CS Paper Radar

Daily listing

2026-11-11 · eess.IV

15 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 14

Mutual Colormap Dependence: How Recoloring Biomedical Images Changes Vision-Language Model Answers

eess.IV ·2026-11-11 ·Siddharth Vohra, Runmin Jiang, Min Xu
publishedcode/data
Abstract · Accepted to the FABRIC workshop at WACV 2027. 10 pages, 1 figure, 5 tables. Project page: https://siddvoh.com/mutual-colormap-dependence/

Vision-language models (VLMs) are being built to answer questions about biomedical images, yet they never see the measured intensities, only the colors that a colormap has assigned to them. For questions about image content, the colormap should not change the answer. We call the extent to which it does Mutual Colormap Dependence (MCD), the mutual information between the colormap and a model's answer, which is zero exactly when every colormap yields the same answer distribution. Because VLMs sample their answers, we compare recoloring with a control that uses the same number of calls to ask again about the unchanged gray image, so that ordinary resampling is not mistaken for an effect of the colormap. We test GPT-5.4, Gemini 3.1 Pro, Claude Sonnet 4.6, and Qwen3-VL-235B under six luminance-monotonic colormaps (gray, viridis, plasma, inferno, magma, and cividis) on 50 medical visual-question-answering items from 16 SLAKE images, 64 ChestX-ray14 chest radiographs, and 200 BBBC039 fluorescence-microscopy images for exact nucleus counting. Every prompt tells the model to ignore the colormap. Even so, with three answers per colormap on the chest radiographs, the answers of all four models depend on the colormap (all Holm-adjusted $p \leq 0.002$). For Claude, some colored map overturns the majority answer on 29 of the 64 radiographs, where resampling gray alone overturns about 4, and Qwen's accuracy falls from 0.54 under gray to between 0.32 and 0.41 under the colored maps, mostly because it abstains. With one answer per colormap, recoloring adds disagreement beyond repeated sampling in 5 of 12 model-panel cells under per-cell 95% intervals, and repeating the instruction to ignore color does not reliably reduce it. The colormap is therefore part of what a VLM sees, and it can change the answer.

0.37

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36

Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

eess.IV cs.CLcs.CVcs.LG ·2026-11-11 ·Shreya Ajay Kale, Angad Ripudaman Singh Bajwa
published
Abstract · Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS…

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

0.33

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Hybrid quantum learning for imbalanced blood-cell classification: domain adaptation and classifier design

eess.IV cs.LG ·2026-11-11 ·Gabriele D'Angeli, Cyrill Aebischer, Eryk Schiller, Gianluca Nicchiotti, Su Fong Chien +2 more
benchmark
Abstract · Submitted to Quantum Machine Intelligence

Limited annotated data, class imbalance, and morphological similarity make white blood cell classification challenging. We benchmark hybrid variational quantum classifier heads against an affine baseline on 821 microscopy images across seven morphological classes. Using ImageNet-initialised ResNet34 backbones and repeated stratified five-fold cross-validation, we first compare direct transfer with intermediate adaptation on MLL23, a larger peripheral blood cell microscopy dataset. To guide the head comparison, we explore different encoding strategies, variational depth, and the number of independent circuit blocks. We then compare the classifier performance using the affine head and two hybrid heads across multiple random seeds, under a shared training and evaluation protocol. For this comparison, all backbones share the same MLL23-adapted initialisation. Intermediate adaptation increases mean macro-F1 across all four affine-head fine-tuning configurations. The largest gain occurs with a frozen backbone, where macro-F1 rises from $0.685$ to $0.786$, a relative improvement of approximately $14.7\%$. The shallow two-block hybrid head achieves a mean pooled out-of-fold macro-F1 of $0.865 \pm 0.010$, compared with $0.879 \pm 0.008$ for the affine head. The corresponding balanced accuracies are $0.886 \pm 0.008$ and $0.889 \pm 0.010$, respectively. In the architectural exploration, the two-block hybrid head achieves the highest macro-F1 and balanced accuracy among the evaluated hybrid configurations, while the effect of encoding varies across the considered metrics. Our results help guide the design and evaluation of hybrid classifier heads for imbalanced microscopy by linking architectural choices to overall performance and class-specific precision-recall trade-offs.

