Voltage Stability Assessment with Path-Coupled Load Growth and Corrective Generator Response

Lanqing Shan

eess.SY ·submitted 2026-08-15 08:47 UTC · v1

Abstract

Voltage stability margin assessment is essential for the secure operation of renewable-dominated power systems. Conventional continuation-based methods evaluate the margin along predefined load-growth paths with fixed generator partic- ipation, while practical operation allows generators to be redis- patched to alleviate voltage stress and reshape the power-flow trajectory as the system approaches voltage collapse. This paper proposes a path-coupled margin assessment approach that incor- porates corrective generator response into static voltage stability margin assessment. In the proposed approach, the load-growth direction and generator response direction are simultaneously determined at each continuation step, enabling the assessment trajectory to account for generator response while tracing the system toward voltage collapse. The voltage stability margin is then evaluated by the cumulative active load increase along this coupled trajectory. Based on the obtained trajectory and collapse point, a feasible redispatch direction is further derived to improve the margin of the current operating state. The economic cost of voltage stability enhancement is quantified through a marginal stability cost, providing an economic indicator for additional sta- bility support. Case studies on various test systems demonstrate that the proposed framework can effectively capture the impact of corrective generator redispatch on voltage stability assessment, provide effective guidance for margin enhancement, and quantify the cost associated with voltage stability improvement.

Closest papers

Nearest neighbours by meaning across the whole index.

Equivalent Modeling of Load-Side Systems With Distributed Renewable Generation Considering Fault Responses and Nodal Voltage Coherence

eess.SY ·2026-09-21 ·Yuqi Cao, Chen Shen, Shaowei Huang, Ying Chen, Hongyi Zhu
similarity 0.63
Abstract · Submitted to IEEE Transactions on Power Systems

Operating conditions and fault severity change both the initial states and control modes of active distribution networks. Direct capacity aggregation can therefore lose the power responses required for transmission-system dynamic analysis. This paper develops a procedure for generating low-order physical electromagnetic transient equivalents from a small set of representative operating conditions. Device power, ride-through states, load mechanical states, and local sequence voltages are combined with electrical distance to form response families. Response reconstruction and terminal simulation errors determine the retained architecture, after which bounded sensitivity calculations determine effective dynamic coefficients. The architecture and coefficients are then fixed. For a new operating condition, capacity and power balances, voltage-dependent load relations, and an initialization correction generate the model parameters from static inputs and power-flow results. A representative severe fault establishes a template for each fault type, which is reused across fault depths. Aggregation and switching-time bounds explain the roles of voltage coherence and state separation. Comparisons with direct aggregation show improved terminal responses across operating conditions and several fault types, with the largest gains under severe unbalanced faults. The method provides a reusable physical equivalent for operating-condition studies and fault-depth screening.

0.17

KPG193-ext: A Synthetic Korean Power Grid Test System for Stability Analysis

eess.SY ·2026-11-09 ·Sungyoon Song, Geonho Song, Min-han Yoon, Yong-Hyun Song, Seung Wan Kim +1 more
similarity 0.57
Abstract

Growing shares of inverter-based generation and constrained transmission expansion increase the need to assess stability across operating conditions. Production-cost models provide chronological commitment and dispatch, but stability analysis requires corresponding electrical detail and device dynamics. This paper introduces KPG193-ext, an extension of the synthetic Korean power-grid test system KPG193 that links chronological operating points with detailed electrical and dynamic models. The extension adds synchronous-machine, controller and renewable-converter models, together with explicit voltage levels, generation terminals, inter-voltage and step-up transformers, and reactive compensation. The resulting 731-bus network retains the original 193 regional locations. Daily unit commitment followed by hourly AC optimal power flow establishes 8,760 operating points for 2025, each distributed as paired steady-state and dynamic-model files. Selected-hour studies examine generation-loss frequency response, steady-state flow-voltage characteristics, and rotor-angle response with special protection system actions. The results reveal differences in delivered frequency support, internal voltage stress along regional transfer paths, and the angle-frequency tradeoff of corrective generator tripping. The database provides a common basis for examining the stability implications of commitment, dispatch and corrective action across daily and seasonal operating conditions.

