CS Paper Radar

Daily listing

2026-11-04 · eess.IV

12 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 11

TOP: Transmission-Oriented Remote Sensing Pansharpening

eess.IV cs.CV ·2026-11-04 ·Zi-Han Cao, Jing-Ze Liang, Shao-Jie Wu, Jin-Cheng Di, Liang-Jian Deng +1 more
code/dataunusual
Abstract

Pansharpening has been extensively studied as a fundamental image fusion task in remote sensing. However, most existing methods focus on improving fusion quality under the implicit assumption that high-resolution observations have already been fully downlinked to the ground. As a result, existing models are highly vulnerable to perturbations introduced by lossy compression used for downlink transmission. To address this limitation, we present, to the best of our knowledge, the first transmission oriented pansharpening (TOP) framework, which unifies compact latent coding, onboard pansharpening, and efficient downlink transmission within a single satellite-toground pipeline. TOP encodes remote-sensing observations into a compact binary latent space, where a lightweight onboard fusion module can efficiently predict the fused binary latent code. Since only the compact fused code is downlinked, the transmission payload is substantially reduced. Overall, TOP enables low-payload downlink and lightweight onboard processing while maintaining high fusion quality under severe bandwidth constraints. Experiments across multispectral and hyperspectral settings show that TOP consistently achieves superior fusion quality at higher compression ratios than representative pansharpening methods paired with standard lossy codecs. For example, on GaoFen-2, TOP attains a fusion PSNR of 31.4 dB at a downlink compression ratio of 50x. This design also points toward transmissionoriented processing for other remote-sensing tasks. The code will be made available at https://github.com/JingZe-Liang/TOP.git.

0.43

Dual Flow: Joint Image-Measurement Flow for Inverse Problems

eess.IV cs.CV ·2026-11-04 ·Sevket Ege Yesilyurt, Figen S. Oktem
code/data
Abstract · 17 pages, 8 figures. Our code is available at https://github.com/METU-SPACE-Lab/Dual-Flow

Existing generative model-based approaches to linear inverse problems typically use the acquired noisy measurement to condition or guide sampling in the image domain. In this work, we introduce Dual Flow, a novel joint flow model for solving linear inverse problems by jointly estimating the clean image and its corresponding noise-free measurement from the observation. Specifically, Dual Flow formulates image reconstruction and measurement denoising as a coupled estimation problem, using coupled flows in the image and measurement domains. The acquired noisy measurement $\mathbf{y}_0$ is used only to initialize the measurement state; thereafter, the image and measurement states are jointly updated based on their current values. By construction, the final image and measurement estimates are guaranteed to satisfy the underlying forward model. We derive the sampling updates for the joint flow and show that they are governed by the conditional mean of the clean image given the current joint state. We further derive a closed-form expression for a sufficient statistic of the joint state and show that the required conditional mean can be obtained by solving an image-domain Gaussian denoising problem involving operator-dependent, correlated noise. We train a velocity-prediction network using this formulation to estimate the conditional mean from the derived sufficient statistic. Dual Flow requires no hyperparameter tuning beyond selecting the number of inference steps and achieves substantially shorter reconstruction times than competing methods. Extensive experiments across various linear inverse problems and image datasets demonstrate state-of-the-art performance in both distortion metrics and perceptual quality. Additional analyses assess robustness to model mismatch, as well as the ability to generate diverse plausible reconstructions and characterize reconstruction uncertainty.

0.40

Subliminal Learning in Vision-Language Models

cs.CV cs.AIcs.CLcs.LG+1 ·2026-11-04 ·Arman Hatami, Romina Aalishah, Ilya E. Monosov
published
Abstract · Accepted to WACV 2027

Subliminal learning is a phenomenon in large language models (LLMs) where a teacher passes a hidden preference to a student through training data unrelated to that preference. We study whether subliminal learning also occurs in vision-language models (VLMs). We finetune a teacher VLM to prefer a specific animal or facial attribute and use a control teacher from the same base model. Both teachers generate numbers for an unrelated visual task involving geometric shapes. Two students initialized from the same base VLM are finetuned on the same images, using numbers generated by either the biased or control teacher. Across VLMs ranging from 2B to 7B parameters, we find that both animal and facial preferences can transfer through this unrelated task. Students trained on biased-teacher outputs select the target more often than control students, with a difference of up to $\sim$10 percentage points in the animal preference task. Transfer can become stronger with more training data and varies with the target preference, model, and how the numbers are generated. Beyond preferences, we show that the biased student's explanations use more of the same words and phrases as the biased teacher's explanations than those of the control student, even when all three models select the same image. These results matter for training VLMs and show that training on unrelated data may change both a VLM's image preferences and how it explains its choices, and that transfer can become stronger with more training samples.

