KPG193-ext: A Synthetic Korean Power Grid Test System for Stability Analysis

Sungyoon Song, Geonho Song, Min-han Yoon, Yong-Hyun Song, Seung Wan Kim, Jip Kim

eess.SY ·submitted 2026-11-09 13:59 UTC · v1

Abstract

Growing shares of inverter-based generation and constrained transmission expansion increase the need to assess stability across operating conditions. Production-cost models provide chronological commitment and dispatch, but stability analysis requires corresponding electrical detail and device dynamics. This paper introduces KPG193-ext, an extension of the synthetic Korean power-grid test system KPG193 that links chronological operating points with detailed electrical and dynamic models. The extension adds synchronous-machine, controller and renewable-converter models, together with explicit voltage levels, generation terminals, inter-voltage and step-up transformers, and reactive compensation. The resulting 731-bus network retains the original 193 regional locations. Daily unit commitment followed by hourly AC optimal power flow establishes 8,760 operating points for 2025, each distributed as paired steady-state and dynamic-model files. Selected-hour studies examine generation-loss frequency response, steady-state flow-voltage characteristics, and rotor-angle response with special protection system actions. The results reveal differences in delivered frequency support, internal voltage stress along regional transfer paths, and the angle-frequency tradeoff of corrective generator tripping. The database provides a common basis for examining the stability implications of commitment, dispatch and corrective action across daily and seasonal operating conditions.

Closest papers

Nearest neighbours by meaning across the whole index.

Impact of Grid-Forming Inverter Placement and Penetration on Local and Aggregate Frequency

eess.SY ·2026-11-13 ·Fatma Alfailkawi, Marena Trujillo, Bri-Mathias Hodge
similarity 0.60
Abstract

Modern power systems are undergoing a huge shift in generation mix, including inverter-based resources that are fundamentally changing the stability dynamics of the grid. Thus, synchronous Generators (SG) are gradually being displaced by Grid-forming inverters (GFM) that are proposed as a solution to continue supporting grid stability. However, the effect of GFM placement in the network on frequency performance and how well aggregate-frequency assessment captures placement sensitivity observed in local frequency metrics remains unclear. This paper evaluates all SG and droop-controlled GFM assignments in the IEEE 39-bus system. A reduced-order model is used for the exhaustive search with load disturbances applied separately at every eligible load bus while considering nadir and Rate of Change of Frequency (RoCoF) derived from both device rating weighted aggregate frequency and local bus frequencies. Results reveal that at fixed GFM penetration, placement produced up to 104 mHz variation in worst-case local nadir and 0.21 Hz/s in maximum local RoCoF. Aggregate-frequency assessment reduced the apparent across placements by 89\% for nadir and 88\% for RoCoF at 50\% GFM penetration. These results indicate that aggregate-frequency assessment alone may obscure favorable or adverse placement effects on local frequency performance.

0.36

GFM Control Automatic Compliance Toolbox

eess.SY ·2026-11-08 ·Tejas Kunbi, Rahul Rane, Dan Wu, Aleksandra Lekić
similarity 0.59
Abstract

The increasing penetration of converter-interfaced generation reduces system inertia, short-circuit strength, and voltage support. European grid codes, including the ENTSO-E Network Code on Requirements for Generators and the ACER Demand Connection Code, now define disturbance-based validation procedures for grid-forming (GFM) generation and converter-based demand. Commercial RMS tools, however, lack an integrated workflow aligned with these recent requirements. This paper presents an automated Python-PowerFactory compliance toolbox and an RMS test bench for a co-located system comprising a 1 MW GFM photovoltaic (PV) plant, a 0.3 MW GFM battery energy storage system (BESS), and a 1 MW converter-interfaced dynamic load at a 20 kV point of common coupling fed from a 110 kV grid. Extended virtual synchronous machine models and a DCC-oriented load model are tested in batch, with results automatically extracted and plotted for assessment. Results show compliant RMS performance for the slower, electromechanical tests, while the paper identifies which tests require complementary electromagnetic transient (EMT) verification.