0.32

Unifying Heterogeneous Dissipativity for Distributed Power-System Stability Analysis

eess.SY ·2026-11-11 ·Xi Ru, Xiaoyu Peng, Feng Liu
similarity 0.56
Abstract · 11 pages, 9 figures

Compositional dissipativity is attractive for large-scale interconnected systems, but its application to modern heterogeneous power systems is limited by conservative descriptions of nodal dissipativity and inefficient distributed implementation. This paper introduces a common first-order dynamic lifting of the physical voltage-current port, providing an enriched dissipativity representation that captures complementary frequency-dependent energy behavior while preserving network composability. The resulting representation accommodates heterogeneous power system buses within a unified dissipativity description and enables less conservative compositional stability analysis. A centralized stability-certification problem is then formulated and solved through a dual-guided column-generation scheme. Its matrix dual reveals the network-critical dissipation direction, which guides parallel local certificate generation toward the current system bottleneck. This leads to a distributed Network-Critical Margin Exchange (NCME) method with early stability certification. Case studies demonstrate substantially reduced conservatism of the dynamic-port formulation and improved computational and communication scalability of NCME for heterogeneous power systems.

0.26

Scalable Voltage-Stability Dataset Generation Via Boundary-Proximity Indicators Clustering

eess.SY ·2026-08-28 ·Rock Agon, Robin Preece, Jovica V. Milanović
similarity 0.54
Abstract · Submitted to MedPower Conference 2026

This paper proposes a scalable framework for voltage-stability dataset generation. Voltage-stability-constrained planning increasingly relies on machine-learning surrogates but training them requires large datasets labelled by continuation power flow (CPF) results, which is computationally costly. To address this, this paper proposes a framework that uses hierarchical clustering on boundary-proximity indicators to reduce the number of required CPF evaluations. The proposed approach combines (i) uniform sampling of feasible operating space using Hit-and-Run Markov Chain Monte Carlo, (ii) structured stress directions via maximin Latin hypercube sampling (LHS), (iii) sensitivity-guided perturbations to target weak buses, and (iv) clustering-based representative CPF labelling that reconstructs the voltage stability margins of unlabelled operating points from representative cluster medoids. Results on the IEEE 39-bus system show that the proposed framework significantly reduces CPF evaluations by 95.45% while preserving high accuracy and boundary fidelity for both regression and classification tasks. The reduced surrogates remain structurally consistent with their full-CPF dataset counterparts, demonstrating the suitability and scalability of the proposed approach for operation and planning optimization.

0.25

Resource-Aware Rolling-Horizon Controller for Renewable-Based Virtual Power Plants Providing Automatic Frequency Restoration Reserves

eess.SY ·2026-09-25 ·Marco Vinicio Avendaño-Caiza, Juan Diego Rios-Peñaloza, Javier Roldán-Pérez, José Luis Rodríguez-Amenedo, Milan Prodanovic
similarity 0.53
Abstract · Submitted to a scientific journal for possible publication. 10 pages, 11 figures

Virtual power plants (VPPs) are an effective solution for increasing the penetration of renewable energy sources (RES) in power systems. Moreover, VPPs can provide ancillary services if generators and loads are closely connected and properly coordinated. This aspect has been addressed in several studies, yet they mostly focus on the dispatch optimisation level, leaving real-time operation aspects unresolved. To close this gap, a central controller for VPPs based on a rolling-horizon optimisation is proposed in this work. Its main objective is to maximise revenues while delivering frequency restoration services. A day-ahead optimisation firstly defines the power setpoint and the upward and downward reserves of the VPP. Then, the rolling-horizon optimiser, executed every minute, distributes the power and reserve references between the VPP units to achieve their close tracking while taking into account resource availability (wind speed, irradiance, etc.), operational constraints and battery degradation. The effectiveness of the controller is tested using a two-area interconnected power system under different RES generation and demand profiles. The simulations are performed in MATLAB/Simulink and include detailed dynamic models of the VPP elements, demonstrating the applicability of the algorithm to real systems. The day-ahead and the rolling-horizon optimisation problems are modelled using YALMIP and solved using Gurobi. The obtained results demonstrate the VPP supporting grid frequency restoration by optimally allocating its resources, even under the presence of forecast uncertainty.

