CS Paper Radar

An integrated diffusion-weighted imaging processing and interpretation platform for MR-guided radiotherapy

Yunxiang Li, Yan Dai, Yen-Peng Liao, Jie Deng, Jill B De Vis, You Zhang

cs.AI physics.med-ph ·submitted 2026-08-20 19:33 UTC · v1

Abstract

Background: Magnetic resonance imaging-guided linear accelerators (MR-Linacs) allow diffusion-weighted imaging (DWI) to be acquired at every treatment fraction, but converting these low-signal-to-noise-ratio acquisitions into clinical decisions requires both reliable quantitative processing and an interpretation that reconciles a scattered and often contradictory literature. Purpose: To describe and evaluate an integrated, web-based platform that carries raw MR-Linac DWI to a structured, literature-grounded clinical interpretation, and to assess its retrieval-augmented generation (RAG) interpretation module by independent expert rating. Methods: The platform couples a deep-learning processing pipeline, comprising distortion correction, denoising, and intravoxel incoherent motion (IVIM)/apparent diffusion coefficient (ADC) fitting, with longitudinal region-of-interest analysis and a RAG interpretation agent. The agent reasons over a two-layer knowledge base of curated publications (a structured catalog index plus line-indexed full text), delegates arithmetic to deterministic tools, and is designed to trace each statement to a source document, section, and line range. One medical physicist and one physician independently rated the agent's reports for nine longitudinal glioblastoma cases on a 1-5 scale across three metrics: clinical-reasoning soundness, literature-citation quality, and overall clinical utility. Results: Across 54 ratings, the pooled mean was 4.65 +/- 0.80, with 93% of ratings >= 4; metric means were 4.6 (reasoning), 4.5 (citation), and 4.8 (utility), and raters agreed within one point on 85% of paired ratings. Conclusions: A single platform can integrate MR-Linac DWI post-processing with traceable, expert-evaluated clinical interpretation, while highlighting the safeguards needed to verify LLM-generated reasoning in radiation oncology.

Comment
29 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

cs.CV ·2026-10-19 ·J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau +5 more
similarity 0.64
Abstract · 27 pages, 7 figures plus graphical abstract

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.

0.12

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey similarity 0.60
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.21

MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and Protontherapy

cs.AI physics.med-ph ·2026-11-20 ·Juan Manuel Molina-Maza Chih-Wei Chang, David Viar-Hernandez, Zach Eidex, Mojtaba Safari, Shaoyan Pan +5 more
similarity 0.60
Abstract

Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast without ionizing radiation but lacks the electron-density information needed for radiotherapy dose calculation. Dual-energy computed tomography (DECT) improves tissue characterization and stopping-power ratio (SPR) estimation for proton therapy, but requires additional radiation exposure. We developed a denoising diffusion probabilistic model (DDPM) to synthesize high- and low-energy CT (sHECT and sLECT) simultaneously from a single MRI scan. Retrospective paired MRI-DECT data from patients receiving head-and-neck proton therapy were used to train and evaluate a multi-decoder DDPM with SwinViT or ResUNet denoisers. Performance was compared with Pix2PixGAN and CycleGAN using image-quality metrics, Hounsfield unit (HU) errors, anatomical profiles, and SPR maps and uncertainties. The DDPM outperformed both generative adversarial network baselines in visual fidelity and quantitative image quality. For sHECT and sLECT, respectively, mean absolute errors were 36.29 +/- 5.25 and 43.72 +/- 6.77 HU; peak signal-to-noise ratios were 27.44 +/- 1.06 and 26.26 +/- 0.98 dB; structural similarity indices were 0.89 +/- 0.02 and 0.87 +/- 0.03; and normalized cross-correlations were 0.95 +/- 0.01 and 0.94 +/- 0.01. The synthesized images preserved anatomical boundaries, while uncertainties in derived SPR maps remained within the expected acceptable range. MRI-based DECT synthesis using DDPM may provide tissue-specific information for proton therapy planning while reducing the need for radiation-based DECT acquisition.

0.22

Resampling-based batch reweighting for ComBat harmonization of MRI radiomic features in a multi-scanner glioma cohort

eess.IV physics.med-ph ·2026-11-01 ·Rifa Sajda Tasnim, Yushuf Sharker, Md Forhad Hossain, Rakibur Rahman, Enamul Hoque Bhuiyan
published similarity 0.60
Abstract · Original article. Submitted to Journal of Magnetic Resonance Imaging (JMRI)

Radiomic features derived from magnetic resonance imaging (MRI) are sensitive to scanners; therefore, they require harmonization across scanners. In a radiomic feature dataset, some batches may be severely underrepresented compared to the others e.g., the Erasmus Glioma Database, which may provide harmonized features biased towards the larger batches in the dataset. We investigated whether reweighting underrepresented scanner batches before empirical-Bayes ComBat estimation improves feature harmonization and reduces residual scanner association while retaining grade-related information. In this retrospective, the Erasmus Glioma Database included 733 eligible patients acquired at a single center across nine vendor-by-field-strength configurations. Structural MRI acquired at 1 T, 1.5 T, and 3 T; four structural MRI sequences were analyzed. From four structural MRI sequences, 428 features were computed using an IBSI-compliant PyRadiomics implementation. The sample sizes of some scanner batches were very small compared to others, which may produce unequal precision and shrinkage of batch-effect estimates. We proposed a data augmentation approach to overcome the limitation of ComBat. We provided exploratory evidence, along with confirmatory Kruskal-Wallis tests with a Benjamini-Hochberg correction to assess the proposed method. Before harmonization, 392/428 features (91.6%) differed significantly across scanner batches (median eta-squared=0.463). Standard ComBat reduced this to 13/428 (3.0%), whereas batch-augmented ComBat reduced it to 8/428 (1.9%); the median residual effect size was <0.001 for both harmonized conditions. Batch augmentation appeared to be a useful strategy to improve the performance of ComBat for feature harmonization under severe batch-size imbalance.