0.34

Enhancing Transient Stability of VSG-Controlled Converters Under Grid Frequency Disturbances

eess.SY ·2026-11-13 ·B. Li, Y. Zhang, X. Wang, S. Yang, Z. Hao +1 more
similarity 0.58
Abstract

Strong damping feedback can substantially improve the transient synchronization stability of renewable energy converters employing virtual synchronous generator (VSG) control. However, conventional damping feedback uses the nominal frequency as its reference. When the frequency of a weak grid deviates from nominal, strong damping tends to keep the VSG frequency near nominal. This can sustain a frequency difference between the VSG and the grid and compromise transient synchronization. To address this problem, this paper proposes a complex-frequency-based method to estimate the grid reference frequency from local terminal measurements. The estimated frequency replaces the nominal reference in the VSG synchronization loop, so that damping acts on the frequency difference between the VSG and the real grid. Controller hardware-in-the-loop tests validate the effectiveness of the proposed method under grid frequency disturbances and its robustness to grid parameter uncertainty and adverse grid conditions.

0.33

A Primal-Dual Formulation for Pricing Static Voltage Stability Services within a Unit Commitment Model

eess.SY ·2026-09-10 ·Peng Wang, Luis Badesa
similarity 0.57
Abstract

In modern power systems with high penetration of Inverter-Based Resources (IBR), most converters operate in Grid-Following (GFL) mode. Some buses exhibit inherently low Short-Circuit Ratios (SCRs), a property majorly shaped by network topology. The integration of GFL-IBR onto such weak buses thus demands attention to static voltage stability. To address this issue, market mechanisms have been proposed to incentivize generators to provide voltage stability services, such as commitment of synchronous generators for reducing the equivalent impedance at low SCR buses and adaptive reactive power support from GFL-IBR. To compute shadow prices for these services, previously proposed methods such as the `restricted' and `dispatchable' approaches may fail to guarantee operating cost recovery for voltage-stability service providers. As the resulting prices are determined purely from a social surplus maximization objective, the profitability of units is entirely overlooked. This suggests that new pricing methodologies are needed to satisfy cost-recovery requirements. Therefore, this paper proposes a pricing method based on a primal-dual formulation. Case studies demonstrate that the proposed method can consistently produce revenue-adequate shadow prices, enabling all participating units to recover their costs without supplementary uplift payments.

0.17

Voltage Stability Assessment with Path-Coupled Load Growth and Corrective Generator Response

eess.SY ·2026-08-15 ·Lanqing Shan
similarity 0.57
Abstract

Voltage stability margin assessment is essential for the secure operation of renewable-dominated power systems. Conventional continuation-based methods evaluate the margin along predefined load-growth paths with fixed generator partic- ipation, while practical operation allows generators to be redis- patched to alleviate voltage stress and reshape the power-flow trajectory as the system approaches voltage collapse. This paper proposes a path-coupled margin assessment approach that incor- porates corrective generator response into static voltage stability margin assessment. In the proposed approach, the load-growth direction and generator response direction are simultaneously determined at each continuation step, enabling the assessment trajectory to account for generator response while tracing the system toward voltage collapse. The voltage stability margin is then evaluated by the cumulative active load increase along this coupled trajectory. Based on the obtained trajectory and collapse point, a feasible redispatch direction is further derived to improve the margin of the current operating state. The economic cost of voltage stability enhancement is quantified through a marginal stability cost, providing an economic indicator for additional sta- bility support. Case studies on various test systems demonstrate that the proposed framework can effectively capture the impact of corrective generator redispatch on voltage stability assessment, provide effective guidance for margin enhancement, and quantify the cost associated with voltage stability improvement.

