CS Paper Radar

Life-Cycle Planning of Collector System for Deep-Sea Multi-Spatial Wind-PV-Tidal Farm

Wenhao Gao, Weitai Xu, Yunfei Du, Yongheng Wang, Xinwei Shen

eess.SY ·submitted 2026-08-10 10:33 UTC · v2
published

Abstract

This paper develops a life-cycle optimization model for the collector system (CS) of deep-sea co-located energy farms (CEFs), where co-located energy turbines (CETs) integrate wind, photovoltaic (PV), and tidal current resources across sea-area layers. The model captures multi-layer marine-space complementarity, wake effects, and output variability, while accommodating diverse dynamic submarine cable configurations. To improve computational efficiency, the adaptive piecewise linearization (A-PWL) method based on the outputs of CETs is proposed to transform the original mixed-integer quadratic programming (MIQP) problem into a mixed-integer linear programming (MILP) form to approximate quadratic operation costs and simplify absolute power flow modeling. Case studies demonstrate that incorporating multi-energy complementarity significantly enhances the economic performance of deep-sea CEFs. When external physical risks are negligible, the fully-suspended cable configuration proves more cost-effective than the lazy-wave design. The proposed linearization method achieves high accuracy while significantly reducing solution time. Overall, this work provides a practical and scalable framework for efficient CS planning in offshore renewable energy systems.

Comment
14 pages, 12 figures, and 6 tables. Accepted by CSEE Journal of Power and Energy Systems in August 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings Using Iterative McCormick Relaxation

eess.SY ·2026-10-27 ·Junseon Park, Hyeongon Park, Rahul K. gupta
benchmark similarity 0.58
Abstract

Grid Enhancing Technologies (GETs), such as Network Topology Optimization (NTO), Dynamic Line Rating (DLR), and Variable Impedance Devices (VIDs) are increasingly deployed in power transmission grids to address congestion and improve grid utilization. However, their growing adoption necessitates coordinated operation to fully exploit their benefits. This paper presents a unified co-optimization framework that integrates NTO, DLR, and VID to alleviate congestion and minimize operational costs. NTO is modeled using a node-breaker formulation to provide enhanced switching granularity, while DLR incorporates weather-dependent parameters, including wind speed and ambient temperature, to dynamically adjust transmission limits. The resulting formulation is a mixed-integer nonlinear program due to power flow constraints with bilinear VID terms, and discrete topology decisions. To improve tractability, we propose using a McCormick relaxation approach to linearize bilinear terms. Furthermore, we propose an iterative refinement of the McCormick relaxation scheme to enhance solution accuracy. The proposed framework is validated through detailed analyses on the IEEE 118-bus system, along with additional case studies on other benchmark systems to assess scalability. Results demonstrate that the proposed approach improves solution accuracy compared to standard McCormick relaxation, achieves solution quality close to the nonlinear formulation, and maintains computational efficiency.

0.29

EndoWake: Modeling Wind by Linear Programming for Wind Farm Layout Optimization

cs.CE math.OC ·2026-09-30 ·Martina Fischetti, Matteo Fischetti
similarity 0.58
Abstract · 30 pages + 12 pages of supplementary material (appended after the references). Replication package: https://doi.org/10.5281/zenodo.22017424

The Wind Farm Layout Optimization problem consists of placing a given number of turbines within a given area so as to maximize energy production. One of its main challenges is the wake effect between turbines, which can strongly affect production and is a cumbersome function to evaluate and to embed in an optimization framework. In this paper we introduce a new endogenous wake model (EndoWake), based on the idea of treating the wind speed at every grid point as a decision variable, linked to its upwind neighbors through linear propagation constraints. This makes it possible to incorporate the wake equations directly into a Mixed-Integer Linear Programming (MILP) model. We then develop such a MILP model and, in particular, introduce a new class of valid "band" inequalities, showing that they substantially strengthen the root bound. Building on this, we design a branch-and-check scheme: the master problem retains only the site variables together with one hypograph variable per cell and scenario, integer solutions are evaluated by an exact linear-time oracle, and the optimality cuts are problem-specific "upwind cuts". Computational results are reported on a ladder of square grids under a four-sector axial wind rose, demonstrating the effectiveness of the proposed improvements.