0.32

Large-Scale Pretraining for Improving Deep Learning-Based Geometric Distortion Correction of Diffusion-Weighted Imaging

cs.CV cs.LG ·2026-09-06 ·Saroj Khanal, Yashawant Kumar Yadav, Kritam Bhattarai, Jeevan Neupane, Shristi Subedi +10 more
similarity 0.59
Abstract

Diffusion-weighted imaging (DWI) is widely used in clinical settings but remains vulnerable to geometric distortion. Conventional correction methods often require additional acquisitions or vendor-specific solutions, limiting their feasibility in high-throughput, resource-constrained settings. This study investigates whether large-scale pretraining strategies can improve deep learning-based distortion correction for single-phase-encoding DWI. We formulate the task as image reconstruction, and compare a non-pretrained baseline against a self-supervised and a generative pretrained model, evaluated using both quantitative image-similarity metrics and qualitative expert assessment. The best-performing model was further tested for transferability on data collected in an LMIC setting with acquisition shift. Pretrained models outperformed the non-pretrained baseline, with cWDM achieving the strongest results across both quantitative and qualitative evaluation. However, application to LMIC data revealed transferability challenges, including contrast alteration and over-reliance on T1-weighted anatomical structure. Registering images to a common standard space improved predictions, suggesting that harmonized preprocessing may enhance cross-domain deployment.

0.22

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.59
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

Uncertainty-Aware Multimodal Deep Learning for Prediction of Radiation-Induced Xerostomia in Head and Neck Cancer

eess.IV ·2026-11-19 ·Jin Yang, Tian Liu, Jose Penagaricano, Jing Wang, Erin L. Moshier +3 more
similarity 0.59
Abstract · 24 pages, 4 figures

To develop and evaluate an uncertainty-aware multimodal learning framework for predicting radiation-induced xerostomia in patients receiving head-and-neck cancer radiotherapy. We developed a Bidirectional Attention-enhanced Diffusion Transformer (BA-DiT) that combines self-supervised multimodal representation learning with supervised Bayesian fine-tuning. The model integrates pretreatment CT images and three-dimensional dose distributions, focusing on bilateral parotid glands while incorporating surrounding anatomical and dosimetric information. During pretraining, bidirectional cross-attention integrates anatomical and dosimetric features, while a latent Diffusion Transformer learns joint representations through diffusion-based learning, feature reconstruction, and contrastive alignment. Supervised fine-tuning employs a Bayesian classifier to predict individualized xerostomia risk and quantify predictive uncertainty, with a learnable label-transition model accounting for potential toxicity label uncertainty. BA-DiT was developed using four independent cohorts (Moffitt, Emory, MSHS, and TCIA) and evaluated against baseline and ablation models. Evaluation included predictive performance, calibration, uncertainty quantification, decision curve analysis, and patient-level case studies. In independent MSHS and Emory cohorts, BA-DiT achieved AUCs of 0.83 and 0.80, respectively, outperforming baseline models. Predictive uncertainty peaked near the decision boundary, with aleatoric uncertainty being the predominant component. Uncertainty-based selective prediction generally improved net benefit among retained patients, with greater gains at lower prediction coverage. BA-DiT enables individualized xerostomia risk prediction while providing complementary uncertainty estimates, potentially supporting informed clinical decision-making and personalized toxicity management.

0.14

From Natural Images to Medical Scans: Transferability of Diffusion Models for Medical Image Generation

cs.CV ·2026-11-03 ·Efthymios Georgiou, Ioannis Kakogeorgiou, Sarah Brüningk
publishedcode/data similarity 0.59
Abstract · WACV 2027

Transfer learning from natural images is standard in supervised and increasingly adopted in self-supervised medical image analysis, but its role in generative modelling, and in particular diffusion denoisers, remains underexplored. Medical diffusion models typically train the denoiser from scratch, with no systematic evaluation of natural-image transfer. We analyse this across latent and pixel paradigms, model sizes (131M-952M) and two radiology datasets (RadImageNet, BraTS), and ask which aspects of transfer support generation. We find that: i) Natural-image initialisation consistently improves generation, by 21-34% relative gFID in pixel space against 14% in latent space, where the tokeniser supplies much of the prior. gFID gains mirror downstream pathology classification and radiomic-feature FD, both proxies for clinical fidelity. ii) Benefits reflect spatial structure, not semantics: semantic probing does not predict generation quality, whereas a spatial-structure metric adapted to internal denoiser representations tracks gFID at $|r|=0.85$, positioning spatial organisation as a channel through which pretraining manifests. iii) Mixed-domain denoiser training shows that natural and medical images share similar layer-wise representations up to the late blocks, and mixing natural images into medical training improves fidelity. iv) Transfer benefit is tied to natural image initialisation, outperforming in-domain medical pretraining and several reinitialisation schemes. Overall, natural image denoisers transfer positively to medical ones in our setup. Code is available at https://github.com/CAIROLab-Bern/rad-dit

0.34