0.26

Information about Optic Nerve Head Biomechanics is Already Coded in Your Clinical Charts and Can be Used to Predict Glaucoma Progression

eess.IV ·2026-11-11 ·Yibo Chen, Patipol Tiyajamorn, Charis Y. N. Chiang, Deepta Ghate, Thanadet Chuangsuwanich +1 more
unusual
Abstract · 43 pages, 6 figures, 1 table

Glaucoma patients routinely undergo optical coherence tomography (OCT) imaging and intraocular pressure (IOP) assessment as part of standard care. Because IOP typically differs across visits, it is possible to map visit-to-visit ONH strains by registering OCT volumes acquired under different IOPs. These strains reflect ONH elasticity and, over longer intervals, also capture growth and remodeling of the ONH. In this study, we evaluated whether such visit-to-visit ONH strain signatures could serve as predictors of glaucoma progression. We retrospectively analyzed 525 eyes from 430 glaucoma patients (238 fast and 287 slow progressors), defining fast progression by a visual field index slope of -1.5% per year or worse. 3D strain maps were derived from baseline and follow-up OCT scans using AI. Predictions using T=1 to T=4 follow-up visits were evaluated by five-fold cross-validation in a long-term cohort (T=1: 1.30 years; T=4: 5.26 years) and short-term testing (T=1: 0.46 years; T=4: 1.25 years). Overall, IOP differed between paired visits in 92% of cases. Long-term T=1 prediction achieved an area under the receiver operating characteristic curve (AUC) of 0.74 and accuracy of 0.72. A single short-term follow-up (T=1) yielded an AUC of 0.75 and accuracy of 0.71; four follow-ups yielded an AUC of 0.87 and accuracy of 0.82. SHapley Additive exPlanations (SHAP) identified neuroretinal rim compression and prelaminar elongation associated with fast progression, with substantial inter-eye variability. Overall, visit-to-visit ONH strains derived from routine OCT predicted glaucoma progression after a single follow-up visit at a mean interval of 0.46 years. These findings suggest that short-term OCT/IOP assessments could provide valuable insights into ONH biomechanics, identify eyes at risk of rapid progression, and reveal distinct strain signatures associated with disease progression.

0.26

Real Pairs Are Not Enough: Physically Anchored Supervision for Volumetric CT Super-Resolution

cs.CV eess.IV ·2026-11-11 ·Haoran Liu, Zipei Yan, Mingzhe Liu, Jizhou Li, Guibin Zan
Abstract · 47 pages, 5 figures, including supplementary material

Volumetric CT super-resolution (SR) models are commonly trained on synthetic or physically acquired pairs of low-resolution (LR) and high-resolution (HR) volumes. However, synthetic pairs miss real acquisition effects, whereas registered physical pairs retain inter-scan noise, artifact, and microstructure differences---causing direct voxelwise regression, and even naive synthetic-real mixing, to oversmooth fine porous structures. We introduce the Physically-anchored Implicit Network (PIN) with Real-Pair Dual-Anchor learning, which decouples physical-pair supervision into two complementary roles. The HR anchor teaches fine structure from registered HR through pair-conditioned spectral replay, while the LR anchor constrains the prediction from acquired LR via affine-calibrated low-pass projection. Together with exact synthetic supervision in one shared volumetric implicit model, PIN learns from both physical scans without forcing the acquired-LR reconstruction to match registered HR voxel by voxel. Inference requires only acquired LR. Across 30 external baseline configurations on real CT, PIN achieves the lowest full-volume LPIPS, reduces average symmetric surface distance by 42.3-49.5% and bone-volume-fraction error by 52.2-53.4% relative to the three strongest baselines for each metric, and lowers the erased reference-pore volume fraction from 37.3-72.9% to 10.4%. Code, pretrained models, and evaluation scripts will be publicly available.

