CS Paper Radar

MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and Protontherapy

Juan Manuel Molina-Maza Chih-Wei Chang, David Viar-Hernandez, Zach Eidex, Mojtaba Safari, Shaoyan Pan, Juan Maria Perez-Moreno, Norberto Malpica, Angel Torrado-Carvajal, Borja Rodriguez-Vila, Xiaofeng Yang

cs.AI physics.med-ph ·submitted 2026-11-20 20:20 UTC · v1

Abstract

Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast without ionizing radiation but lacks the electron-density information needed for radiotherapy dose calculation. Dual-energy computed tomography (DECT) improves tissue characterization and stopping-power ratio (SPR) estimation for proton therapy, but requires additional radiation exposure. We developed a denoising diffusion probabilistic model (DDPM) to synthesize high- and low-energy CT (sHECT and sLECT) simultaneously from a single MRI scan. Retrospective paired MRI-DECT data from patients receiving head-and-neck proton therapy were used to train and evaluate a multi-decoder DDPM with SwinViT or ResUNet denoisers. Performance was compared with Pix2PixGAN and CycleGAN using image-quality metrics, Hounsfield unit (HU) errors, anatomical profiles, and SPR maps and uncertainties. The DDPM outperformed both generative adversarial network baselines in visual fidelity and quantitative image quality. For sHECT and sLECT, respectively, mean absolute errors were 36.29 +/- 5.25 and 43.72 +/- 6.77 HU; peak signal-to-noise ratios were 27.44 +/- 1.06 and 26.26 +/- 0.98 dB; structural similarity indices were 0.89 +/- 0.02 and 0.87 +/- 0.03; and normalized cross-correlations were 0.95 +/- 0.01 and 0.94 +/- 0.01. The synthesized images preserved anatomical boundaries, while uncertainties in derived SPR maps remained within the expected acceptable range. MRI-based DECT synthesis using DDPM may provide tissue-specific information for proton therapy planning while reducing the need for radiation-based DECT acquisition.

Closest papers

Nearest neighbours by meaning across the whole index.

Domain-Adapted Latent Diffusion Models for CT-to-PET Image Translation

cs.CV ·2026-10-26 ·Yann Bourdé, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
similarity 0.70
Abstract

Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible than Computed Tomography (CT) due to its high cost, infrastructure requirements, and reliance on injected radioactive tracers. CT-to-PET image translation using generative models aims to address this disparity, yet state-of-the-art diffusion-based methods are limited by the scarcity of paired training data. To overcome this, we propose a domain-adapted latent diffusion framework that transfers natural-image priors using a relatively small dataset of 21,930 paired CT/PET slices, incorporating a signed power transform to resolve extreme intensity sparsity in PET data. Compared to CPDM, a state-ofthe-art baseline for CT-to-PET image translation, our approach yields superior performance in pixel-wise reconstruction and localized tumor fidelity, demonstrating effective transfer of natural-image priors to the medical domain. We further provide a systematic analysis of evaluation metric reliability for sparse PET data, showing that standard full-image metrics can be misleading indicators of translated image quality, and propose background-filtered and mask-restricted metrics as more clinically meaningful alternatives.

0.16

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.69
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.68
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.65
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.22

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

cs.CV ·2026-09-15 ·Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo +1 more
similarity 0.64
Abstract

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.

0.08

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.63
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.63
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.63
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14