0.18

A Primal-Dual Formulation for Pricing Static Voltage Stability Services within a Unit Commitment Model

eess.SY ·2026-09-10 ·Peng Wang, Luis Badesa
similarity 0.53
Abstract

In modern power systems with high penetration of Inverter-Based Resources (IBR), most converters operate in Grid-Following (GFL) mode. Some buses exhibit inherently low Short-Circuit Ratios (SCRs), a property majorly shaped by network topology. The integration of GFL-IBR onto such weak buses thus demands attention to static voltage stability. To address this issue, market mechanisms have been proposed to incentivize generators to provide voltage stability services, such as commitment of synchronous generators for reducing the equivalent impedance at low SCR buses and adaptive reactive power support from GFL-IBR. To compute shadow prices for these services, previously proposed methods such as the `restricted' and `dispatchable' approaches may fail to guarantee operating cost recovery for voltage-stability service providers. As the resulting prices are determined purely from a social surplus maximization objective, the profitability of units is entirely overlooked. This suggests that new pricing methodologies are needed to satisfy cost-recovery requirements. Therefore, this paper proposes a pricing method based on a primal-dual formulation. Case studies demonstrate that the proposed method can consistently produce revenue-adequate shadow prices, enabling all participating units to recover their costs without supplementary uplift payments.

0.17

When Gigawatts of Computational Load Disappear: Cycle-Space Certificates for Grid Synchronization and Transient Stability

eess.SY math.DSphysics.soc-ph ·2026-09-23 ·Michael Chertkov
similarity 0.52
Abstract · 13 pages, 2 figures

Rapid growth of data centers and artificial-intelligence services is producing computational loads at scales once associated mainly with largest power plants. Recent grid events show that a routine transmission disturbance can cause several gigawatts of data-center demand to disconnect or transfer to backup nearly at once. This article revisits the classical synchronization and transient-stability theory needed to reason about such events. We organize four lines of work---graph-based synchronization conditions, winding-number descriptions of nonlinear power flow, separable convex network optimization, and direct energy methods---into a single cycle-space certificate framework for the lossless fixed-voltage model. The static layer gives an exact strict-cohesion test within a prescribed winding cell and reveals the widely used Dörfler--Chertkov--Bullo test as a quadratic surrogate of the same convex problem. The dynamic layer converts the critical-energy calculation into a finite family of convex boundary problems. Standard MATPOWER benchmarks illustrate both what the stronger static test gains and where it gains nothing: the 118-bus case admits $16.2\%$ more loading than the sufficient screen, while the 39-bus case is bridge-limited and the thresholds coincide. A stylized $2.7$-GW 39-bus event further shows that transient margin can change by about a factor of two depending on where balancing power is supplied, even when every final balanced operating point remains statically feasible. The result is a tutorial synthesis and an extensible deterministic certificate for emerging gigawatt-scale computational-load contingencies.

0.53

Low-Voltage Ride-Through in AI Data Centers via Coordinated Battery and Computing Load Control

eess.SY ·2026-11-14 ·Xiaoyang Wang, Xin Chen, Fang Chen Lin, Prasad Enjeti, Ali Yazdanpanah +2 more
hot direction similarity 0.51
Abstract · 5 pages, 7 figures

The ability of large AI data centers to ride through grid voltage sags is critical to power system stability and reliability. This paper frames data center low-voltage ride-through (LVRT) as a DC-link power balance problem. Once the rectifier reaches its current limit, the power drawn from the grid decreases in proportion to the grid voltage. The DC-link capacitor can supply the resulting power deficit only briefly before the DC-link voltage falls low enough to trigger undervoltage protection tripping. To address this issue, this paper proposes effective control strategies for coordinating uninterruptible power supply (UPS) battery and computing load curtailment to offset the power deficit and enable LVRT at minimum control cost. Three control scenarios are studied: UPS battery support alone, computing load curtailment alone, and the coordinated use of both resources. Electromagnetic transient (EMT) simulations using the TAMU-ERCOT AI data center model demonstrate that battery support and the coordinated strategy achieve LVRT for all tested sags, including a near-zero-voltage fault, while load curtailment alone rides through moderate voltage sags.

0.22