0.58

Converter-Aware Coordination of Computing Flexibility in Behind-the-Meter Data Centers

eess.SY ·2026-10-16 ·Ruolan Cui, Ruizhang Yang, Chenxi Hu, Franxis Yunhe Hou
similarity 0.55
Abstract

Data centers are emerging as large electricity consumers whose demand can be reshaped through workload scheduling. However, computing flexibility in behind-the-meter facilities does not automatically translate into electrically realizable power flexibility. Ignoring converter and network operating limits may cause converter overloads, protection trips, and interruptions to power supply and computing services. This paper proposes a converter-aware intraday scheduling methodology. First, a task-level mixed-integer linear formulation preserves synchronous training configurations and completion requirements, while Minkowski-sum aggregation and Shapley--Folkman convexification yield a linear inference-pool representation without unit-level binary variables. The latter admits a conditional relative relaxation-gap bound that decreases inversely with pool size. Second, a four-node electrical model links computing demand, on-site injections, and grid exchange to converter and network limits through lifted voltage variables and second-order cone relaxation. Finally, a mixed-integer model coordinates workloads, photovoltaic generation, energy storage, and grid purchases. Case studies show that electrical limits reshape scheduling and renewable utilization, while on-site resources reduce grid dependence. Under the studied conditions, fixed training cannot support full inference service within voltage limits, whereas coordinated scheduling achieves negligible inference shortage and passes verification against the original alternating-current model. These findings demonstrate the role of computing--electrical coordination in realizing the operational value of workload flexibility.

0.14

Water as a Battery: Using Hydropower Flexibility to Support the Grid

eess.SY ·2026-10-25 ·Chinmay Morankar, Abdullah Al Mehadi
published similarity 0.55
Abstract

This study presents a two-layer optimization framework to determine the optimal sizing of PV, wind, and battery storage co-located with existing hydroelectric plants to support rapidly increasing data center loads while minimizing cost, grid reliance, and transmission upgrades. The outer layer uses Particle Swarm Optimization (PSO) to select capacity combinations, while the inner layer performs rolling-horizon dispatch simulations to model hourly energy balance among PV, wind, hydro, and BESS, considering operational constraints. Two case studies were analyzed. At The Dalles Dam (Oregon), favorable wind resources and land availability enabled deployment of 111.2 MW PV and 117.9 MW wind, with no BESS required. Hydro flexibility allowed the system to meet the load with minimal grid support. In contrast, Conowingo Dam (Maryland) faced land constraints and limited renewables to 130 MW PV, leading to higher grid dependence. Co-locating hydro with renewables significantly enhances reliability and cost effectiveness by leveraging hydro's dispatchability to balance daily and seasonal variable generation from PV + Wind, reducing the need for storage or costly grid imports. This analysis provides a framework to meet the 99.9% availability targets of this new load type on the grid with sustainable energy resources.

0.32

Integrated Thermal and Power Management for Wave-Powered Subsea Data Centers via Nonlinear Model Predictive Control

eess.SY ·2026-09-28 ·Wanqun Yang, Jun Chen
similarity 0.54
Abstract · 14 figures and 11 tables

This paper develops an integrated modeling and nonlinear model predictive control (NMPC) framework for coordinating thermal management, flexible workload scheduling, wave-power utilization, and battery operation in a wave-powered subsea data center. Realistic data center workloads are constructed from job-level CPU, memory, and GPU measurements from the MIT Supercloud dataset and divided into interactive and delay-tolerant flexible jobs. Thermal behavior is represented by a three-node lumped model of the IT equipment, recirculating nitrogen, and pressure hull with surrounding seawater as the thermal boundary. The NMPC jointly optimizes the flexible workload power budget and cooling command subject to thermal, battery, and workload constraints. Closed-loop simulations under different workload, thermal, battery, and renewable-generation conditions demonstrate that the proposed framework maintains thermal safety while adapting cooling operation and flexible workload execution to wave-power availability and battery state-of-charge. The parametric studies show that battery capacity and wave-generation capacity strongly affect battery availability and flexible-workload queue accumulation, while excessive renewable generation capacity may lead to increased energy curtailment. Monte Carlo and distance-correlation analyses further show that flexible-job delay is relatively insensitive to the investigated system parameters, whereas terminal battery state-of-charge is primarily influenced by battery energy capacity and wave generation capacity.