0.36

Task-Aware Bitrate Thresholds for Codec-Robust Ultrasound Segmentation

eess.IV ·2026-11-04 ·Alireza Siyavashi, Arman Shirzad, Christian Herglotz
published
Abstract · It is already accepted at IEEE Visual Communications and Image Processing Conference

Remote robot surgery and tele-ultrasound increasingly rely on real-time streaming under strict bandwidth constraints, making lossy compression unavoidable. Since the receiving end of these clinical pipelines is increasingly a machine rather than a human observer, codec selection must be guided by downstream task accuracy rather than perceptual fidelity. We evaluate three widely deployed codecs, H.264/AVC, HEVC, and AV1, on prostate ultrasound segmentation, reporting task-aware compression performance with region overlap (Dice) and boundary accuracy (HD95) as the quality metrics. To compare codecs fairly, we match their operating points at a common perceptual-quality (SSIM) level. We establish, per codec, the lowest bitrate that preserves acceptable segmentation accuracy, reporting the 5th-percentile Dice alongside the mean to expose worst-case degradation. All three codecs preserve segmentation quality (mean Dice $\geq$ 0.84) down to approximately 0.07-0.20 bits per voxel (bpv). Below this point, AV1's accuracy declines gradually, while H.264's drops sharply. As a result, H.264 needs 82% more bitrate than AV1 to reach the same region-overlap accuracy (Dice), and 104.7% more to reach the same boundary accuracy (HD95).

0.32

Perturbation-Based Reconstruction of Depth-Resolved OCT Attenuation without Requiring a Fully Decayed Signal Tail

eess.IV physics.optics ·2026-11-04 ·Jinglun Yu, Yaning Wang, Shuwen Wei, Jin U. Kang
unusual
Abstract · 26 pages, 10 figures, including 1 supplementary figure. Submitted to Biomedical Optics Express

Depth-resolved attenuation in optical coherence tomography (OCT) can provide quantitative optical contrast beyond structural imaging. However, conventional reconstruction methods can be biased when the OCT signal does not fully decay within the imaging range or when the distal signal tail is dominated by noise or residual reflections from distal sample or support interfaces. Here, we present a perturbation-based Beer-Lambert framework that combines a zeroth-order exponential estimate with a first-order correction, reducing reliance on the unreliable distal signal tail below the current depth. Numerical A-line simulations, Monte Carlo modeling, multilayer silicone-dye-TiO2 phantoms, and ex vivo bovine retina experiments were used to evaluate the method under finite-depth and heterogeneous imaging conditions. The numerical A-line tests showed reduced depth-dependent error against prescribed attenuation profiles; the Monte Carlo comparisons showed less distal drift relative to model-defined benchmarks, while the phantom profiles were compared with separately acquired single-layer OCT calibration values. In a Monte Carlo component test that withheld vessel-mask and vessel-boundary information from reconstruction and used that information only for post hoc evaluation, the first-order correction recovered 61% of the segmentation-informed target vessel contrast and reduced vessel ROI mean absolute error by 65% relative to the fixed zeroth-order baseline. These results suggest that perturbation-based reconstruction may provide a practical approach for depth-resolved reconstruction of effective OCT attenuation when the fully decayed A-line condition is not satisfied.