0.26

Interpreting Selective-Review Coverage for Head-and-Neck Auto-Contours

eess.IV ·2026-11-11 ·Jaden Moon, Caiwen Jiang, Songlin Zhao, Wei Liu
unusual
Abstract · 5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

Selective-review systems aim to reduce human review by passing candidates predicted to be low risk. However, coverage (the fraction passed) can be misleading when measurements needed to interpret risk are unavailable. We separate structural evaluability (a nonempty mask with all required measurements available), computational-endpoint status, and pass-or-review decisions using archived Mayo records and controlled OpenKBP analyses. In 3,968 Mayo records, all 1,167 recorded empty predictions (predicted target-organ masks containing zero voxels despite nonempty reference masks) were endpoint-negative and passed both modules, accounting for approximately 76% of each pass set. In a held-out OpenKBP test, a logistic-regression router achieved an area under the receiver operating characteristic curve of 0.833 and average precision of 0.449 but passed all 544 non-evaluable candidates, including 542 prespecified empty-mask controls and 2 erosions that became empty. A structural gate removed those passes without changing scores or the threshold, preserved all evaluable passes, and assigned 98.71% of endpoint-positive candidates to review. Under the original preprocessing and in patient-disjoint development evaluation, a router trained only on evaluable candidates and a router modeling an unavailable state likewise passed no non-evaluable candidates, with similar evaluable discrimination and at least 99.0% of endpoint-positive candidates assigned to review in pooled outer-fold predictions. These results show that coverage should be interpreted jointly with candidate eligibility, endpoint scope, missingness handling, and routing rules; they do not establish clinical validity, deployment safety, or natural-failure prevalence.

0.25

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.24

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

Supervision-Aware Evaluation of MedGemma for Reference-Assisted Radiotherapy Contour Ranking

eess.IV cs.CVcs.LG ·2026-11-11 ·Jaden Moon, Caiwen Jiang, Songlin Zhao, Wei Liu
Abstract · 5 pages, 1 figure, 3 tables. Submitted to IEEE ISBI 2027

Radiotherapy contour ranking can support quality assurance, but vision-language model (VLM) gains may reflect supervision, score construction, available inputs, or representation access. We evaluated frozen MedGemma 1.5 in a single-institution study, a 12-patient held-out HaN-Seg test, five-fold cross-fitting on 30 non-test HaN-Seg patients, and transfer without refitting to 120 SegRap2023 patients. On held-out HaN-Seg, a supervised readout of the final prompt state exceeded a supervised readout of the model's yes/no output probabilities by +0.3047 pooled average precision (AP; 95% patient-bootstrap interval [+0.2822, +0.3269]); the advantage persisted against a parameter-count-matched nonlinear control. A readout of projected visual tokens exceeded the final-state readout in cross-fitting and transfer (+0.0706 AP averaged equally across patients on SegRap; 95% interval [+0.0607, +0.0804]), while a structured panel-feature readout remained competitive with visual tokens. The anatomy-conditioned readout did not demonstrate an advantage over the native-feature comparator. These results motivate visual-token and structured-feature controls in medical-imaging VLM evaluations; outcomes were computational or synthetic, not clinical acceptability.

0.22

Learning Motion-Appearance Coupling Priors for Solving Video Inverse Problems

cs.CV cs.LGeess.IV ·2026-11-11 ·Anselm Krainovic, Reinhard Heckel
published
Abstract · NeurIPS 2026

Reconstructing video from degraded measurements requires priors that capture both frame appearance and temporal dynamics. Many recent approaches combine pretrained image diffusion priors with motion guidance, sidestepping the costs of training large video models. Temporal consistency is often enforced via photometric losses or warping-based constraints, which implicitly assume that motion explains frame-to-frame or latent-to-latent changes up to small deviations, an assumption that fails under occlusions, lighting changes, and non-rigid deformation. In this paper, we propose to learn the coupling between motion and frame appearance as a generative prior. We learn the distribution of motion-induced appearance residuals with a conditional diffusion model and use it to regularize reconstruction in video inverse problems. Our motion-appearance prior acts as a plug-in regularizer for diffusion-based video reconstruction, preserving the benefits of image diffusion models while remaining compatible with existing appearance regularization techniques. Experiments on dynamic video inverse problems show that reconstruction with a learnt motion-appearance coupling prior outperforms photometric-consistency and noise-warping baselines, and that the approach also transfers to cardiac MRI reconstruction.