0.34

Local Energy Function-Based Power System Transient Stability Analysis with Grid Forming and Grid Following Inverters

eess.SY ·2026-09-06 ·Yingyi Tang, Junbo Zhao, Baosen Zhang
similarity 0.57
Abstract

The widespread deployment of inverter-based resources (IBRs) is reshaping power system dynamics by their control strategies. Grid-following (GFL) and grid-forming (GFM) inverters are expected to co-exist from now on. However, ensuring the transient stability of such systems remains a critical and underexplored challenge. In this paper, a comprehensive transient stability analysis of the mixed-GFM-GFL inverter system is conducted using a newly derived local energy function. The transient stability analysis model of the system is first derived to reveal the dynamic interactions between GFL and GFM inverters during transient responses. A local energy function is then proposed for analytical transient stability assessment. Instead of ignoring or making harsh assumptions on inverters' coupled damping effect, the proposed local energy function carefully addresses its impact on system transient stability by locally bounding the region where the system's energy dissipation property holds. Such a property fully considers the combined damping effect of GFL and GFM inverters. The derived critical energy and stability index provide a fast and quantitative transient stability assessment. Furthermore, the adverse impact of insufficient damping of GFM inverters on system transient stability is thoroughly investigated. The effectiveness of the proposed method is validated on the modified IEEE 14-bus system with mixed GFL and GFM inverters, and the numerical simulation results further demonstrate the small conservativeness of the proposed method.

0.24

Report on Stability Analysis of Islanded Power Systems with Grid-Forming Converters

eess.SY ·2026-10-30 ·Anup Joshi, Luis A. Garcia-Reyes, Qingyuan Gong, Xavier Guillaud, Javier Renedo +1 more
published similarity 0.55
Abstract · Danmarks Tekniske Universitetet, Katholieke Universiteit Leuven, Department of Electrical Engineering, Electrical Energy Computer Architectu…

Islanded power systems are inherently challenging to operate due to limited interconnection, low inertia, and weak short-circuit strength. As renewable and inverter-based resources replace synchronous machines, these challenges worsen, causing faster frequency deviations, greater voltage volatility, and higher risk of instability. This report summarizes the differences between islanded and interconnected systems and reviews key stability issues in islanded grids: frequency stability, converter-driven interactions, voltage stability, large-disturbance behavior, and small-signal dynamics. Grid-forming (GFM) voltage source converters are a promising solution because they can establish voltage and frequency, emulate synchronous machine behavior, and provide grid strength, virtual inertia, fast frequency response, voltage regulation, and black-start capability. The report examines relevant GFM control strategies and evaluates their capabilities in weak, low-inertia islanded grids. Challenges remain, particularly interoperability, control coordination among multiple inverter-based resources, lack of standardized grid code requirements, and coordination of protection devices. Successful deployment requires advances in interoperability, harmonized grid codes, and grid planning that considers the unique features of islanded systems, along with clear GFM functionality requirements. Finally, a case study illustrates the stability-enhancing capability of GFM converters in weak grids through small-signal stability analysis. Overall, GFM technology is a key enabler of reliable, renewable-dominant island power systems, but broader adoption depends on continued technical and regulatory development.

0.36

An Open Synthetic Test System for the Jordanian Transmission Grid

eess.SY ·2026-08-31 ·Muhy Eddin Zater, Bri-Mathias Hodge
benchmark similarity 0.55
Abstract

Open synthetic test systems are essential for reproducible power system research, yet the available cases represent almost exclusively North American and European grids. No open transmission test system exists for any Middle Eastern country, whose grids raise different questions such as single corridor fuel-supply resilience and high-renewable operation within small synchronous systems, and established benchmarks cannot demonstrate. This paper presents a synthetic test system for the Jordanian transmission grid, assembled entirely from public sources, where the real topology is reconstructed from a published diagram and restored to its 2018 energized state, with plant-level generation and renewable fleets, per-site hourly profiles, and loads calibrated to the values published by Jordan's grid operators. The case is validated through structural statistics against real-grid criteria, power flow and $N\!-\!1$ screening, an energy-weighted loss decomposition, in addition to a full-year production-cost run compared against the published per-plant energy, and cross-solver verification. The model reproduces the annual energy mix at technology level (largest producers within 4\%, system total within 0.1\%), and the released dataset includes the bus-identity key, all scripts, and a post-2019 scenario variant. This test case is designed to benchmark system-level resource adequacy, time-series dispatch and unit commitment, renewable integration, fuel-supply resilience scenarios, interconnection studies and steady-state studies.

0.25