0.30

Finite Element Elastographic Analysis of Kidney MRI for Computational Assessment of Chronic Kidney Disease

eess.IV ·2026-11-04 ·A. Bhattacharjee, M. M. Rahman, A. Srivastava, E. H. Bhuiyan
unusual
Abstract · Original research article

Background and Objective: Bridging kidney MRI with patient-specific computational biomechanics may enable accurate, noninvasive assessment of chronic kidney disease. To develop a finite element method (FEM)-based computational elastography framework for estimating renal biomechanical properties from conventional kidney MRI and to evaluate its ability to differentiate chronic kidney disease (CKD) from healthy controls. Methods: Kidney segmentation masks from healthy control and CKD subjects were converted into triangulated surface meshes, and watertight surfaces were tetrahedralized to create volumetric FEM meshes. Kidney tissue was modeled as a nearly incompressible Kelvin-Voigt viscoelastic material. Harmonic wave propagation simulations were performed using FEM, followed by Helmholtz-based elastographic inversion to estimate complex shear modulus distributions. Derived biomechanical parameters were used for CKD classification using machine learning models. Results: FEM-derived stiffness estimates showed consistency with stiffness ranges previously reported in human renal MRE studies and also showed measurable differences between healthy and CKD groups. Machine learning models trained on FEM-derived features achieved classification performance up to 86.26% cross-validation accuracy with an AUC of 0.92. Conclusion: FEM-derived elastographic parameters showed potential for distinguishing CKD from healthy tissue and may provide an alternative for renal biomechanical assessment without dedicated MRE acquisition.

0.26

Destructive augmentations for prostate lesion segmentation on heterogeneous biparametric MRI data

eess.IV ·2026-11-04 ·Thibault Heintz, Rachit Saluja, Seungbin Park, Daniel Margolis, Timothy McClure +2 more
benchmark
Abstract

Training prostate lesion segmentation models on biparametric MRI (bpMRI) is limited by small datasets with heterogeneous imaging acquisition protocols and annotations. In this work, we train a segmentation model on a combined cohort of 1,579 lesion-containing training cases from five datasets, representing, to our knowledge, the largest collection of prostate lesion annotations used for this task. Additionally, we investigate two complementary improvements to the widely used nnU-Net framework. First, we introduce a random wavelet augmentation and show that random sym4 (Symlet) wavelets outperform random convolution augmentation in terms of average Dice score, with only a modest reduction in F1 score due to lower precision. Second, we evaluate instance-level losses and show that Connected-Component-based Dice (CC-Dice)-CE loss complements BackSplit, yielding better performance than BackSplit alone. Together, these improvements achieve the best overall performance, reaching a Dice score of 0.614 on the public Prostate158 test set and establishing a new state-of-the-art on this benchmark. We publicly release our training code and model weights.

0.25

CNVAE: Anatomically Correct Segmentation via Conditional Generative Modeling

eess.IV ·2026-11-04 ·Freddy Jiang, Loic Le Folgoc, Elsa Angelini
Abstract

Supervised deep learning segmentation models, although unparalleled in performance, are not immune to anatomical mistakes. We develop a segmentation-by-generation paradigm extending the Nouveau VAE (NVAE) generative framework for anatomically correct cardiac segmentation. In particular, we propose a novel conditional NVAE model (CNVAE) for conditional shape generation, and explore its capabilities for image segmentation in two scenarios: (1) direct image-to-mask CNVAE for one-step segmentation; (2) mask-to-mask CNVAE for refinement of segmentation masks produced by third-party segmentation models. Both models are lightweight and return consistently anatomically valid segmentation masks (> 98% success rate, an improvement of 15% above state-of-the-art segmentation models) on the cardiac segmentation/editing tasks of interest, without loss of accuracy in segmented contours.

0.25

Arctic-SAR: A Cross-Sensor RADARSAT Constellation Mission and Sentinel-1 Dataset and Fusion Benchmark for Multi-Task Sea Ice Mapping

eess.IV ·2026-11-04 ·Niloofar Azad, Kyle Gao, Javier Noa Turnes, Youssef Nafea, Linlin Xu +1 more
benchmark
Abstract