0.20

ST-Dist: Distilling Spatial Transcriptomics Predictions into Interpretable Gene Axes for Distant Metastasis Prediction

eess.IV ·2026-11-11 ·Sandesh Pokhrel, Hamid Manoochehri, Beatrice S. Knudsen, Tolga Tasdizen
Abstract

Distant metastasis at diagnosis determines the treatment of prostate cancer, but predicting it from routine biopsy slides is challenging as the signs of metastasis are not clearly localized and are more subtle than in standard tumor detection and subtyping tasks. Multiple instance learning (MIL) on pathology foundation-model features has become the standard approach when labeled data are abundant, but such models remain hard to interpret. Distant metastasis is further challenging, because confirming the label requires clinical follow-up beyond the routine H&E slides. To this end, we propose ST-Dist, which distills the gene expression predicted by a spatial transcriptomics (ST) model into a linear head mapping each tile's foundation-model features onto named gene axes. The slide's projections along these interpretable gene axes are then used for distant metastasis prediction with a simple logistic regression. On 497 prostate needle biopsies (205 patients), ST-Dist reaches an AUROC of 91.37%, above nine MIL baselines. It remains competitive on the public TCGA-COAD and TCGA-KIRC cohorts, and it has the highest mean AUROC over the three cohorts. The ablations on the prostate biopsies show that the gene axes outperform a linear probe on encoder features, dimension-matched principal components, random gene panels and the ST model's own predicted expression, and the gain over the probe holds on all 13 pathology encoder settings that we tested. ST-Dist thus offers a simple, accurate and interpretable route from H&E to distant metastasis prediction.

0.12

HR-NVC++: Unified Ultra-High-Resolution Neural Video Coding with Confidence-Guided Spatial-Temporal Cues

eess.IV ·2026-11-11 ·Feng Ye, Lijiong Chen, Kai Zhang, Li Zhang, Chuanmin Jia
Abstract

Ultra-high-resolution neural video coding (NVC) remains challenging because temporal correspondence becomes increasingly unreliable as spatial resolution increases. Although recent neural B-frame codecs have improved bi-directional temporal prediction, complex motion and fine-grained structures still lead to unreliable temporal references, while spatial information of the current frame remains underexploited. In this work, we propose HR-NVC++, a unified ultra-high-resolution NVC approach that supports both fidelity-oriented and perceptual-quality-oriented compression with a shared spatial-temporal context. The context integrates bi-directional temporal cues with complementary spatial information: confidence-guided fusion adaptively balances the forward and backward temporal cues according to their estimated correspondence reliability, while a spatial complement branch enriches regions that temporal references fail to explain. The resulting context serves as a common basis for two compression modes. Built upon this shared context, the fidelity mode retains entropy-based latent coding for pixel-accurate compression, whereas the perceptual mode removes additional latent coding and performs reconstruction directly from the context. This design demonstrates that a sufficiently informative spatial-temporal context already carries the dominant content required for perceptually favorable reconstruction, allowing different compression objectives to share the same contextual representation. Extensive experiments on UVG-4K and JVET Class A1/A2 show that HR-NVC++ achieves an average PSNR BD-rate saving of 13.01% over the H.266/VVC reference model VTM-13.2 under the random access configuration, while delivering substantially better perceptual quality and temporal consistency than existing neural video codecs.

0.08

Robotics, Control & Signals 1

Physics-Informed Generative Augmentation for Open-Set UAV Classification

eess.SP eess.IV ·2026-11-11 ·Michel Kulhandjian, Levon Aslanyan
published
Abstract · Accepted by ICT Express

Open-set recognition of unmanned aerial vehicles (UAVs) from passive 5G radar micro-Doppler signatures is challenging because unknown drone types cannot be anticipated at training time. We propose a physics-informed generative adversarial network (PI-GAN) that conditions spectrogram synthesis on rotor kinematics, forcing the classifier's feature space to encode physically meaningful structure. We compare PI-GAN augmentation against a vanilla conditional GAN (CGAN) and basic data augmentation across three held-out configurations with 1, 2, and 3 unknown classes. Vanilla CGAN augmentation collapses open-set clustering, reducing the adjusted Rand index (ARI) from 0.97 to 0.01, whereas PI-GAN preserves it at 0.97. In a controlled held-out sweep with two unknown classes, PI-GAN achieves an ARI of 0.92 compared to 0.07 for vanilla CGAN. The physics-informed features enable unsupervised separation of mechanically distinct unknown drones without retraining, demonstrating that physics-conditioned generation is the key enabler of open-set capability.

0.38