0.17

Continuous-Time Aggregation of Massive Flexible HVAC Loads Considering Uncertainty for Reserve Provision in Power System Dispatch

eess.SY ·2026-09-02 ·Jingguan Liu, Xiaomeng Ai, Jiakun Fang, Shichang Cui, Shengshi Wang +2 more
top venuehot directionhighly cited similarity 0.54
Abstract · Published in: IEEE Transactions on Smart Grid (vol. 15, no. 5, pp. 4835-4849, 2024)

Heating, ventilation, and air conditioning (HVAC) loads, with their rapid response capabilities, can provide considerable intra-hour flexibility on the demand side for reserve provision in order to follow the fast variations of renewables. However, scheduling massive HVACs is challenging due to computation complexity and the uncertainty of outdoor temperature. In this paper, we first introduce a novel continuous-time (CT) aggregation model to reveal the potential intra-hour flexibility of HVACs. For accurate aggregation, a new affine transformation is designed to handle the heterogeneity in high-dimensional feasible region. Further, for reliable aggregation in practical environment, the outdoor temperature uncertainty is constructed by distributionally robust chance constrains and integrated into the aggregation model. Secondly, for the tractable calculation of the proposed CT aggregation model, a cascade of tailored reformulation techniques is proposed, including the Bernstein polynomial spline, polytope projection, and linearization transformation. Thirdly, a customized hierarchical dispatch framework is proposed via incorporating the proposed CT aggregation model into reserve provision in power system dispatch, so as to efficiently schedule massive HVACs to cope with the renewable uncertainty. Case studies verify the effectiveness and scalability of the proposed CT aggregation model in aggregation accuracy, intra-hour flexibility utilization, and uncertainty handling.

0.67

Comparative Evaluation of MILP, MPC, and Reinforcement Learning for Commercial Battery Dispatch Under Time-of-Use Tariffs

eess.SY ·2026-09-13 ·Hafiz Majid Hussain, Wajiha Samar, Lurian Klein, Pedro Nardelli
benchmark similarity 0.53
Abstract

Battery energy storage systems (BESS) paired with rooftop photovoltaics (PVs) can deliver measurable cost savings under time-of-use (TOU) electricity tariffs; however, the relative performance of model-based and model-free dispatch strategies remains insufficiently benchmarked on full-year, real-world commercial datasets. This paper presents a full-year (2023) comparative evaluation of three BESS dispatch approaches using data from a commercial PV installation operating under a TOU tariff. The examined strategies include: (i) a mixed-integer linear programming (MILP) formulation with perfect foresight, providing an oracle performance benchmark under the assumed model; (ii) a model predictive control (MPC) scheme based on a day-ahead persistence forecast, representing a low-complexity deployable approach; and (iii) a soft actor-critic (SAC) deep reinforcement learning agent trained under causal information constraints. The MILP benchmark achieves an annual cost reduction of 24.6\% relative to a no-storage baseline. The persistence-based MPC approach recovers 99.2\% of this benchmark using only prior-day data. In contrast, the evaluated SAC agent yields an annual cost higher than the no-storage baseline. This outcome is analyzed in the context of known challenges in reinforcement learning for energy systems, including limited observability and reward design. Overall, the results indicate that, for the studied dataset and tariff structure, persistence-based MPC captures nearly all achievable economic benefits under practical deployment constraints, whereas the considered RL configuration does not yield competitive performance under the same information limitations.

0.21

Strengthening AC optimal power flow relaxation through offline bound tightening and linear approximations

eess.SY math.OC ·2026-10-23 ·Xiangxin An, Constance Crozier, Santanu S. Dey
similarity 0.53
Abstract · 15 pages, 4 figures

The alternating-current optimal power flow (ACOPF) problem is fundamental to power system operation and planning, but its nonconvexity makes globally optimal solutions of large-scale instances computationally challenging. Convex relaxations provide tractable lower bounds for assessing solution quality and supporting global optimization, although their effectiveness depends strongly on relaxation strength. This paper proposes an offline convexification and bound tightening framework for constructing strong linear programming (LP) relaxations for families of related ACOPF instances. Rather than repeating the tightening procedure for each instance, we compute variable bounds and second-order cone outer-approximation (SOC-OA) cuts offline using a demand-slack model and reuse them for subsequent instances with the same topology and admissible demand variations. Computational results on PGLib instances show that the fully offline approach achieves an average gap of $4.32\%$, compared with $3.80\%$ for the fully online approach, while achieving an average speedup of approximately $272\times$. The results demonstrate that offline convexification and bound tightening can recover most of the relaxation improvement of online tightening while significantly reducing the computational burden for repeated ACOPF evaluations.

0.32