 ·Javeria Javed, Ahmed Salim, Muhammad Mahboob Ur Rahman
Abstract · 7 pages, 1 figure, 3 tables, submitted to IEEE for possible publication

Accurate segmentation of the mitral valve from three-dimensional transesophageal echocardiography (3D TEE) is severely restricted by the scarcity of publicly available expert- annotated volumetric datasets. To address this critical limitation, we investigated Fourier Domain Adaptation (FDA), utilizing general-purpose generative-AI images (from platforms like Chat- GPT, Google Gemini, and Microsoft MAI) as annotation-free style donors for 3D mitral valve segmentation. We employed a DeepMitral residual U-Net model on the public MVSeg2023 dataset, comparing six conditions over three runs: real-only training, traditional augmentation, FDA with each generative source, and a non-AI FDA control using real-image style donors, plus an optimization-matched real-only control and a \b{eta} sensitivity analysis. Case-level paired testing showed that FDA with these generative sources led to significant reductions in boundary- and surface-related errors across all three donor conditions relative to the primary real-only baseline. However, the impact on the core segmentation metric, Generalized Dice Score (GDS), proved generator-dependent. ChatGPT-FDA showed a significant GDS advantage over the optimization-matched control but not over the primary baseline, and Gemini-FDA showed no significant GDS difference. Notably, only MAI-FDA provided a statistically robust and significant increase in GDS compared to the primary baseline. The \b{eta} sensitivity was not robust across training runs. These findings confirm that FDA remains an important augmentation mechanism. While generative-AI images offer a practical means of acquiring style diversity without new annotations, the non-AI control performed comparably to ChatGPT-FDA, so we do not conclude that this approach is superior to training with real-image donors.

0.24

ELiCv2: Learned LiDAR Geometry Compression under Real-Time Embedded Constraints

eess.IV ·2026-11-03 ·Soowoong Kim, Junsik Kim, Gun Bang, Jinsoo Choi
Abstract

Improving learned LiDAR compression increasingly relies on heavier inference, making it harder to meet the constraints of real-time embedded systems. We present ELiCv2, which removes two sources of redundant computation in progressive coding. Its discrete entropy interface selects a precomputed integer CDF instead of materializing one from a per-voxel distribution, while its occupancy-driven kernel-map builder derives finer-level sparse-convolution kernel-maps directly from the decoded hierarchy, eliminating coordinate-based neighbor search. ELiCv2 reinvests the recovered computation budget in lightweight ego-motion-aware temporal conditioning that gathers local occupancy context from the aligned previous reconstruction. On four LiDAR datasets and an NVIDIA Jetson Thor, ELiCv2 achieves a mean BD-rate reduction of 30.97% over G-PCC with channel width C=32 while sustaining the 20Hz nuScenes capture rate. Increasing the channel width to C=64 improves the mean reduction to 35.22%.

0.24

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.23

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.22

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.22

Token Importance-Aware Semantic Communication Enabled Robust Video Transmission

eess.IV cs.AIcs.MM ·2026-11-03 ·Xiwen Zhang, Yubo Peng, Luping Xiang, Kun Yang
Abstract

Video applications are increasingly prevalent, yet their high data volume and temporal dependency make robust wireless transmission challenging under limited communication resources. To address this issue, we propose a token importance-aware semantic communication (Ti-SemCom) framework for bandwidth-efficient video transmission. Specifically, object and motion information is jointly extracted to identify communication-relevant regions, which are hierarchically associated with semantic tokens according to their importance. The transmitted tokens are then dynamically selected based on both token importance and the available bandwidth, prioritizing more informative video content under resource constraints. At the receiver, untransmitted regions reuse recently reconstructed references to further reduce redundant transmission. Experiments on the CAVIAR dataset show that Ti-SemCom can achieve an 88.3\% reduction in communication cost while maintaining competitive reconstruction quality.

0.16

Sparse-View 3D Coronary Reconstruction from Vessel Segmentations Using a Diffusion Prior

eess.IV cs.CV ·2026-11-03 ·Tianyuan Wang, Kenan Niu, Stefano Stramigioli
Abstract · 10 pages, 5 figures, 2 tables

Reconstructing three-dimensional (3D) coronary anatomy from sparse angiographic views could support percutaneous coronary intervention, but limited angular coverage and imperfect vessel segmentations introduce substantial geometric ambiguity. We propose a vessel-specific reconstruction framework combining a learned 3D diffusion prior, visual-hull initialization, and projection-based data consistency. The unconditional diffusion model is trained on coronary vessel masks without paired 2D--3D data and reused across different view counts without retraining. During inference, a scaled visual hull initializes reconstruction, while projection-based updates constrain diffusion refinement using patient-specific vessel observations. We evaluated the framework on simulated angiograms derived from ImageCAS computed tomography angiography volumes using two, four, and eight views at two contrast levels. Across 50 evaluation coronary-tree cases, the proposed method achieved higher mean Dice and clDice than visual hull, deep image prior (DIP), and hash-grid implicit neural representation (INR) at all view counts under reduced contrast. With eight views, improvements over DIP, the best-performing baseline at lower contrast, were approximately 0.13 in Dice and 0.22 in clDice. At higher contrast, performance remained competitive with hash-grid INR, the best-performing eight-view baseline. The preferred diffusion starting timestep depended on observation quality and view count, with excessive refinement reducing accuracy at higher contrast. Projection guidance improved both metrics across all conditions. Averaging stochastic reconstructions further improved accuracy, while sample disagreement localized errors with average-precision gains of 0.14--0.21 over error prevalence. These findings support diffusion-prior reconstruction from sparse vessel observations, although clinical validation remains necessary.

0.11