Current sea ice mapping benchmarks are mostly built around single-sensor SAR products, limiting the evaluation of cross-sensor variability and the effectiveness of combining observations from different SAR platforms. Models trained on such datasets may also be sensitive to sensor-specific artifacts, radiometric characteristics, and acquisition conditions, which can reduce robustness and limit generalization. To address these limitations, this study introduces Arctic-SAR, a cross-sensor SAR dataset for Arctic sea ice mapping, constructed by matching RADARSAT Constellation Mission (RCM) dual-polarization imagery with Sentinel-1 scenes from the AI4Arctic Sea Ice Dataset. The dataset consists of 221 co-registered scenes and supports multi-task prediction of sea ice concentration (SIC), stage of development (SOD), and floe size (FLOE). In addition to the dataset, we establish a benchmark for cross-sensor SAR sea ice mapping by quantifying the contribution of RCM imagery and evaluating single-sensor baselines alongside representative input-, feature-, and decision-level fusion strategies within a consistent multi-task U-Net framework. Across three independent runs, the test results show that the effectiveness of cross-sensor fusion is strongly dependent on the fusion strategy and prediction task. Decision-level fusion achieves the highest mean combined score of $77.28\pm0.29\%$, essentially matching the Sentinel-1-only baseline at $77.26\pm0.13\%$, while achieving the highest SIC \(R^2\) score. These findings show that Sentinel-1 and RCM provide task- and class-dependent information, but that simple joint cross-sensor fusion does not consistently improve generalization over a strong single-sensor baseline. Arctic-SAR therefore provides a benchmark for cross-sensor SAR fusion research in automated Arctic sea ice mapping.

0.24

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.23

SideAge-RiskNet: Predicted Mammographic-Age Features for Future Breast Cancer Risk and Laterality Prediction

eess.IV ·2026-11-04 ·Haoyan Ding, Encheng Su, Chaowei Wu, Lixia Wang, Qian Wang +4 more
Abstract · 5 pages, 2 figures

Whether breast-specific mammographic aging provides information beyond chronological age for future cancer prediction remains unclear. We propose SideAge-RiskNet, a framework integrating predicted mammographic-age features with breast-specific representations for multi-year breast cancer risk and conditional laterality prediction. A side-aware DenseNet121 trained on never-cancer reference examinations estimates left and right breast ages. Age-adjusted residuals and bilateral age descriptors are subsequently fused with corresponding image representations, while clinical variables contribute through an image--clinical risk branch. The framework jointly predicts cumulative cancer risk over 1--5 years and the subsequently affected breast among unilateral cancer cases. Across 4,480 EMBED and 248 external examinations, pre-cancer scans demonstrated pronounced bilateral age asymmetry. SideAge-RiskNet established state-of-the-art performance in 1--5-year risk assessment over Mirai and AsymMirai with mean risk AUROCs of 81.73% on EMBED and 72.83% on CSMC. Furthermore, it enabled conditional cancer laterality prediction, achieving AUROCs of 73.26% and 82.53%, respectively. This demonstrates the critical utility of bilateral aging phenotypes in localized breast cancer risk surveillance.

0.20

People & Society 1

A Frame-Level View and Image-Quality Annotation Tool for Fetal Echocardiography: Comparison with Spreadsheet Annotation

cs.HC eess.IV ·2026-11-04 ·Mohamed Azzam, Ziyang Xu, Quinlan Couch, Zoe Keese, Andrea Cadlo +11 more
Abstract

Objective: To develop the Cardiologist Annotation Tool (CAT) for frame-level cardiac view and image-quality annotation in fetal echocardiography and compare it with spreadsheet-based annotation. Methods: CAT provides cine playback, frame navigation, and keyboard-based labeling without manual frame-range entry. Experts annotated 25 studies using both methods, and spreadsheet annotations were audited for predefined data-entry errors. In a randomized crossover study, six medical students annotated two normal studies, one with each method, against an expert reference. Results: Among 1,746 spreadsheet-annotated files, 6.2% contained major or critical data-entry errors, more frequently in congenital heart disease than normal studies (10.9% vs 3.4%). CAT yielded more annotated view segments per clip (3.6 vs 1.5). Rates of labeled and correctly labeled frames per minute were 1.77 and 1.68 times those with spreadsheets, respectively (both P = 0.031), with gains in all six students. No detectable difference in view-label accuracy was observed. Conclusion: CAT eliminates manual frame-range entry and enables finer-grained, structured annotation of fetal echocardiography, providing a practical approach to preparing datasets for AI research.

0.26